Catalog Hotstart IMC-600
Catalog Hotstart IMC-600
Catalog Hotstart IMC-600
Product Catalog
Engine Heaters Oil Heaters Controls Accessories
Tank Style Coolant Heaters That Meet Heating Requirements For a Wide Range of Engine Sizes and Applications.
Constant circulation of coolant through the engine achieves even heat distribution. One-piece, heavy-duty, pressure die-cast aluminum tank with a bolt-on flange element assembly. All parts replaceable easy to service. Most models classified weathertight. Many models available for Class I, Group D (Hazardous Locations) applications. Various voltages and phases available. CSA C/US and UL C/US approved.
Industrial Lube Oil Heaters and Process Oil Heaters. Multiple Sizes Available for Every Oil Heating Need.
Reduces engine wear. Immediate flow of warm oil to critical engine parts. Stops destructive condensation and the forming of sludge in oil. Warm oil allows easier starts and prolongs battery life. Models designed for heating transmission fluid, hydraulic oil and diesel fuel. Low watt density elements assure safe heating of oils and will not char or coke. Thermostat control available and recommended for all models. Innovative threadless design V-clamp style mounting adapter available. 2
Battery Warming Pads and Thermal Wraps Improve Cranking Power in the Coldest Conditions.
Flexible SBR rubber pads are designed for installation under the battery to heat from the bottom up. Blanket-style heaters and pad heaters are impervious to battery acid and oil. Pad models for multiple battery applications available with accessory cords and thermostat assembly. Blanket-style warmers provide greater heat rise than plates or pads. Engineered to maintain batteries at 80F/27c to ensure full cranking power.
Thermostat Controls, Complete Control Systems and Other Accessories Ensure Proper and Efficient Performance of Kim Hotstart Heaters.
General purpose, weathertight and explosion proof thermostats available for all engine heating, oil heating and battery heating applications. Fixed temperature and adjustable. Oil pressure switches for automatic cutoff of heaters on engine start-up. Complete control systems for 3 phase and high voltage engine preheaters factory assembled in electrical boxes for ease of installation.
All Direct Immersion Block Heaters Carry CSA C/US approval and are CE compliant.
Long life Incoloy elements withstand higher temperatures to reduce element failure. Reduced heat in terminal connection area. Resists scale build-up on element surface. Tensile strength of Incoloy is three times that of copper, making it much less susceptible to engine and road vibration. Available in 120 volt and 240 volt. The 6ft. power cord and plug carries a lifetime warranty; standard equipment on all in-block heaters. Optional thermostat control and Y harness available for all Kim-Glo heaters. 3
TABLE OF CONTENTS
Pages 6 -18
Section 1
Tank Style Coolant Heaters Weathertight Design Original Equip. Replacement Heaters Circulating System with Pump
Pages 20 - 24
Section 2
Tank Style Coolant Heaters Class 1, Group D for Hazardous Locations
Heater Installation Guides: Tank-style Page 40 In-block Page 56 How to Specify an Engine Heater and Conversion Charts Page 58 Industrial Circulating Systems Page 16, 17, 59 Pages 26 - 32 Section 3
Industrial Lube Oil Heaters Lube Oil Heaters with Thermostat Process Immersion Heaters with Fixed or Adjustable Thermostat
Pages 34 - 39
Section 4
Temperature Controls Pressure Switch Magnetic Contactors Junction Boxes Complete Control Systems
Pages 42 - 44
Section 5
Battery Warming Pads and Accessories Blanket Style Battery Warmers Silicone Hot Pads
Custom Products
Call for information on: Battery Chargers Wiring Harnesses Air Intake Heaters Diesel Driven Heating Systems Other Specialty Products
Pages 46 - 57
Section 6
In-block Direct Immersion Heaters In-line Coolant Heater Electrical Cords for In-block Heaters Thermocords Flush Mount Kits and Accessories
Section 1
Industrial Tank Style Coolant Heaters
Model Number TPS051GT8-000 TPS051GT10-000 TPS051GT12-000 TPS052GT8-000 TPS052GT10-000 TPS052GT12-000 TPS101GT8-000 TPS101GT10-000 TPS101GT12-000 TPS102GT8-000 TPS102GT10-000 TPS102GT12-000 TPS151GT8-000 TPS151GT10-000 TPS151GT12-000 TPS152GT8-000 TPS152GT10-000 TPS152GT12-000 TPS181GT8-000 TPS181GT10-000 TPS181GT12-000 TPS202GT8-000 TPS202GT10-000 TPS202GT12-000
Volts 120 120 120 240 240 240 120 120 120 240 240 240 120 120 120 240 240 240 120 120 120 240 240 240
Watts 500 500 500 500 500 500 1000 1000 1000 1000 1000 1000 1500 1500 1500 1500 1500 1500 1800 1800 1800 2000 2000 2000
Phase 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Amps 4.2 4.2 4.2 2.1 2.1 2.1 8.4 8.4 8.4 4.2 4.2 4.2 12.5 12.5 12.5 6.3 6.3 6.3 15 15 15 8.3 8.3 8.3
Thermostat Range On Off 80F 100F 120F 80F 100F 120F 80F 100F 120F 80F 100F 120F 80F 100F 120F 80F 100F 120F 80F 100F 120F 80F 100F 120F 100F 120F 140F 100F 120F 140F 100F 120F 140F 100F 120F 140F 100F 120F 140F 100F 120F 140F 100F 120F 140F 100F 120F 140F
HOTSTART TPS tank heaters are constructed from a durable, high-impact plastic. Every heater is assembled with a built-in thermostat and 4foot power cord.
Replacement Parts
For TPS Model heaters
Replacement Tank
Model Number TPS051GT8-000 TPS051GT10-000 TPS051GT12-000 TPS052GT8-000 TPS052GT10-000 TPS052GT12-000 TPS101GT8-000 TPS101GT10-000 TPS101GT12-000 TPS102GT8-000 TPS102GT10-000 TPS102GT12-000 TPS151GT8-000 TPS151GT10-000 TPS151GT12-000 TPS152GT8-000 TPS152GT10-000 TPS152GT12-000 TPS181GT8-000 TPS181GT10-000 TPS181GT12-000 TPS202GT8-000 TPS202GT10-000 TPS202GT12-000
Volts Watts
Thermostat Range On Off 80F 100F 120F 80F 100F 120F 80F 100F 120F 80F 100F 120F 80F 100F 120F 80F 100F 120F 100F 120F 140F 100F 120F 140F 100F 120F 140F 100F 120F 140F 100F 120F 140F 100F 120F 140F
Replaceable Parts T-Stat LSU-8 LSU-10 LSU-12 LSU-8 LSU-10 LSU-12 LSU-8 LSU-10 LSU-12 LSU-8 LSU-10 LSU-12 LSU-8 LSU-10 LSU-12 LSU-8 LSU-10 LSU-12 Element REPS051T8 REPS051T10 REPS051T12 REPS052T8 REPS052T10 REPS052T12 REPS101T8 REPS101T10 REPS101T12 REPS102T8 REPS102T10 REPS102T12 REPS151T8 REPS151T10 REPS151T12 REPS152T8 REPS152T10 REPS152T12 Tank TPS-T TPS-T TPS-T TPS-T TPS-T TPS-T TPS-T TPS-T TPS-T TPS-T TPS-T TPS-T TPS-T TPS-T TPS-T TPS-T TPS-T TPS-T Box CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 CPS-1 Power Cord 11P48UU 11P48UU 11P48UU 21P48UU 21P48UU 21P48UU 11P48UU 11P48UU 11P48UU 21P48UU 21P48UU 21P48UU 11P48UU 11P48UU 11P48UU 21P48UU 21P48UU 21P48UU Element O-ring TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR TPS-BOR
120 120 120 240 240 240 120 120 120 240 240 240 120 120 120 240 240 240 120 120 120 240 240 240
500 500 500 500 500 500 1000 1000 1000 1000 1000 1000 1500 1500 1500 1500 1500 1500
Element O-Ring
Replacement Element
Replacement Thermostat
1800 80F 100F LSU-8 REPS181T8 TPS-T CPS-1 12P48UU TPS-BOR 1800 100F 120F LSU-10 REPS181T10 TPS-T CPS-1 12P48UU TPS-BOR 1800 120F 140F LSU-12 REPS181T12 TPS-T CPS-1 12P48UU TPS-BOR 2000 80F 100F LSU-8 REPS202T8 TPS-T CPS-1 21P48UU TPS-BOR 2000 100F 120F LSU-10 REPS202T10 TPS-T CPS-1 21P48UU TPS-BOR 2000 120F 140F LSU-12 REPS202T12 TPS-T CPS-1 21P48UU TPS-BOR
Spokane, WA 99211-0245
Ambient Above -20 F 150 Cubic Inch or Less 350 Cubic Inch or Less 350 500 Cubic Inch or Less 500 700 Cubic Inch or Less
Ambient Below -20 F 150 Cubic Inch or Less 200 Cubic Inch or Less 200 300 Cubic Inch or Less 300 400 Cubic Inch or Less
Model Number TPS051GT12-001* TPS051GT12-A00 TPS052GT12-001* TPS052GT12-A00 TPS101GT12-001* TPS101GT12-A00 TPS102GT12-001* TPS102GT12-A00 TPS151GT12-001* TPS151GT12-A00 TPS152GT12-001* TPS152GT12-A00 TPS181GT12-001* TPS181GT12-A00 TPS202GT12-001* TPS202GT12-A00
Volts 120 120 240 240 120 120 240 240 120 120 240 240 120 120 240 240
Watts 500 500 500 500 1000 1000 1000 1000 1500 1500 1500 1500 1800 1800 2000 2000
Phase 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Amps 4.2 4.2 2.1 2.1 8.4 8.4 4.2 4.2 12.5 12.5 6.3 6.3 15 15 8.3 8.3
Thermostat Range On Off 100F 120F ADJUSTABLE 100F 120F ADJUSTABLE 100F 120F ADJUSTABLE 100F 120F ADJUSTABLE 100F 120F ADJUSTABLE 100F 120F ADJUSTABLE 100F 120F ADJUSTABLE 100F 120F ADJUSTABLE
6.7 7.9
4.25
Thermostat Well
4.6
Model Number TPS051GT12-001* TPS051GT12-A00 TPS052GT12-001* TPS052GT12-A00 TPS101GT12-001* TPS101GT12-A00 TPS102GT12-001* TPS102GT12-A00 TPS151GT12-001* TPS151GT12-A00 TPS152GT12-001* TPS152GT12-A00 TPS181GT12-001* TPS181GT12-A00 TPS202GT12-001* TPS202GT12-A00
