Nothing Special   »   [go: up one dir, main page]

Technical Catalouge PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 41
At a glance
Powered by AI
The document provides information on various types of copper and brass tubes, strips and foils including their specifications, dimensions, chemical compositions and applications.

The main types of copper tubes described are refrigeration and air conditioning tubes, water tubes, ACR and gas pipes, condenser and heat exchanger tubes, electrical tubes, and medical and vacuum tubes.

Some of the key standards mentioned for copper tubes include ASTM B68, ASTM B75, ASTM B88, ASTM B111, EN 1057, and JIS 3300.

0

Product Listing
Product: Copper Tube
Standard: ASTM B68, ASTM B75,ASTM B88,ASTM B111,ASTM A280,AS 1571,AS1572 EN 1057, EN 12735-1, EN 12735-2, EN 12449, ASTM B280, STM B68/251, ASTM B88, NF EN, GOST 617, GOST 11383, JUS C.D5-500, JUS C.D5-502
Product Description:
Type Usage O.D. mm) Copper Tube Refrigeration and AirCon Copper Tube Water Tube 6-105 Size ( W.T. mm) 0.4-8 ( C12200/C1220/ DHP C12200/CU-DHP/ CW024A/K/L/M CUASTM B280/ASTM B640/ EN 12735/JIS 3300/AS/NZS 1571 ASTM B88/ANSI/NSF61/ASTM B698/ASTM B467/EN 1057/JIS 3300/NZS 3501/AS 1572 ASTM B68/ASTM B837/EN 1057/JIS 3300/ NZS 3501 ASTM B75/ ASTM B111/ASTM B359/ASTM B543/ EN 12451/ JIS 3300/AS 2378 ASTM B75/ASTM B447/ EN 13600 ASTM B819/EN 13348/EN 1057/BS 2871 ASME B16.22/EN 1254/JIS H3401/BS 864-2 ASTM B111/ EN 12451/JIS 3300/AS 1569 ASTM B111/ASTM B135/ EN 12451/JIS 3300/AS 1569 ASTM B111/ASTM B359/ EN 12451/JIS 3300/AS 1569 ASTMB111/ASTMB346/ASTM B466/ EN12451/ JIS 3300/AS 1569 ASTM B111/ ASTM B346/ASTM B466/ EN 12451/JIS 3300/AS 1572 ASTM B111/ASTM B346/EN 12451/JIS 3300/AS 1569 ASTM B743/AS 1571 Alloy Number Specification

9-300

0.4-60

ACR, GAS Pipe Condenser & Heat Exchanger Electrical Tube Medical & Vacuum ACR/Pipe/Gas line Pipe fittings Admiralty Brass Tube Common Brass Tube Aluminum Br ass Tube 90/10 Cu-Ni Tube 70/30 Cu-Ni Tube

9-76 6-108

0.4-8 0.4-8

C10200/C12000/ C12200 C12200

9-76 9-300 6-108

0.4-8 0.4-60 0.4-8

C10100/C10200/ C10 300/C12000 C12200 C12200

Copper Fittings Brass Tube

4-100 4-100 4-100 4-100

0.4-12 0.4-12 0.4-12 0.4-12

C44300/ CuZn28Sn1/ HSn70-1 C27200/C27400 C68700/C6870/ CZ110 C70600/C7060/ CN102 C71500/C7150/ CN107/C26000 C71640 C10200/C12000/ C12 200/C12200

CopperNickel T ube

4-100

0.4-12

4-100 Pair Coils Insulated Jacket Tube 6.3519.05 /24-41

0.4-12 0.81.22 / 8-10

Specifications:
ASTM B42-This specification covers seamless copper pipe in all standard pipe sizes, both regular and extra strong, suitable for use in plumbing, boiler feed lines, and for similar purposes. ASTM B43-This specification covers seamless red brass (Copper Alloy UNS No. C23000) pipe in all standard pipe sizes, both regular and extrastrong, suitable for use in plumbing, boiler feed lines, and for similar purposes. ASTM B68-This specification covers annealed seamless copper tube suitable for use in refrigerators, oil lines, gasoline lines, etc.., where tube absolutely free from scale end dirt is required. ASTM B75-This specification covers seamless copper, round and rectangular including square tube suitable for general engineering purposes. ASTM B88 : 99 (Copper Water and Gas Tube)- This specification covers hard drawn temper, seamless copper tubes which are suitable for use in general plumbing applications, such as underground water service, potable water distribution, gas distribution and fire sprinkler installations. To assist with selection this standard is separated into three Types - K, L and M. Each type is differentiated by a range of wall thicknesses, with Type K having thicker walls than Type L, and Type L being thicker than Type M, for any given diameter ASTM ASTM B111/ASME SB111-This specification covers seamless tube and ferrule stock of copper and various copper alloys up to 2 .in.. (50.8mm), inc., in diameter, for Use in surface condensers, evaporators, and heat exchangers. ASTM B135-This specification covers seamless round and rectangular including square copper alloy tube in straight lengths.. ASTM B251-This specification covers a group of general requirements common to several wrought product specifications. Unless otherwise specified in the purchase order, or in an individual specification, these general requirements shall apply to copper and copper-alloy tube supplied under specifications B 68, B 75, B135, and B466 ASTM B280-This specification covers seamless copper tube for air conditioning and refrigeration service and intended for use in the field for connection, repairs, and alterations. ASTM B302-This specification covers threadless, seamless, deoxidized copper pipe (TP) in straight lengths, for piping systems that are assembled with brazed-joint pipe fittings. ASTM B306-This specification covers seamless copper drainage tube (DWV) intended for use with soldered fittings for sanitary drainage, such as soil, waste, and vent piping.
6

ASTM B152 Alloy C11000- Standard Specification for Copper Sheet Strip, Plate and Rolled Bar. ASTM B584 Alloy C84400- Standard Specification for Copper Alloy Sand Castings for General Applications. Federal Specification WW-U-516 for Type Ill, Class A and Class B Copper Alloy Unions. ASTM B677 Standard Specs for UNS N08904, UNS N08925, and UNS N08926 Seamless Pipe and Tube. BS EN 1057 has replaced the British Standard BS 2871 Part 1 and other conflicting standards previously used. This standardization with EN 1057 has provided a common standard for many markets. However, as there are no dimensional changes, all EN 1057 tube is totally compatible with current BS tube and fittings. BS EN 13348-Copper Medical Gas Pipes, Complies with the latest HTM02-01 medical gas pipeline systems standard BS EN 1254-Medical Gas fittings BS EN 13600: Copper and copper alloys Seamless copper tubes for electrical purposes

AUSTRALIAN STANDARDS
AS 1432 Copper tubing for plumbing, gas fitting and drainage applications. This standard provides for round seamless copper tubes intended for use in pressure and nonpressure plumbing, gas fitting and drainage applications in hard drawn, bending quality, annealed, and plastic lagged coils and straight lengths. Inert plastic lagging is available for this product coloured in green for potable drinking water and lilac for recycled water applications. AS 1571 Copper - Seamless tubes for airconditioning and refrigeration. These tubes are supplied in both hard drawn straight lengths and annealed coils, after meticulous cleaning, dehydrating and capping, to ensure that the internal cleanliness standards are fully met. The intended use for this product is in airconditioning and refrigeration applications. AS 1572 Copper - Seamless tubes for engineering purposes. This Standard specifies seamless copper and copper alloy tubes for general purposes. It does not apply for heat exchangers or tubes for airconditioning. NZS 3501 : 1976 Copper Tubes for water, gas and sanitation This copper tube is manufactured in straight lengths, in half hard condition and in fully annealed coils.

Material Cartridge Brass Tube (UNS-C2600) Yellow Brass Tube (UNS-C2700) Low-Leaded Brass Tube (UNS-C3300) Bronze Tube Brass Tube Al-Brass Tube (UNS-C68700, C69710, C6872T) Cu-Ni Tube (UNS-C70600) Cu-Ni TUbe (UNS-C71500) Alloy Tube (UNS-C71640) Commercial Bronze Tube ( UNS-C2200) Red Brass Tube (UNS-C2300) Though Pitch Copper Tube (UNS-C1000) Deoxidized Copper Tube (UNS0C1220) Oxygen Free Electronic Copper Tube Oxygen Free Copper Tube (UNS-C1020) Federal specifications. ANSI B16.22-WROT PRESSURE SOLDER-JOINT FITTINGS ANSI B16.18-CAST PRESSURE SOLDER-JOINT FITTINGS ANSI B18.26-CAST BRONZE FLARED TUBE FITTINGS ANSI H23.1, ASTM B88 and WWT-799 -STREAMLINE COPPER TUBE TYPES K, L & M ANSI B70.1 and SAE J513-REFRIGERATION FLARE-TYPE FITTINGS ANSI H23.5, ASTM B280, and WWT-775 -STREAMLINE COPPER REFRIGERATION SERVICE TUBE ANSI H23.1 Type L, and ASTM B88,Type L, in accordance with ASTM B280-STREAMLINE NITROGENIZED ACR HARD DRAWN COPPER TUBE OXYGEN SERVICE TUBE To ANSI H23. 1 Types K and L and ASTM B88, Types K and L hard drawn lengths only - in accordance to CDA cleanliness specifications and NFPA 56F, Seamless Copper Tube cleaned for Oxygen Gas Service WROT DWV SOLDER-JOINT FITTINGS To ANSI B16.29 CAST DWV SOLDER-JOINT FITTINGS To ANSI B16.23 STREAMLINE COPPER TUBE TYPE DWV To ANSI H23.6 and ASTM B306 COPPER PIPE To ASTM B42 RED BRASS PIPE To ASTM B43

