FE1-FE1 ETH Converter User Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

FE1-FE1*ETH Converter

User Manual
FE1-FE1*ETH User Manual

1 General Safety Information


Please read the following safety rules to avoid any harm to human body and any damage to
other devices when this device is connected to other devices. The product shall be used in
specified applicable areas and shall be fixed by technical engineer authorized by us.
To prevent fire and to avoid any harm to human body, please
 Use the appropriate power supply, check power supply type and differentiate anode and
cathode carefully;
 Connect and cut-off properly: when device is powered, do not connect or cut off the data
cable;
 Use proper grounding: before using the product, make sure the proper grounding is made ,
grounding impendence shall be less than 4ohm;
 Make the correct connection: ensure to use the default accessories provided along with
the device. If you need to make the special connection, please note the PIN definition and
make the proper connection;
 Avoid to touch exposed circuit When the circuit is on, do not touch exposed components if
any;
 Do not operate the device without front panel;
 Provide good ventilation;
 Do not operate the device in the humid environment;
 Do not operate the device in the volatile environment;
 Keep the surface clean and dry.

2. Fast track
FE1-FE1*ETH converter can combine and multiplex an Ethernet and an E1( user side) into
an E1 channel and transmit through E1 channel. The bit rate of E1 and Ethernet can be
adjusted provided the total bit rate does not exceed the E1 bit rate (1984Kbps).
E1-M is uplink channel; E1-S is downlink channel. The PCB for standalone and rack
version is same. Please indicate your requirement when order. The following are the operation
steps:
 Connect with appropriate power supply as per back panel power indication; Power on, the
device will do self-detection, PWR,E1LOS-M,E1LOS-S indicators shall be on, rest shall be
off;
 Connect Rx of E1-M with Tx of E1 channel on transmission equipment, Tx to Rx ;
E1LOS-M alarm indicator shall be off; if there is an error, you can press button to pinpoint
the error;
 Based on client’s need, configure the time-slot of E1-S, connect E1 line to TX ,RX of E1-S,
the E1LOS-S indicator shall be off;
 Based on Ethernet transmission requirement set up fixed timeslots (through 17~22th
dipswitch), connect Ethernet cable, the LINK indicator shall be on, SPD,F/D indicator
status shall be as per Ethernet working mode;
 If you operate as per above steps, the device still does not work, please contact your
supplier or our technical staff for assistance.

3. Product Features

2
FE1-FE1*ETH User Manual

 Provide rich auto-operation and auto-calculation options. Users can configure the device
easily;
 Self-learn Ethernet MAC address, decide forward or filter the data frame based on sourc
MAC address and destination MAC address;
 Ethernet data rate can be configured based on E1-S data rate configuration;
 Local device can follow the configuration of remote device automatically or users can
command remote device to follow local configuration;
 Provide rich alarming and loop testing function;

4. Technical Specifications
E1 Interface
 Data rate: N*64Kbit/s (N=1-31)
 Coding: HDB3
 Impedance: 75Ω(unbalanced)/120Ω(RJ48-C balanced)
 Standard: compliant with G.703、G.704
 Jitter: compliant with G.832
 Connector: Q9/RJ45
 Alarm Indicators: code breaking, frame loss, CRC alarm, AIS
Ethernet
Interface data rate: N*64Kbit/s、N=1-31、
Transmission speed: 10/100M auto negotiation
Duplex mode: full/hall duplex auto negotiation
Power supply:
Voltage: Stand-alone AC 220V/DC -48V optional
Chassis-based: AC220V/DC-48V、hot redundancy and swappable;
Voltage range: 180 VAC、260 VAC or -38 VDC 、 -72 VDC
Power consumption: stand-alone: <5W
Chassis-based: <75W
Dimension:
Stand-alone mini type: 218mm*136mm*44mm , 2 sets can be mounted on 1 19” rack
Chassis-based: 483mm*165mm*177mm
Operating environment:
Working Temp.: -20、 、 +70、
Humidity: 95%

