hi sir,
kindly advice, issue on my fuel purifiers, online the separator feed valve open discharge
clean fuel pressure is 2 bar, running i mints shut down for discharge water over flow
alarm, i already change all the seals on bowl, but still same alarm
thanks
Mohamed Malik
Top
Top
Top
hi sir,
fuel density 0.850 and temp 30,
no valve, all connection is same original with system, thanks
Top
Top
Hi Big Pete,
No, shortening de sludge interval not solving the problem. Other way our HFO quality is
good, sludge product rate is less. So there in no point to shorten the de sludge interval.
Thanks.
Jahirul
Top
Top
hi guys
I hve a problem with osd60-0136-067 hfo purifier. Our sludge production increase
suddenly and there is water in clean oil. We already changed seals and gaskets yet the
same outcome. We also observed that there is pressure in sludge port. Anyone can help
me out?
Thanks
Brian
Top
BP
Top
Display posts from previous: All posts Sort by Post time Ascending Go
Post Reply
• Print view
25 posts
• Previous
• 1
• 2
Return to “The Workshop”
Jump to
• The forum area of www.dieselduck.net
• Crew Mess
• The Workshop
• Training Room
• Events and Anouncements
• F.W.E
• Trading Post
• Website Area
• Marine Engineering Job Board and forum at www.dieselduck.net
• General Job topics
• Project Tango Charlie
• Available Positions
• Available Marine Engineers
• Available Marine Engineers looking for shore base work
• Available Marine Engineering Cadets / Apprentices, and experienced ER
professionals
Who is online
Users browsing this forum: No registered users and 1 guest
Tweets by @dieselduckster
Martin Leduc Retweeted