Standard Met RJ Seamless Copper Pipe : RJ Copper pipe is almost pure copper manufactured to the requirements of ASTM B 42 - Standard Specification for Seamless Copper Pipe, Standard Sizes. It may be manufactured from any of five (5) copper alloys (C10200, C10300, C10800, C12000, C12200) that all conform to the chemical composition requirements of alloys containing a minimum of 99.9% Copper (Cu) and a maximum of 0.04% Phosphorous (P). Available sizes are 1/8 to 12 diameters in regular wall thickness and 1/8 to 10 in extra strong wall thickness. The standard length for copper pipe is 12 feet. Copper pipe is suitable for plumbing, boiler feed lines, refrigeration and for similar purposes. Joints in seamless copper pipe can be threaded, flanged or brazed to fittings of the appropriate joint configuration. RJ Seamless Red Brass Pipe: (Red) Brass pipe is an alloy of copper manufactured to the requirements of ASTM B 43 Standard Specification for Seamless Red Brass Pipe, Standard Sizes. It is manufactured from alloy C23000 which is comprised of approximately 85% Copper (Cu) with no greater than 0.05% Lead (Pb) and 0.05% Iron (Fe) and the remainder Zinc (Zn). Available sizes are 1/8 to 12 diameters in both regular and extra strong wall thickness. The standard length for red brass pipe is 12 feet. Brass pipe is moderately resistant to many corrosive solutions and is often utilized for water supply and distribution. Joints in red brass pipe can be threaded, flanged or brazed to fittings of the appropriate joint configuration. Fittings in the smaller sizes, normally those below 2 diameter are, screwed cast copper alloy or brazed cup cast copper alloy. Fittings above 2 diameter are normally threaded, flanged, brazed or in some cases grooved mechanical joint fittings are employed. RJ Seamless Copper Tube, Bright Annealed: RJ Bright annealed copper tube is an almost pure copper tube manufactured to the requirements of ASTM B 68 Standard Specification for Seamless Copper Tube, Bright Annealed. It may be manufactured from any one of the following alloys: C10200, C10300, C10800, C12000, or C12200 unless specified otherwise on the original contract or purchase order. ASTM B68 tube is suitable for use in refrigeration, fuel oil, gasoline, or oil lines where the interior surface of the tube is essentially free of any scale or dirt and is specifically specified as ASTM B68. This tube is provided in annealed tempers meeting O50 Light annealed or O60 Soft annealed in either straight lengths or coils. It is the responsibility of the purchaser, when ordering to provide the requirements for alloy (UNS#), temper, dimensions (diameter and wall thickness), form (straight lengths or coils), and total length or number of pieces of any particular size. It is this requirement that forces this tube to be a special order tube and not a standard stocked material. There is no specific requirements for identification of B68 tube and thus is not specifically designated as a tube permitted for use in most plumbing or mechanical codes. It is usually limited to use in specific manufacturing processes or production line type applications. RJ Seamless Copper Tube: RJ Seamless copper tube manufactured to the ASTM B 75 Standard Specification for Seamless Copper Tube may be either round, square, or rectangular and is suitable for general engineering applications. It may be manufactured from any one of the following alloys: C10100, C10200, C10300, C10800, C12000, or C12200 unless specified otherwise on the original contract or purchase order.
9

Tubes meeting this standard may be furnished in any of several tempers (H55, H58, H80, O60, or O50) ranging from light drawn (usually limited to round tubes) to light annealed. It is the responsibility of the purchaser, when ordering, to provide the requirements for alloy (UNS#), temper, dimensions (diameter, wall thickness, or distance between parallel surfaces), form (straight lengths or coils), and total length or number of pieces of any particular size. It is this requirement that forces this tube to be a special order tube and not a standard stocked material. It is usually limited to use in specific manufacturing processes or production line type applications. RJ Seamless Copper Water Tube: Copper water tube is a seamless, almost pure copper material manufactured to the requirements of ASTM B 88 Standard Specification for Seamless Copper Water Tube, of three basic wall thickness dimensions designated as types K, L, and M. Type K is the thickest and type M is the thinnest with type L being of intermediate thickness. All 3 types of tube are manufactured from copper alloy C12200 having a chemical composition of a minimum of 99.9% Copper (Cu) and Silver (Ag) combined and a maximum allowable range of Phosphorous (P) of 0.015% - 0.040 %. Seamless copper water tube is manufactured in sizes through 12 nominal. Types K and L are manufactured in drawn temper (hard) through 12 and annealed temper (soft) coils through 2 while type M is only manufactured in drawn (hard) temper through 12. Seamless copper water tube of drawn temper is required to be identified with a colour stripe that contains the manufacturers name or trademark, type of tube and nation of origin. This colour stripe is green for type K, blue for type L and red for type M. In addition to the colour stripe the tube is incised with the type of tube and the manufacturers name or trademark at intervals not in excess of 1 ft. Annealed (soft) coils or annealed straight lengths are not required to be identified with a colour stripe. RJ Seamless Brass Tube: RJ Seamless brass tube is manufactured to the requirements of ASTM B 135 Standard Specification for Seamless Brass Tube and may be either round, square, or rectangular and is suitable for general engineering applications. It may be manufactured from any one of the following alloys: C22000, C23000, C26000, C27000, C27200, C27400, C28000, C33000, C33200, C37000, or C44300 and these alloys contain Copper (Cu) concentrations of between 60% and 90% with various percentages of Zinc (Zn), Lead (Pb), and Tin (Sn) permitted, depending on the alloy. Tubes meeting this standard may be furnished in any of several tempers ranging from light drawn to light annealed. It is the responsibility of the purchaser, when ordering to provide the requirements for alloy (UNS#), temper, dimensions (diameter and wall thickness, or distance between parallel surfaces), form (straight lengths or coils), and total length or number of pieces of any particular size. RJ Wrought Seamless Copper & Copper Alloy Tube ASTM B 251 Standard Specification for General Requirements for Wrought Seamless Copper and Copper- Alloy Tube covers a number of general requirements common to many wrought copper products. A few of these specifications are B 68, B75, B135, B466 and B743. Products manufactured under the requirements of ASTM B251 may be of alloys of copper, brass or copper-nickel and may be produced in any number of tempers or shapes as specified by the purchaser.
10

RJ Air Conditioning & Refrigeration Tube: RJ Copper tube used for air conditioning and refrigeration applications in the field (sometimes called refer or ACR tube) is an almost pure copper material meeting the requirements of ASTM B 280 Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service. It is manufactured from copper alloy C12200 having a chemical composition of a minimum of 99.9% Copper (Cu) and Silver (Ag) combined and a maximum allowable range of Phosphorous (P) of 0.015 % - 0.040 %. B 280 tube is produced in straight lengths or coils in tempers H58 or O60 respectively, although annealed straight lengths may be special ordered. Straight lengths are provided in sizes from 3/8 O.D. through 4 1/8 O.D. while annealed coils are supplied in sizes ranging from 1/8 O.D. through 1 5/8 O.D. ACR tube is required to be identified in the following fashion: Coils: The name or trademark of the manufacturer and ACR shall be permanently incised on each tube or larger at Intervals not greater than 1 ft. Hard Straight Lengths: The name or trademark of the manufacturer and a mark indicating either L or ACR shall be incised at intervals not greater than 1 ft. along the length of the tube. Hard straight lengths shall further be marked with a blue stripe containing the manufacturers name or trademark, the nation of origin, outside diameter and ACR repeating at intervals not greater than 3 ft. Air conditioning and refrigeration tube (ASTM B 280) either coiled or straight length is further required to be cleaned and capped prior to shipping. The maximum particulate residue limit for coils or straight lengths is 0.0035 g/ft2 or as listed in Table 2 and Table 3 of the standard. RJ Threadless Copper Pipe (TP): RJ Threadless copper pipe, often referred to as TP pipe, is a seamless copper pipe material manufactured to the requirements of ASTM B 302 Standard specification for Threadless Copper Pipe, Standard Sizes. This pipe may be manufactured from either of two alloys, C10300 or C12200 with C12200 being the most popular. Both of these alloys are composed of copper (Cu) concentrations in excess of 99.9% thereby making this material an almost pure copper product. Threadless copper pipe (TP) is manufactured in drawn temper (hard) only and is furnished in H58 temper in nominal or standard sizes through 12. The outside diameter of threadless copper pipe (TP) is essentially the same as schedule 40 pipe, although the wall thickness is much less than that for the same size pipe. The available lengths for Threadless copper pipe is 20 foot for sizes to 10 with 12 being furnished in 15 foot lengths. Types of Copper Tube Long lasting copper tube is a favourite choice for plumbing, heating, cooling and other systems. It is manufactured to meet the requirements of specifications established by the American Society for Testing and Materials (ASTM). All tube supplied to these ASTM standards is a minimum of 99.9 percent pure copper. The copper customarily used for tube supplied to these specifications is deoxidized with phosphorus and referred to as C12200 (Copper No. 122) or DHP1 Copper. Other coppers may also be used. Table 1 identifies the six standard types of copper tube and their most common applications.2 The table also shows the ASTM Standard appropriate to the use of each type along with a listing of its commercially available lengths, sizes and tempers.
11

Types K, L, M, DWV and Medical Gas tube are designated by ASTM standard sizes, with the actual outside diameter always 1/8-inch larger than the standard size designation. Each type represents a series of sizes with different wall thicknesses. Type K tube has thicker walls than Type L tube, and Type L walls are thicker than Type M, for any given diameter. All inside diameters depend on tube size and wall thickness. Copper tube for air-conditioning and refrigeration field service (ACR) is designated by actual outside diameter. "Temper" describes the strength and hardness of the tube. In the piping trades, drawn temper tube is often referred to as "hard" tube and annealed as "soft" tube. Tube in the hard temper condition is usually joined by soldering or brazing, using capillary fittings or by welding. Tube in the soft temper is commonly joined by the same techniques and also by the use of flaretype and compression fittings. It is also possible to expand the end of one tube so that it can be joined to another by soldering or brazing without a capillary fittinga procedure that can be efficient and economical in many installations. Tube in both the hard and soft tempers can also be joined by a variety of "mechanical" joints that can be assembled without the use of the heat source required for soldering and brazing.

