7 Gmax Jockey Pump
7 Gmax Jockey Pump
7 Gmax Jockey Pump
CENTRIFUGAL PUMP
GMAX Vertical Multistage in - line
1. Application :
The GMAX series is a multipurpose pump range
suitable for a variety of different applications
demanding reliable and cost efficient supply.
Usage
GV/H R S 2 - 2 0
GMAX Multistage Series. V - Vertical, H - Horizontal
50Hz only
60Hz only
Rated flow rate in M3 / hr
Number of stages X 10
3. Technical Data :
a. Liquid Temperature
required. [%]
100
90
c. Motor 80
70
3
7
5
2
1
11
10
9
8
4
6
SPECIFICATION
Motor Q
Model 3 1 1.2 1.6 2.0 2.4 2.8 3.2 3.5
(kW) (m /h)
GVR2 - 20 0.37 18 17 16 15 13 12 10 8
GVR2 - 30 0.37 27 26 24 22 20 18 15 12
GVR2 - 40 0.55 36 35 33 30 26 24 20 16
GVR2 - 50 0.55 45 43 40 37 33 30 24 20
GVR2 - 60 0.75 H 53 52 50 45 40 36 30 24
GVR2 - 70 0.75 (m) 63 61 57 52 47 41 35 28
GVR2 - 90 1.1 80 78 73 67 61 54 45 37
GVR2 - 110 1.1 98 95 89 82 73 64 54 44
GVR2 - 130 1.5 116 114 106 98 89 78 65 52
GVR2 -150 1.5 134 130 123 112 100 90 73 60
GVR2 - 180 2.2 161 157 148 136 121 108 91 76
GVR2 - 220 2.2 197 192 180 165 148 130 110 90
GVR2 - 260 3.0 232 228 214 198 179 158 130 110
GVR - 4
50Hz 2900rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a density
of 1Kg / dm3 and a kinetic viscosity of 20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 380 - 415 V, 50 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a
density of 1kg/dm3 and a kinetic viscosity of 20 mm2/s.
SPECIFICATION
Motor Q
Model 3 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0
(kW) (m /h)
GVR4 - 20 0.37 19 18 17 15 13 10 8 6
GVR4 - 30 0.55 28 27 26 24 20 18 13 10
GVR4 - 40 0.75 38 36 34 32 27 24 19 13
GVR4 - 50 1.1 47 45 43 40 34 31 23 17
GVR4 - 60 1.1 (H) 56 54 52 48 41 37 28 20
GVR4 - 70 1.1 (m) 66 63 61 56 48 43 33 24
GVR4 - 80 1.5 74 72 70 64 55 50 38 27
GVR4 - 100 2.2 96 90 87 81 71 62 48 34
GVR4 - 120 2.2 114 108 104 95 85 75 58 41
GVR4 -140 3.0 136 126 122 112 101 89 68 48
GVR4 - 160 3.0 152 144 140 129 115 101 78 55
GVR4 - 190 4.0 183 171 168 153 137 122 93 67
GVR4 - 220 4.0 211 200 192 178 160 138 108 79
GVR - 8
50Hz 2900rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a density
of 1Kg / dm3 and a kinetic viscosity of 20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 380 - 415 V, 50 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a density
of 1kg/dm3 and a kinetic viscosity of 20 mm2 /s.
SPECIFICATION
Motor Q
Model 3 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0
(kW) (m /h)
GVR8 - 20 /1 0.75 10 9.5 9.3 9 8.5 8 7 6
GVR8 - 20 0.75 20 19.5 19 18 17 16 14 13
GVR8 - 30 1.1 30 29.5 28.5 27 25 24 21 19
GVR8 - 40 1.5 41 39.5 38 36 34 32 28 26
GVR8 - 50 2.2 H 52 50 48 45 42 40 36 32
GVR8 - 60 2.2 (m) 62 60 57 54 51 48 43 39
GVR8 - 80 3.0 83 80 77 73 69 65 58 52
GVR8 - 100 4.0 104 100 97 92 87 81 73 65
GVR8 - 120 4.0 124 120 116 111 104 97 87 78
GVR8 - 140 5.5 145 141 136 130 122 113 102 92
GVR8 - 160 5.5 166 161 156 148 139 130 118 106
GVR8 - 180 7.5 187 182 175 167 157 146 134 120
GVR8 - 200 7.5 208 202 195 186 175 163 150 135
GVR - 16
50Hz 2900rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a density
of 1Kg / dm3 and a kinetic viscosity of 20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 380 - 415 V, 50 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a density
of 1kg/dm3 and a kinetic viscosity of 20 mm2 /s.
