LCP Ultradeck® 508
LCP Ultradeck® 508
LCP Ultradeck® 508
FEATURES
1
L C P U L T R A D E C K® 5 0 8
ARCHITECTURAL SPECIFICATION
The roofing and/or wall cladding metal sheets shall be 0.48mm BMT (i.e. 0.54mm TCT) or 0.60mm BMT (i.e. 0.66mm
TCT) LCP ULTRADECK® 508 as produced by LCP Building Products Pte. Ltd., with ribs of 45mm height spaced at 254mm
centres. The effective cover width for the metal sheets shall be 508mm.
The sheeting material shall be ZINCALUME® protected steel sheet to Australian Standard AS1397 with a minimum
yield stress of 550MPa (Grade G550), metallic hot-dip coated with ZINCALUME® zinc / aluminium alloy-coated steel
comprising 55% aluminium, 43.5% zinc and 1.5% silicon. The minimum coating mass for the ZINCALUME® zinc/aluminium
alloy - coated steel shall be AZ200 (200 g/m2 minimum coating mass) as determined by Australian Standard AS1397.
Wherever applicable, the installation of the metal sheets shall be in accordance to the “Installation code for metal
roofing and wall cladding; Standards Australia SAA HB39-1997”. The sheets shall be installed using concealed fixing
clips in accordance to manufacturer’s recommendations. The fasteners used to secure the fixing clips to the supports
shall conform to Australian Standard AS3566 and be compatible with the roofing material used. The clips shall be
concealed and no fasteners are to penetrate the cladding.
Sheets shall be laid in such a manner that the approved side lap faces away from the prevailing weather. A minimum
of 50mm shall be provided for projection into gutters. Flashings shall be supplied in compatible materials as specified,
minimum cover of flashing shall be 150mm.
All sheets shall be fixed in a workman like manner, leaving the job clean and weather-tight. All debris (nuts, screws,
cuttings, filings etc.) shall be cleaned off daily.
2
L C P U L T R A D E C K® 5 0 8
TYPICAL ROOF
INSTALLATION
All roof slopes require a turn up at the top of the sheet,
and also need to be turned down at the low end. This
is best achieved using a LCP ULTRADECK® 508 Stop
Ending Tool.
For maximum protection from weather intrusion the
sheets should be laid with the exposed edge of the
overlaps away from the direction of the prevailing
weather.
To commence installation, the first row of clips should
be fixed in line ensuring that the “arrow” is pointing
in the direction of laying. Check the alignment of the
clips either using a string line or the edge of sheet as a
guide. Lay the first sheet over the clips and snap home
both the centre rib and the female rib (in cyclonic
regions the first female rib must be mechanically
fastened through to the clip).
The second row of clips can then be rotated into place over the male rib of the first sheet and fastened in position.
The second sheet is then snapped home over the clip as before, ensuring that the female rib of the second sheet is
fully engaged along the full length over the male rib of the first sheet.
This procedure is then continued for all the sheeting. Finally a finishing clip (do not use an internal clip) is placed over
the male rib of the last sheet and fastened both to the purlin and the sheet rib.
FOOT TRAFFIC
When walking on LCP ULTRADECK® 508 always wear clean, non-marking and flat rubber soled shoes. Avoid
unnecessary foot traffic and walk on the flat of the panel at or near the supporting roof structural members as much
as possible. Do not use the roof panel as a working platform.
3
L C P U L T R A D E C K® 5 0 8
TECHNICAL SPECIFICATION
PROPERTIES
LCP ULTRADECK® 508 Mass/Thickness Chart
Thickness Material Mass kg/m2 of Roof Cover
BMT (mm) TCT* (mm) Zincalume® Galvanised Colorbond®
0.48 0.54 5.36 5.78 5.68
0.60 0.66 6.64 7.02 7.00
*TCT (Total Coated Thickness) values are based on ZINCALUME® coating and are nominal only.
The above chart is based on straight roof only. For sprung curve span, please contact LCP technical department.
*For optimum spanning capacity, end spans are shorter than internal spans in a fixed ratio, (End Span = 0.8 ×
Internal Span). The Internal/End Span combinations shown must only be used in this specific ratio, rounded to the
nearest 50mm.
PERFORMANCE
4
MANUFACTURING and CONSTRUCTION
ORDERING FLASHING
When ordering, please have the following information Standard flashings are readily available for use with
available to ensure a speedy processing of your requirements: LCP ULTRADECK®0508 roofing. LCP Building Products Pte. Ltd.
will give design advice for flashing details and will manufacture
Customer/Company name, address, phone number & fax the required flashing.
number.
IMPORTANT NOTE: The information published in this brochure is as far as possible accurate at the date of publication, however, prior to
application in a particular situation, LCP Building Products Pte. Ltd. recommends that you obtain qualified expert advice confirming
the suitability of product(s) in question for the application proposed. While LCP Building Products Pte. Ltd. accepts its legal obligations,
be aware however that to the extent permitted by law, LCP Building Products Pte. Ltd. disclaims all liability (including liability for
negligence) for all losses and damages resulting from the use of the information provided in this brochure.
SPEED DECK® 508 is a registered trademarks of Stramit Corporation Pty. Limited.
LCP BUILDING PRODUCTS PTE. LTD. LCP BUILDING PRODUCTS PVT. LTD. Photographs of the premises displayed in
CO. No. 200009173 C (CO. No. U28112 TN2004 PTC053236) this Brochure are not to be construed as an
endorsement or recommendation by the owners
No. 6 Gul Circle, Singapore 629562 “Swathi Court”, Flat No. 4-B, 2nd Floor, Old of the premises to LCP and its products.
No. 22, New No. 43, Vijayaraghava Road, LCP ULTRADECK® 508 Brochure 03/17 ©2017 LCP
BUILDING PRODUCTS Tel: (65) 6865-1550 Fax: (65) 6861-4218 T. Nagar, Chennai 600 017, India Building Products Pte. Ltd. All rights reserved.
Email: lcp@lcp.sg website: www.lcp.sg
LCP ULTRADECK® 508 Brochure 03.2017 edition.
Tel: +91 44 2815 4406/08
Fax: +91 44 2815 4407 ZINCALUME®, COLORBOND® and Clean COLORBOND®
Email: lcpindia@lcpgroup.asia are registered trademarks of BLUESCOPE STEEL
website: www.lcpindia.com LIMITED