ASTM A88, EN 1057,BS 2871-1,NZS3501 Seamless Copper Water Tube


Product Description: TYPE K
Nom. Size (") Dimensions (") Actual Outside Diameter Wall Thickness Calculated Values (Based on ASME B31) *Rated internal working pressures (psi) Nom. Weight Surface Temperature (lbs per Up to 150F 300F ft) Annealed Hard Annealed Hard Drawn Drawn 913 2029 842 1974 0.145 979 2135 902 2077 0.269 769 1683 709 1638 0.344 633 1389 583 1351 0.419 735 1609 662 1566 0.642 563 1236 520 1203 0.839 456 1003 420 976 1.037 424 933 391 908 1.362 372 820 343 798 2.065 341 751 314 731 2.928 330 579 304 560 4.005 313 549 288 531 5.124 308 540 283 522 6.516 295 517 272 500 9.678 296 520 272 502 13.878 315 554 290 535 25.930

1/4 3/8 1/2 5/8 3/4 1 1 1 2 2 3 3 4 5 6 8

.375 .500 .625 .750 .875 1.125 1.375 1.625 2.125 2.625 3.125 3.625 4.125 5.125 6.125 8.125

3/8 1/2 5/8 3/4 7/8 1 1/8 1 3/8 1 5/8 2 1/8 2 5/8 3 1/8 3 5/8 4 1/8 5 1/8 6 1/8 8 1/8

.035 .049 .049 .049 .065 .065 .065 .072 .083 .095 .109 .120 .134 .160 .192 .271

12

TYPE L
Nom. Size (") Dimensions (") Actual Outside Diameter Wall Thickness Calculated Values (Based on ASME B31) *Rated internal working pressures (psi) Nom. Weight Surface Temperature (lbs per Up to 150F 300F ft) Annealed Hard Annealed Hard Drawn Drawn 775 1722 714 1676 0.126 662 1471 610 1431 0.198 614 1362 565 1325 0.286 536 1192 494 1160 0.362 495 1099 456 1069 0.448 420 933 387 908 0.655 373 828 344 806 0.885 347 771 319 750 1.144 309 686 285 667 1.753 286 633 263 616 2.480 269 476 248 449 3.328 258 456 238 441 4.295 249 440 229 425 5.381 229 404 211 391 7.615 213 376 197 364 10.208 230 406 211 393 19.310 TYPE M Calculated Values (Based on ASME B31) *Rated internal working pressures (psi) Nom. Weight Surface Temperature (lbs per Up to 150F 300F ft) Annealed Hard Annealed Hard Drawn Drawn 485 1077 446 1048 0.144 420 932 387 907 0.204 346 769 319 748 0.328 286 636 264 619 0.465 287 638 265 621 0.682 281 625 259 608 0.940 254 563 234 548 1.460 233 517 215 503 2.027 215 380 198 367 2.678 214 378 197 366 3.582 313 377 197 365 4.664 198 349 182 337 6.661 185 328 171 317 8.922 195 344 179 333 16.475

1/4 3/8 1/2 5/8 3/4 1 1 1 2 2 3 3 4 5 6 8

.375 .500 .625 .750 .875 1.125 1.375 1.625 2.125 2.625 3.125 3.625 4.125 5.125 6.125 8.125

3/8 1/2 5/8 3/4 7/8 1 1/8 1 3/8 1 5/8 2 1/8 2 5/8 3 1/8 3 5/8 4 1/8 5 1/8 6 1/8 8 1/8

.030 .035 .040 .042 .045 .050 .055 .060 .070 .080 .090 .100 .110 .125 .140 .200

Nom. Size (")

Dimensions (") Actual Outside Diameter Wall Thickness

3/8 1/2 3/4 1 1 1 2 2 3 3 4 5 6 8

.500 .625 .875 1.125 1.375 1.625 2.125 2.625 3.125 3.625 4.125 5.125 6.125 8.125

1/2 5/8 7/8 1 1/8 1 3/8 1 5/8 2 1/8 2 5/8 3 1/8 3 5/8 4 1/8 5 1/8 6 1/8 8 1/8

.025 .028 .032 .035 .042 .049 .058 .065 .072 .083 .095 .109 .122 .170

* Annealed S = 5,100psi, Hard Drawn S = 11,300psi, for sizes " to 2" Nominal. S = 8,700psi for sizes over 2" Nominal, as these sizes are not normally available in the annealed form and are not therefore covered by ASME. The figures provided are for guidance only, based on the indicated temperatures.

13

Specifications: ASTM B88 STANDARD SPECIFICATION FOR SEAMLESS COPPER WATER TUBE: The B88 specification covers seamless copper water tube suitable for general plumbing, similar
applications for the conveyance of fluids, and commonly used with solder, flared, or compression-type fittings. The type of copper water tube suitable for any particular application is determined by the internal or external fluid pressure, by the installation and service conditions, and by local requirements. Means of joining or bending are also factors that affect the selection of the type of tube to be used. BS 2871 Part I: Copper Tubes for water, gas & sanitation BS EN 1057: Seamless, round copper tubes for water and gas in sanitary and heating applications NZS3501 Copper Tube & Coils for Water, Gas, Sanitation

Standard Met: Plumbing Tube TYPE K : Underground residential, commercial and industrial uses
Application: Water service, fire protection, solar, fuel oil Standard lengths & Tempers: 10' Hard, 20' Hard, 60' Soft, 100' Soft Color Code: Green Specifications: WWT-775-B / WWT-779-B / ASTM 8-88 / NSF 61

TYPE L : Residential and commercial uses


Application: Water service, fire protection, solar, fu el oil, natural gas Standard lengths & Tempers: 10' Hard, 20 ' Hard, 60' Soft, 100' Soft Color Code: Blue Specifications: WWT-775-B / WWT-779-B / ASTM B-88/ NSF 61

TYPE M : Above-ground residential and light commercial uses


Application: Water service, fire protection, solar, fuel oil Standard lengths & Tempers: 10' Hard, 20' Hard Color Code: Red Specifications: WWT-775-B / WWT-77 9-B / ASTM B-88 / NSF 61

ACR/OXY/MED : Types K and l, cleaned and capped


Application: Medical gas service, air conditio ning and refrigeration Standard lengths & Tempers: 10' Hard, 20' Hard Color Code: K- Green / L-Blue Specifications: ASTM B280 / ASTM B81 9

DWV : Application: Drainage


Standard lengths & Tempers: 10' Hard, 20' Hard Color Code: Yellow Specifications: ASTM 8306

Refrigeration Service Tube ACR/OXY - Type L: Cleaned and capped Application: Air conditioning and refrigeration service, medical gas Standard Lengths & Tempers: 10' Hard, 20' Hard Color Code: Blue Specifications: ASTM B280 I ASTM 881 9 Refrigeration : Above-ground residential and light commercial uses
Application: Air conditioning and refrigeration service Standard Lengths & Tempers: 50' Soft, 100" Soft Color Code: Red Specifications: ASTM B280 14

ASTM B359, ASTM B924 Fin Copper Tube


INNER GROOVED&OUTER GROOVED COPPER TUBE
We can supply products of all specifications according to requirement :

Inner Grooved Tube:


Internal OD Code RJ7002518 RJ7002715 RJ7942518 RJ7942815 RJ9522716 RJ9522815 RJ9523020 RJ12704025 RJ15885230 RJ7002515/18 RJ9523017/20
Material

Bottom Wall Thickness 0.25 0.27 0.25 0.28 0.27 0.28 0.30 0.40 0.52 0.25 0.30
C12200 Inner Tee Height 0.2 0.25 0.3 0.25 0.3 0.32 0.3-0.4 0.3-0.4 0.3-0.4 0.3-0.4 --------C4300 Wall thickness 0.4 0.45 0.48 0.5 0.75 0.5 -----

Height of Tee 0.18 0.15 0.18 0.15 0.16 0.15 0.20 0.20 0.30 0.15/0.18 0.17/0.20
C68700 Number of Tees 60 60 60 75 60 75 30-45 30-45 30-45 30-45 ---------

Spiral Angle 18 18 18 18 18 18 18 18 18 18(14) 18

Top Angle of Tee 40 53(43) 40 53 30 53 53 53 53 40 40

No. of Tee 50 60 56 60 70 60 60 70 74 64 74

7.00 7.00 7.94 7.94 9.52 9.52 9.52 12.7 15.88 7.00 9.52
C12000 ND

Outer Grooved Tube:


C70600 Unit weight(m/kg) 0.125 0.135 0.19 0.21 0.28 0.265 ----0.8-0.9 0.8-0.9 0.65 0.65 1.0-1.45 --30-52 30-52 30-52 30-52 19/26/33 --15-16 5-12 0.30.5 1-2 Out fin height Number of fin Pitch Depth

Inner grooved tube length with bare ends

9.52 12.7 15.88

Size

Tube for Condenser Tube for Evaporator Low finned tubes Corrugated Tube Spiral Tube

16 19 16 19 16 19 16-25

standard

9.5222 ASME SB75/SB359 ASME SB111/SB359 ASME SB75/SB359

Specifications: ASME SB75/SB359 ASME SB111/SB359/ASTM B359 / B359M - 02(2006) Standard Specification for Copper and Copper-Alloy Seamless Condenser and Heat Exchanger Tubes With Integral Fins: This specification establishes the requirements for
seamless copper and copper alloy tubing on which the external or internal surface, or both, has been modified by a cold forming process to produce an integral enhanced surface for improved heat transfer. The tubes are typically used in surface condensers, evaporators, and heat exchangers. The seamless copper and copper alloy tubing shall have the internal or external surface, or both, modified 15

by a cold forming process to produce an integral enhanced surface for improved heat transfer. The tube, after enhancing, shall be supplied in the annealed (O61) or as-fabricated temper. The enhanced sections of tubes in the as-fabricated temper are in the cold-worked condition produced by the fabricating operation. The unenhanced sections of tubes in the as fabricated temper are in the temper of the tube prior to enhancing, annealed (O61), or light drawn (H55), and suitable for rolling-in operations. Samples of annealed-temper (O61) tubes selected for test shall be subjected to microscopical examination and shall show uniform and complete recrystallation. Grain size and mechanical properties such as tensile strength and yield strength of the alloys shall be determined. Expansion and flattening tests shall be done to the alloys for performance evaluation. Non-destructive tests such as eddy-current test, hydrostatic test, and pneumatic test shall be done as well 1. Scope 1.1 This specification establishes the requirements for seamless copper and copper alloy tubing on which the external or internal surface, or both, has been modified by a cold-forming process to produce an integral enhanced surface for improved heat transfer. 1.2 UnitsThe values stated in either in-pound units or SI units are to be regarded separately as the standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems could result in non-conformance with the specification. 1.3 The tubes are typically used in surface condensers, evaporators, and heat exchangers. 1.4 The product shall be produced of the following coppers or copper alloys, as specified in the ordering information. Copper or Copper Alloy UNS No. Type of Metal
C10100 Oxygen-free electronic C10200 Oxygen-free without residual deoxidants C10300 Oxygen-free, extra low phosphorus C10800 Oxygen-free, low phosphorus C12000 DLP Phosphorized, low residual phosphorus (See Note 1) C12200 DHP, Phosphorized, high residual phosphorus (See Note 1) C14200 DPA Phosphorized arsenical (See Note 1) C19200 Phosphorized, 1 % iron C23000 Red Brass C44300 Admiralty Metal Types B, C44400 C, and C44550 D C60800 Aluminum Bronze C68700 Aluminum Brass Type B C70400 95-5 Copper-Nickel C70600 90-10 Copper-Nickel C70620 90-10 Copper-Nickel (Modified for Welding) C71000 80-20 Copper-Nickel Type A C71500 70-30 Copper-Nickel C71520 70-30 Copper-Nickel (Modified for Welding) C72200 Copper-Nickel Note 1Designations listed in Classification B 224.

