Centrifugal Pump Data Sheet: (Cwip-I Kalol)

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

ANNEXURE-1

CENTRIFUGAL PUMP DATA SHEET


(CWIP-I KALOL)
(SINGLE STAGE HORIZONTAL CENTRIFUGAL PUMP)
APPLICABLE TO PROPOSAL PURCHASE AS BUILT
FOR BOOSTER PUMPS-3nos. AT CWIP-I KALOL
SITE_______________
UNIT _____________EFFLUENT TRANSFER PUMP
SERVICE____________CONT. TRANSFER OF TREATED
EFFLUENT/WATER
REMARKS_____________SALINITY 10-12 GM/LIT
OPERATING CONDITIONS(TO BE COMPLETED BY PURCHASER)
LIQUID HANDLED : CONT. TRANSFER OF TREATED
EFFLUENT/WATER
PUMPING TEMPERATURE(C)
NORMAL________40C____MINIMUM 15C _____MAXIMUM 60C
SPECIFIC GRAVITY @ PT_______1.005__________
VAPOR PRESSURE AT PT( kg/cm2 g)_____________
VISCOSITY @ PT (CST)__________1.0 TO 2.0______CP____
ACCELERATION HEAD (m)_________________
NPSH AVAILABLE (m)___FLOODED SUCTION
WITHOUT ACCELERATION HEAD (m)______ACTUAL____
ELECTRICAL AREA CLASSIFICATION
CLASS__II__GROUP___A/B________HAZARDOUS______
SITE TEMPERATURE(C)
NORMAL____30C____MAXIMUM 50C_____ MINIMUM 10C
CORROSION/ERROSION CAUSED BY _________________
pH : 7.5 TO 8.5

JOB NO.:________ITEM NO_____


RESUISATION NO _________________
PAGE__________OF_________BY______
NO OF PUMPS REQUIRED_________3(THREE)
DRIVER TYPE_FLP SQ.CAGE.IND.MOTOR
DRIVER FURNISHED BY_________________
MANUFACTURER_____**____REMARKS__________
SIZE AND TYPE________________________
PUMP SERIAL NO_______________________
CAPACITY @ PT (M3/Hr)
MAXIMUM _____ MINIMUM ____RATED 51.01M3/Hr OR (14.17
LT/SEC)
DISCHARGE PRESSURE ( kg/cm2 g)
MAXIMUM _____ MINIMUM ____RATED 2.0 KG/CM2
SUCTION PRESSURE ( kg/cm2 g)
MAXIMUM _____ MINIMUM ____RATED FLOODED
DIFFERENTIAL PRESSURE ( kg/cm2 g)
MAXIMUM _____ MINIMUM ____RATED _______
LOCATION
INDOOR
HEATED
OUTDOOR
UNHEATED
DIFFERENTIAL HEAD (m)_________________
REMARKS________________SUCTION IS FLOODED
PUMP SHALL BE LOCATED IN HAZARDOUS AREA
___________________________________

PUMP CHARACTERISTIC (TO BE COMPLETED BY PURCHASER AND MANUFACTURER)


DESIGN PRESSURE____________________
SUCTION SIDE FLANGE :
NO OF STAGES___SINGLE________
SIZE______
RATING_______
SPEED IN RPM ________2900_______________
FACING______
POSITION______
EFFICIENCY__________________
DISCHARGE SIDE FLANGE :
RATED POWER(KW) : PRIME MOVER -2.1KW
SIZE______
RATING_______
IMPELLER DIAMETER (mm)______________
FACING______
POSITION______
CASING MAWP ( kg/cm2 g) ______________
LUBRICATION TYPE_____________
HYDROTEST PRESSURE ( kg/cm2 g) ________
PACKING MFR./TYPE _________/___________
COUPLING MFR./TYPE _________/___________
GLAND TYPE/MATERIAL _________/___________
MAKE/MODEL NO : 50/13 KPS
PROPOSAL CURVE NO_________________
CASING TYPE/MOUNTING/SPLIT (HOR./VERT.)_HORIZONTAL___________________/________________
REMARKS :
MATERIAL OF CONSTRUCTION ( TO BE COMPLETED BY PURCHASER AND MANUFACTURER)
CASE
CARBON STEEL_________
BASE PLATE
M.S____________
IMPELLER
SS316_________
SHAFT SLEEVE_________
SS316__________
SHAFT
SS316_________
WEAR RING _________
SS316__________
REMARKS _________________________________
MOUNTING PLATE ( TO BE COMPLETED BY PURCHASER AND MANUFACTURER)
BASEPLATE
SKIDPLATE
SOLEPLATE
OPEN BEAM SUPPORT ___________________________
BY PUMP MANUFACTURER ____________
FULLY GROUTED
UNGROUTED
DECKING __________________________
OVERALL SIZE _____________________________
REMARKS ___________________________

OWNER

LSTK CONTRACTOR
ONSHORE DESIGN
GROUP,ONGC,BARODA

ONGC LIMITED
REV. NO. :0 TITLE: CENTRIFUGAL PUMP DATA
SHEET
(CWIP-I KALOL)

SAVAIR ENERGY LIMITED


PROJECT: SOUTH KADI
GGS/CTF/WIP

ANNEXURE-1
DATE_________ REVISION__

OWNER

LSTK CONTRACTOR
ONSHORE DESIGN
GROUP,ONGC,BARODA

ONGC LIMITED
REV. NO. :0 TITLE: CENTRIFUGAL PUMP DATA