SCADA Genesis64 Iconics
SCADA Genesis64 Iconics
SCADA Genesis64 Iconics
GENESIS64
Getting Started
Version 10.6
2011 ICONICS, Inc. All rights reserved worldwide. This document may not be reproduced or copied in any manner without written authorization from ICONICS, Inc. The information contained within this document is subject to change without notice. ICONICS, Inc. does not guarantee the accuracy of the information. GENESIS64, Hyper Historian, Pocket GENESIS, BizViz and their respective modules, OPC-To-The-Core, and Visualize Your Enterprise are trademarks of ICONICS, Inc. Windows, Windows XP, Windows 2000, Windows 2003 Server, Windows CE, Windows NT, Windows 2003-64, Windows Vista, Windows Server 2008, Windows 7 and Windows Server 2008 R2 are registered trademarks of Microsoft Corp. in the United States and other countries. Other product and company names mentioned herein may be trademarks or registered trademarks of their respective owners. Document No. UG-GEN-1060 ii ICONICS
License Agreement
ICONICS
iii
License Agreement
ICONICS SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, IMPLIED WARRANTIES OF TITLE, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN PARTICULAR, WITH RESPECT TO ANY PARTICULAR APPLICATION, USE OR PURPOSE, IN NO EVENT SHALL ICONICS INC. BE LIABLE FOR ANY OTHER COMMERCIAL DAMAGE, INCLUDING BUT NOT LIMITED TO SPECIAL, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES. ICONICS DOES NOT WARRANT THAT THE FUNCTIONS CONTAINED IN THE PROGRAM WILL MEET YOUR REQUIREMENTS OR THAT THE OPERATION OF THE PROGRAM WILL BE UNINTERRUPTED OR ERROR FREE.
LIMITATION OF REMEDIES ICONICS entire liability and your exclusive remedy shall be the replacement of any DVD-ROM or diskette not meeting ICONICS Limited Warranty which is returned to ICONICS with a copy of your receipt within the warranty period. The remedy for breach of this warranty shall be limited to replacement and shall not encompass any other damages including but not limited to loss of profit, special, incidental, consequential, or other similar claims arising out of the use or inability to use such program even if ICONICS has been advised of the possibility of such damages, or for any claim by any other third party. GENERAL This Agreement will be governed by the laws of the Commonwealth of Massachusetts. Should you have any questions concerning this Agreement, you may contact ICONICS in writing at:
iv
ICONICS
Table of Contents
TABLE OF CONTENTS
1 GENESIS64 OVERVIEW ..................................................................... 1-1 1.1 INTRODUCTION ................................................................................... 1-1 1.2 WHAT IS GENESIS64? ...................................................................... 1-2 1.3 WHAT IS OPC-UA? ............................................................................ 1-2 2 SYSTEM REQUIREMENTS ............................................................... 2-1 3 INSTALLING GENESIS64 .................................................................. 3-1 3.1 3.2 3.3 3.4 3.5 STARTING THE INSTALL ...................................................................... 3-1 TYPICAL INSTALLATION ..................................................................... 3-2 CUSTOM INSTALLATION ..................................................................... 3-5 TRENDWORX64 DATABASE GROUP CONNECTION ........................... 3-6 UNINSTALLING GENESIS64 .............................................................. 3-6
4 ICONICS SOFTWARE LICENSING ................................................. 4-1 4.1 SOFTWARE AND HARDWARE KEYS .................................................... 4-1 4.1.1 Software Licensing ....................................................................... 4-1 4.1.2 Hardware Key .............................................................................. 4-1 4.2 LICENSING UTILITY ............................................................................ 4-2 4.2.1 Running the Licensing Utility ...................................................... 4-2 4.2.2 License File .................................................................................. 4-3 4.2.3 Activating the 30-day Trial/Emergency License .......................... 4-4 4.2.4 Killing a Software Key License .................................................... 4-6 4.3 LICENSE VIEWER ................................................................................ 4-8 4.4 WEB LICENSING ................................................................................ 4-10 4.4.1 Acquiring a New Software License ............................................ 4-10 4.4.2 Adding to an Existing Software License .................................... 4-16 4.4.3 Upgrading a Software License Key ........................................... 4-18 4.4.4 Upgrading a Hardware License Key ......................................... 4-26 4.4.5 Licensing the New Version ......................................................... 4-26 4.5 DEMO MODE ..................................................................................... 4-27
ICONICS
i.