1.5 The following safety hazard caveat pertains only to the test methods described in this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.6 Product produced in accordance with the Supplementary Requirements section for military applications shall be produced only to the inch-pound system of this specification. 16

ASTM B88,ASTM B111-70/30,90/10 Copper Nickel Tube


Specifications: ASTM B1-01(2007) Standard Specification for Hard-Drawn Copper Wire ASTM B2-00(2005)e1 Standard Specification for Medium-Hard-Drawn Copper Wire ASTM B3-01(2007) Standard Specification for Soft or Annealed Copper Wire ASTM B5-00(2005) Standard Specification for High Conductivity Tough-Pitch Copper Refinery Shapes ASTM B6-07 Standard Specification for Zinc ASTM B8-04 Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft ASTM B9-90(2003) Standard Specification for Bronze Trolley Wire ASTM B16/B16M-05 Standard Specification for Free-Cutting Brass Rod, Bar and Shapes for Use in Screw Machines Standards Met: Application : Widely applicable for the condenser tubes to the electric power, the shipbuilding, the salty chemical industry, the central air conditioning, the water treatment and so on. The Copper Alloy Tube has the good corrosion resistance ability and the high intensity, widely applied to the industry of the tubular electricity-generating heat exchanger, the ship condenser, the water-supplying heater, the distiller, the oil cooler and the warter- treating heat exchanger and so on. 1) Cast Bronze Flared Tube Fittings to ANSI B18.26 2) Streamline Copper Tube TYPES K, L & M to ANSI H23.1, ASTM B88 and WWT-799 for Refrigeration 3) Streamline Copper Refrigeration Service Tube to ANSI H23.5, ASTM B280, and WWT- 775 4) Streamline Nitrogenized ACR Hard Drawn Copper Tube to ANSI H23.1 Type L and ASTM B88 Type L, in accordance with ASTM 8280 5) Oxygen Service Tube to ANSI H23. 1 Types K and L and ASTM B88, Types K and L hard drawn lengths only in accordance to CDA cleanliness specifications and NFPA 56F, Seamless Copper Tube cleaned for Oxygen Gas Service 6) Streamline Copper Tube TYPE DWV to ANSI H23.6 and ASTM B306 7) Copper Pipe to ASTM B42 8) Red Brass Pipe to ASTM B43

Tubular Wrought Copper:


ASTM B75 Alloy C12200 Standard Specification for Seamless Copper Tube or Products Made From Sheet ASTM B-42 Seamless copper pipe in all standard pipe sizes, both regular and extra-strong, suitable for use in plumbing, boiler feed lines, and for similar purposes ASTM B-43 Seamless red brass (Copper Alloy UNS No. C23000) pipe in all standard pipe sizes, both regular and extra-strong, suitable for use in plumbing, boiler feed lines, and for similar purposes ASTM B-68 Annealed seamless copper tube suitable for use in refrigerators, oil lines, gasoline lines, etc., where tube absolutely free from scale end dirt is required. ASTM B-75 Seamless copper, round and rectangular including square tube suitable for general engineering purposes. ASTM B-88 Seamless copper water tube suitable for general plumbing, and similar applications for the conveyance of fluids, and commonly used with solder, flared, or compression type fittings. 17

ASTM B-111 Seamless tube and ferrule stock of copper and various copper alloys up to 2 in. (50.8mm), inc., in diameter, for use in surface condensers, evaporators, and heat exchangers. ASTM B-135 Seamless round and rectangular including square copper alloy tube in straight lengths. ASTM B-280 Seamless copper tube for air conditioning and refrigeration service and intended for use in the field for connection, repairs, and alterations. ASTM B-302 Threadless, seamless, deoxidized copper pipe (TP) in straight lengths, for piping systems that are assembled with brazed-joint pipe fittings. ASTM B-306 Seamless copper drainage tube (DWV) intended for use with soldered fittings for sanitary drainage, such as soil, waste, and vent piping.

Nonferrous Fittings:
Cast Pressure Solder Joint Fittings to ANSI B16.18 Cast Bronze Flared Tube Fittings to ANSI B18.26 Flare Type Fittings to ANSI B70.1 and SAE J513 WROT DWV Solder Joint Fittings to ANSI B16.29 Cast DWV Solder Joint Fittings to ANSI B16.23

Fittings to meet the following specifications::


MSS SP1O4 - Wrought Copper LW Solder, Joint Pressure Fittings ANSI B16.29-1990 - Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings DWV ANSI B16.18-1984 - Cast Copper Alloy Solder Joint Pressure Fittings ANSI B16.15-1978 - Cast Bronze Threaded Fittings ANSI B16.26-1983 - Cast Copper Alloy Fittings for Flared Copper Tube ANSI B16.23-1984 - Cast Copper Alloy Solder Joint Drainage Fittings - DWV ANSI B16.24-1 979 - Bronze Pipe Ranges and Flanged Fittings Fitting to comply with the material, performance and installation/joining dimensions of ANSI B16.22 and following specifications ASTM B152 Alloy C11000 Standard Specification for Copper Sheet Strip, Plate and Rolled Bar, ASTM B584 Alloy C84400 Standard Specification for Copper Alloy Sand Castings for General Applications, Federal Specification WW-U-516 for Type Ill, Class A and Class B Copper Alloy Unions. Other applicable standards for nonferrous tubes and fittings: Inner grooved copper tube to ASTM B 68, EN 12735, JIS H3300 standards Pancake coiled copper tube ASTM B 280, EN 12735, JIS H3300 Straight copper tube to ASTM B 280, C 121000, C12200, EN 12735, JIS H3300 C1220. M 741121 Brass Tube & Pipe - ASTM B 111 C26000, C27000, C28000, or BS 2871 or JIS H3300 Admiralty Brass Tube -C44300, C44400, C44500 Aluminum brass tube - ASTM B 111 C68700, BS 2871 CZ111or JIS H3300 C6870 standard Copper-Nickel Tube & Pipe - ASTM B 111 C70600,C71500,C71640 BS 2871 or JIS H3300 Inner grooved copper tube to ASTM B 68, EN 12735, JIS H3300 standards Water copper tube ASTM B 88, EN 1057, BS 2871, JIS H3300 Water copper tube ASTM B 88, EN 1057, BS 2871, JIS H3300 18

Pancake Coils Copper Tube-ASTM B68,ASTM B75,BS 2871,DIN1787,EN1057


Product Description: Comparison table of chemical composition & mechanical Properties of the product as per standards Standard Copper Alloy NO. Chemical Composition CU% P% Mechanical Properties Temper Tensile strength (Mpa) 60 205 50 245 Elongation (%) 40 Average Grain Size (mm) >0.040 0.015 ~ 0.040

ASTM B68

C12200

99.9

0.015 to 0.040

Outside Diameter (mm) Average Diameter 3.184.76 >4.7610.0 >10.0~12.0 >12.0~12.7 >12.7~14.0 >14.016.0 >16.018.0 >18.020.0 >2022.22 >22.2228.4 Standard

Wall Thickness (mm) 0.25 0.35 0.235 0.5 0.5 0.7 0.7 1.0 ASTM 1.0 1.2 1.2 1.5 EN 1.5 2.0

GB

JIS

Standards Phosphorus deoxidized copper (DLP) Phosphorus deoxidized copper (DHP) Tough Pitch Copper (ETP)

standar d symbol standar d symbol standar d symbol

ASTM B 75 C 12000 ASTM B-68 C -12200 C 11000

BS 2871 C106 BS 2871 C 106 BS 2871 C 101

JIS H 3300 C 1201 JIS H 3300 C 1220 JIS H 3300 C 1100

DIN 1787 SW-CU DIN 1785 SF-CU DIN 1787 ECU 58


19

Application: Mainly applied to the Air Conditioning Unit's connecting tube etc. The Pancake Coil Copper Tube (PCC) not only has the merit of plain tube, furthermore it is convenient for packing and Transportation .This product is mainly applied to the Air Conditioning Unit's connecting tubes and so on. To meet the precise demands of clients, we manufacture, supply and export a qualitative range of Copper. Standards Met: To meet the precise demands of clients, we manufacture, supply and export a qualitative range of Copper Tube Coils. These coils are available in different qualities, plain and plastic coated copper coils, single/double layer, soft annealed or other specifications as per the exact industrial requirements. Our coils are manufactured using best quality raw components sourced from certified vendors of industry. We strictly follow international standards to manufacture our products and ensure durability and reliability of our products. Owing to application specific designs our coils are widely used in various industries. The hardness range of our coils is approximately 45/60 HV5, outside diameter tolerance of +0.0/-0.08mm (0.003"), and an annealed at approximately 600C to ensure maximum efficiency. Our coils are acknowledged for their dry and clean external and internal surfaces and brightness. Precise dimensions of our coils ensure optimum functionality, long functional life and consistent performance. Cost effective range of our products are extensively acclaimed owing to sturdiness and high performance. we are step ahead of our competitors in manufacturing and supplying a wide range of plastic coated copper coils and copper alloy coils in different color coded specifications and dimensions. Besides, we quality check these on prescribed parameters before delivery to offer defect free range at our clients end. Demands of these products are increasing day by day owing to long functional life and reliability.

20

ASTM B280,EN 12735-1,AS/NZS 1571 ACR Copper Tube


Product Description: Seamless copper tube according ASTM B 280 Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service - is intended for use in the connection, repairs, or alternations of air conditioning or refrigeration units in the field. AC/R Copper Tubes is used in the Air Conditioning and Refrigeration Field Service Industry and is designated by the tube's actual OD. B 280 tube is produced in straight lengths or coils.