Volts Watts 120 120 240 240 120 120 240 240 120 120 240 240 120 120 240 240 500 500 500 500
Replaceable Parts Sensing Unit LSU-10 RSU90-130 LSU-10 RSU90-130 Element REPS051T12 REPS051T12 REPS052T12 REPS052T12 REPS101T12 REPS101T12 REPS102T12 REPS102T12 REPS151T12 REPS151T12 REPS152T12 REPS152T12 Power Y-cord TPS-YC1 # TPS-YC2 # TPS-YC1 # TPS-YC2 # TPS-YC1 # TPS-YC2 # Thermostat Well TW2374-1 # TW2374-1 # TW2374-1 # TW2374-1 # TW2374-1 # TW2374-1 # TW2374-1 # TW2374-1 #
Replacement Parts
For TPS Model heaters w/in-line adjustable and remote thread-in fixed thermostat
Common Replacement Parts For ALL TPS Model Heaters: - Tank - Box - Element O-ring
See table on p. 6
1000 100F 120F LSU-10 1000 ADJUSTABLE RSU90-130 1000 100F 120F LSU-10 1000 ADJUSTABLE RSU90-130 1500 100F 120F LSU-10 1500 ADJUSTABLE RSU90-130 1500 100F 120F LSU-10 1500 ADJUSTABLE RSU90-130 1800 100F 120F LSU-10 1800 ADJUSTABLE RSU90-130 2000 100F 120F LSU-10 2000 ADJUSTABLE RSU90-130
# Call Factory
www.hotstart.com
Model Number without Thermostat CB115100-000 CB115800-000 CB115200-000 CB115700-000 CB115300-000 CB115400-000 CB120100-000 CB120800-000 CB120200-000 CB120300-000 CB120400-000 CB125100-000 CB125800-000 CB125200-000 CB125700-000 CB125300-000 CB125400-000 CL130100-100 CL130800-100 CL130200-100 CL130700-100 CL130300-100 CL130400-100 CL140800-100 CL140200-100 CL140700-100 CL140300-100 CL140400-100 CL150800-100 CL150200-100 CL150700-100 CL150300-100 CL150400-100
1350 1650 800 1000 Cubic Inch Cubic Inch or Less or Less
Model Number with Thermostat (see chart 1) CB1151XX-000 CB1158XX-000 CB1152XX-000 CB1157XX-000 CB1153XX-000 CB1154XX-000 CB1201XX-000 CB1208XX-000 CB1202XX-000 CB1203XX-000 CB1204XX-000 CB1251XX-000 CB1258XX-000 CB1252XX-000 CB1257XX-000 CB1253XX-000 CB1254XX-000 CL1301XX-100 CL1308XX-100 CL1302XX-100 CL1307XX-100 CL1303XX-100 CL1304XX-100 CL1408XX-100 CL1402XX-100 CL1407XX-100 CL1403XX-100 CL1404XX-100 CL1508XX-100 CL1502XX-100 CL1507XX-100 CL1503XX-100 CL1504XX-100
Volts Watts Phase Amps Fig.* No. 120 208 240 277 380 480 120 208 240 380 480 120 208 240 277 380 480 120 208 240 277 380 480 208 240 277 380 480 208 240 277 380 480 1500 1500 1500 1500 1500 1500 2000 2000 2000 2000 2000 2500 2500 2500 2500 2500 2500 3000 3000 3000 3000 3000 3000 4000 4000 4000 4000 4000 5000 5000 5000 5000 5000 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 12.5 7.2 6.3 5.4 3.9 3.1 16.7 9.6 8.3 5.3 4.2 20.8 12.0 10.4 9.0 6.6 5.2 25.0 14.4 12.5 10.8 7.9 6.3 19.2 16.7 14.4 10.5 8.3 24.0 20.8 18.1 13.2 10.4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
INSTALLATION TIPS If you require a 1 NPT female thread on the thermostat intake, a coupler is available. Also, for the use of 3/4 or 1 ID heater hose, hose barb adapters are available. See below. Part Number HB-1 Description 1 NPT to 1 hose barb adapter. Installs in 1 NPT female inlet or outlet of the heater. 1 NPT to 3/4 hose barb adapter. Installs in 1 NPT female inlet or outlet of the heater. 1 NPT x 1 NPT aluminum coupler. Installs on 1 NPT inlet to T-Stat and allows the addition of HB-1 or HB-3/4. Kit contains (2) HB-3/4 and (1) HB-C Kit contains (2) HB-1 and (1) HB-C
CHART 1 HEATERS WITH THERMOSTATS To specify temperature range of thermostat, insert numerical code from chart in place of the XX in model number. Example: Desired Temperature Range 100 - 120F Catalog Number: Model CB1151XX-000 Order as: Model CB115110-000 All heaters TEMPERATURE RANGE NUMERICAL over 277v CODE ON OFF and all 3 units must 60F 80F 06 use a control 80F 100F 08 box 100F 120F 10 120F 140F 12 See Control 140F 160F 14 Systems page 38 Adjustable 90 - 130F A3
HB-3/4
Model Number CB115100-000 CB115800-000 CB115200-000 CB115700-000 CB115300-000 CB115400-000 CB120100-000 CB120800-000 CB120200-000 CB120300-000 CB120400-000 CB125100-000 CB125800-000 CB125200-000 CB125700-000 CB125300-000 CB125400-000 CL130100-100 CL130800-100 CL130200-100 CL130700-100 CL130300-100 CL130400-100 CL140800-100 CL140200-100 CL140700-100 CL140300-100 CL140400-100 CL150800-100 CL150200-100 CL150700-100 CL150300-100 CL150400-100
Volts 120 208 240 277 380 480 120 208 240 380 480 120 208 240 277 380 480 120 208 240 277 380 480 208 240 277 380 480 208 240 277 380 480
Watts 1500 1500 1500 1500 1500 1500 2000 2000 2000 2000 2000 2500 2500 2500 2500 2500 2500 3000 3000 3000 3000 3000 3000 4000 4000 4000 4000 4000 5000 5000 5000 5000 5000
Element RECB1151 RECB1158 RECB1152 RECB1157 RECB1153 RECB1154 RECB1201 RECB1208 RECB1202 RECB1203 RECB1204 RECB1251 RECB1258 RECB1252 RECB1257 RECB1253 RECB1254 RECL1301-100 RECL1308-100 RECL1302-100 RECL1307-100 RECL1303-100 RECL1304-100 RECL1408-100 RECL1402-100 RECL1407-100 RECL1403-100 RECL1404-100 RECL1508-100 RECL1502-100 RECL1507-100 RECL1503-100 RECL1504-100
Tank RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL
Replaceable Parts Element Mounting Check Box O-ring Kit Valve RTBCB TMM-OR FK2 RV-M RTBCB TMM-OR FK2 RV-M RTBCB TMM-OR FK2 RV-M RTBCB TMM-OR FK2 RV-M RTBCB TMM-OR FK2 RV-M RTBCB TMM-OR FK2 RV-M RTBCB RTBCB RTBCB RTBCB RTBCB RTBCB RTBCB RTBCB RTBCB RTBCB RTBCB RTBCL-100 RTBCL-100 RTBCL-100 RTBCL-100 RTBCL-100 RTBCL-100 RTBCL-100 RTBCL-100 RTBCL-100 RTBCL-100 RTBCL-100 RTBCL-100 RTBCL-100 RTBCL-100 RTBCL-100 RTBCL-100 TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR FK2 FK2 FK2 FK2 FK2 FK2 FK2 FK2 FK2 FK2 FK2 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M
Replacement Parts
For tank-style heaters shown on page 8
Heaters with Thermostats Temperature Thermostat Range Replacement ON OFF 60F 80F 100F 120F 140F 80F 100F 120F 140F 160F RSU6 RSU8 RSU10 RSU12 RSU14 RSU90-130
Adjustable 90 - 130F
www.hotstart.com
Model Number with Thermostat (see chart 1) SB1151XX-000 SB1158XX-000 SB1152XX-000 SB1157XX-000
Fig.* No.
1 1 1 1
2 2 2 2
1 1 1
2 2 2
1 1 1 1
2 2 2 2
800 1000 500 600 Cubic Inch Cubic Inch or Less or Less
SB Model with power cord; no thermostat
1 1 1 1
4 4 4 4
1 1 1
4 4 4
*Figure Number refers to technical drawings of heaters located on page 14. All 208v, 277v and 3000w/120v models come with cord only - no plug.
INSTALLATION TIPS If you require a 1 NPT female thread on the thermostat intake, a coupler is available. Also, for the use of 3/4 or 1 ID heater hose, hose barb adapters are available. See below. Part Number HB-1 Description 1 NPT to 1 hose barb adapter. Installs in 1 NPT female inlet or outlet of the heater. 1 NPT to 3/4 hose barb adapter. Installs in 1 NPT female inlet or outlet of the heater. 1 NPT x 1 NPT aluminum coupler. Installs on 1 NPT inlet to T-Stat and allows the addition of HB-1 or HB-3/4. Kit contains (2) HB-3/4 and (1) HB-C Kit contains (2) HB-1 and (1) HB-C
CHART 1 HEATERS WITH THERMOSTATS To specify temperature range of thermostat, insert numerical code from chart in place of the XX in model number. Example: Desired Temperature Range 100 - 120F Catalog Number: Model SB1151XX-000 Order as: Model SB115110-000 TEMPERATURE RANGE NUMERICAL CODE ON OFF 60F 80F 100F 120F 140F 80F 100F 120F 140F 160F 06 08 10 12 14
HB-3/4
10
Replaceable Parts Volts Watts 120 208 240 277 1500 1500 1500 1500 Element Tank Box RESB1151 RESB1158 RESB1152 RESB1157 RTB RTB RTB RTB RTBSB RTBSB RTBSB RTBSB Power Cord RTHC1-16 RTHC-16 RTHC2-16 RTHC-16 Power Cord Element Mount Check Kit Valve w/T-stat plug* O-ring RHS1-16 RHS-16 RHS2-16 RHS-16 RHS1-14 RHS-16 RHS2-16 RHS1-14 RHS-16 RHS2-16 RHS-16 N/A RHS-16 RHS2-16 RHS-16 RHS-14 RHS2-14 RHS-16 TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TMM-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR FK2 FK2 FK2 FK2 FK2 FK2 FK2 FK2 FK2 FK2 FK2 FK6 FK6 FK6 FK6 FK6 FK6 FK6 RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M
Replacement Parts
For tank-style heaters shown on page 10
SB120100-000 120 SB120800-000 208 SB120200-000 240 SB122100-000 SB125800-000 SB125200-000 SB125700-000 SL130100-000 SL130800-000 SL130200-000 SL130700-000 120 208 240 277 120 208 240 277
2000 RESB1201 RTB RTBSB RTHC1-14 2000 RESB1208 RTB RTBSB RTHC-16 2000 RESB1202 RTB RTBSB RTHC2-16 2250 2500 2500 2500 3000 3000 3000 3000 RESB1221 RECB1258 RECB1252 RECB1257 RESL1301 RESL1308 RESL1302 RESL1307 RTB RTB RTB RTB RTL RTL RTL RTL RTBSB RTBSB RTBSB RTBSB RTHC1-14 RTHC-16 RTHC2-16 RTHC-16
*Order this replacement cord if original heater is configured with a thermostat assembly.
