Hydrovane HV01RM
Hydrovane HV01RM
Hydrovane HV01RM
The innovative rotary vane principle is simple and highly efficient, designed to meet
customer needs and offers the perfect business solution for reliable high quality
compressed air and gas.
Design and manufacturing is based in the UK utilising the latest Computer Aided Design
software and machining centre technology.
How it works
A Air is drawn in through the intake valve.
Tripod HV01 - - - 0.12 (4) 1.1 1450 1.0 0.375 270 700 470 62 41
Mounted
HV02 - - - 0.24 (8) 2.2 2900 1.0 0.375 270 700 470 69 41
HV01RM - - - 0.12 (4) 1.1 1450 1.0 0.375 300 1120 730 62 77
Receiver
HV02RM - - - 0.24 (8) 2.2 2900 1.0 0.375 300 1120 730 69 77
Mounted
HV04RM - - - 0.54 (20) 4.0 1450 1.8 0.5 455 1410 990 73 145
HV04 0.66 (24) - - 0.54 (20) 4.0 1450 3.0 0.75 635 500 1050 66 181
HV05 0.90 (32) - - 0.72 (25) 5.5 1450 3.0 0.75 635 500 1050 66 186
HV07 1.26 (44) - - 1.02 (35) 7.5 1450 3.0 0.75 635 500 1050 67 197
HV11 - - 1.74 (61) 1.50 (52) 11.0 1450 7.0 0.75 825 700 1510 69 384
HV15 - - 2.28 (81) 1.98 (71) 15.0 1450 7.0 0.75 825 700 1510 70 397
Vertical
HV18 - - 2.94 (104) 2.55 (90) 18.0 1450 7.5 1.0 825 700 1510 70 481
HV22 - - 3.60 (127) 3.12 (110) 22.0 1450 7.5 1.0 825 700 1510 71 494
HV30 - - 5.15 (182) 4.59 (162) 30.0 1450 23.0 1.5 1115 900 1592 73 857
HV37 - - 5.95 (210) 5.30 (187) 37.0 1450 23.0 1.5 1115 900 1592 73 911
HV45 - - 7.33 (259) 6.54 (231) 45.0 1450 23.0 1.5 1115 900 1592 73 940
HV55 - 9.48 (335) - - 55.0 1450 45.0 1.5 955 2330 1600 71 1450
Enclosed
HV75 - 12.66 (447) - - 75.0 1450 45.0 1.5 955 2330 1600 73 1450
HV07RS 0 to 1.30 (46) - 6 to 10 bar 7.5 up to 2220 3.0 0.75 635 500 1050 67 204
HV11RS 0 to 1.87 (66) - 6 to 10 bar 11.0 up to 1900 7.0 0.75 825 700 1510 69 393
HV15RS 0 to 2.46 (87) - 6 to 10 bar 15.0 up to 1800 7.0 0.75 825 700 1510 70 406
HV18RS 0 to 3.12 (110) - 6 to 10 bar 18.0 up to 1800 7.5 1.0 825 700 1510 70 507
Regulated
Speed HV22RS 0 to 3.88 (137) - 6 to 10 bar 22.0 up to 1800 7.5 1.0 825 700 1510 71 520
HV30RS 0 to 5.58 (197) - 6 to 10 bar 30.0 up to 1700 23.0 1.5 1115 900 1592 73 909
HV37RS 0 to 6.46 (228) - 6 to 10 bar 37.0 up to 1700 23.0 1.5 1115 900 1592 73 963
HV45RS 0 to 7.93 (280) - 6 to 10 bar 45.0 up to 1700 23.0 1.5 1115 900 1592 73 992
HV75RS 0 to 13.42 (474) - 6 to 8 bar 75.0 up to 1870 45.0 1.5 955 2330 1600 73 1560
HV01- 04 (1 - 4kW)
Key Features
Model Maximum FAD Motor Motor Oil Air Dimensions (mm) Noise Weight
m3/min (cfm) Power Speed Capacity Outlet Depth Width Height dB(A) (kg)
10 bar (kW) (rpm) (l) (Rp)
HV01 0.12 (4) 1.1 1450 1.0 0.375 270 700 470 62 41
Tripod
Mounted HV02 0.24 (8) 2.2 2900 1.0 0.375 270 700 470 69 41
HV01RM 0.12 (4) 1.1 1450 1.0 0.375 300 1120 730 62 77
Receiver HV02RM 0.24 (8) 2.2 2900 1.0 0.375 300 1120 730 69 77
Mounted
HV04RM 0.54 (20) 4.0 1450 1.8 0.5 455 1410 990 73 145
Free Air Delivered (FAD) according to ISO1217:2009
industry revolves around
HV04 - 45 (4 - 45kW)
The vertical Hydrovane compressor is a totally new concept building on the proven
vane technology that has been continually developed over the last 50 years.