Table of Contents
5 GENDEMO ............................................................................................. 5-1 5.1 INTRODUCTION ................................................................................... 5-1 5.2 GENDEMO TOOLBAR .......................................................................... 5-2 5.3 GRAPHWORX64 INTERACTIVE TUTORIALS IN THE LEARNING CENTER 5-2 5.4 ICONICS PRODUCT PRESENTATIONS ................................................ 5-3 5.5 GETTING HELP FROM GENDEMO ....................................................... 5-4 5.6 INDUSTRY CASE STUDIES AND EXAMPLES ........................................ 5-4 6 GENESIS64 QUICK START................................................................ 6-1 6.1 6.2 6.3 6.4 6.5 6.6 6.7 INTRODUCTION ................................................................................... 6-1 GRAPHWORX64 ................................................................................. 6-1 ALARMWORX64 ................................................................................ 6-2 TRENDWORX64 ................................................................................. 6-2 EARTHWORX...................................................................................... 6-3 WORKBENCH ...................................................................................... 6-3 ADDITIONAL TOOLS AND UTILITIES................................................... 6-5
7 HELP AND TECHNICAL SUPPORT ................................................ 7-1 7.1 ONLINE HELP ...................................................................................... 7-1 7.2 PRODUCT VIDEOS ............................................................................... 7-1 7.3 TRAINING CLASSES............................................................................. 7-1 7.4 TECHNICAL SUPPORT.......................................................................... 7-2 7.4.1 Global Support and Services........................................................ 7-2 7.4.2 ICONICS Knowledge Base .......................................................... 7-2 7.4.3 Online Support ............................................................................. 7-3 7.4.4 Telephone Support........................................................................ 7-3 7.4.5 E-mail Support ............................................................................. 7-4
vi
ICONICS
1 GENESIS64 OVERVIEW
1.1 Introduction
Welcome to ICONICS GENESIS64, a powerful, 64-bit, Web-enabled, OPC HMI/SCADA suite. GENESIS64 takes full advantage of the convergence of 64-bit-based computing machinery, the release of new Microsoft operating systems (Windows 7 and Windows Server 2008 R2) and the growing customer demand for engaging three-dimensional graphic visualization of business processes. GENESIS64, which is compatible with Windows 7, as well as certified for both Windows Vista and Windows Server 2008, includes several solutions that allow for connectivity from the plant floor to corporate business systems to provide a 360degree view of an entire organization. It was designed from the ground up to utilize new Microsoft technologies including: Entirely built using Microsoft .NET 4.0 Windows Presentation Foundation (WPF) Microsoft Silverlight 3D Hardware-accelerated Visualization Windows Communication Foundation (WCF) OPC Unified Architecture (OPC-UA) Windows User Access Control (UAC) Persistence Windows 7 Search & Organize Microsoft Windows 7 Multitouch Microsoft Windows Sidebar Gadgets Integrated Microsoft Silverlight Technologoy Microsoft Bing Maps
ICONICS GENESIS64 suite is comprised of the following products: GraphWorX64 AlarmWorX64 TrendWorX64 EarthWorX Workbench
ICONICS
1-1
GENESIS64 Architecture
This Getting Started manual explains how you can: Install the GENESIS64 software. Familiarize yourself with and start using the Workbench multi-functional, centralized Webbased environment Access online help and technical support.
Note: This manual is an abbreviated version of the full GENESIS64 Help documentation, which is available in the GENESIS64 Product help.
GENESIS64 Architecture
Figure 1.1 shows the OPC Architecture, which was introduced by the OPC Foundation. By following the OPC Architecture, a device needs only one standard driver, which is an OPC-compliant server. All OPC-compliant client applications can then be connected to that device, either locally or over a network. Furthermore, connections can be made to more than one OPC server at the same time.