5. Front panel

5.1 Indicators
There are 9 indicators on the front panel
Indicator
Device Status
Name Function Status

3
FE1-FE1*ETH User Manual

Power supply ON Power supply normal


PWR
indicator OFF No power supply
One of the testing button is
Testing status Blinking
TEST pressed at local or remote end
indicator
OFF Normal
ON E1 link code error alarm
Blinking AIS alarm
E1LOS-S~E1LOS-M E1 link alarm Intermittent
Remote device alarm
blinking
OFF E1 link normal
ON E1 frame not synchronized
Blinking CRC-4 error checking
E1 data flow alarm
E1SYL-S~E1SYL-M Intermittent Remote device frame not
indicator
blinking synchronized
OFF E1 data receiving normal
Ethernet Link ON Ethernet connected
LINK
indicator OFF Ethernet not connected
Ethernet data rate ON Ethernet data rate: 100Mbps
SPD
indicator OFF Ethernet data rate: 10Mbps
Ethernet Duplex ON Full duplex
F/D
mode indicator OFF Half duplex
5.2 Push button
There are 4 push buttons on the front panel;
ANA: Loop from local E1-M to E1-S/ETH , used to check if local link is ok or not;

DIG Loop from local E1-S/Eth to E1-M , used to check remote E1 link and remote device;

REM Remote E1-S/ETH loop, the status of REM as follow:

PATT Invalid
Note: when any one of button is pressed, the normal data communication will be terminated,

4
FE1-FE1*ETH User Manual

TEST indicator will be ON.


5.3 Dip Switch
There are 3 group of dipswitch on the front panel, the definition of 1~24th position is as follow:

S.No Description Configuration


Starting time slot of 0~31 time slots of E1-M see table 1;
1~5
E1-M set by E1-S When all set OFF, means starting time slot is 0;
6~8 Invalid reserved
The time-slot Detailed configuration see table 2;
9~13 number of E1-M set When time-slot number is 0, means E1-S is not
by E1-S used;
14 Invalid reserved
Framed mode When this position set to ON, framed mode is
15
enabled enabled
Close E1LOS-S 、 When connected with remote E1 multiplexer, remote
16 E1SYL-S blinking E1 device is not E1-S interface, E1LOS-S blinks. Set
alarm this position to ON to close this function;
Ethernet Time-slot Corresponding Ethernet time-slot number, from 0 to
number in E1-M 31 ,in E1-M, see table 3; When time-slot number is
17~21 0, means Ethernet is not used; When the Ethernet
time-slot number is automatically configured, above
setup is invalid;
Close automatic OFF-automatic configuration
Ethernet time-slot ON- Close automatic configuration
number When the device is in the automatic configuration
22
configuration mode, based on the 15th dipswitch setup, the
time-slot numbers in E1-M is what left by E1-S time
slot numbers
Command remote --Valid when set as ON;
device to follow local --If this position is valid, all dipswitch except 6th and
‘s configuration 23rd dipswitch are invalid for remote device;
--if this position of local and remote are both set as
23
ON, wrong configuration will be reported;
--If 23rd,24th dipswitch of local device are set as
ON, remote alarm message will not be sent to
remote device;
Command local --valid when set as ON;
device to follow --if this position is valid, all dipswitch except 6th
remote’s and 24th dipswitch are invalid for local device;
24 configuration
----If 23rd,24th dipswitch of local device are set as
ON, remote alarm message will not be sent to
remote device;

5
FE1-FE1*ETH User Manual

Table 1: 1~5 dipswitch starting time-slot configuration


rd
**when starting time-slot is 3, E1-S will count time-slot number from 3 position;
5 4 3 2 1 Starting time-slot
OFF OFF OFF OFF ON 1
OFF OFF OFF ON OFF 2
OFF OFF OFF ON ON 3
OFF OFF ON OFF OFF 4
OFF OFF ON OFF ON 5
OFF OFF ON ON OFF 6
OFF OFF ON ON ON 7
OFF ON OFF OFF OFF 8
OFF ON OFF OFF ON 9
OFF ON OFF ON OFF 10
OFF ON OFF ON ON 11
OFF ON ON OFF OFF 12
OFF ON ON OFF ON 13
OFF ON ON ON OFF 14
OFF ON ON ON ON 15
ON OFF OFF OFF OFF 16
ON OFF OFF OFF ON 17
ON OFF OFF ON OFF 18
ON OFF OFF ON ON 19
ON OFF ON OFF OFF 20
ON OFF ON OFF ON 21
ON OFF ON ON OFF 22
ON OFF ON ON ON 23
ON ON OFF OFF OFF 24
ON ON OFF OFF ON 25
ON ON OFF ON OFF 26
ON ON OFF ON ON 27
ON ON ON OFF OFF 28
ON ON ON OFF ON 29
ON ON ON ON OFF 30
ON ON ON ON ON 31