Key Features
Model Maximum FAD m3/min (cfm) Motor Motor Oil Air Dimensions (mm) Noise Weight
Power Speed Capacity Outlet dB(A) (kg)
7 bar 8 bar 10 bar (kW) (rpm) (l) (Rp) Depth Width Height
HV04 0.66 (24) - 0.54 (20) 4.0 1450 3.0 0.75 635 500 1050 66 181
HV05 0.90 (32) - 0.72 (25) 5.5 1450 3.0 0.75 635 500 1050 66 186
HV07 1.26 (44) - 1.02 (35) 7.5 1450 3.0 0.75 635 500 1050 67 197
HV11 - 1.74 (61) 1.50 (52) 11.0 1450 7.0 0.75 825 700 1510 69 384
HV15 - 2.28 (81) 1.98 (71) 15.0 1450 7.0 0.75 825 700 1510 70 397
HV18 - 2.94 (104) 2.55 (90) 18.0 1450 7.5 1.0 825 700 1510 70 481
HV22 - 3.60 (127) 3.12 (110) 22.0 1450 7.5 1.0 825 700 1510 71 494
HV30 - 5.15 (182) 4.59 (162) 30.0 1450 23.0 1.5 1115 900 1592 73 857
Free HV37 - 5.95 (210) 5.30 (187) 37.0 1450 23.0 1.5 1115 900 1592 73 911
Standing HV45 - 7.33 (259) 6.54 (231) 45.0 1450 23.0 1.5 1115 900 1592 73 940
Vertical
HV07RS 0 to 1.30 (46) - 6 to 10 bar 7.5 up to 2220 3.0 0.75 635 500 1050 67 204
HV11RS 0 to 1.87 (66) - 6 to 10 bar 11.0 up to 1900 7.0 0.75 825 700 1510 69 393
HV15RS 0 to 2.46 (87) - 6 to 10 bar 15.0 up to 1800 7.0 0.75 825 700 1510 70 406
HV18RS 0 to 3.12 (110) - 6 to 10 bar 18.0 up to 1800 7.5 1.0 825 700 1510 70 507
HV22RS 0 to 3.88 (137) - 6 to 10 bar 22.0 up to 1800 7.5 1.0 825 700 1510 71 520
HV30RS 0 to 5.58 (197) - 6 to 10 bar 30.0 up to 1700 23.0 1.5 1115 900 1592 73 909
HV37RS 0 to 6.46 (228) - 6 to 10 bar 37.0 up to 1700 23.0 1.5 1115 900 1592 73 963
HV45RS 0 to 7.93 (280) - 6 to 10 bar 45.0 up to 1700 23.0 1.5 1115 900 1592 73 992
T. +44 (0) 1527 525522 F. +44 (0) 1527 521140 E. hydrovane-info.uk@gardnerdenver.com www.hydrovane.co.uk
© Gardner Denver Ltd 2010
GB08.10
industry revolves around
Fully enclosed, the direct drive compressor takes full advantage of the latest
microprocessor technology for total compressor control.