STRAIGHT LENGTHS Standa Outside Dia. rd in. (mm) Size, in. 3/8 0.375 (9.52) 1/2 0.500 (12.7) 5/8 0.625 (15.9) 3/4 0.750 (19.1) 7/8 0.875 (22.2) 1 1/8 1.125 (28.6) 1 3/8 1.375 (34.9) 1 5/8 1.625 (41.3) 2 1/8 2.125 (54.0) 2 5/8 2.625 (66.7) 3 1/8 3.125 (79.4) 3 5/8 3.625 (92.1) 4 1/8 4.125 (104.8)

Wall Thickness in. (mm) 0.030 (0.76) 0.035 (0.89) 0.040 (1.02) 0.042 (1.07) 0.045 (1.14) 0.050 (1.27) 0.055 (1.40) 0.060 (1.52) 0.070 (1.78) 0.080 (2.03) 0.090 (2.29) 0.100 (2.54) 0.110 (2.79)

Weight, lb/ft (kg/m) 0.126 (0.187) 0.198 (0.295) 0.285 (0.424) 0.362 (0.539) 0.455 (0.677) 0.655 (0.975) 0.884 (1.317) 1.14 (1.703) 1.75 (2.609) 2.48 (3.692) 3.33 (4.954) 4.29 (6.393) 5.38 (8.010)

Nom. Weight, kgs 5.8 metres 1.09 1.71 2.46 3.13 3.92 5.65 7.65 9.85 15.13 21.42 28.73 37.08 46.45

* Safe Working internal pressures PSI (KPa) 150F 810 (5585) 675 (4654) 625 (4310) 545 (3758) 495 (3415) 440 (3035) 385 (2655) 355 (2450) 315 (2170) 295 (2035) 275 (1895) 270 (1860) 255 (1760)

21

ANNEALED COIL Standa Outside Dia. Wall Weight, lb/ft Nom. * Safe Working rd in. (mm) Thickness (kg/m) Weight, internal Size, in. (mm) kgs 15 pressures in. metres PSI (KPa) 150F 3/16 0.187 (4.76) 0.030 (0.76) 0.0575 (0.086) 1.28 1690 (11650) 1/4 0.250 (6.35) 0.030 (0.76) 0.0804 (0.120) 1.80 1230 (8480) 5/16 0.312 (7.92) 0.032 (0.81) 0.109 (0.162) 2.43 1040 (7170) 3/8 0.375 (9.52) 0.032 (0.81) 0.134 (0.199) 2.98 860 (5930) 1/2 0.500 (12.7) 0.032 (0.81) 0.182 (0.271) 4.07 630 (4344) 5/8 0.625 (15.9) 0.035 (0.89) 0.251 (0.373) 5.62 540 (3723) 3/4 0.750 (19.1) 0.035 (0.89) 0.305 (0.454) 6.81 440 (3034) 3/4 0.750 (19.1) 0.042 (1.07) 0.362 (0.539) 8.09 535 (3690) 7/8 0.875 (22.2) 0.045 (1.14) 0.455 (0.677) 10.16 500 (3450) 1 1/8 1.125 (28.6) 0.050 (1.27) 0.665 (0.975) 14.62 430 (2965) 1 3/8 1.375 (34.9) 0.055 (1.40) 0.884 (1.317) 19.75 390 (2690) * Computed allowable stress for annealed copper tubes at the indicated temperature as determined from ASME B31.

Chemical Composition & Mechanical Properties


Standard Copper Alloy No. C11000 C12200 C1100 Chemical Composition CU% p% 99.9 99.9 99.9 0.015~0.04 0 0.015~0.04 0 0.015~0.04 0 Mechanical Properties Temper Tensile strength (Mpa) 205 205 205 245~325 275 205 205 245~325 Elonga tion 40 40 40 40 Grain Size (mm) 0.035 0.025~0.060 0.04

ASTM B280 JIS H3300

1/2H H L 1/2H

C1220

99.9

Specification: ASTM B 280 Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service BS 2871- 2 / BS EN 127351- Copper Air-conditioning & Refrigeration Tubes & Fittings Suitable for high pressure-refrigerants such as R410A AS/NZS 1571 Copper Seamless Tube for Air-Condition and Refrigeration

22

LWC for ACR Level Wound Coils -ASTM B-280, EN-12735, JISH-3300, GB/T-177
Product Description

Outside Diameter(mm) Average Diameter 4.0 >4.05.0 >5.06.0 >6.010.0 >10.012.7 >12.714.0 >14.019.05 >19.0525.40 Standard

Wall Thickness (mm) 0.25 0.25 0.40 0.40 0.60 EN 0.60 0.8 0.80 1.2 1.22.0

GB

ASTM

JIS

Application : Applied to the Air Conditioner, the Assembly Type Air Conditioning Unit Refrigerator Freezer Chest etc. The High Precise Plain Copper Tube(LWC) has the excellent characteristics such as the high clean and ultra luminous surface in both inside and outside , the even and compact structure , the high precise dimension, the high heat exchange efficiency, and the easy weld, the permanent anti-corrosive capability, the good formability and so on, the main technical parameter conforms to the request of the standards JIS H3300 and ASTM B280 , it is widely applied to the Air Conditioning & Refrigeration as well as the Heat Exchanger field.

Specifications: KS D5301 / JIS H 3300 / ASTM B 280, B68, B75 / AS/NZS 1571 / BS 2871

23

ASTM B111, ASTM B837,ASTM B903 Copper Heat Exchanger Tube


Product Description COPPER AND ALLOY TUBE
O.D.(mm) 8-50 Material Alloy ASTM B111/111M Copper Tube C11000 C12000 C12200 C44300 Aluminum Brass T ube CopperNickel Tube C68700 C70600 C71500 C6870 C7060 C7150 CZ110 CN102 CN107 CuZn20Al2 CuNi10Fe1 Mn CuNi30Mn 1Fe JIS H3300:1997 C1100 C1201 C1220 BSI C101,C102 C106 ISO Cu-ETP Cu-DLP Cu-DHP HSn70-1 HAi77-2 BF210-1-1 BFe30-1-1 GB/T8890-1998 Thickness(mm) 0.8-2.5 Length 40M

Ally No. C44300 C68700 C70600 C71500 C71640

ASTM B111M Tube Temper 61 H50 H55 H80 HE80 Annealed Drawn and Stressrelieved Light Drawn Hard Drawn Hard Drawn & End Annealed Finned Dimensions F Pl Fin OD (mm) Fin Height (mm)

AS 1569 Tube Temper 0 H Temper Tubes in the fully softened condition(annealed) Tubes in the as-drawn and stress-relieved condition

1/4 H

Tubes heat treated or work hardened to provide a fine-grained structure with an intermediate hardness

Alloy

Plain Dimen sions Out Wal side l Dia Thic mete knes r s (mm) (mm)

Not ch of Fin

Nomi nal O utside Surfac e Area (/m) 0.050 0.050 0.050 0.060 0.060 0.060 0.060 0.060 0.060 0.044

Actua l Outsid e Surf ace Ar ea( /m) 0.203 0.211 0.195 0.272 0.272 0.288 0.391 0.263 0.253 0.191

Wal l Und er Fins (mm)

Rid ge Num ber (n)

Ridge Heigh t (mm)

Nomi nal O utside Surfac e Are a ( /m) 0.040 0.040 0.041 0.050 0.049 0.050 0.069 0.049 0.050 0.030

Actua l Outsid e Surf ace Ar ea( /m) 0.040 0.048 0.048 0.084 0.084 0.084 0.118 0.049 0.060 0.030

T2/TP 2

BFe10-1-1 HSn70-1 HAl77-2

16 16 15.88 19 19 19 25.25 18.85 18.85 13.85

1.10 1.20 1.00 1.13 1.20 1.13 1.18 1.20 1.20 1.50

42 42 46 46 46 50 50 46 46 42

15.85 15.85 15.80 18.85 18.85 18.85 25.25 18.85 18.85 13.85

0.90 0.90 0.75 0.95 0.95 0.92 0.92 0.90 0.85 1.0

0.65 0.63 0.60 0.63 0.65 0.63 0.71 0.71 0.71 1.1

-30 20 45 45 45 54 -3.3 --

-0.30 0.35 0.38 0.38 0.38 0.40 -0.25 --

24

Specification: ASTM B903 - 10 Standard Specification for Seamless Copper Heat Exchanger Tubes With Internal Enhancement : This specification covers seamless, internally enhanced copper
tube, in straight lengths or coils, suitable for use in refrigeration and air-conditioning products or other heat exchangers. The material of manufacture shall be cast billet, bar, tube, or so forth of copper UNS No. C12200 and shall be of such purity and soundness as to be suitable for processing into the tubular product described. The tube shall be manufactured by such hot- and cold-working processes needed to produce a homogenous, uniform wrought structure in the finished product. The material shall conform to the chemical composition requirements specified. The grain size shall be determined in the wall beneath the ridges. The microstructure shall show complete recrystallization and shall have an average grain size within the limits specified. As-fabricated and O (annealed) temper tube shall conform to the mechanical properties specified. The specimens of annealed product shall withstand the specified expansion tested as specified. Each tube shall be subjected to an eddy-current test. Tubes shall be tested normally in the fabricated temper; however, they may be tested in the annealed temper at the option of the manufacturer. This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. 1. Scope 1.1 This specification establishes the requirements for seamless, internally enhanced copper tube, in straight lengths or coils, suitable for use in refrigeration and air-conditioning products or other heat exchangers. 1.2 UnitsThe values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.2 1.3 Tubes for this application are manufactured from the following copper: 1.3

Copper UNS No. Type of Metal C12200 Phosphorized, high residual phosphorus (DHP)

Application : Widely applicable for the condenser tubes to the electric power, the shipbuilding, the salty chemical industry, the central air conditioning, the water treatment and so on. The Copper Alloy Tube has the good corrosion resistance ability and the high intensity, widely applied to the industry of the tubular electricity-generating heat exchanger, the ship condenser, the water-supplying heater, the distiller, the oil cooler and the water- treating heat exchanger and so on. ASTM B837-2010 Standard Specification for Seamless Copper Tube for Natural Gas and Liquefied Petroleum (LP) Gas Fuel Distribution Systems 1.1 This specification establishes the requirements for Type GAS seamless Copper UNS No. C12200 tube for use in above ground natural gas and liquified petroleum (LP) gas fuel distribution systems, commonly assembled with flared fittings or brazed joints. 1.2 O60 (soft annealed) temper gas tube is produced in the range of standard sizes 3/8 to 11/8in. outside diameter; H58 (drawn general purpose) temper gas tube is produced in the range of standard sizes 3/8 to 11/8in. outside diameter. Note 1Tube temper, size and joining method are determined by installation code requirements. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 25