Replacement Cord
Mounting Kit Replacement Thermostat Replacement Tank Replacement Element Element O-Ring Replacement Box Check Valve
Replacement Cord
Mounting Kit Replacement Tank Replacement Element Element O-Ring Replacement Box
Heaters with Thermostats Temperature Thermostat Range Replacement ON OFF 60F 80F 100F 120F 140F 80F 100F 120F 140F 160F RSU6 RSU8 RSU10 RSU12 RSU14 RSU90-130
Adjustable 90 - 130F
www.hotstart.com
11
Model Number without Thermostat WL315800-000 WL315200-000 WL315400-000 WL320800-000 WL320200-000 WL320300-000 WL320400-000 WL320500-000 WL325800-000 WL325200-000 WL325300-000 WL325400-000 WL325500-000 WL330800-000 WL330200-000 WL330300-000 WL330400-000 WL330500-000 WL340800-000 WL340200-000 WL340300-000 WL340400-000 WL340500-000 WL350800-000 WL350200-000 WL350300-000 WL350400-000 WL350500-000
Model Number with Thermostat (see chart 1) WL3158XX-000 WL3152XX-000 WL3154XX-000 WL3208XX-000 WL3202XX-000 WL3203XX-000 WL3204XX-000 WL3205XX-000 WL3258XX-000 WL3252XX-000 WL3253XX-000 WL3254XX-000 WL3255XX-000 WL3308XX-000 WL3302XX-000 WL3303XX-000 WL3304XX-000 WL3305XX-000 WL3408XX-000 WL3402XX-000 WL3403XX-000 WL3404XX-000 WL3405XX-000 WL3508XX-000 WL3502XX-000 WL3503XX-000 WL3504XX-000 WL3505XX-000
Volts
Watts
208 240 480 208 240 380 480 575 208 240 380 480 575 208 240 380 480 575 208 240 380 480 575 208 240 380 480 575
1500 1500 1500 2000 2000 2000 2000 2000 2500 2500 2500 2500 2500 3000 3000 3000 3000 3000 4000 4000 4000 4000 4000 5000 5000 5000 5000 5000
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
4.2 3.6 1.8 5.6 4.8 3.0 2.4 2.0 6.9 6.0 3.8 3.0 2.5 8.3 7.2 4.6 3.6 3.0 11.1 9.6 6.1 4.8 4.0 13.9 12.0 7.6 6.0 5.0
5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5
1350 1650 800 1000 Cubic Cubic Inch Inch or Less or Less
INSTALLATION TIPS If you require a 1 NPT female thread on the thermostat intake, a coupler is available. Also, for the use of 3/4 or 1 ID heater hose, hose barb adapters are available. See below. Part Number HB-1 Description 1 NPT to 1 hose barb adapter. Installs in 1 NPT female inlet or outlet of the heater. 1 NPT to 3/4 hose barb adapter. Installs in 1 NPT female inlet or outlet of the heater. 1 NPT x 1 NPT aluminum coupler. Installs on 1 NPT inlet to T-Stat and allows the addition of HB-1 or HB-3/4. Kit contains (2) HB-3/4 and (1) HB-C Kit contains (2) HB-1 and (1) HB-C
CHART 1 HEATERS WITH THERMOSTATS To specify temperature range of thermostat, insert numerical code from chart in place of the XX in model number. Example: Desired Temperature Range 100 - 120F Catalog Number: Model WL3152XX-000 Order as: Model WL315210-000 All heaters TEMPERATURE RANGE NUMERICAL over 277v CODE ON OFF and all 3 units must 60F 80F 06 use a control 80F 100F 08 box 100F 120F 10 120F 140F 12 See Control 140F 160F 14 Systems page 38 Adjustable 90 - 130F A3
HB-3/4
12
Replaceable Parts Model Number WL315800-000 WL315200-000 WL315400-000 WL320800-000 WL320200-000 WL320300-000 WL320400-000 WL320500-000 WL325800-000 WL325200-000 WL325300-000 WL325400-000 WL325500-000 WL330800-000 WL330200-000 WL330300-000 WL330400-000 WL330500-000 WL340800-000 WL340200-000 WL340300-000 WL340400-000 WL340500-000 WL350800-000 WL350200-000 WL350300-000 WL350400-000 WL350500-000 Volts 208 240 480 208 240 380 480 575 208 240 380 480 575 208 240 380 480 575 208 240 380 480 575 208 240 380 480 575 Watts 1500 1500 1500 2000 2000 2000 2000 2000 2500 2500 2500 2500 2500 3000 3000 3000 3000 3000 4000 4000 4000 4000 4000 5000 5000 5000 5000 5000 Element E01583W-15NT-00 E01523W-15NT-00 E01543W-15NT-00 E02083W-25NT-00 E02023W-25NT-00 E02033W-25NT-00 E02043W-25NT-00 E02053W-25NT-00 E02583W-30NT-00 E02523W-30NT-00 E02533W-30NT-00 E02543W-30NT-00 E02553W-30NT-00 E03083W-30NT-00 E03023W-30NT-00 E03033W-30NT-00 E03043W-30NT-00 E03053W-30NT-00 E04083W-50NT-00 E04023W-50NT-00 E04033W-50NT-00 E04043W-50NT-00 E04053W-50NT-00 E05083W-50NT-00 E05023W-50NT-00 E05033W-50NT-00 E05043W-50NT-00 E05053W-50NT-00 Tank RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL Element O-ring TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR Mounting Kit FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 Check Valve RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M
Replacement Parts
For tank-style heaters shown on page 12
Replacement Thermostat
Element O-Ring
Check Valve
Heaters with Thermostats Temperature Thermostat Range Replacement ON OFF 60F 80F 100F 120F 140F 80F 100F 120F 140F 160F RSU6 RSU8 RSU10 RSU12 RSU14 RSU90-130
Adjustable 90 - 130F
www.hotstart.com
13
FIGURE 1
3.85
4.06
5.75
3.85
5.26
FIGURE 2
4.00
4.90
4.06
8.43
5.75
4.06 4.39
3.75 4.35
FIGURE 3
5.25 4.25
ADJUSTABLE
2.5
6.4 7.2
FIGURE 4
FIGURE 5
5.25 4.21
18.0 ADJUSTABLE
6.2 5.0
14
Large NEMA 4 enclosure with 1/2 and 3/4 knockouts. Rubber insulating sleeve around tank. Internal adjustable thermostat. Adjustable setpoints from 70F - 210F. Incoloy sheath elements. Four wattage/voltage options. Three corresponding to Caterpillar part numbers. Vertical mount only. For Original Equipment Replacement: Two 5 stainless steel worm-drive clamps are included to mount heater to existing bracket. For New Installations: U-bolt mounting brackets are available. Order kit part number: FK9.
www.hotstart.com
15
UL-C/US listed (60Hz models) and CE compliant (50Hz models). 90-130F/32-55C adjustable thermostat.
Small, compact design for easy installation. Meets requirements for installation on any UL 2200 listed generator
Part Number CSM10301-000 CSM10308-000 CSM1030C-000 CSM10302-000 CSM10608-000 CSM1060C-000 CSM10602-000 CSM10604-000 CSM30603-000 CSM30604-000 CSM10908-000 CSM1090C-000 CSM10902-000 CSM10904-000 CSM30903-000 CSM30904-000 CSM11202-000 CSM11204-000 CSM31203-000 CSM31204-000
Wattage 3000 3000 3000 3000 6000 6000 6000 6000 6000 6000 9000 9000 9000 9000 9000 9000 12000 12000 12000 12000
Voltage 120 208 220 240 208 220 240 480 380 480 208 220 240 480 380 480 240 480 380 480
Phase 1 1 1 1 1 1 1 1 3 3 1 1 1 1 3 3 1 1 3 3
Hz 60 60 50 60 60 50 60 60 50 60 60 50 60 60 50 60 60 60 50 60
Amps 27.0 16.4 15.6 14.5 30.8 29.3 27.0 14.5 11.1 9.2 45.3 42.9 39.5 20.8 15.7 12.8 52.0 27.0 20.3 16.5
15-30
The CSM operates automatically by supplying a 24 Volt DC signal to the provided contacts. Field testing has shown substantial energy savings in comparison to traditional thermosiphon heating methods. 16
HOTSTART Engine Heating P.O. Box 11245 Spokane Valley, WA 99211-0245
1 240v or Less
System Drawings
CSM Dimensions
1 or 3 Over 240v
Shipping Weight: 54lbs. (24.5kg) * For CE compliant models, overall depth measures 10.8 (274mm)
www.hotstart.com
17
18
Section 2
Industrial Tank Style Coolant Heaters Hazardous Location
19
Model Number without Thermostat EE115100-000 EE115800-000 EE115200-000 EE115700-000 EE115300-000 EE115400-000 EE115500-000 EE120100-000 EE120800-000 EE120200-000 EE120300-000 EE120400-000 EE120500-000 EE125100-000 EE125800-000 EE125200-000 EE125700-000 EE125300-000 EE125400-000 EE125500-000 EE130100-000 EE130800-000 EE130200-000 EE130700-000 EE130300-000 EE130400-000 EE130500-000 EE140800-000 EE140200-000 EE140700-000 EE140300-000 EE140400-000 EE140500-000 EE150800-000 EE150200-000 EE150700-000 EE150300-000 EE150400-000 EE150500-000
Fig.* No. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Model Number with Thermostat (see chart 1) EE1151XX-000 EE1158XX-000 EE1152XX-000 EE1157XX-000 EE1153XX-000 EE1154XX-000 EE1155XX-000 EE1201XX-000 EE1208XX-000 EE1202XX-000 EE1203XX-000 EE1204XX-000 EE1205XX-000 EE1251XX-000 EE1258XX-000 EE1252XX-000 EE1257XX-000 EE1253XX-000 EE1254XX-000 EE1255XX-000 EE1301XX-000 EE1308XX-000 EE1302XX-000 EE1307XX-000 EE1303XX-000 EE1304XX-000 EE1305XX-000 EE1408XX-000 EE1402XX-000 EE1407XX-000 EE1403XX-000 EE1404XX-000 EE1405XX-000 EE1508XX-000 EE1502XX-000 EE1507XX-000 EE1503XX-000 EE1504XX-000 EE1505XX-000
Fig.* Volt Watt Amp No. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 120 208 240 277 380 480 575 120 208 240 380 480 575 120 208 240 277 380 480 575 120 208 240 277 380 480 575 208 240 277 380 480 575 208 240 277 380 480 575 1500 1500 1500 1500 1500 1500 1500 2000 2000 2000 2000 2000 2000 2500 2500 2500 2500 2500 2500 2500 3000 3000 3000 3000 3000 3000 3000 4000 4000 4000 4000 4000 4000 5000 5000 5000 5000 5000 5000 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 12.5 7.2 6.3 5.4 3.9 3.1 2.6 16.7 9.6 8.3 5.3 4.2 3.5 20.8 12.0 10.4 9.2 6.6 5.2 4.3 25.0 14.4 12.5 10.8 7.9 6.3 5.2 19.2 16.7 14.4 10.5 8.3 7.0 24.0 20.8 18.1 13.2 10.4 8.7
INSTALLATION TIPS For the use of 3/4 or 1 ID heater hose, hose barb adapters are available. See below. Part Number Description 1 NPT to 1 hose barb adapter. Installs in 1 NPT female inlet or outlet of the heater. 1 NPT to 3/4 hose barb adapter. Installs in 1 NPT female inlet or outlet of the heater.