Key Features
Model Maximum FAD Motor Motor Oil Air Dimensions (mm) Noise Weight
m3/min (cfm) Power Speed Capacity Outlet Depth Width Height dB(A) (kg)
7.5 bar (kW) (rpm) (l) (Rp)
HV55 9.48 (335) 55.0 1450 45.0 1.5 955 2330 1600 71 1450
HV75 12.66 (447) 75.0 1450 45.0 1.5 955 2330 1600 73 1450
Enclosed
0 to 13.42 (474)
HV75RS 75.0 up to 1870 45.0 1.5 955 2330 1600 73 1560
6 to 8 bar
Key Features
• Energy savings typically 30% to 50%
Model Maximum FAD Pressure Motor Motor Oil Air Dimensions (mm) Noise Weight
m3/min (cfm) Range Power Speed Capacity Outlet dB(A) (kg)
(bar) (kW) (rpm) (l) (Rp) Depth Width Height
HV07RS 0 to 1.30 (46) 6 to 10 bar 7.5 up to 2220 3.0 0.75 635 500 1050 67 204
HV11RS 0 to 1.87 (66) 6 to 10 bar 11.0 up to 1900 7.0 0.75 825 700 1510 69 393
HV15RS 0 to 2.46 (87) 6 to 10 bar 15.0 up to 1800 7.0 0.75 825 700 1510 70 406
HV18RS 0 to 3.12 (110) 6 to 10 bar 18.0 up to 1800 7.5 1.0 825 700 1510 70 507
Regulated
HV22RS 0 to 3.88 (137) 6 to 10 bar 22.0 up to 1800 7.5 1.0 825 700 1510 71 520
Speed
HV30RS 0 to 5.58 (197) 6 to 10 bar 30.0 up to 1700 23.0 1.5 1115 900 1592 73 909
HV37RS 0 to 6.46 (228) 6 to 10 bar 37.0 up to 1700 23.0 1.5 1115 900 1592 73 963
HV45RS 0 to 7.93 (280) 6 to 10 bar 45.0 up to 1700 23.0 1.5 1115 900 1592 73 992
HV75RS 0 to 13.42 (474) 6 to 8 bar 75.0 up to 1870 45.0 1.5 955 2330 1600 73 1560
T. +44 (0) 1527 525522 F. +44 (0) 1527 521140 E. hydrovane-info.uk@gardnerdenver.com www.hydrovane.co.uk
© Gardner Denver Ltd 2010
GB08.10
industry revolves around
• Horizontal receiver (75 litre for 1 and 2kW, 200 litre for 4kW)
• Hydrovane direct drive horizontal compressor
• Aftercooler for primary water separation
• Membrane dryer technology
• CF series filtration
• Automatic stop start
• Fully connected and ready to run.
Compressor Model Maximum FAD m3/min (cfm) Motor Motor Oil Air Noise Weight
Performance Power Speed Capacity Outlet dB(A) (kg)
7 bar 8 bar 10 bar (kW) (rpm) (l) (Rp)
Horizontal HV01RM - - 0.12 (4) 1.1 1450 1.0 0.375 62 77
Membrane HV02RM - - 0.24 (8) 2.2 2900 1.0 0.375 69 77
Range HV04RM - - 0.54 (20) 4.0 1450 1.8 0.5 73 145
HV04 0.66 (24) - 0.54 (20) 4.0 1450 3.0 66 181
HV05 0.90 (32) - 0.72 (25) 5.5 1450 3.0 66 186
Vertical HV07 1.26 (44) - 1.02 (35) 7.5 1450 3.0 0.75 67 197
Refrigerant HV11 - 1.74 (61) 1.50 (52) 11.0 1450 7.0 69 384
Range HV15 - 2.28 (81) 1.98 (71) 15.0 1450 7.0 70 397
HV18 - 2.94 (104) 2.55 (90) 18.0 1450 7.5 70 481
1.0
HV22 - 3.60 (127) 3.12 (110) 22.0 1450 7.5 71 494
HV07RS 0 to 1.30 (46) - 6 to 10 bar 7.5 up to 2220 3.0 67 204
Regulated HV11RS 0 to 1.87 (66) - 6 to 10 bar 11.0 up to 1900 7.0 0.75 69 393
Speed
HV15RS 0 to 2.46 (87) - 6 to 10 bar 15.0 up to 1800 7.0 70 406
Refrigerant
Range HV18RS 0 to 3.12 (110) - 6 to 10 bar 18.0 up to 1800 7.5 70 507
1.0
HV22RS 0 to 3.88 (137) - 6 to 10 bar 22.0 up to 1800 7.5 71 520
Hypac Model Package Dimensions (mm) Package Weights (kg) Ambient Receiver Dryer Pressure Air Air
Performance Depth Width Height Horizontal Vertical Temp. Capacity Type Dew Cleanliness Outlet
