ABC DQ Transformation
ABC DQ Transformation
ABC DQ Transformation
Description
The dq0_to_abc Transformation block performs the reverse of the so-called Park transformation,
which is commonly used in three-phase electric machine models. It transforms three quantities
(direct axis, quadratic axis, and zero-sequence components) expressed in a two-axis reference
frame back to phase quantities. The following transformation is used:
The transformation is the same for the case of a three-phase current; you simply replace the Va,
Vb, Vc, Vd, Vq, and V0 variables with the Ia, Ib, Ic, Id, Iq, and I0 variables.
The dq0_to_abc Transformation block is used in the model of the Synchronous Machine block
where the stator quantities are referred to the rotor. The Park transformation then eliminates
time-varying inductances by referring the stator and rotor quantities to a fixed or rotating
reference frame. The Id and Iq currents represent the two DC currents flowing in the two
equivalent rotor windings (d winding on the same axis as the field winding, and q winding in
quadratic) producing the same flux as the stator Ia, Ib, and Ic currents.
Connect to the first input a vectorized signal containing the sequence components [d q 0]
to be converted.
sin_cos
Connect to the second input a vectorized signal containing the [sin(ωt) cos(ωt)] values,
where ω is the rotation speed of the reference frame.
abc
The output is a vectorized signal containing the three-phase sinusoidal quantities [phase
A phase B phase C], in the same units as the dq0 input signal.
Example
See the demo of the abc_to_dq0 Transformation block for an example using the dq0_to_abc
Transformation block.