CHART 1 HEATERS WITH THERMOSTATS To specify temperature range of thermostat, insert numerical code from chart in place of the XX in model number. Example: Desired Temperature Range 100 - 120F Catalog Number: Model EE1151XX-000 Order as: Model EE115110-000 All heaters TEMPERATURE RANGE NUMERICAL over 277v CODE and all 3 ON OFF units must 60F 80F 06 use a control 80F 100F 08 box 100F 120F 10 See Control 120F 140F 12 Systems 140F 160F 14 page 38
P.O. Box 11245 Spokane Valley, WA 99211-0245
HB-1
HB-3/4
20
Model Number EE115100-000 EE115800-000 EE115200-000 EE115700-000 EE115300-000 EE115400-000 EE115500-000 EE120100-000 EE120800-000 EE120200-000 EE120300-000 EE120400-000 EE120500-000 EE125100-000 EE125800-000 EE125200-000 EE125700-000 EE125300-000 EE125400-000 EE125500-000 EE130100-000 EE130800-000 EE130200-000 EE130700-000 EE130300-000 EE130400-000 EE130500-000 EE140800-000 EE140200-000 EE140700-000 EE140300-000 EE140400-000 EE140500-000 EE150800-000 EE150200-000 EE150700-000 EE150300-000 EE150400-000 EE150500-000
Replaceable Parts Volts Watts 120 208 240 277 380 480 575 120 208 240 380 480 575 120 208 240 277 380 480 575 120 208 240 277 380 480 575 208 240 277 380 480 575 208 240 277 380 480 575 Element MI Cable Tank Flange Flange Mount Check O-ring Kit Valve RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M
1500 REEE1151 PRP104202-024 1500 REEE1158 PRP104202-024 1500 REEE1152 PRP104202-024 1500 REEE1157 PRP104202-024 1500 E01531E-50NA-00 PRP104202-024 1500 E01541E-50NA-00 PRP104202-024 1500 E01551E-50NA-00 PRP104202-024 2000 REEE1201 PRP104202-024 2000 REEE1208 PRP104202-024 2000 REEE1202 PRP104202-024 2000 E02031E-50NA-00 PRP104202-024 2000 E02041E-50NA-00 PRP104202-024 2000 E02051E-50NA-00 PRP104202-024 2500 REEE1251 PRP104202-024 2500 REEE1258 PRP104202-024 2500 REEE1252 PRP104202-024 2500 REEE1257 PRP104202-024 2500 E02531E-C0NA-00 PRP104202-024 2500 E02541E-C0NA-00 PRP104202-024 2500 E02551E-C0NA-00 PRP104202-024 3000 REEE1301 PRP104202-024 3000 REEE1308 PRP104202-024 3000 REEE1302 PRP104202-024 3000 REEE1307 PRP104202-024 3000 E03031E-50NA-00 PRP104202-024 3000 E03041E-50NA-00 PRP104202-024 3000 E03051E-50NA-00 PRP104202-024 4000 REEE1408 PRP104202-024 4000 REEE1402 PRP104202-024 4000 REEE1407 PRP104202-024 4000 E04031E-50NA-00 PRP104202-024 4000 E04041E-50NA-00 PRP104202-024 4000 E04051E-50NA-00 PRP104202-024 5000 5000 5000 5000 5000 5000 E05081E-50NA-00 E05021E-50NA-00 E05071E-C0NA-00 E05031E-C0NA-00 E05041E-C0NA-00 E05051E-C0NA-00 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024
Replacement Parts
For tank-style heaters shown on page 20
Replacement Element
Check Valve
Heaters with Thermostats Temperature Thermostat Range Replacement ON OFF 60F 80F 100F 120F 140F 80F 100F 120F 140F 160F RSU6 RSU8 RSU10 RSU12 RSU14
www.hotstart.com
21
Model Number Fig.* Model Number Fig.* without No. with Thermostat No. Thermostat (see chart 1) EE315800-000 EE315200-000 EE315400-000 EE320800-000 EE320200-000 EE320300-000 EE320400-000 EE320500-000 EE325800-000 EE325200-000 EE325300-000 EE325400-000 EE325500-000 EE330800-000 EE330200-000 EE330300-000 EE330400-000 EE330500-000 EE340800-000 EE340200-000 EE340300-000 EE340400-000 EE340500-000 EE350800-000 EE350200-000 EE350300-000 EE350400-000 EE350500-000 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 EE3158XX-000 EE3152XX-000 EE3154XX-000 EE3208XX-000 EE3202XX-000 EE3203XX-000 EE3204XX-000 EE3205XX-000 EE3258XX-000 EE3252XX-000 EE3253XX-000 EE3254XX-000 EE3255XX-000 EE3308XX-000 EE3302XX-000 EE3303XX-000 EE3304XX-000 EE3305XX-000 EE3408XX-000 EE3402XX-000 EE3403XX-000 EE3404XX-000 EE3405XX-000 EE3508XX-000 EE3502XX-000 EE3503XX-000 EE3504XX-000 EE3505XX-000 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Volt Watts
Amp
208 240 480 208 240 380 480 575 208 240 380 480 575 208 240 380 480 575 208 240 380 480 575 208 240 380 480 575
1500 1500 1500 2000 2000 2000 2000 2000 2500 2500 2500 2500 2500 3000 3000 3000 3000 3000 4000 4000 4000 4000 4000 5000 5000 5000 5000 5000
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
4.2 3.6 1.8 5.6 4.8 3.0 2.4 2.0 6.9 6.0 3.8 3.0 2.5 8.3 7.2 4.6 3.6 3.0 11.1 9.6 6.1 4.8 4.0 13.9 12.0 7.6 6.0 5.0
INSTALLATION TIPS For the use of 3/4 or 1 ID heater hose, hose barb adapters are available. See below. Part Number Description 1 NPT to 1 hose barb adapter. Installs in 1 NPT female inlet or outlet of the heater. 1 NPT to 3/4 hose barb adapter. Installs in 1 NPT female inlet or outlet of the heater.
CHART 1 HEATERS WITH THERMOSTATS To specify temperature range of thermostat, insert numerical code from chart in place of the XX in model number. Example: Desired Temperature Range 100 - 120F Catalog Number: Model EE3152XX-000 Order as: Model EE315210-000 All heaters TEMPERATURE RANGE NUMERICAL over 277v CODE and all 3 ON OFF units must 60F 80F 06 use a control 80F 100F 08 box 100F 120F 10 See Control 120F 140F 12 Systems 140F 160F 14 page 38
P.O. Box 11245 Spokane Valley, WA 99211-0245
HB-1
HB-3/4
22
Model Number EE315800-000 EE315200-000 EE315400-000 EE320800-000 EE320200-000 EE320300-000 EE320400-000 EE320500-000 EE325800-000 EE325200-000 EE325300-000 EE325400-000 EE325500-000 EE330800-000 EE330200-000 EE330300-000 EE330400-000 EE330500-000 EE340800-000 EE340200-000 EE340300-000 EE340400-000 EE340500-000 EE350800-000 EE350200-000 EE350300-000 EE350400-000 EE350500-000
Replaceable Parts Volts Watts 208 240 480 208 240 380 480 575 208 240 380 480 575 208 240 380 480 575 208 240 380 480 575 208 240 380 480 575 Element MI Cable Tank Flange Flange Mount Check O-ring Kit Valve RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RTL RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L RF-L TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR TML-OR FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 FK6 RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M RV-M
1500 E01583E-15NA-00 PRP104202-024 1500 E01523E-15NA-00 PRP104202-024 1500 E01543E-15NA-00 PRP104202-024 2000 2000 2000 2000 2000 2500 2500 2500 2500 2500 3000 3000 3000 3000 3000 4000 4000 4000 4000 4000 5000 5000 5000 5000 5000 E02083E-25NA-00 E02023E-25NA-00 E02033E-25NA-00 E02043E-25NA-00 E02053E-25NA-00 E02583E-30NA-00 E02523E-30NA-00 E02533E-30NA-00 E02543E-30NA-00 E02553E-30NA-00 E03083E-30NA-00 E03023E-30NA-00 E03033E-30NA-00 E03043E-30NA-00 E03053E-30NA-00 E04083E-50NA-00 E04023E-50NA-00 E04033E-50NA-00 E04043E-50NA-00 E04053E-50NA-00 E05083E-50NA-00 E05023E-50NA-00 E05033E-50NA-00 E05043E-50NA-00 E05053E-50NA-00 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024 PRP104202-024
Replacement Parts
For tank-style heaters shown on page 22
Heaters with Thermostats Temperature Thermostat Range Replacement ON OFF 60F 80F 100F 120F 140F 80F 100F 120F 140F 160F RSU6 RSU8 RSU10 RSU12 RSU14
www.hotstart.com
23
ADJUSTABLE
2.5 5.0
5.0
5.3
FIGURE 2
1" NPT outlet 24.77 ADJUSTABLE
2.09 6.3
6.75
5.32
24
Section 3
Industrial Oil Heaters Industrial Immersion Heaters Thread-in style and threadless V-clamp style DC Oil Heaters Temperature Controls
25
Oil Heaters
Oil Capacity Weathertight Heater Only Weathertight With Thermostat (see chart p. 27) Class 1, Group D Hazardous Locations Heater Only Volts Watts Amps Watts Per Square Inch
5 Gallons to 15 Gallons
15 Gallons to 30 Gallons
NOTES: Weathertight heaters are standard with a 4 ft. oil and heat resistant power cord - no plug. Class 1, Group D heaters are standard with 18 of lead wire for connection to the power leads in an approved splice box. For Class 1, Group D thermostats, see page 32.
26
WEATHERTIGHT
heater only
CLASS 1, GROUP D
for hazardous locations heater only
9.20 6.7 5.25 Probe Depth 1" Dia. 2.40 1.97 Reducer 3/4" NPT x 1/2" NPT 5.25 Probe Depth
1" NPT
1" NPT
3/4" NPT
3/4" NPT
7.75 Reducer 3/4" NPT x 1/2" NPT 6.5 4.00 Probe Depth .50 Dia. 1/2" NPT 1-14 UNS 1 3/8 Std. Hex 1/2" NPT 2.40 1.97 4.00 Probe Depth
Heaters with Y-type harness and thermostat (see page 32 for drawings with dimensions)
Use a thermostat with all lube oil heaters to protect the oil from overheating if the heater is energized while the engine is hot or running. Lube oil heaters must always be installed in the sump with the entire heater submerged below the oil level at all times. OIL HEATERS WITH THERMOSTATS
To specify temperature range of thermostat, insert numerical code from chart in place of the XX in model number. Example: Desired Temperature Range 100 - 120 Catalog Number: Model OW2121XX-000 Order as: Model OW212110-000
Thermostat
NUMERICAL CODE 06 08 10 12
TEMPERATURE RANGE On 60F 80F 100F 120F Off 80F 100F 120F 140F
SWITCH CAPACITY
THREAD SIZE
120 Volt and 240 Volt are complete with a 3-prong plug. HOTSTART Assembled Lube Oil Heaters eliminate the need for splice boxes or field wiring of the thermostat and heater. Always mount the thermostat above and to one side of the heater for the most efficient control.
Customer Support: (509) 536-8660 Toll-Free FAX: (800) 224-5550
120V - 15 Amps 208V - 10 Amps 240V - 10 Amps 277V - 10 Amps 1/2 N.P.T.
www.hotstart.com
27
2 Screw Plug
For: Lube Oils, Hydraulics and Diesel Fuels With Fixed-Setting, Built-In Thermostat (Pg. 29) or Adjustable Thermostat (Pg. 31) Weather Tight NEMA 4 Enclosure
Models for larger capacities than shown are available. Call factory.
HIGH LIMIT THERMOSTAT CONTROL SETTING Volts On 80 F / Off 100 F On 100 F / Off 120 F Watts Amps
45 to 60 Gallons
45 to 60 Gallons
60 to 90 Gallons
Class I, Group D heaters with thermostat for hazardous locations also available. Substitute the letter W in part number with the letter E to specify Class I, Group D heaters. Industrial Immersion Heaters are also available for coolants and other process heating. Call factory.
28
HOTSTART immersion heaters are complete with a fixed-setting, built-in thermostat (shown below). All models are also available with an adjustable thermostat (pg. 31). Ideal for heating hydraulic reservoirs on construction equipment and the sumps of large industrial engines.
12" OR 18" DIM 1.0 3.25
3.60
2" NPT
1.3
4.3
4.4
ELECTRICAL RATING 15 Amps 10 Amps 10 Amps at at at 120 VAC 240 VAC 277 VAC
Thermostat Sensor
NOTES:
On applications where level of fluid is subject to change, a liquid level switch mounted a minimum of 3 to 4 inches above element is recommended. Liquid level switch is not included with heater. All 380 Volt and 480 Volt heaters must be used in conjunction with contactor and control transformer. All three phase heaters must be used with a contactor. See pages 37 & 38.