ASTM B280, ASTM B68, EN12735, AS1571 LWC FOR ACR SERIES (INNER GROOVED)
Product Description LWC FOR ACR SERIES (INNER GROOVED)
1. Application: The even and compact structure, the highly precise dimension, the normative and integrity groove shape, the low interior surface residuum etc, the inside surface area increases 65-100% than that of the same specification of plain copper tube, the heat transfer coefficient is about 1.8-2.0 times of that of same specification of plain tube, inner grooved copper tube is widely applied to the Air Conditioner, the Assembly Type Air Conditioning Unit, the Residential Certral Air Conditioning, Show Case Refrigerator which is in conformance with the developing tendency of the Air Conditioner and Refrigerator to the high efficiency, the energy saving. 2. Standard: ASTM B280, ASTM B68, EN12735, AS1571 3. Temper: O60 4. Package: Packed individually by reel, 6-7 coils packed by one pallet
Specification unit weight (kg) 5.00x0.20+0.15-18 7.00x0.25+0.10-15 7.00x0.25+0.18-18 7.00x0.25+0.22-16 7.00x0.27+0.15-18 7.94x0.25+0.18-18 7.94x0.25+0.18-18 7.94x0.26+0.17-18 7.94x0.28+0.20-18 7.94x0.30+0.20-18 9.52x0.27+0.16-18 9.52x0.28+0.12-15 9.52x0.28+0.15-18 9.52x0.28+0.15-25 9.52x0.28+0.20-18 9.52x0.28+0.20-18 9.52x0.28+0.20-18 9.52x0.30+0.20-18 9.52x0.34+0.15-25 9.52x0.40+0.25-18 12.00x0.36+0.25-18 12.70x0.35+0.25-18 12.70x0.40+0.25-18 12.70x0.50+0.25-18 12.75x0.36+0.21/0.25-208 33 52 57 58 60 65 66 66 72 76 82 80 83 88 85 88 90 94 104 123 140 155 170 201 150 O. D (mm ) 5 7 7 7 7 7.94 7.94 7.94 7.94 7.94 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 12 12.7 12.7 12.7 12.75 I. D (mm ) 4.3 6.3 6.14 6.06 6.16 7.08 7.04 7.08 6.98 6.94 8.66 8.72 8.66 8.66 8.56 8.56 8.52 8.52 8.54 8.22 10.78 11.5 11.4 11.2 11.53 Bottom Wall Thickness(m m) 0.2 0.25 0.25 0.25 0.27 0.25 0.25 0.26 0.28 0.3 0.27 0.28 0.28 0.28 0.28 0.28 0.28 0.3 0.34 0.4 0.36 0.35 0.4 0.5 0.36 Fin Groove Depth(m m) 0.15 0.1 0.18 0.22 0.15 0.18 0.2 0.17 0.2 0.2 0.16 0.12 0.15 0.15 0.2 0.2 0.2 0.2 0.15 0.25 0.25 0.25 0.25 0.25 0.25 Total Wall Thickness(m m) 0.35 0.35 0.43 0.47 0.42 0.43 0.45 0.43 0.48 0.5 0.43 0.4 0.43 0.43 0.48 0.48 0.5 0.5 0.49 0.65 0.61 0.6 0.65 0.75 0.61 Ape x Angl e 40 40 40 22 53 40 40 40 40 40 30 53 53 90 25 40 30 53 90 40 40 53 53 53 48 Heli x Angl e 18 15 18 16 18 18 18 18 18 18 18 15 18 25 18 18 18 18 25 18 18 18 18 18 20 Number of Tooth

40 65 60 50 54 60 50 50 50 50 70 65 60 65 55 60 60 60 65 60 70 70 70 75 70

26

ASTM B360 Copper Capillary Tube


Product Description: 1.Chemical compositionC10800 Cu+Ag99.5% P=0.005-0.012% C12000 Cu+Ag99.90% P=0.004-0.012% C12000 Cu+Ag99.90% P=0.015-0.040% 2.tensile strength390Mpa 3.delivery temperhard drawn H80 4.cleanness of interior surface 0.310g/ 5.size tolerance OD 0.051mm ID 0.025mm I D in 0.072 0.081 0.087 0.093 0.097 0.099 0.106 0.112 0.125 0.145 0.145 0.160 0.160 0.188 0.200 0.220 0.240 mm 1.83 2.06 2.21 2.36 2.46 2.51 2.70 2.84 3.18 3.68 3.68 4.06 4.06 4.8 5.08 5.60 6.10 I D in 0.026 0.031 0.036 0.042 0.046 0.049 0.054 0.059 0.064 0.080 0.090 0.100 0.110 0.120 0.145 0.160 0.175 mm 0.660 0.787 0.914 1.067 1.168 1.245 1.372 1.498 1.625 2.032 2.286 2.540 2.794 3.050 3.680 4.060 4.445 mean WT in 0.023 0.025 0.0255 0.0255 0.025 0.025 0.026 0.0265 0.0305 0.0325 0.0275 0.030 0.025 0.034 0.0275 0.030 0.0325 mm 0.580 0.635 0.648 0.648 0.635 0.635 0.660 0.670 0.770 0.830 0.698 0.762 0.635 0.864 0.698 0.762 0.830 bore cross section in2 0.0005309 0.0007548 0.001018 0.001385 0.001662 0.001886 0.002290 0.002734 0.003217 0.005027 0.006362 0.007854 0.009503 0.01131 0.0165 0.02011 0.02405 mm2 0.4356 0.6194 0.8354 0.8937 1.071 1.217 1.477 1.7615 2.073 3.241 4.102 5.064 6.128 7.302 10.630 12.940 15.51 Weight Kg/m 0.0204 0.0254 0.0284 0.0387 0.0325 0.0334 0.0378 0.0408 0.0521 0.0664 0.0585 0.0706 0.0611 0.0955 0.0859 0.1035 0.1228 Residue Limit g/m2 0.000656 0.000754 0.000886 0.00105 0.00115 0.00121 0.00134 0.00144 0.00157 0.00197 0.00223 0.00246 0.00272 0.00295 0.00358 0.00397 0.00433

Application : Applicable for the Refrigerator, the Air Conditioner, the Heat Exchanger, the Instrument, the Filter, the Accumulator Tank ,Y Type Connecting /Tubing Part and so on. Specifications: ASTM B360 - 09 Standard Specification for Hard-Drawn Copper Capillary Tube for Restrictor Applications made from Copper Alloy UNS Nos. C10800, C12000, or C12200. Standards Met: ASTM B251 / EN12449 / BS2871-2
27

ANSI/ASME B16.22,EN1254-1,BS 864-2,DIN2856,JIS H3401 Copper Fittings


2215, 2815, 28X22, 3515, 3522, 3528, 4222, 4228, 4235, 5428, 5435, 5442, 6735, 6742, 6754, 7642, 7654, 7667, 10854, 10867, 10876, 13367, 13376, 133108, 15976, 159108, 159133, 219108, 219133,219159 22 X 15,2815,2822, 3515,3522,3528, 4515,4222,4228, 4235,5415,5428, 5435,54X42,6735, 6742,6754,7642, 7654,7667,10854, 10867, 10876

ht Coupling

15, 22, 28, 35, 42, 54, 67,76,108, 133,159,219, 273, 325

Reducing Coupling

Fitting Reduced

90 Elbow

15, 22, 28, 35, 42, 54, 67, 76, 108, 133,159,219, 273, 325

90 Reduced Elbow

2215, 2815, 2822

45 Elbow

15,22,28,35,42, 54,67,76,108, 133,159,219

Equal Tee

15, 22, 28, 35, 42 , 54, 67, 76, 108, 133,159,219

Reducing Tee

221522,281528,282228, 352835,352235,352835, 422242,422842,423542, 542854,543554,544254, 673567,674267,675467, 764276,765476,766776, 10854108, 10867108, 10876108, 13367133, 13376133, 133108133, 15976159, 159108159, 159133159,219159219

Reducing Tee Both Ends

152215, 222822,283528

Reducing Tee one end & Branch

Cross

221515, 282222, 282215, 281522, 282822, 353522 22, 28, 35, 42, 54, 67, 76, 108 15, 22, 28 15, 22, 28, 35, 42

Cap

15, 22, 28, 35, 42, 54, 67, 76, 108, 133, 159, 219,

180 UBend

15, 22, 28, 35, 42, 54, 67, 76, 108, 133, 159, 219,

Cross Reduced Half Cross Over

5442, 6735, 6742, 6754

P-trap Tube Strap

15,22,28

Cross Over Flush Bushing

15, 22, 28

15,22,28

Specifications: Cast Bronze Threaded Fittings: Classes 125 and 250 Cast bronze threaded fittings in class 125 and class 250 shall be manufactured to the requirements of ANSI/ASME B16.15 Cast Bronze Threaded Fittings. These fittings shall be produced to meet the general requirements of ASTM B 62, Alloy C83600 or the chemical and tensile requirements of ASTM B 584, alloys C83800 or C84400. Other alloys permitted for use to manufacture fittings from bar stock in smaller sizes for wrought plugs, caps, couplings and bushings shall meet the requirements of Alloy C36000 (Free Cutting Brass Rod, Bar and Shapes) or C32000 or C31400 (Leaded Brass). Essentially, the elemental make-up of these cast brass fittings is approximately but not exactly equal to 85% Copper (Cu), 5% Tin (Sn), 5% Lead (Pb) and 5% Zinc (Zn) These fittings shall be threaded in accordance with the requirements of ANSI/ASME B1.20.1 general-purpose pipe threads and the threads shall be tapered. Wrought couplings, caps, and
28

