MDE-4039 Encore Programming QR
MDE-4039 Encore Programming QR
MDE-4039 Encore Programming QR
1. Power up unit
2. Set Calibration switch to ON
3. Press F1
4. Press 90 (Side 1) or 91 (Side 2)
5. Press Enter
6. Enter prover can size (5 gallons is
normal and minimum
recommended size for
accuracy)
7. Press Enter
8. Raise handle or select grade and
dispense fuel to zero indicator
on can
Prover can
size
Main
display
Over or under
condition
(0 or 9)
Function
code
PPU
Bar
Amount over
or under
Error Codes
Code Description
20
Pulser Fail
24
Conversion Factor Changed/
Not Programmed
25
Two-Wire/Standalone Mode
Changed
26
Meter Not Calibrated
27
Side 1 Two-Wire ID Changed
28
Side 2 Two-Wire ID Changed
29
Pump Time-Out Error
30
VaporVac Fail Both Sides or
Vapor Sense 5
31
Totals Data Error
32
Pulser Count Error
33
VaporVac Fail One Side or
Push-To-Stop Button Activated
35
Configuration Data Error
36
Unit Type Configuration Code
Changed
37
PIN Code 1 Changed
38
PIN Code 2 Changed
39
Cash/Credit Option Changed
40
Master Reset Jumper in Place
41
Side Exists Option Changed
44
Pump Handle Up at Power Up
Description
Blends Not Programmed
No Blend Table
Low Product Low Flow
Hi Product Low Flow
Low Product No Flow
Hi Product No Flow
Hi Product Contaminated by Lo
Lo Product Contaminated by Hi
Leaky Valve
Single-Hose MPD
Code Description
4350 Valve Control Option Not
Programmed (see CC17)
4351 Valve Leaks - Grade 1
4352 Valve Leaks - Grade 2
4353 Valve Leaks - Grade 3
4355 Valve Leaks - Grade 1 & 2
4356 Valve Leaks - Grade 1 & 3
4358 Valve Leaks - Grade 2 & 3
MDE-4039
Encore 300 Programming
Quick Reference Card
Software Versions
For detail on software versions see MDE-3804 Encore and Eclipse Service
Manual. Power-up and Command Code 8 display the current software version.
From Level 2:
Command Code 10:
System Configuration
Press ENTER after making selections.
Enter 10.
Enter Function #.
Enter Configuration #.
Function Code 1 (For non-blenders only:
Unit Type
Self configures default value.
1 = 1 product
2 = 2 product
3 = 3 product
Function Code 2: Money Decimal Point
1 = xxxxx
2 = xxxx.x
3 = xxx.xx *
4 = xxx.xxx
Function Code 3:
Calculation PPU Decimal Point
(Required in U.S. per Weights & Measures)
1 = xxxx
2 = xxx.x
3 = xx.xx
4 = x.xxx *
Function Code 4:
Displayed PPU Decimal Point
Self configures default value.
1 = xxxx
2 = xxx.x
3 = xx.xx
4 = x.xxx
* Default
*
3
Default
Must be programmed to 1 in New Jersey.
From Level 3:
Command Code 13:
Pin Code Change
Press ENTER after selections.
Enter 13
Enter Level # 1, 2 or 3
Enter new PIN Code
Unit returns to Command Input Mode.
Command Code 15:
Function Code 1:
Preselect Time-Out
0 - 999 seconds
Meter Calibration
Refer to MDE-3804 Service Manual
for detail.
Note: Before calibrating meter(s),
Conversion Factor must be entered
first in Command Code 17
WARNING
Function Code 2:
Pump Time Out
0 - 999 seconds
Function Code 3:
Beeper Time Out
0 - 999 seconds
Function Code 4:
Slowdown Valve
0 - 0.999 gallons
* Default