Figure 1.1. OPC-Based Client-Server Architecture Any OPC client application can connect to any OPC server. In other words, OPC offers true Plug-and-Play capability in the fields of HMI and industrial automation. OPC server types include OPC Data Access (DA), OPC Alarm and Events (AE), and OPC Historical Data Access (HDA). The AlarmWorX64 application, which has both client and server components, is an example of a real-time data display where the focus is on alarm and event type data that is specified by the OPC-AE standard. You can configure AlarmWorX64 to display real time alarm events inside a viewer application that originates on an alarm server application that is monitoring alarm-based OPC-AE devices.
ICONICS
1-3
GENESIS64 Architecture
1-4
ICONICS
2 SYSTEM REQUIREMENTS
GENESIS64 has the following minimum system requirements. Your systems must meet the minimum requirement before you can install GENESIS64. CPU: Dual Core 64-bit processors (AMD Athlon 64 X2, Intel Core 2 Duo, Intel Xeon, and AMD Phenom) Memory: Minimum: 2 GB of RAM Recommended: 6 GB of RAM Hard Disk: Minimum: 4.0 GB free hard disk space on system drive Recommended: 10 GB free hard disk space Drive: 8X speed CD-ROM/DVD-ROM Video Card: Display Resolution Minimum: 1024x768, 32 bit color Recommended: onboard Video Memory (256Megs), DirectX 9 or 10 Video Card or better Operating System: Any Windows 64 operating system, including: Microsoft Windows 7 x64 (Professional or Ultimate Edition) Microsoft Windows Server 2008 R2 x64 Microsoft Windows Vista x64 SP2, Windows Server 2008 x64, Windows Server 2003 x64 .NET Framework: Microsoft .NET Framework 4.0 ICONICS 2-1
Microsoft Internet Information Services (IIS) 7.0 SQL Server: Microsoft SQL Server 2008 Express Edition Microsoft SQL Server 2005 Workgroup/Standard/Enterprise Edition SP2. Microsoft SQL Server 2005 Express Edition SP2 with Microsoft SQL Server Management Studio Express.
Note. It is recommended that the systems page file size be a minimum of four (4) times the size of installed (physical) RAM. Note. The connection to a SQL Server data source may be either local or remote.
2-2
ICONICS
3 INSTALLING GENESIS64
The following steps detail the GENESIS64 system installation. GENESIS64's installation uses a standard InstallShield installer to provide you with options for installing components, adding new or existing users, configuring the database engine that you use and the size of the tables that are created, and more. Warning. Prior to installation, verify that the system meets minimum hardware and software requirements, as described in the System Requirements section. Installation will abort if the minimum requirements are not met. Important Note: Uninstall previous versions of GENESIS64 before installing 10.6 of GENESIS64.
2. 3.
4.
ICONICS
3-1
Installing GENESIS64
Custom installation allows you to pick the options to be installed. Since the Setup procedure varies slightly depending on the installation type you choose, the installation of each is described fully in the two sections that follow. Refer to Typical Installation below or Custom Installation on page 3-5.
2.
3.
3-2
Installing GENESIS64
4.
The Typical installation will now ask you if youd like to install the GenDemo that includes sample displays, examples and tutorials to get you up and running. Select the option, if desired, and click Next. At this time, additional components will be installed automatically. In the User Setup dialog box you can choose to use either a local machine account or a domain security account, as well as create a new user or use an existing user account. Either accept the local machine account or click the Domain radio button and enter the domain machine account, as shown in the following User Setup dialog box.
5.
Either select the New User radio button and enter the User Name and Password for that account; or select the Existing User radio button and select the User Name of the account then provide the password for that account. Then click the Finish button. ICONICS 3-3
Installing GENESIS64 6.
The GENESIS SQL Databases Installation window will now appear. In the window that appears below, you can either leave the Include Sample Data check box enabled (in order to install sample data that you can experiment with) or disable this check box to install blank tables. Advanced configuration will allow settings for additional sizing options on the database and log files.
7. 8.
Click the Install button to continue the installation. If Setup detects previously installed GENESIS64 databases it posts the Overwrite Database dialog box, shown below. Click either Overwrite Existing Database or Don't Overwrite to continue. Before doing so though, you can enable the check box to enforce this choice as your default for the remaining database files.