Heating Element
Fuse
Fuse
Temp. Control
Heating Element
www.hotstart.com
Models for larger capacities than shown are available. Call factory.
HIGH LIMIT THERMOSTAT CONTROL SETTING Volts On 80 F / Off 100 F On 100 F / Off 120 F Watts Amps
45 to 60 Gallons
45 to 60 Gallons
Class I, Group D heaters with thermostat for hazardous locations also available. Substitute the letter W in part number with the letter E to specify Class I, Group D heaters. Industrial Immersion Heaters are also available for coolants and other process heating. Call factory.
30
12or 18 DIM
3.72
V-Clamp
Weldable Adapter
O-ring
3.60
NOTE: Replacement elements supplied with O Ring only. For new installations, order kit - P/N VC-SK. Kit Includes: 1 steel weldable adapter 1 worm-drive V-Clamp 1 O Ring
ELECTRICAL RATING 30 Amps 30 Amps 30 Amps 20 Amps at at at at 125 VAC 240 VAC 277 VAC 480 VAC
NOTES:
On applications where level of fluid is subject to change, a liquid level switch mounted a minimum of 3 to 4 inches above element is recommended. Liquid level switch is not included with heater. All 380 Volt and 480 Volt heaters must be used in conjunction with contactor and control transformer. All three phase heaters must be used with a contactor. See pages 37 & 38. Higher or lower temperature ranges are available. Consult HOTSTART.
Cover
Fasteners, Cover
Ground Screw
Ground Lug
www.hotstart.com
31
DC Oil Heaters
12 and 24 volt
12 VOLT/24 VOLT DC CONTROL BOXES 25 Amps Maximum 12V 24V JBMC330DC-12V JBMC330DC-24V
HOTSTART Model Numbers Oil 3/4 N.P.T. With a Capacity Volts Watts 1/2 N.P.T. With a 4 7/8 Probe 4 Probe Length Length 2 Quarts or Less 2 to 6 Quarts 1 to 5 Gallons 5 to 15 Gallons 15 to 30 Gallons 12 24 24 12 24 12 24 24 75 75 125 150 150 300 300 500 OW207900-012 OW207900-024 OW212900-024 OW407900-012 OW407900-024 OW415900-012 OW415900-024 OW430900-024 1 N.P.T. With a 5 3/8 Probe Length OW615900-012 OW615900-024 OW630900-012 OW630900-024 OW650900-024 Amps Watts Per Square Inch 1/2 are all 14.7 WSI 3/4 are all 7.3 WSI 24.6 WSI 3/4 are all 14.6 WSI 1 are all 10.7 WSI 3/4 are all 29.3 WSI 1 are all 21.4 WSI 35.7 WSI
When used with a thermostat control, all DC oil heaters must use a DC relay
Please see page 27 for photos and technical drawings of OW and OE style oil heaters.
12 or 24 VDC
12 Volt and 24 Volt DC oil heaters can be powered directly from the battery, but will drain the battery very rapidly unless charged by an alternator or generator.
Magnetic Contactors
C1 C1 COIL
C1
DIT
Oil Heater
NOTE: Heater amperage as shown in the table above will determine the life of the battery (Amps x Hours = Amp hours). 100 Amp-hour Example: A 12.5 Amp heater will completely = 8 Hours drain a 100 Amp-hour battery in 8 hours. 12.5 Amp
Temperature Controls
Weathertight Weathertight models are furnished with a 3 ft. 16/3 HPN power cord. Class I, Group D model is furnished with 18 of lead wire for connection to the power leads in an approved splice box.
Lube oil temperature controls hold lube oil at the desired temperature. If the heater is energized while the engine is hot or running, Kim Hotstart recommends using thermostats with all lube oil heaters to protect the oil from overheating. The sensing unit can be changed without draining the sump.
Temp. Range On Off 60F 80F 100F 120F 80F 100F 120F 140F
Thread Size 1/2 N.P.T. 1/2 N.P.T. 1/2 N.P.T. 1/2 N.P.T.
Switch Capacity 120v - 15 amps 208v - 10 amps 240v - 10 amps 277v - 10 amps 12v DC Pilot 24v DC Duty Only
5.50 3.375 1.625 Probe Depth .600 3' 16-3 HPN Cord 1.75 1.625 Probe Depth 3.25 .600
.5 NPT
.5 Inch NPT
32
Section 4
Thermostat Controls Pressure Switch Magnetic Contactors Junction Boxes Complete Control Systems for manual and automatic start engines
33
Temperature Controls
Weathertight NOTE: When using a thermostat above 277 volt or on 3 phase applications, select the proper control box with transformer and contactor as shown on pages 37 or 38.
CONDUIT TYPE ENCLOSURE Temp. Setting On Off Maximum Capacity Ratings 120/240Volt 277 Volt 25 amps 25 amps 25 amps 25 amps 25 amps 22 amps 22 amps 22 amps 22 amps 22 amps
Part Number
4.71
3.62
TFTC6-1NPT 60F 80F TFTC8-1NPT 80F 100F TFTC10-1NPT 100F 120F TFTC12-1NPT 120F 140F TFTC14-1NPT 140F 160F
Part Number
Maximum Capacity Ratings 120/240Volt 277 Volt 25 amps 25 amps 25 amps 25 amps 25 amps 22 amps 22 amps 22 amps 22 amps 22 amps
Off
3.62
TFTC6-1HB 60F 80F TFTC8-1HB 80F 100F TFTC10-1HB 100F 120F TFTC12-1HB 120F 140F TFTC14-1HB 140F 160F
CONDUIT TYPE ENCLOSURE Temp. Setting On Off Maximum Capacity Ratings 120/240Volt 277 Volt 25 amps 25 amps 25 amps 25 amps 25 amps 22 amps 22 amps 22 amps 22 amps 22 amps
Part Number
TFTC6-3HB 60F 80F TFTC8-3HB 80F 100F TFTC10-3HB 100F 120F TFTC12-3HB 120F 140F TFTC14-3HB 140F 160F
3.62
CLASS 1, GROUP D
1/2" NPT Conduit Opening 3.0 5.0
CONDUIT TYPE ENCLOSURE Temp. Setting On Off 80F 100F 120F 140F 160F Maximum Capacity Ratings 120/240Volt 277 Volt 25 amps 25 amps 25 amps 25 amps 25 amps 22 amps 22 amps 22 amps 22 amps 22 amps
Part Number
34
1NPT x 1NPT
CORD TYPE ENCLOSURE
1"NPT
1"NPT 3.30
Temperature Controls
Weathertight NOTE: When using a thermostat above 277 volt or on 3 phase applications, select the proper control box with transformer and contactor as shown on pages 37 or 38.
Part Number
4.71
Maximum Capacity Ratings 120/240Volt 277 Volt 25 amps 25 amps 25 amps 25 amps 25 amps 22 amps 22 amps 22 amps 22 amps 22 amps
2.56
TFT6-1NPT 60F 80F TFT8-1NPT 80F 100F TFT10-1NPT 100F 120F TFT12-1NPT 120F 140F TFT14-1NPT 140F 160F
14-3 HPN (4 FT.)
CORD TYPE ENCLOSURE Temp. Setting On Off Maximum Capacity Ratings 120/240Volt 277 Volt 25 amps 25 amps 25 amps 25 amps 25 amps 22 amps 22 amps 22 amps 22 amps 22 amps
Part Number
4.96
2.63
TFT6-1HB 60F 80F TFT8-1HB 80F 100F TFT10-1HB 100F 120F TFT12-1HB 120F 140F TFT14-1HB 140F 160F
Part Number
4.96
2.63
TFT6-3HB 60F 80F TFT8-3HB 80F 100F TFT10-3HB 100F 120F TFT12-3HB 120F 140F TFT14-3HB 140F 160F
REMOTE-MOUNT ADJUSTABLE
With 60 Capillary Probe
3.36
Part Number
Adjustable Range 65F to 250 (Open or Off Setting) Differential 7F (Close or On Setting) Maximum Capacity Ratings 120/240 Volt 25 Amps 277 Volt 22 Amps
5.06
5 155 185 21 5 250
6.38
LO
.078 Dia.
60
95
1.03
12
.5 inch NPT
www.hotstart.com
35
Temperature Controls
Adjustable Thermostat Reduce engine heater cycle time in both warm and cold ambient temperatures.
HOTSTART offers an adjustable thermostat as an option on weathertight engine preheaters and as a stand-alone unit. Control your optimum desired temperature with Kim Hotstarts adjustable thermostat. Adjustable from 90F to 130F. Stock one thermostat to fit all needs. 5/8 hose barb or 1 NPT thread connections allow for easy in-line installations on a variety of heating units. Weather resistant enclosure. Rated up to 480 volts.
Cord Type
14-3 HPN (4 FT.) 2.57
5/8" Hosebarb
Cord Type Model Number TFTA-1NPT TFTA-5/8HB Electrical Rating 120/240 Volt 25 Amps 277 Volt 22Amps 480 Volt 12.5 Amps
Conduit Type
6.43 3.66
1" NPT
1" NPT
36
Control Components
PS252
Magnetic Contactors
Kim Hotstart Model Number 30 AMPS Coil Voltage 60 AMPS Kim Hotstart Model Number Coil Voltage
MC330
DRY LOCATIONS MC330L MC330 WET LOCATIONS JBW11-000 JBW12-000 120V 240V 120V 240V
DRY LOCATIONS MC360L MC360 WET LOCATIONS JBW11-060 JBW12-060 120V 240V 120V 240V
3 POLE
3 POLE
Junction Boxes
Use to simplify wiring on equipment when a variety of heaters and controls are required. All models have ten, 25 Amp terminal blocks. Part Number PDB-000 Number of Openings 8* * Box comes assembled with 4 strain relief connectors. For additional connectors, order part# PDB-1.
PDB-000
PDB-1
www.hotstart.com
37
Manual Control Systems JBW11-000 JBW18-000 JBW12-000 JBW13-000 JBW14-000 JBW15-000 JBW11-060 JBW14-060
Box Size A A A B B B A B
Automatic Control Systems With 24 Volt Relay JBW11-100 JBW18-100 JBW12-100 JBW13-100 JBW14-100 JBW15-100 JBW11-160 JBW14-160 Box Size B B B B B B B B With Pressure Switch JBW11-200 JBW18-200 JBW12-200 JBW13-200 JBW14-200 JBW15-200 JBW11-260 JBW14-260 Box Size C C C C C C C C Volts 120V 208V 240V 380V 480V 575V 120V 480V
30 Amps Maximum
60 Amps Maximum
All control boxes are available for Class 1 Group D hazardous locations, change prefix JBW to JBE Consult factory for price . and availability. Box Size Code: A 6 x 6 x 4, B 8 x 8 x 4, C 10 x 8 x 4, D 12 x 10 x 5 38
HOTSTART Engine Heating P.O. Box 11245 Spokane Valley, WA 99211-0245
All HOTSTART heaters with thermostats, designed to operate on 3-phase current (at any voltage), require the use of a control system with a 3-pole contactor. All Kim Hotstart heaters with thermostat designed to operate over 480 volt (1 phase or 3 phase) require a control system to reduce the primary voltage to 120 volts for the control circuit. For increased thermostat life, use a control system on all heaters above 277 volts either single or three phase. These control systems allow for quick electrical installation of all HOTSTART engine preheaters. They are designed as a time and labor saving component. They are especially useful on installations that require two coolant heaters or combinations of a coolant heater and oil heater/hydraulic heater etc. All control boxes on this and preceding page are NEMA 12 & 13. All control boxes are available for Class 1 Group D hazardous locations. Change prefix JBW to JBE and consult factory for price and availability.
