Document No : Equipment :
Page No : 1 of 3
PG/URS/001 OCTOGONAL BLENDER (500 LITERS)
Table of Contents
Sr. Page
Contents
No. No.
1.0 Introduction 2
2.0 Overview 2
3.2 Environment 3
4.1 Utilities 3
4.2 Availability 3
5.0 Glossary 3
6.0 References 3
7.0 Approval 3
info@pharmaguideline.com © www.pharmaguideline.com
Pharmaceutical Guidelines
USER’S REQUIREMENT SPECIFICATION
Document No : Equipment :
Page No : 2 of 3
PG/URS/001 OCTOGONAL BLENDER (500 LITERS)
1.0 Introduction: The Octogonal Blender 500 litre is used for mixing of dry mass as
per requirement.
2.0 Overview:
2.1 Intended use: The Octogonal Blender 500 litre will be used: for mixing of dry
mass as per the requirement.
2.2 Production Capacity: The capacity of the machine is to be: ………………..kg
depending on speed and size of the tablets.
2.3 Space Availability: Allocated floor space for the machine is 5500 mm X 4500 mm
and vertical clearance is 2500 mm.
2.4 Accuracy of instrumentation desired: Not Applicable
2.5 Cleaning requirements: Easy to clean
2.6 Equipment Specific Requirement
2.6.1 It should be designed to meet latest cGMP standards & should have low
maintenance cost.
2.6.2 The Octogonal Blender 500 litre having rotating shell with baffles.
2.6.3 All contact parts should be made up of SS 316 quality, internally mirror &
externally matt finished.
2.6.4 Octogonal Blender 500 litre should be provided having 30 to 100 revolutions
per minute.
2.6.5 It should have same charging port & discharge port.
2.6.6 It should have blender shaft drive.
2.6.7 There should be a safety guard around blender.
3.0 Operational Requirements
3.1 Functional Requirements
3.1.1 Operation
3.1.1.1 Operation shall be safe from an operator point.
3.1.2 Control System Requirements
3.1.2.1 There should be an “ON”, “OFF”, “INCH” switch.
3.1.2.2 It should be flame proof.
3.1.3 Power failure / Recovery
3.1.3.1 In the event of a power failure, the system shall stop automatically and will
require operator intervention to re-start.
3.1.4 Safety Requirements
3.1.4.1 MCB will be provided so that when there is an overload in current or any
short circuit then the MCB trips.