3-4
ICONICS
Installing GENESIS64
After completing the installation, the Wizard Completed dialog box appears. Click the Finish button. Note: It's generally a good idea to restart your system, although the installation doesn't require that you do so. Should the installation appear to hang, check to see that there aren't any alert boxes posted that require dismissal prior to completing the installation.
Clicking Next will bring up the Database Server Dialog. This will allow you to indicate the database server you wish to install to. The install will search your drives and populate a list of options. If for any reason the desired database server is not listed, use the Browse button to navigate to it. You should use the credentials that the database server is secured under which could involve using Windows authentication or a specific SQL Server authentication. Indicate and type your Login ID and Password if necessary. Click Next to continue. 3-5
ICONICS
Installing GENESIS64
Click the Install button to continue the installation. If Setup detects previously installed GENESIS64 databases, it posts the Overwrite Database dialog box. Click either Overwrite Existing Database or Don't Overwrite to continue. Before doing so though, you can enable the checkbox to enforce this choice as your default for the remaining database files.
After completing the installation, the Wizard Completed dialog box appears. Click the Finish button.
3-6
ICONICS
A green status light will illuminate upon successful connection. Should the USB key be missing or unplugged during operation of GENESIS64 software, plug the USB key back in either within an hour of removal or upon system reboot; otherwise the hardware-based license will not be immediately recognized. Should you require a replacement key, visit http://www.iconics.com/supportworx. New users must create an account through the ICONICS Web Licensing Utility in order to request replacement keys.
4-2
ICONICS
Once you have opened the Software Licensing Utility, you can browse for the site key (License File) itself. Either click on the Browse button in the License File section of the window OR click on File in the top menu, then Select License File .
This brings up the Windows Explorer so that you may browse for the License File itself. Once you have located the file, double-click it or click Open to proceed.
ICONICS
4-3
Activating the 30-day Trial/Emergency License Within the Licensing Utility (Software License Activation for .NET) dialog box, you can click on the Activate Trial/Emerg. License box to initiate a 30-day trial/emergency license. NOTE: This license can be activated only once per machine.
You will then see a warning about proceeding with activating the 30-day trial/emergency license. Click Yes, should you wish to proceed.
4-4
ICONICS
You will then see an additional warning confirming that you understand that enabling the trial license will invalidate any other software license that is currently active on the machine. Click Yes should you wish to proceed.
Once the 30-day trial/emergency license has been enabled, you will see the following messages:
The PC will then be authorized to run for a one-time only, 30-day backup period. The PC can be fully authorized at any time during or at the conclusion of this temporary backup period. Clicking No in the initial windows returns you to the Licensing Utility (Software License Activation for .NET) dialog box and preserves the existing license.
ICONICS
4-5
Note: Temporary backup license authorization is intended for urgent backup situations only. Clicking OK invalidates the existing license and activates a temporary backup authorization, permanently overwriting any existing license. Thus, please use caution when activating a temporary backup license authorization.
4.2.4
Killing a Software Key License Killing a software key license deletes it and removes the current software license from the machine. To kill or delete the existing software license: 1. Select Kill Current License within the Licensing Utility (Software License Activation for .NET) dialog box. Using this option, you can remove the current software license from the current machine.
4-6
ICONICS
IMPORTANT: If you kill your license, you need to get a new license from ICONICS to restart your GENESIS64 product.
2.
Click Yes to continue, or click No to exit. Clicking Yes displays one of the following warning messages. If you are killing a trial or emergency license, once you click Yes you are done. Note: A trial or emergency license cannot be credited back to the Web-based License Generator using the Kill Code. If you are killing a permanent, registered license, after you click Yes, the following warning message appears. Notice that the message lists the old site key, and a kill code. It also lists a .TXT file that has been written to the PC's desktop; the file name begins with "KillCode". This file contains the old site key and kill code that are listed in the message.
ICONICS
4-7
Click Yes to copy the kill code to the Windows Clipboard so that you can paste it elsewhere, such as in an e-mail to ICONICS Support or on the ICONICS Web Licensing Utility. If you don't need to copy the kill code at this time, click No. Look on the desktop for the KillCode*.TXT file. Keep this file, and copy it to a safe location! You will have to use the information it contains to confirm that you have killed your license (via either the ICONICS Order Entry Department or the ICONICS Web Licensing Utility). Proceed with the online steps described in 4.4.3.1 Killing a License via the ICONICS Web Licensing Utility
4.