L1 Power In 480V 3PH L2 L3 Control Transformer 480V. PRI. H2 H3 1A. Fuses H1 Magnetic Contactors
C1
C1
C1
C2
C2
C2
H4
X1 1/2A. Fuse
120V. 50VA
X2 10A. Fuses
Line
E1
E2
E3
E4
E5
E6
Thermostat 3 Thermostat 3
Model JBW24-200 With pressure switch or Model JBW24-100 With 24 volt relay
To control two 480 volt heaters at maximum 30 amps on automatic start engines.
3 Phase Only
L1
H1
X2
To control one 480 volt heater at maximum 30 amps on manual start engine.
Customer Support: (509) 536-8660 Toll-Free FAX: (800) 224-5550 www.hotstart.com
39
CAUTION
Prior to heater installation, check the cooling system. Poor coolant conditions will interfere with proper function of the heater and can also cause element failure. If there is sediment or foreign matter present or the coolant does not meet the engine manufacturers specifications, the system should be drained, cleaned, flushed and refilled with a 50/50 mixture of low silicate antifreeze, deionized water, and low silicate supplemental coolant additives. Do not exceed a concentration of more than 60% antifreeze, as element failure may result. A cooling system containing anti-leak additives can cause premature element failure. MOUNTING Mount the tank heater in a horizontal position with the outlet neck pointed up. The heater can also be mounted vertically with the inlet neck as the low point (see figure 1). Bolt the heater to the truck frame or skid frame on a generator package with the mounting straps provided. See Figure 2. The heater must be mounted below the lowest level of the engine water jacket to ensure a good gravity flow of coolant to the heater.
Outlet Neck
Outlet Neck
Inlet Inlet
VERTICAL MOUNT
CAUTION
DO NOT mount the heater to the engine. Engine vibration can damage the heater and void the warranty. Connect the heater intake to the lowest accessible point of the water jacket. If a connection point is unavailable in the water jacket area, connect heater intake line to lower radiator hose. This hose should run down to heater intake. Connect heater outlet to the highest accessible point in the engines water jacket area at the furthest point from the engines thermostat. The heater outlet must be connected at a higher point on the engine than the intake. See Figure 3.
YES
FIGURE 2
YES
NO
CAUTION
DO NOT route outlet hose above engine block connection, or loop or kink hoses. This will cause air locks in the hose and block circulation of the coolant by the heater. See Figure 3. To eliminate air locks in the heater and hoses, refill the engine with the heater outlet line disconnected at the engine until outlet line is full of coolant. See Figure 4-1. Then connect the outlet line to the engine and finish filling the engine. See Figure 4-2. Before energizing heater, all air must be bled out of the system by running the engine. If not, air could be trapped in the block causing the heater to fail.
FIGURE 3 YES 1 2 NO
NO
CAUTION
The bi-directional ball check valve located in the inlet of the heater allows a reduced amount of coolant to reverse flow through the heater when the engine is running. This will maintain a full coolant level in the tank at all times to protect the element from overheating. This is a safety device only. Kim Hotstart recommends NOT running the engine with the engine heater energized. On standby and automatic start engines, heaters should be de-energized when engine starts. This requires an oil pressure switch or other automatic cut-off. These systems are often operated at voltages above the 277 Volt rating of the Kim Hotstart thermostat and are also often 3 Phase. All heaters above 277 Volt should be used in conjunction with a contactor and control transformer. All three phase heaters must be used with a contactor. See pages 37, 38, and 39.
Coolant Flow
FIGURE 4
Note: It is recommended for V engines larger than eight cylinders or over 1000 C.I.D. that 2 heaters of equal wattage be used. One heater installed on each bank of the V . Example: To adequately heat a 1000 cubic inch V engine for ambient temperature above -20F use (2) 2000 watt heaters total 4000 watts. For the most efficient heating of this size engine and electrical savings, see the forced circulatiing heating system on pages 16 & 17.
P.O. Box 11245 Spokane Valley, WA 99211-0245
40
Section 5
Battery Pads Battery Wraps Silicone Hot Pads
41
A fully charged battery has only 40% cranking power at 0 F when compared to 100% cranking power at 80 F. Battery heater not recommended for nickel cadmium batteries.
When batteries are placed in an insulated battery box, a thermostat is recommended to sense battery box temperature to prevent overheating the battery.
Style A A
Style C A
6" HPN
100
KB7515-D
KB7515-D
KB7515-D
KB7515-S
80
60
Nominal Model Volts Watts Amps Dimensions Batt. Style Number Size A B KB5015 120 KB5015-S 120 KB5015-D 120 KB7515 120 KB7515-S 120 KB7515-D 120 KB7523 240 KB7523-S 240 KB7523-D 240 50 50 50 75 75 75 75 75 75 .42 .42 .42 .63 .63 .63 .31 .31 .31 8 1/4 8 1/4 8 1/4 13 13 13 4D 4D 4D 8D 8D 8D 8D 8D 8D A B C A B C A B C
40
20
10 1/2 19 1/2 10 1/2 19 1/2 10 1/2 19 1/2 10 1/2 19 1/2 10 1/2 19 1/2 10 1/2 19 1/2
0 -20
+20
+40
+60
+80
Ambient Temperature, F
EXTENSION CORDS Model BEC-2 BEC-4 BEC-6 BEC-8 Length 2 4 6 8 Model BPC-31 BPC-32 BPC-61 BPC-62
THERMOSTAT & Y CORD ASSEMBLY Model BY-T68 Temperature Control On 60F Off 80F
42
Prolong the life of your battery with HOTSTART thermal battery wraps with or without thermostat. Durable, fire-retardant vinyl cover that resists oils and acids. All standard battery pads and battery wraps come with 6 grounded cord and plug. Fast, easy installation. Boosts battery cranking power as much as 75%.
Thermostatically controlled battery thermal wraps provide optimum heating regardless of ambient temperature. At 80F, the battery will achieve maximum cold cranking amps. Battery is constantly maintained at 80F. Provides greater heat rise than plates or pads. Thermostat will eliminate battery damage caused by overheating and acid spill.
www.hotstart.com
43
Dimensions 4 x 5 4 x 5 5 x 6 6 x 8
Application Guidline
Engine oil pan Diesel Tank Hydraulic Tank Water Tank
100 Watt
2 to 5 quarts 5 to 7 gallons 1 to 5 gallons up to 2 gallons
150 Watt
5 to 8 quarts 7 to 10 gallons 5 to 10 gallons 2 to 4 gallons
250 Watt
2 to 5 gallons 10 to 20 gallons 10 to 20 gallons 4 to 7 gallons
400 Watt
5 to 8 gallons 20 to 30 gallons 20 to 30 gallons 7 to 10 gallons
CAUTION: Do not use pads with higher than recommended wattage for specific oil capacities.
44
Section 6
In-block Heaters Heater Installation Guide In-line Heater Direct Immersion Cords Thermocords Flush Mount Kits
45
In-Block
Engine Model
Note: In-block heaters are complete with 2-wire w/ground 6 foot HPN cord and plug. For cord replacements or Y thermocord energy saver, please reference page 56.
Watts
Product Image
Application Information
Allis Chalmers
670T & I 685T & I 6138LT, T & I 25000 (844 CID) AC-101 CATV-151 AC-102 CATV-152 1000 1500 Replaces 1 thread-in plug on the oil cooler at rear of the engine on the right side. Note that not all of the engines have this opening.
Case/IH Agricultural
ALL 4 CYL 390 ALL 6 CYL 590 ALL 6 CYL 830 CUB-751FP CUB-101FP CUB-151FP CUC-151FP CUB-752FP CUB-102FP CUB-152FP CUC-152FP 750 1000 1500 1500 Inserts in any of the freeze plugs right side of engine Inserts in the freeze plug right rear of the block 22mm
22mm
Caterpillar
C-10 C-12 C-9 Non ACERT C-15 Non ACERT C-16 Non ACERT C7 ACERT 3126 C7 ACERT rear port C9 ACERT C11 ACERT C13 ACERT C15 ACERT w/o breaksaver C15 ACERT with breaksaver C9 2007 ACERT C13 2007 ACERT C15 2007 ACERT 1674 1693 & D343 1693T & 1693TA 3013 1.5L 3014 2.0L TF121-000 TF122-000 1250 Replaces the 1 threaded plug in the oil cooler bonnet C-9 Only: Mount in rear face of block C-15, C-16: Mount in rear oil cooler bonnet from the back end Replace 44mm frost plug on right hand side of engine just below the turbo charger. Replace 1-1/16 plug in the rear of the block 1500 1500 1500 1500 Replace 1 NPT plug in the right rear of the engine block Replace any of the 1-5/16 plugs in rear of oil Check Exhaust cooler on the right hand side of the engine Routing Replace 1-3/16 plug in rear of the oil cooler on the right hand side of the engine Replace 1-5/16 plug in the oil cooler on the righ handside of engine Replace 1-3/16 plug in the rear of the oil cooler on the right hand side of the engine Replaces the 1-1/2 thread-in plug on the right side of the engine Replaces water jacket access plate on the left side of the engine Replaces water jacket access plate on the left side of the engine Replaces 40mm core plug on the front, left side of the engine 1 5/16 STOR YES YES 1 NPT
1 NPT
TF151-012
TF152-012
1500
* If supplemental oil heating is desired, this column gives the correct thread size in oil pan. See NOTE on page 54.
46
In-Block
Engine Model
Note: In-block heaters are complete with 2-wire w/ground 6 foot HPN cord and plug. For cord replacements or Y thermocord energy saver, please reference page 56.
Watts
Product Image
Application Information
Caterpillar Continued
3024 2.22L FP531-003 FP532-003 530 Replaces 40mm core plug on the front, left side of the engine Replaces 50mm core plug located at back of head Mounts in football shaped opening on the right of the engine Replaces 35mm core plug located at rear of engine, left side Mounts in the 1-1/4 freeze plug opening on the left side of the engine Mounts in 1-1/4 freeze plug at left rear of engine Mounts in the 1-1/2 freeze plug on the right side of the engine Replaces the core plug on the right side of the engine just below the turbocharger Replaces the 3/4 plug on the right side of the engine just below the head. Replaces the 1 threaded plug in the oil cooler bonnet Replaces 1 threaded plug in oil cooler bonnet Replaces the core plug on the right side of the engine just below the turbocharger Use on industrial engines when clear access is available. Replaces any core plug - one on each side of the engine Replaces any of the 3/4 or 1 plugs on the water transfer casting (right front of the engine). 3/4 use JD3/4 1 use JD1 Replaces the 3/4 plug on the left side of the engine Replaces 1 thread-in plug in the rear of the oil cooler bonnet on the right side of the engine 1 NPT YES YES
3034 2.95L
FP531-001
FP532-001
530
3044 3.3L
PF531-001
PF532-001
530
3056 6.0L
PER-151FP
PER-152FP
1500
3114 3116 3176 10.3L through 1995 3176 10.3L 1996 and later 3196 12.0L 3204 all 1100 series
YES
11/16X12
1 NPT
11/16X12 11/16X12
22mm
3208 2 heaters with a single cord 3208 Recommended Aftermarket Installation 3304 3306 3406C/E 14.6L
CATX-2-751-Y
CATX-2-752-Y
1500 total 1000 1000 1500 1500 1000 1250 1500 1000 1500
* If supplemental oil heating is desired, this column gives the correct thread size in oil pan. See NOTE on page 54. Customer Support: (509) 536-8660 Toll-Free FAX: (800) 224-5550 www.hotstart.com
47
In-Block
Engine Model
Note: In-block heaters are complete with 2-wire w/ground 6 foot HPN cord and plug. For cord replacements or Y thermocord energy saver, please reference page 56.