HV01/HV02 4kW 5kW 7kW 11kW 15kW 18kW 22kW 7kW 11kW 15kW 18kW 22kW min - max (l) 3
Point (mg/m ) (Rp)
HV04 RS RS RS RS RS (°C) (°C)
Horizontal HV01RM 300 1120 730 93 - - - - - - - - - - - - 75 30* 0.01 0.375
Membrane HV02RM 300 1120 730 93 - - - - - - - - - - - - 0 - 40 75 Membrane 30* 0.01 0.375
Range HV04RM 455 1410 990 156 - - - - - - - - - - - - 200 30* 0.01 0.5
HV04-HV07RS
ACER 741 1570 1520 - 306 311 322 - - - - 329 - - - - 250 8 <2
ACED 741 900 1100 - 223 229 240 - - - - 247 - - - - - 3 <1
AERD 741 1570 1520 - 348 354 365 - - - - 372 - - - - 250 3 <1
HV11-HV11RS
ACER 1187 1355 1510 - - - - 521 - - - - 528 - - - 272 8 <2
ACED 825 1215 1510 - - - - 446 - - - - 453 - - - - 3 <1
AERD 1187 1355 1510 - - - - 586 - - - - 593 - - - 272 3 <1
HV15-HV15RS
Vertical ACER 1187 1355 1510 - - - - - 534 - - - - 541 - - 272 8 <2
Refrigerant ACED 825 1215 1510 - - - - - 459 - - - - 466 - - - Refrigerant 3 <1 0.75
0 - 45**
Range
AERD 1187 1355 1510 - - - - - 599 - - - - 606 - - 272 3 <1
HV18 -HV18RS
ACER 1187 1355 1510 - - - - - - 618 - - - - 644 - 272 8 <2
ACED 825 1215 1510 - - - - - - 543 - - - - 569 - - 3 <1
Free Air Delivered (FAD) AERD 1187 1355 1510 - - - - - - 683 - - - - 709 - 272 3 <1
according to ISO1217:2009
HV22-HV22RS
ACER 1187 1355 1510 - - - - - - - 631 - - - - 657 272 8 <2
*Below ambient ACED 825 1215 1510 - - - - - - - 556 - - - - 582 - 3 <1
**Regulated Speed (RS) units
AERD 1187 1355 1510 - - - - - - - 696 - - - - 722 272 3 <1
operate to ambient temperature
up to 40°C
Gardner Denver Ltd
Claybrook Drive, Washford Industrial Estate, Redditch, Worcs B98 0DS, UK
© Gardner Denver Ltd 2010
T. +44 (0) 1527 525522 F. +44 (0) 1527 521140 E. hydrovane-info.uk@gardnerdenver.com www.hydrovane.co.uk
GB08.10
industry revolves around
Key Features
• Maximum air delivery at minimum cost
• IP55 Class F Motor directly driving the well proven Hydrovane air end
Model Maximum FAD Motor Motor Oil Air Dimensions (mm) Noise Weight
m3/min (cfm) Power Speed Capacity Outlet Depth Width Height dB(A) (kg)
8 bar 10 bar (kW) (rpm) (l) (Rp)
HV11 PEAS 1.74 (61) 1.50 (52) 11.0 1450 8.5 0.75 1677 741 830 75 320
Open HV15 PEAS 2.28 (81) 1.98 (71) 15.0 1450 8.5 0.75 1677 741 830 76 330
HV18 PEAS 2.94 (104) 2.55 (90) 18.0 1450 9.0 1 1850 792 906 77 410
HV22 PEAS 3.60 (127) 3.12 (110) 22.0 1450 9.0 1 1850 792 906 78 425
Key Features
• Maximum air delivery at minimum cost
• IP23 Class F Motor directly driving the well proven Hydrovane air end
• Integral aftercooler
• 30kW - Combined Air and Oil cooler (Combi)
• 37kW and 45kW - Separate Air and Oil coolers
Model Maximum FAD Motor Motor Oil Air Dimensions (mm) Noise Weight
m3/min (cfm) Power Speed Capacity Outlet Depth Width Height dB(A) (kg)
8 bar 10 bar (kW) (rpm) (l) (Rp)
HV30 PEAS 5.15 (182) 4.59 (162) 30.0 1450 23.0 1.5 1917 812 860 82 585
Open HV37 PEAS 5.95 (210) 5.30 (187) 37.0 1450 23.0 1.5 1917 892 1106 84 690
HV45 PEAS 7.33 (259) 6.54 (231) 45.0 1450 23.0 1.5 1917 892 1106 85 710
T. +44 (0) 1527 525522 F. +44 (0) 1527 521140 E. hydrovane-info.uk@gardnerdenver.com www.hydrovane.co.uk