bushings in nominal pipe sizes of 1/8, , 3/8, and may have straight internal threads. Class 125 fittings shall be identified with the manufacturers name or trademark and Class 250 fittings shall be marked with the manufacturers name or trademark and the nu mbers 250. The requirement for marking may be omitted from fittings that are deemed too small to provide adequate surface area for marking. Cast Copper Solder Joint Fittings PRESSURE APPLICATIONS Cast copper alloy fittings used in solder joint applications are to be manufactured to meet the requirements of ANSI/ASME B16.18 Cast Copper Alloy Solder Joint Pressure Fittings. These fittings shall be produced to meet the general requirements of ASTM B 62, Alloy C83600 or the chemical and tensile requirements of ASTM B 584, alloys C83800 or C84400. Essentially, the elemental make-up of these cast brass fittings is approximately but not exactly equal to 85% Copper (Cu), 5% Tin (Sn), 5% Lead (Pb) and 5% Zinc (Zn). These fittings (socket end diameter) are sized in accordance with the requirements of the ASTM B88 Seamless Copper Water Tube (1/4 12 nominal diameters), while the sizes of any threaded connections (female or male) correspond to nominal pipe sizing. Marking of these fittings shall be in accordance with MSS SP-25. They shall bear a permanent mark indicative of the manufacturers name or trademark; although fittings in sizes less than may have this requirement omitted. The actual burst strength of the fitting shall not be less than the burst strength, as computed, for type L seamless copper water tube of annealed temper. Wrought Copper Solder Joint Fittings PRESSURE APPLICATIONS Wrought (Wrot) copper fittings used for pressure applications shall be manufactured to meet the requirements of ANSI/ASME B16.22 Wrought Copper & Copper Alloy Solder Joint Pressure Fittings. These fittings may be manufactured from any one of the following alloys: C10200, C12000, C12200, or C23000 or any copper alloy that contains at least 84% Copper (Cu) and a maximum of 16% Zinc (Zn). These fittings (socket end diameter) are sized in accordance with the requirements of the ASTM B88 Seamless Copper Water Tube (1/4 12 nominal diameters), while the sizes of any threaded connections (female or male) correspond to nominal pipe sizing and the requirements of ANSI/ASME B1.20.1. These fittings shall have a burst pressure approximately equal to four (4) times the rated internal working pressure of type L seamless copper water tube in annealed temper. Marking of these fittings shall be in accordance with MSS SP-25. They shall bear a permanent mark indicative of the manufacturers name or trademark; however, marking may be omitted from any fitting if it could damage the soldering surfaces.

29

Cast Copper Solder Joint Drainage Fittings DRAIN, WASTE AND VENT APPLICATIONS Cast copper alloy fittings used for drainage, waste , and vent applications with solder joints are manufactured to the requirements of ANSI/ASME B16.23 Cast Copper Alloy Solder Joint Drainage Fittings DWV. These fittings shall be produced to meet the general requirements of ASTM B 62, Alloy C83600 or the chemical and tensile requirements of ASTM B 584, alloys C83800 or C84400. Essentially, the elemental make-up of these cast brass fittings is approximately but not exactly equal to 85% Copper (Cu), 5% Tin (Sn), 5% Lead (Pb) and 5% Zinc (Zn). These fittings (socket end diameter) are sized in accordance with the requirements of the ASTM B306 Copper Drainage Tube (1 8 nominal), while the size of any threaded connections (female or male) correspond to nominal pipe sizing (slip-joints are excepted). Drainage fittings are required to be identified (marked) with a permanent mark containing the manufacturers name or trademark and DWV. Vent fittings shall be identified with the words VENT ONLY and have the manufacturers name or trademark permanently marked in accordance with MSS SP-25. All 90??fittings shall be pitched so that a slope of 0.25 in./ft. (2.1%) is developed in horizontal tube as referenced along a horizontal plane. Cast Copper Flanges and Flanged Fittings CLASS 150, 300, 400, 600, 900, 1500 AND 2500 Cast copper alloy flanges or flanged fittings shall be manufactured to the requirements of ANSI/ASME B16.24 Cast Copper Alloy Pipe Flanges, Flanged Fittings, Class 150, 300, 400, 600, 900, 1500 and 2500. Cast copper alloy flanges may be manufactured from alloy C83600 a leaded red brass alloy, C922200 a leaded tin bronze alloy, or C95200 an aluminum bronze alloy. These alloys are about 85 86% copper (Cu) with other elements making the remainder. Flanges and flanged fittings shall be identified with the manufacturers name or trademark along with the ASTM specification number, the rating class for which the flange was designed (i.e., 150, 300, etc.), and B16 to indicate the flange conforms to the requirements of this standard. The nominal size shall be included, although it may be omitted from reducing flanges and reducing flanged fittings. Cast copper alloy flanged fittings may be manufactured from alloy C83600 a leaded red brass alloy or C922200 a leaded tin bronze alloy.

30

Flanges and flanged fittings furnished to this standard have the same flange diameters and drilling templates (bolt hole arrangement and size) as prescribed in ASME/ANSI B16.1, B16.5, and B16.42. Gasketing and bolting materials for use with cast copper flanges and flanged fittings shall be as prescribed in the applicable ANSI or ASME standards. Flared Copper Fittings COLD WATER SERVICE Flared fittings for use with flared copper tube for cold water applications with a maximum water pressure of 175 psig are manufactured to the requirements of ANSI/ASME B16.26 Cast Copper Alloy Fittings for Flared Copper Tubes. These fittings shall be produced to meet the general requirements of ASTM B 62, Alloy C83600 or the chemical and tensile requirements of ASTM B 584, alloys C83800 or C84400. Essentially, the elemental make-up of these cast brass fittings is approximately but not exactly equal to 85% Copper (Cu), 5% Tin (Sn), 5% Lead (Pb) and 5% Zinc (Zn). These flared fittings are limited in size from 3/8 nominal to 2 nominal as designated by ASTM B88 for Seamless Copper Water Tube. Marking of these fittings is limited to the manufacturers name or trademark and that identification may be omitted form fittings less than nominal size. (These flared fittings are normally limited to use in underground water service lines and in some rare cases above ground water distribution piping and should not be mistaken for 45 flared fittings manufactured for higher pressure applications.) NOTE: As additional information for flared fittings for copper tube applications it should be understood that forged or machined brass flared fittings for pressure applications are manufactured to the dimensions and configurations of SAE standards. The flare dimension and configuration for a 45 degree single flare is to be in accordance with the specifications of SAE J533 Wrought Copper Solder Joint Drainage Fittings DRAIN, WASTE AND VENT APPLICATIONS Wrought (wrot) copper alloy fittings used for drainage, waste, and vent applications with solder joints are manufactured to the requirements of ANSI/ASME B16.29 Wrought copper And Wrought Copper Alloy Solder Joint Drainage Fittings DWV. Fittings manufactured to this standard are to have a copper (Cu) content of not less than 84%. These fittings (socket end diameter) are sized in accordance with the requirements of the ASTM B306 Copper Drainage Tube while the size of any threaded connections (female or male) corresponds to nominal pipe sizing (slip-joints are excepted). Drainage fittings are required to be identified (marked) with a permanent mark containing the manufacturers name or trademark and DWV. All 90 degree fittings shall be pitched so that a slope of 0.25 in./ft. (2.1%) is developed in horizontal tube as referenced along a horizontal plane.

31

Wrought Copper Braze Joint Fittings: Fittings manufactured with braze cup depth sockets (short cups) shall be manufactured to the requirements of ASNI/ASME B16.50 Wrought Copper & Copper Alloy Braze-Joint Pressure Fittings These fittings may be manufactured from any one of the following alloys: C10200, C12000, C12200, or C23000 or any copper alloy that contains at least 84% Copper (Cu) and a maximum of 16% Zinc (Zn). Braze fittings (socket end diameter) are sized in accordance with the requirements of the ASTM B88 Seamless Copper Water Tube (1/4 8 nominal diameters), while the sizes of any threaded connections (female or male) correspond to nominal pipe sizing and the requirements of ANSI/ASME B1.20.1. The maximum operating pressure (MOP) for fittings manufactured to this standard shall be essentially equal to the maximum system operating pressure listed for type L annealed seamless copper water tube. It should be noted that maximum Standards Met: Copper Fitting is mainly used for air conditioner and Plumbing pipe connection We can produce the products as per ANSI B16.22, EN 1254-1 (BS 864-2), DIN2856,JIS H3401 standards. DIN 86090-2008 Fittings for butt welding into copper-nickel-alloy pipelines Elbows DIN 86037 Loose flanges and welding necks for pipes of copper-nickel-alloys ANSI/ASME B16.22 Wrot Joint Copper Fittings ANSI/ASME B16.22 Solder Ring Copper Fittings EN1254-1/BS864-2 End Feed Copper Fittings EN1254-1/BS864-2 Solder Ring Copper Fittings R410A High Pressure Copper Pipe Fittings Air-Conditioner Copper Pipe Fittings DWV Series Copper Pipe Fittings Brass Fittings Suitable for air conditioner, central air conditioner, car air conditioner, air conditioning and evaporator, seawater, cold water , hot water , drinking water and steam , oil , gas , medical gas etc. Which are no more than150 in temperature. Fitting: Elbow, Tee, Cap, U Bend, Filter, Tripod, P-trap, Crossover Component: Component of Splice Box Welding, Component of Holes Divider, Component of Car Air Conditioner, Component of Four Holes for Air Conditioner, Component of Air Conditioner Indoor, Divider Tee, Divider Pipe, Shape Pipe Joints

32

Copper Fittings We are the leading manufacturer and suppiler of copper pipe Fittings for Air Conditioning,Refrigeration , Water, Gas, Sanitation, Fir Protoction And General Purposes. Types of Copper Pipe Fitting: A range of pipe fittings are made of copper. Some of the common pipe fittings include: 450Elbow, 900Elbow, Coupling, Reducer Coupling, Tee & Caps Specifications: O. D. (mm): 6 to 104 Thickness (mm) : 0.50" to 1.626" Copper Alloy no. C12200 Standard:ASTM EN-1057 ACR Grade Copper Fittings With the help of our distinguished professionals, we have been able to bring forth a vast array of Copper Fittings ACR. These fittings are sourced from most trusted vendors of the market. All our products are manufactured using qualitative copper following industry standards & norms at the vendors' end. Owing to resistance to corrosion & abrasion, high mechanical strength and tensile strength; our products find their application in several industries. Further, clients can avail these in various specifications. Pulmbing Copper Fittings We are committed to trade and supply a wide and qualitative collection of Copper Fitting Plumbings. Available in varied dimensions and sizes, these plumbings are manufactured with the use of high-grade copper at our vendors' manufacturing unit. Furthermore, owing to their high tensile & mechanical strength, corrosion resistance and sturdiness; these reasonably priced products are highly demanded by our esteemed customers spread throughout the country. Copper Fittings For VRF/VRV Project A broad range of Variable refrigerant flow (VRF) and Variable refrigerant volume (VRV) fittings is offered in various dimensional specifications. These fittings find exclusive usage in various fabrication and engineering projects. Designed with high precision and processed under advanced technologies these fittings are carefully tested to ensure high precision and dimensional accuracy.
33