Watts
Product Image
Application Information
Caterpillar Continued
3406 & 3408 except 1998 ADEM 2 3406E 1998 ADEM 2 engines only 3406E ADEM 3 and ADEM 2000 engines AC-101 CATV-151 AC-102 CATV-152 1000 1500 Replaces 1 thread-in plug in the rear of the oil cooler bonnet on the right side of the engine Replaces the 1 threaded plug that points downward on the top of the rear of the oil cooler bonnet Replaces 1 thread-in plug in the rear of the oil cooler bonnet on the right side of the engine Replaces 1 thread-in plug in the rear of the oil cooler bonnet on the right side of the engine 1 NPT
TF151-002
TF152-002
1500
YES
1 NPT
AC-101 CATV-151
AC-102 CATV-152
1000 1500
1 NPT
3456 15.8L
AC-101 CATV-151
AC-102 CATV-152
1000 1500
1 NPT
Cummins
6 Cylinder Engines: H, NT, NH, N Family 743 CID, 855 CID, 927 CID,N14 1. Cummins engines are often referred to by their horsepower rating i.e. 350 Cummins 2. Cummins engines are often referred to as Big Cam, Big Cam2, 3, 4, full flow cooling, etc. All refer to engines of 855 CID Size listed below Group I Flat plate design CUN-151B CUN-152B 1500 6 bolt flat plate on the right side of the engine. May use either the forward or rear opening depending on clearance. CUN-151BH CUN-152BH 1500 1 NPT 1 NPT
Flat plate design when the 1/2 NPT opening is used Group II
When an external oil cooler is used.. When connection is 1 1/2 rubber hose CNT-151B-90 Engines produced Aug. 1975 thru June 1982 Uses an O ring for the 1 1/4 water tube connection Engines produced prior to August 75
Note: When a 4 bolt flat plate element design is encountered, remove the next two bolts on the casting, remove the whole casting, and replace the casting and element with either CNT-151B/CNT-152B OR CNT151B90/CNT152B90 6 bolt, flat plate design with an elbow that will rotate 360 degrees to connect with any hose or casting
CNT-152B-90
1500
1 NPT
CNT-151B
CNT-152B
1500
6 bolt, flat plate design with an elbow that will rotate 360 degrees to connect with any hose or casting
1 NPT
* If supplemental oil heating is desired, this column gives the correct thread size in oil pan. See NOTE on page 54.
48
In-Block
Engine Model
Note: In-block heaters are complete with 2-wire w/ground 6 foot HPN cord and plug. For cord replacements or Y thermocord energy saver, please reference page 56.
Watts
Product Image
Application Information
Cummins Continued
Group III For industrial engines with hole pattern CUN-151BREV reversed Group IV 1998 and later N14 Industrial Six bolt flat plate on the right side of the block CUN-152BREV 1500 Six bolt flat plate on the right side of the block 1 NPT
PF151-002
PF152-002
1500
1 NPT
TF751-002
TF752-002
750
22mm
PF151-003
PF152-003
1500
1 NPT
PF151-004
PF152-004
1500
27mm
4BT 3.9L
22mm
6BT 5.9L
22mm
6CT 8.3L
22mm
Detroit Diesel
SERIES 10 4 cylinder Phaser engines SERIES 10 6 cylinder Phaser engines SERIES 30 PER-751FP PER-101FP PER-752FP PER-102FP 750 1000 Mounts in the 1-1/4 freeze plug opening on either side of the engine Mounts in the 1-1/2 freeze plug on the right side of the engine Mounts in the 3/4 NPT opening in the block
PER-151FP
PER-152FP
1500
DD8L-101
DD8L-102
1000
* If supplemental oil heating is desired, this column gives the correct thread size in oil pan. See NOTE on page 54. Customer Support: (509) 536-8660 Toll-Free FAX: (800) 224-5550 www.hotstart.com
49
In-Block
Engine Model
Note: In-block heaters are complete with 2-wire w/ground 6 foot HPN cord and plug. For cord replacements or Y thermocord energy saver, please reference page 56.
Watts
Product Image
Application Information
3/4 NPT
SERIES 55 3-53, 4-53, 3-71, 4-71 with water cooled air compressor 3-53, 4-53, 3-71, 4-71 without water cooled air compressor 6-71 with water cooled air compressor 6-71 without water cooled air compressor 8.2 L V-8 Diesel 6V-53 with water cooled air compressor 6V-53 without water cooled air compressor 6V71 & 8V71 Alternate location 6V-71 & 8V-71 6V-92 & 8V-92 except GMC General models 6V92 & 8V92 alternate location threads into oil cooler.
PF151-000
PF152-000
1500
DD-751-S
DD-752-S
750
DD-751
DD-752
750
DD-151-S
DD-152-S
1500
DD-151
DD-152
1500
DD8L-101
DD8L-102
1000
DD6V-751-S
DD6V-752-S
750
DDV-151B
DDV-152B
1500
Mounts in the square plate on the block Threads into the 3/4 NPT opening in the oil cooler housing.Note - not all engines have this opening
DD8L-101
DD8L-102
1000
Deutz
BF4L913 BF6L913 F3L912 F3L913 OLT221515 plus F6L913 A22M48M (adapter) 1011 SERIES oil cooled engines n/a 150 Use adapter kit to mount the 22MM heater in the 48MM opening 22MM or 48MM
* If supplemental oil heating is desired, this column gives the correct thread size in oil pan. See NOTE on page 54.
50
In-Block
Engine Model
Note: In-block heaters are complete with 2-wire w/ground 6 foot HPN cord and plug. For cord replacements or Y thermocord energy saver, please reference page 56.
Watts
Product Image
Application Information
Deutz continued
1012 4 & 6 cyl 1013 4 cyl 1013 6 cyl PF751-000 PF752-000 750 Mounts in the football shaped plate opening on the oil cooler casting Mounts in the football shaped plate opening on the oil cooler casting Mounts in 30MM plug in water elbow on front of the engine Mounts in the football shaped plate opening on the oil cooler casting
PF121-001
PF122-001
1250
TL151-004
TL152-004
1500
PF751-002
PF752-002
750
Ford
6.9L & 7.3L V-8 diesels through 1993 7.3L V-8 diesels from 1994 on FC101-PY1 None 1000 Mounts in a freeze plug on the engine's block. No replacement cord available. Mounts in the 3/4 NPT plug in the engine's block
TF751-002 DD8L-101
TF752-002 DD8L-102
750 1000
Hino
3.8L, 5.8L, 6.0L, 6.4L, 6.7L, W04C-T, W06E, H06C-T, H07C-B DD8L-101 DD8L-102 1000 Threads into 3/4 NPT opening in the block YES
Isuzu
4BD1 6BD1 6BG1 6HE1 6SA1 TF401-501 NONE 400 Replaces 1 NPT plug in left rear of engine
Iveco
NEF 4cyl NEF 6 cyl PF751-001 PF752-001 750 Mount in either front or rear opening on right side of engine block
John Deere
With 3/4 plug in the back of the block With 1 plug in the back of the block With 1 5/8 opening on the side of the water jacket JD3/4-101IN JD3/4-151IN JD1-101IN JD1-151IN JD3/4-102IN JD3/4-152IN JD1-102IN JD1-152IN 1000 1500 1000 1500 3/4 NPT opening in the rear face of the block 1 NPT opening in the rear face of the block check Exhaust routing
JDS-101
JDS-102
1000
1-5/8 threaded opening on the side of the block in the water distribution channel
* If supplemental oil heating is desired, this column gives the correct thread size in oil pan. See NOTE on page 54. Customer Support: (509) 536-8660 Toll-Free FAX: (800) 224-5550 www.hotstart.com
51
In-Block
Engine Model
Note: In-block heaters are complete with 2-wire w/ground 6 foot HPN cord and plug. For cord replacements or Y thermocord energy saver, please reference page 56.
Watts
Product Image
Application Information
Komatsu
L10 (10L) M11(11L) CUL-151 CUL-152 1500 Inserts in the forward opening of the heater casting on the right rear of the block Threads into the freeze plug opening in the block
SA6D125
MA-151
MA-152
1500
Kubota
M, B, L Series D905 V1205 D1005 V1305 D1105 V1505 D3000B V4000B D3200B V4300B DH905 VH1205 DH1005 VH1305
TF401-501
N/A
400
Mack
Mid liner E3 MS200 & MS250 Mid liner E5 MS300 E6 engines smooth bore from 1981 on E6 engines threaded freeze plug opening not produced after 81 END 465, 711, EN438, 504, 707, 673, 675, 676 (1957 through 1981) E7 Engines Except E-Tech water pump mount E9, ENDT865, 866 and 1000 series V8 engines Use two heaters MAM-101 MAM-102 1000 Mounts in rear face of block
MAM-151
MAM-152
1500
MASB-151
MASB-152
1500
MA-151
MA-152
1500
PF151-001
PF152-001
1500
Mounts in the plate in either the front or rear face of the block in the water jacket passage. For 2002 engine mounts in rear face of block. Threads into the 3/4 NPT opening on each side of the block
DD8L-101
DD8L-102
2000 total
* If supplemental oil heating is desired, this column gives the correct thread size in oil pan. See NOTE on page 54.
52
In-Block
Engine Model
Note: In-block heaters are complete with 2-wire w/ground 6 foot HPN cord and plug. For cord replacements or Y thermocord energy saver, please reference page 56.
Watts
Product Image
Application Information
MAN
D2840 D2842 D2848 D2866 D2876 PF121-003 PF122-003 1250 Replace football shaped plate in lower water pipe on right side of engine Replace 3 bolt plate on left side of engine. May require adapter if 3 bolt opening is not available on engine. Consult customer service.
PF151-006
PF152-006
1500
Mercedes Benz
MBE904 MBE906 PF101-001 PF102-001 1000 Replace frost plug in rear of engine on right side YES
Massey Ferguson
3 cylinder 4 cylinder 6 cylinder PER-751FP PER-101FP PER-752FP PER-102FP 750 1000 Mounts in any of the 1-1/4 freeze plug openings in the engine
Navistar/International
V800 (796 CID) INLINE 6 CYLINDER all series 312, 360, 414, 436, 466 & 530 6.9L & 7.3L V8 diesels through 1993 7.3L & T444 all series 9.0L V8 diesel AC-101 CATV-151 PER-751FP INTA-121 FR151-001 FC101-PY1 or FC601-501 DD8L-101 AC-102 CATV-152 PER-752FP INTA-122 FR152-001 None 600 DD8L-102 1000 1000 1500 750 1250 1500 1000 Threads into a 1 NPT opening in the oil cooler bonnet Mounts in the frost plug on the left side of the engine. Fits all series of these engines. No replacement cord available. Mounts in a freeze plug above starter 3/4 NPT threaded opening in the block
INT9-101F
INT9-102F
1000
Oliver
ALL EXCEPT 1265, 1365 & 1900 TF751-002 DD8L-101 TF752-002 DD8L-102 750 1000 Threads into a 3/4 NPT opening in the block
FP531-003
FP532-003
530
* If supplemental oil heating is desired, this column gives the correct thread size in oil pan. See NOTE on page 54. Customer Support: (509) 536-8660 Toll-Free FAX: (800) 224-5550 www.hotstart.com
53
In-Block
Engine Model
Note: In-block heaters are complete with 2-wire w/ground 6 foot HPN cord and plug. For cord replacements or Y thermocord energy saver, please reference page 56.