Table 2: 9~13 17~21 dipswitch configuration and data rate


13 12 11 10 9 Data rate
、21、 、20、 、19、 、18、 、17、 Kbit/s
OFF OFF OFF OFF ON 64
OFF OFF OFF ON OFF 128
OFF OFF OFF ON ON 192
OFF OFF ON OFF OFF 256

6
FE1-FE1*ETH User Manual

OFF OFF ON OFF ON 320


OFF OFF ON ON OFF 384
OFF OFF ON ON ON 448
OFF ON OFF OFF OFF 512
OFF ON OFF OFF ON 576
OFF ON OFF ON OFF 640
OFF ON OFF ON ON 704
OFF ON ON OFF OFF 768
OFF ON ON OFF ON 832
OFF ON ON ON OFF 896
OFF ON ON ON ON 960
ON OFF OFF OFF OFF 1024
ON OFF OFF OFF ON 1088
ON OFF OFF ON OFF 1152
ON OFF OFF ON ON 1216
ON OFF ON OFF OFF 1280
ON OFF ON OFF ON 1344
ON OFF ON ON OFF 1408
ON OFF ON ON ON 1472
ON ON OFF OFF OFF 1536
ON ON OFF OFF ON 1600
ON ON OFF ON OFF 1664
ON ON OFF ON ON 1728
ON ON ON OFF OFF 1792
ON ON ON OFF ON 1856
ON ON ON ON OFF 1920
ON ON ON ON ON 1984

6 Rear panel

6.1 power supply


The device supports AC220V/DC-48V, you can choose power supply based on your
requirement;
When power switch is switched “48V”, means you want to use -48VDC power supply; when
the power switch is switched to “220VAC”, means you want to use 220VAC power supply;
When you use -48VDC power supply, you shall connect cathode of DC power supply to
cathode of the device, anode of DC power supply to anode of device ;
6.2 E1 connector
75Ω/RX、 75Ω unbalanced input

7
FE1-FE1*ETH User Manual

75Ω/TX、 75Ω unbalanced E1 output;


“M” mark means uplink E1 channel, “S” mark means downlink user side E1 channel;
6.3 Ethernet Interface (LAN interface)
Ethernet interface supports cross-connection and cut-through auto-sensing;
Note: when LAN cable is too long , please make sure to connect two PIN of RX into a same UTP,
two PIN of TX into a same UTP;
6.4 Bottom panel

ON、 means grounding of E1 link is connected with grounding of system;


OFF、means grounding of E1 link is disconnected with grounding of system;
The first position is RX grounding, the second position is TX grounding;
Note : please make sure there shall be at least one side to be grounded. For example: if
transmission equipment’s TX is grounded, our device is not necessary to be grounded; If
transmission equipment is not grounded, our deviced shall be gournded;

7. Rack
7.1 Front panel

Front panel
There are 17 slots, 15 for NMS card and functional card, 2 for power supply card.
NMS Card:
If users need network management, the NMS card must be plugged into the first slot; if users do
not need network management, this slot can be used for functional card;
Function cards:
Maximum 15 functional cars can be plugged. Various functional cars can be used.
Power supply card:
Users can plug the power supply module based on the requirement, the power can be 220VAC,
-48VDC. 1+1 redundancy is supported.

7.2 Real panel

8
FE1-FE1*ETH User Manual

8. Typical application

1~5th dipswitch should be all OFF


6-8th dipswitch : reserved OFF
14 is invalide , it is resered
15th dipswith is also used to set PCM3 and PCM31
ON-PCM30
OFF-PCM31
16th dipswtich is used close the alarm of sub E1 is sub E1 is not connected to any E1
devices
22: OFF-automatical confirgure Etherent time slot ON-close automatic config
23: command remote device to follow local configuration, it's valid if ON
24: command local device to follow local config
normanlly make if OFF , 23,24
CRC check is always enalbed;