BS EN1254-2 Brass Fittings


Product Description:
Straight Male Coupler (CxM) (Taper thread) 151/2'', 221/2'',223/4'', 281'', 351 1/4'', 421 1/2'', 542'' Hexagon Nipple with Taper thread 1/8", 1/4", 3/8", 1/2", 3/4", 1", 1-1/4", 11/2", 2", 2-1/2", 3", 4" 1/2"x3/4", 3/4"x1", 1"x1-1/4" Hexagon Nipple with Parallel thread Reducing Male Nipple 1/8", 1/4", 3/8", 1/2", 3/4", 1", 1-1/4", 1-1/2", 2"

Comp St. Male Coupler (CxM) (Parallel Thread)

15x1/2", 15x3/4", 22x3/4", 22x1", 28x1", 35x1-1/4", 42x1-1/2", 54x2"

Tail Piece Fittings

1/4"x1/8",3/8"x1/8", 3/8"x1/4",1/2"x3/8", 3/4''1/2'',1"x1/2", 1''3/4'',1-1/4''1'', 1 1/2''1 1/4'', 2''1 1/2'' 1/2''F, 3/4''F 1''F, 1 1/4''F 1 1/2''F, 2''F

Bush, MxF,Parallel Thread

1/2"x3/8", 3/4x1/2",1x1/2", 1x3/4", 1-1/4"x3/4", 1-1/4"x1", 1-1/2"x1",1-1/2"x1-1/4", 2"x1", 2"x1-1/4", 2"x1-1/2"

Female Adapter

Reducing Bush,MxF, Taper (M) x Parallel (F)

Comp. Female Coupling Brass Manifold

1/4"x1/8", 3/8"x1/8",3/8"x1/4", 1/2"x1/8", 1/2"x1/4", 1/2"x3/8", 3/4x1/2",1x1/2",1x3/4",11/4"x3/4", 1-1/4"x1",1-1/2"x1/2",11/2"x3/4", 1-1/2"x1",1-1/2"x1-1/4", 2"x1/2", 2x3/4",2"x1", 2"x1-1/4",2"x11/2", 2-1/2"x1-1/2",2-1/2"x2",3"x2", 3"x2-1/2",4"x2-1/2",4"x3" 15x1/2"F, 15x3/4"F, 15x1"F

Straight Female Coupler

15x1/2",22x1/2", 22x3/4",28x1", 35x1-1/4",42x11/2", 54x2",67x2-1/2", 67x2-1/2",76x3" 1/2'', 3/4'',1'', 1 1/4'',1 1/2'', 2''

Straight Double Female Coupler

St. Female Reducing Coupler

3/4''1/2'',1''3/4'', 1''1/2'', 1-1/2''1-1/4'' 1-1/4''3/4'', 1-1/2''3/4'' 1-1/2''1'', 2''1'' 2''1-1/4'',2''1-1/2''

Straight Female Union

151/2'',223/4'', 281'',351 1/4'', 421 1/2'',542'' 15, 22, 28, 35

Straight Male Union Wall Ring

151/2'',223/4'', 281'',351 1/4'', 421 1/2'',542'' 15, 22, 28, 35

Nut (Metric/BS)

15.88x6.35x8, 15.88x6.35x12, 15.88x6.35x16,19.05x6.35x12, 19.05x6.35x16,22.23x6.35x18, 28.6x6.35x24 Metric: 6, 8, 10, 12, 16, 19, 22 BS: 6.35, 9.52, 12.7, 15.88, 19.05, 22.23

Split Ring Hanger 90 Female Elbow 15x1/2", 22x3/4" 28x1", 35x1-1/4" 42x1-1/2", 54x2" 67x2-1/2", 76x3" 108x4"

15, 22, 28, 35 or other sizes

Specifications: Long Nut /Short Nut /Cap Nut /Forged Brass Nut /Union /Union Tee /Plug / Valve Core Remover /Female Connector / Male Connector /Reducer (Solder) /Reducer (Flare) / FB Liquid Distributor Standard Met: Compression fittings made to BS EN1254-2 in both standard brass and dezincification resistant (DZR) brass
34

Copper bar
Free Cutting Brass Alloy No. C3602 C3601 C3604 C3603 C3605 Forging Brass Alloy No. C3712 C3771 Cu 58-62 58-62 57-61 Cu 59-63 59-63 59-63 57-61 57-61 57-61 56-60 Chemical Composition (%) Pb Fe Sn + Fe 1.8-3.7 0.5 Max 1.2 Max 1.8-3.7 0.5 Max 1.2 Max 1.8-3.7 0.3 Max 0.5 Max 1.8-3.7 0.5 Max 1.2 Max 1.8-3.7 0.5 Max 1.2 Max 1.8-3.7 0.6 Max 0.6 Max 3.5-4.5 1.2 Max 1. 2 Max Zn Rem Rem Rem Rem Rem Rem Rem P

Chemical Composition (%) Pb Fe Sn + Fe 0.25-1.2 0.8 Max 0.25-1.2 0.8 Max 1.0-2.5 1.0 Max

Zn Rem Rem Rem

35

Copper Strips
Product Ranges of copper strip and brass strip: ISO (ISO) Cu-ETP Cu-DHP ISO (ISO) CuZn10 CuZn30 CuZn35 US (ASTM) C11000 C12200 US (ASTM) C22000 C26000 C26800 Japan (JIS) C1100 C1220 Japan (JIS) C2200 C2600 C2680 UK (BS) C101 C106 UK (BS) CZ101 CZ106 CZ107 Germany (DIN) R-Cu57 Sf-Cu Germany (DIN) CuZn10 CuZn30 CuZn36 GB T2 TP2

Copper plate and strip

Brass plate and strip

H 90 H 70 H 68 H 65 H 62 GB QSn6.50.1 QSn6.50.4 QSn4-0.3 QSn8-0.3 GB BZn1520 BZn1818 BZn1826

ISO (ISO) CuSn6 Bronze plate and strip CuSn4 CuSn8 ISO (ISO) Nickel silver plate and strip CuNi15Zn21 CuNi18Zn20 CuNi18Zn27 Available Thickness and Width Ranges Thickness Range inch min. 0.0013 0.0040 0.0200 0.0320 0.0700 max. 0.0040 0.0200 0.0320 0.0700 mm min. 0.0350 0.1000 0.5000 0.8000

US (ASTM) C51900

Japan (JIS) C5191

UK (BS) PB103

Germany (DIN) CuSn6

C51100 C52100 US (ASTM) C75400 C75200 C77000

C5111 C5212 Japan (JIS)

PB101 PB104 UK (BS) NS105

CuSn4 CuSn8 Germany (DIN)

C7521 C7701

NS106 NS107

CuNi18Zn20 CuNi18Zn27

Width Range max. 0.1000 0.5000 0.8000 1.8000 inch min. 0.5 0.5 0.5 0.5 max. 13 24 24 24 mm min. 12.5 12.5 12.5 12.5 max. 325 610 610 610
36

Red Brass Chemical Composition


Alloy No. C2100 C2200 C2300 C2400 Chemical Composition (%) Cu 94.0~96.0 89.0~91.0 84.0~86.0 78.5~81.5 Pb 0.05 0.05 0.05 0.05 Fe 0.05 0.05 0.05 0.05 Sn Zn bal. bal. bal. bal. P

Brass Chemical Composition


Alloy No. C2600 C2680 C2720 C2801 Chemical Composition (%) Cu 68.5~71.5 64.0~68 62.0~64.0 59.0~62.0 Plate Thikness Width Length Thickness Pb 0.05 0.05 0.07 0.10 Fe 0.05 0.05 0.07 0.07 Sn Zn bal. bal. bal. bal. Coil Width Length P

Product Dimension
Alloy No. C2100 C2200 C2300 C2400 C2600 C2680 C2720 C2801

0.10~3.50

20~610

0.1~4.0

10~610

Standards Met: For copper strip: - Min trial order 1 ton each thickness (only for the thickness: 0.3mm, 0.4mm, 0.5mm, 0.6mm, 0.7mm, 0.8mm, 0.9mm, 1.0mm, 1.1mm, 1.2mm, 1.5mm. For other thickness, the trial order will be 4tons of each thickness) - Min normal order: 4tons each thickness For copper foil (copper tape): Min trial order 100kg each thickness (normal thickness: 0.02mm, 0.025mm, 0.03mm, 0.04mm, 0.05mm, 0.06mm, 0.07mm, 0.08mm, 0.09mm, 0.10mm, 0.12mm, 0.15mm) - Min normal order: 300kgs each thickness Applications for copper strip and brass Strip: Copper strip for CCA, CCS. Copper strip and sheet for Radiator Copper strip and sheet for Transformer Copper strip for Water Heater exchanger unit Copper strip for Automotive manufacturers Brass strip and sheet for Electrical equipment manufacturers Copper strip and brass strip and bronze strip for Mints (for coinage) Copper strips for Connectors Copper strips for Relay Springs Copper strips for Electronic components
37

Copper Foils
Product Description
Copper foil for PCB We can supply copper foil for li-lon battery with 0.008~0.007mm thickness for different size, or we can design and produce special size of product according to customer's requirement. Product name single side foil Thickness(mm) 0.008 Area weight(g/m2) 764 Tensile strength(Kg/cm2) 20 Elongation % 1.5

single 0.01 854 20 side foil single, 0.012 1035 20 double side foil single, 0.018 1398 25 double side foil single 0.032 27510 27.5 side foil single 0.07 61015 27.5 side foil Note: The copper content of above product is more than 99.80%. width :50~1200mm.
Type Area weight g/m2 CFEC 153/230/305/435/610 oz/ft2 0.5/0.75/1/1.4/2 Width mm 500~1295 Coil weight Kg 50~350

1.5 2.0 2.0 3.0 3.0

Appearance

Usage

pink roughening surface gray roughening surface

CFEZ

for varied paper based, glass fiber ccl

Chemical and Physical Property of Copper Foil: Specification Tolerance Copper content % Area Thickness Weight weight m g/m2 153 18 5 99.8 230 25 305 35 435 50 610 70

Resistivity . g/m2

Max resistivity m

Tensile strength MPa(N/mm2) STD-E HDE 205 235 275 275 275 103 156 205 205 205

Elongation STDE 2 2.5 3 3 3 HDE 5 7.5 10 10 15

High temperature resistance

0.1640 0.1620

7 5.5 3.5 2.5 1.75

The surface of copper foil dont change color, under 200 inside oven for 60 minutes

Note:STD-E represents standard electrodeposited copper foil, HD-E represents high drawing copper foil.

38