Watts
Product Image
Application Information
Perkins continued
700 Series 704.30 FP531-001 FP532-001 530 Mounts in freeze plug in rear of head
800 Series
Mounts in football shaped plate on the left front of the block Mounts in the 1-1/2 freeze plug opening on the right side of the engine Mounts in the 1-1/4 freeze plug opening on the left side of the engine Mounts in the 1-1/2 freeze plug on the right side of the engine Replaces 1-1/4 freeze plug on right rear of engine. Element should point towards 1 O-clock position. Mounts in 1-1/4 freeze plug opening on right rear of engine with element straight up in 12 O-clock position
PER-151FP
PER-152FP
1500
1103C
FR531-000
FR532-000
530
1104 (4 Cyl) C
PER-751FP PER-101FP
PER-752FP PER-102FP
750 1000
Volvo
D9 D12C Prior to Serial # 250502 D12C After Serial # 250502 TD60, TD61, TD70, TD71, TD100, TD101, VE10, TD120, TD121 PF151-007 PF152-007 1500 Mounts in the "football shaped" plate on the front, right side of the engine
PF151-005
PF152-005
YES
PF121-002
PF122-002
1250 Mounts into threaded opening (44mm) in the front of the engine
YES
VT6-101
VT6-102
1000
Yanmar
3T72HLE 4TN82E D4T YYDXL4.41 TF401-501 N/A 400 1 NPT No replacement cord available
NOTE: The only replacement parts for the direct immersion heaters is the power cord. Please see the power cord section on page 56 for the proper replacement cord set. For thermostat control of in-block direct immersion heaters, see page 56. The energy saver Thermocord is available in various temperature ranges. Supplemental heat for engines using in-block heaters can be achieved by the installation of oil pan heaters in the lube-oil. Reference pages 26 and 27 of this catalog or consult factory.
* If supplemental oil heating is desired, this column gives the correct thread size in oil pan. See NOTE on page 54.
54
Heater Installation
Instructions for: In-block direct immersion heaters Please refer to specific instructions that accompany heater.
1. Align cord with pins on the heater and press the cord into the heater. Place clamp around cord & heater. DO NOT PLUG IN HEATER YET! 2. Route the cord, keeping away from hot or moving surfaces. 3. Re-fill the cooling system. Run engine until engine thermostat opens and continue running for another 20 minutes to eliminate air. 4. Stop engine and let cool. Check for leaks. Check coolant level. 5. Plug heater into power supply and test for proper operation. Block should feel warm near heater.
1. Align cord with pins on the heater and press the cord into the heater. Place clamp around cord & heater. DO NOT PLUG IN HEATER YET! 2. Route the cord, keeping away from hot or moving surfaces. 3. Re-fill the cooling system. Run engine until engine thermostat opens and continue running for another 20 minutes to eliminate air. 4. Stop engine and let cool. Check for leaks. Check coolant level. 5. Plug heater into power supply and test for proper operation. Block should feel warm near heater.
1. Align cord with pins on the heater and press the cord into the heater. Place clamp around cord & heater. DO NOT PLUG IN HEATER YET! 2. Route the cord, keeping away from hot or moving surfaces. 3. Re-fill the cooling system. Run engine until engine thermostat opens and continue running for another 20 minutes to eliminate air. 4. Stop engine and let cool. Check for leaks. Check coolant level. 5. Plug heater into power supply and test for proper operation. Block should feel warm near heater.
www.hotstart.com
55
IM6-1IN
IM6-2IN
11
IM11-1IN
IM11-2IN
Heat Shield
Model No.
16 Cord Length 6
1 Plug Style 2
IM16-1IN
IM16-2IN
Fits most competitor's applications.
120 Volt
240 Volt
STYLE 2
HS1
11PR72T
21PR72T
11
11PR132T
21PR132T
16
11PR192T
21PR192T
IM6-1IN 11PR72T
NOTE: When ordering in-block heater and thermocord, place suffix WOC (which stands for without cord) after the heater model number to save cost as the standard 6 foot heater cord is replaced by the thermocord harness.
Y ERG EN VER SA
3 ft.
80-100
56
Plug Style 2 2 2
6 11 16
Kits include: 11PR- style cord (shown on page 56), recessed male receptacle and hinged flip cover
.3125
Kits include: Recessed male receptacle with 6 cord (no female connectors), hinged flip cover and female connector
.3125
Other Accessories
Recessed Male Receptacle with 6 ft. cord (no female connectors)
Model Number RM5-15 RM6-15 RM5-2 RM6-2 Model Number FM1G2A FM2G2A Volts 120 240 120 240 Volts 120 240 Amps 15 15 20 20 Amps 15/20 15/20
3.3125
Plug Housing
Model Number A-2223-PH
www.hotstart.com
57
1. Determine the best type of heater to be used for the application. Direct Immersion or Tank Type? Weathertight unit for all indoor or outdoor applications (hospital, communications building, shopping mall, pump station, off-road equipment). Explosion Proof unit for Hazardous Locations (off-shore platform, oil rig, gas compression station). 2. Determine engine size. Cubic inch or litre displacement. 3. Determine wattage required by using this general formula: 3 watts x cubic inch displacement = watts required. Example: Engine is 855 C.I.D. 855 x 3 = 2565. Requirement is 2500 watt heater. This formula is a very good rule of thumb to use down to 0F ambient temperature. This formula will generally hold engine temperature at approximately 100F above ambient. Very large engines may require a forced circulation system (see pages 16, 17 and 59). 4. Now that you have the required wattage, you need to determine: Voltage available that will power the heater (120, 208, 277, 240, 380, 480). Is the power source Single Phase or Three Phase? 5. For thermostat selection, determine the desired engine temperature to be maintained. 100F to 120F applies 95% of the time. However, specifications vary with respect to the user and a higher or lower range may be required. You now have the specifications needed to select the required engine pre-heater from the many products listed in this catalog. For other technical information and installation tips, see pages 40 and 55. If you have other questions or need additional assistance, please contact our customer service department. Conversion Chart Fahrenheit - Celsius
Litres 49.98 50.80 51.62 52.44 53.26 54.08 54.90 55.71 56.53 57.35 58.17 58.99 59.81 60.63 61.45 62.27 63.09 63.91 64.73 65.55 66.37 67.19 68.00 68.82 69.64 70.46 71.28 72.10 72.92 -40 F -30 F -20 F -10 F 0 F 10 F 20 F 30 F 40F 50F 60F 70F 80F 90F 100F 110F 120F 130F 140F 150F 160F 170F 180F 190F 200F 210F -40 C -34 C -29 C -23 C -18 C -12 C - 7 C - 1 C 4.5C 10.0C 15.5C 21.0C 26.5C 32.0C 37.5C 43.5C 49.0C 54.5C 60.0C 65.5C 71.0C 76.5C 82.0C 88.0C 93.5C 99.0C
Cubic Inches - Litres Conversion Chart Conversion Factors Litres x 1.0567 = Quarts Quarts x 0.94635 = Litres Litres x 0.26417 = Gallons Gallons x 3.7854 = Litres
Cubic Inches 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250 1300 1350 1400 1450 1500 1550 Litres 2.46 3.28 4.10 4.92 5.74 6.55 7.37 8.19 9.01 9.83 10.65 11.47 12.29 13.11 13.93 14.75 15.57 16.39 17.21 18.03 18.84 19.66 20.48 21.30 22.12 22.94 23.76 24.58 25.40 Cubic Inches 1600 1650 1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200 2250 2300 2350 2400 2450 2500 2550 2600 2650 2700 2750 2800 2850 2900 2950 3000 Litres 26.22 27.04 27.86 28.68 29.50 30.32 31.13 31.95 32.77 33.59 34.41 35.23 36.05 36.87 37.69 38.51 39.33 40.15 40.97 41.79 42.61 43.42 44.24 45.06 45.88 46.70 47.52 48.34 49.16 Cubic Inches 3050 3100 3150 3200 3250 3300 3350 3400 3450 3500 3550 3600 3650 3700 3750 3800 3850 3900 3950 4000 4050 4100 4150 4200 4250 4300 4350 4400 4450
58
HOTSTART offers complete circulating heating systems for any large industrial engine. These systems are engineered and designed specifically for installation on a large generator, compressor package, marine engine, or locomotive. Most systems are mounted on a steel plate with a pre-wired junction box, pump and motor components, a flow detection device and in-line high-limit thermostats. Plus, most systems have fused 120 volt control voltage, regardless of applied voltage. Several systems are available for lube oil heating, coolant heating, diesel fuel heating or combinations of any aforementioned fluid. Systems are adaptable to function in wet/damp locations or hazardous environments. Complete with all necessary components and controls, these automated systems are available in various wattage, voltage and phase combinations to accommodate most large industrial preheating needs. For additional information regarding HOTSTARTs circulating heating systems, please contact HOTSTART and have all your questions answered by one of our engine heating product specialists.
Large capacity systems heat and circulate coolant or lube oil to efficiently maintain an engines optimum temperature during shutdown and layover periods.
Circulating-type combination heating systems combine the benefits of coolant heating and oil heating into one prewired, pre-assembled dual heating system.
COR Model for locomotive engines coolant/lube oil combination heating system
COL Model Watertight with NEMA 12 enclosures combination circulating heating system
Customer Support: (509) 536-8660 Toll-Free FAX: (800) 224-5550 www.hotstart.com
59
Customer Services
To better serve you, HOTSTART provides a customer service department to answer all your engine heating concerns, any questions regarding HOTSTART products or to take your sales order. Customer Support Department: (509) 536-8660 Sales orders and requests for quotes can also be faxed in over our toll-free FAX line. Toll-free FAX line: (800) 224-5550
Warranty Information
The warranty below has been drafted to comply with the Federal Law applicable to products manufactured after December 31, 1976. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. HOTSTART products are warranted against defects in workmanship and materials. No other express warranty, written or oral, applies. No person is authorized to give any other warranty or assume any liability except by written statement from an officer of HOTSTART Inc. The warranty extends for twelve months from date of shipment from factory or authorized distributor. Products must be installed and maintained in accordance with HOTSTART Inc. instructions. Users are responsible for the suitability of the products to their application. There is no warranty against damage resulting from corrosion, misapplication, improper specification or other operating conditions beyond our control. Claims against carriers for damage in transit must be filed by the buyer. Absolutely no material can be returned to HOTSTART Inc. without prior factory authorization. Upon factory authorization, return the defective part or product , freight prepaid, to: HOTSTART Inc., 5723 E. Alki, Spokane Valley, WA 99212. Telephone (509) 534-6171; FAX (509) 534-4216. Defective items will be repaired or replaced, at our option, at no charge. Such repair or replacements is the exclusive right of HOTSTART Inc. HOTSTART Inc. is not liable for labor costs incurred in removal, reinstallation, or unauthorized repair of the product or for damage of any type whatsoever including incidental or consequential damage. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the preceding limitation or exclusion may not apply to you. HOTSTART Inc.
Distributor
P.O. Box 11245 Spokane Valley, Washington U.S.A 99211-0245 Phone: (509) 534-6171 Fax: (509) 534-4216 Toll Free Fax: (800) 224-5550 www.hotstart.com
12-09
60