Cathodic Protection BOM
Cathodic Protection BOM
Cathodic Protection BOM
Anode: Magnesium ribbon anode with prepackaged length 2.2m and dia 10cm
Anode C/W 12Meters long 6mm2 THHN/THWN Cable. (Temporary anodes)
Anode: Magnesium ribbon anode with prepackaged length 2.2m and dia 10cm
Anode C/W 3Meters long 6mm2 THHN/THWN Cable. (Temporary anodes)
Potential test station: 5 terminals with shunt (0.01 Ohm) lockable Big Fink test
station, with a supplier dent lock, c/w 3” hot dip galvanized steel pipe and chain
PTS to hold the cap with stainless steel marker plate. Concrete foundation to be done
by contractor on site.
Cable Cables: 2x2.5 mm2 HMWPE P/L & Measuring connection
Cable Cables: 2x6 mm2 HMWPE
Split Bolt Split Bolt Connectors for 6 mm2 Cable
Pin Brazing 8mm Pin Brazing Charges
Charges
Ceramic 8mm Ceramic ferules
Ferules
Melt Stick Melt Stick Epoxy
Epoxy
Isolation coupling test station: 8 terminals with shunt (0.01 Ohm) lockable Big
Fink test station, with a supplier dent lock, c/w 3” hot dip galvanized steel pipe
ICTS and chain to hold the cap with stainless steel marker plate. Concrete foundation
to be done by contractor on site.
Current Test Station: 8 terminals with shunt (0.01 Ohm) lockable Big Fink test
station, with a supplier dent lock, c/w 3” hot dip galvanized steel pipe and chain
CTS to hold the cap with stainless steel marker plate. Concrete foundation to be done
by contractor on site.
Anode: Magnesium ribbon anode with prepackaged length 2.2m and dia 10cm
Anode C/W 18Meters long 6mm2 THHN/THWN Cable. (Temporary anodes)
Bonding Station: Two (2) terminals NEMA 4X and IP 55 bonding box complete
BB 2T with variable resistors c/w 2” Hot Dip Galvanized Steel conduit and hot dip
galvanize Support Channel (Rigid Steel).
Bonding Station: Three (3) terminals NEMA 4X and IP 55 bonding box complete
BB 3T with variable resistors c/w 2” Hot Dip Galvanized Steel conduit and hot dip
galvanize Support Channel (Rigid Steel).
Prep-packaged Permanent Reference Electrode Stelth Cu/CuSO4, C\W 15M long
Anode 1x6mm2 HMWPE Cable.
Anode: Magnesium 60Lb anode with prepackaged length 1.8m and dia 20cm
Anode C/W 15 Meters long 6mm2 THHN/THWN Cable.
Anode: Magnesium 60Lb anode with prepackaged length 1.8m and dia 20cm
Anode C/W 3 Meters long 6mm2 THHN/THWN Cable.
Road Crossing test station: 5 terminals with shunt (0.01 Ohm) lockable Big Fink
test station, with a supplier dent lock, c/w 3” hot dip galvanized steel pipe and
RCTS chain to hold the cap with stainless steel marker plate. Concrete foundation to be
done by contractor on site.
LUG Cable lugs for 2.5 mm2 (Opening 8mm)
LUG Cable lugs for 6 mm2 (Opening 8mm)
RECEIVED
UNIT QTY BALANCE
3/5/2019 ### ###
Each 84 84
Each 6 6
Each 22 22
Each 56 6 16 34 0
Each 21 21
Each 7 7
Each 7 6 1 0
Each 48 14 8 26
Each 48 14 8 26
Each 48 48