© Gardner Denver Ltd 2010
GB08.10
industry revolves around
Key benefits
• Warranty for 10 years or 48,000 hours - Complete peace of mind**
• Free of charge - No premiums to pay
• Planned maintenance schedules - Maximum production
• Known revenue costs - No unexpected repair bills
• Simple to join with minimum administration - No fuss, no complication.
Customer requirements
• Purchase a new Hydrovane compressor from an authorised Hydrovane distributor
• Have the installation approved by an authorised Hydrovane distributor
• Enter into a service agreement with an authorised Hydrovane distributor
• Set up regular servicing as detailed in the service schedule
• Use genuine Hydrovane parts and lubricants for service
• Register for the Hydrovane Advance warranty programme.
Hydrovane commitment
• An appropriate service package will be agreed
• Trained and qualified engineers will be used.
Re-Advance
An opportunity for Hydrovane customers to join the Hydrovane Advance
warranty programme and achieve up to 10 years full warranty cover, subject to the following:
Standard Warranty
All Hydrovane compressors are guaranteed for 12 months from date of installation providing
the installation is approved by an authorised Hydrovane distributor and the correct service procedures
and genuine parts are used.
Servicing kits
The kit concept has been developed to make servicing quick, easy and
reliable. Hydrovane kits have been carefully constructed to contain all of the
parts required for an effective preventative maintenance programme. Using
the kits as part of the recommended service schedule will prevent costly
breakdowns, ensuring a continuous supply of high quality compressed air.
Lubricants
Hydrovane lubricants have been developed over many years specifically for
Hydrovane compressors. The range has been specially formulated to ensure
peak operating efficiency, guaranteeing optimum compressor performance.
Under the Fluid Force brand the lubricants offer high quality solutions
for a wide range of compressor applications:
Training
The company is committed to providing the Hydrovane owner with fully
trained engineers to care for their investment. In our fully equipped training
school we instruct our distributors service engineers on the correct
procedures of service and repair. Engineers are taught the theory of
compression, the principles of valve operation combined with practical
training on installed and fully operational compressors.
All engineers must pass a written examination and only then are presented
with a qualifying certificate of competence.
Annually, engineers are required to attend update courses to ensure they are
always fully aware of the latest products and improvements.
T. +44 (0) 1527 525522 F. +44 (0) 1527 521140 E. hydrovane-info.uk@gardnerdenver.com www.hydrovane.co.uk
© Gardner Denver Ltd 2010
GB08.10
www.hydrovane.co.uk
industry revolves around
Claybrook Drive, Washford Industrial Estate,
Redditch, Worcs B98 0DS, UK
98700508E-08/2010
© Gardner Denver Ltd 2010