SPECIFICATION
Motor Q
Model 3 8 10 12 14 16 18 20 22
(kW) (m /h)
GVR16 - 20 0.75 27 26 25 24 22 21 19 16
GVR16 - 30 0.75 41 40 38 37 34 32 26 25
GVR16 - 40 1.1 54 53 52 49 46 43 38 34
GVR16 - 50 1.5 68 67 65 62 58 54 48 43
GVR16 - 60 2.2 H 82 80 78 74 70 64 58 52
GVR16 - 70 2.2 (m) 96 95 91 87 82 76 68 61
GVR16 - 80 3.0 110 108 104 99 94 86 77 70
GVR16 - 100 4.0 138 136 131 125 118 109 97 87
GVR16 - 120 4.0 166 162 157 150 141 130 116 105
GVR16 - 140 5.5 194 190 184 175 166 152 136 122
GVR16 - 160 5.5 222 217 210 200 189 174 156 140
GVS - 2
60Hz 3500rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a density
of 1Kg / dm3 and a kinetic viscosity of 20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 440, 60 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a density
of 1kg/dm3 and a kinetic viscosity of 20 mm2 /s.
SPECIFICATION
Motor Q
Model 3 1 1.5 2 2.5 3 3.5 4 4.5
(kW) (m /h)
GVS2- 20 0.55 26 24 22 21 19 16 12 9
GVS2 - 30 0.75 39 36 34 31 27 24 19 15
GVS2 - 40 1.1 52 48 45 42 36 32 26 20
GVS2 - 50 1.1 H 65 61 57 52 46 41 33 25
GVS2 - 60 1.1 (m) 78 74 69 63 56 49 40 30
GVS2 - 70 1.5 92 86 81 74 66 57 47 35
GVS2 - 90 2.2 118 111 104 95 86 76 61 45
GVS2 - 110 2.2 144 137 128 117 106 91 75 55
GVS2 - 130 3.0 171 163 152 139 126 108 90 66
GVS2 - 150 3.0 198 188 176 161 146 125 104 77
GVS2 - 180 4.0 238 228 212 195 175 151 126 94
GVS - 4
60Hz 3500rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a density
of 1Kg / dm3 and a kinetic viscosity of 20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 440, 60 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a
density of 1kg/dm3 and a kinetic viscosity of
20 mm2 /s.
SPECIFICATION
Motor Q
Model 3 2.5 3 4 5 6 7 8 9
(kW) (m /h)
GVS4 - 20 0.75 26 25 23 21 19 16 14 11
GVS4 - 30 1.1 40 39 36 32 30 26 22 18
GVS4 - 40 1.5 53 52 48 44 41 35 31 24
GVS4 - 50 2.2 H 66 65 60 55 51 44 39 30
GVS4 - 60 2.2 (m) 80 78 73 67 61 54 47 36
GVS4 - 70 3 93 91 85 78 71 63 55 42
GVS4 - 80 3 107 104 97 90 82 73 63 49
GVS4 - 100 4 134 130 121 113 103 92 80 61
GVS4 - 120 4 161 156 145 136 125 111 96 74
GVS4 - 140 5.5 188 183 170 159 146 130 112 86
GVS4 - 160 5.5 215 210 196 183 168 149 128 99
GVS - 8
60Hz 3500rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a density
of 1Kg / dm3 and a kinetic viscosity of 20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 440, 60 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a density
of 1kg/dm3 and a kinetic viscosity of 20 mm2 /s.
SPECIFICATION
Motor Q
Model 3 7 8 9 10 11 12 13 14
(kW) (m /h)
GVS8- 20/1 0.75 13 12 11.5 11 10.5 10 9.5 9
GVS8 - 20 1.5 27 26 25 24 23 22 20 18
GVS8 - 30 2.2 41 40 38 37 35 33 31 28
GVS8 - 40 3 55 54 52 50 47 45 42 38
GVS8 - 50 3 H 70 68 65 63 59 56 52 48
GVS8 - 60 4 (m) 85 82 78 76 72 68 63 58
GVS8 - 80 5.5 115 111 105 101 97 91 85 78
GVS8 - 100 7.5 145 140 132 126 122 115 107 98
GVS8 - 120 7.5 175 169 160 152 148 139 129 118
GVS8 - 140 11 205 198 188 179 174 163 152 139
GVS - 16
60Hz 3500rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a
density of 1Kg / dm3 and a kinetic viscosity of
20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 440, 60 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a
density of 1kg/dm3 and a kinetic viscosity of
20 mm2 /s.
SPECIFICATION
Motor Q
Model 3 10 12 14 16 18 20 22 24 26
(kW) (m /h)
GVS16 - 20/1 2.2 19 18.5 18 17 16 15 14 13 11
GVS16 - 20 4 38 37.5 37 36 34 32 30 27 24
GVS16 - 30 5.5 57 56 55 54 51 48 45 40 36
GVS16 - 40 7.5 H 76 75 73 72 68 64 60 54 49
GVS16 - 50 11 (m) 96 94 92 90 85 80 75 68 62
GVS16 - 60 11 115 113 111 108 102 96 91 82 75
GVS16 - 70 15 135 132 129 126 119 113 106 96 88
GVS16 - 80 15 155 152 148 144 137 130 122 111 101
GVS16 - 100 18.5 197 192 187 181 174 165 153 141 127
M U LT I S T A G E S T A I N L E S S S T E E L C E N T R I F U G A L P U M P