5.
Note: To reinstate a permanent license that you killed, you will need to provide the KillCode*.TXT file to ICONICS. Note: If you uninstall the Software License Utility, the KillCode*.TXT file will be deleted. For this reason, make sure you copy the KillCode*.TXT file to a safe location or be sure to note or print its content before uninstalling the Software License Utility on the PC. [* = Site Key that was killed.]
4-8
The two mode types are not interchangeable and require you to buy a new license to upgrade your existing license status. At any time, you can use the License Viewer to review the license status of ICONICS products installed on that computer. You can access the License Viewer in either of the following ways: From the Windows desktop: click Start > All Programs > ICONICS Licensing > ICONICS .NET Licensing > License Viewer. From the Workbench: from the Tools ribbon click the Licensing button. Or from the File menu, select Tools, and then Licensing. The License Viewer displays as shown below.
The tab that displays initially is the Overview tab, where you can see general information about the license for the server that the node points to. You can view license information for GENESIS64, AnalytiX, Data Connectors, BizViz, and AlarmWorX Multimedia product features by using the tabs for those products. To locate the nodes where individual product features are consuming the server's license counts, use the Diagnostics tab. ICONICS 4-9
4.4.1.1
Issuing a New Software License 1. On the machine where you want the GENESIS64 license to reside, open the License Utility by going to Start -> Programs -> ICONICS Licensing -> ICONICS .NET Licensing -> Licensing Utility. This should open the Software License Activation for .NET window. You will see a dialog come up with a Site Code and No Current Site Key within the Site Key text box. Leave this window open.
2.
4-10
ICONICS
3.
Go to http://www.iconics.com/supportworx and launch the Web Licensing Utility Site by clicking on the License Product link on the right side of the page.
Or, from ICONICS Web site (http://www.iconics.com), select License Your Product from the bottom-right Customer Connection area. ICONICS 4-11
The main page of the Web Licensing Utility will load. Click on the Software button to access the Software License Options.
5.
You will be required to log in to access the Software License Options. Enter your email address and password and click on the LOGIN button. If you do not yet have an account, you can create one by clicking on the Create New Account link near the bottom of the page.
4-12
ICONICS
Once you have logged into the Web site, click on the New License link in the top navigation bar. Enter your Product Registration Numbers and Customer Keys for the products to license, then click Next. NOTE: Your Product Registration Number and Customer Key are usually inside the DVD package that ICONICS sent to you.
7.
8.
In the next screen, you will be requested to identify the end user for whom the license is being issued. You can look up a list of users that have been previously entered by clicking on the Existing End Users link or can enter a new one by clicking on the Create New link.
9.
Clicking the Existing End Users link will open a new window with a list of previously entered end users (either entered by you or tied to the product registration numbers entered in the previous screen). Select an end user from the list and click Select or double-click the selected end user.
ICONICS
4-13
If you, yourself, are the end user and you are not listed in the grid, you can click on the I am the End User link to enter your data as the new end user. After identifying the end user, click on Next.
10. In the next screen, you will see a list of the products that are available for you to license. Check all the products that you would like to license. Copy the Site Code from the license utility of the destination machine and paste it into the Site Code box of the current Web page, then click on Next.
11. Review the license information before proceeding. Click on Generate Key to issue the new site key.
4-14
ICONICS
12. The next page will show you a summary of what will be your license, as well as your Site Code and License File.
13. Download the license file (*.glic) by clicking on the link. You will need this file to license the machine. NOTE: If you misplace the file after receiving it, you can use the View License link with your Product Registration Number to download it again. 14. In the Software License Activation Utility, click on the Browse button and look for the license file that you downloaded from ICONICS Web site. 15. Once you have selected the file and the License File textbox shows the file path, click on the Activate License button. 16. You should then receive a popup message indicating the status of the license activation. You can click on OK to close the dialog.
ICONICS
4-15
17. The Software License Activation Utility should now show the current license information, similar to the image below.
18. Notice that the Site Code may change, as expected, but the Site Key should be the same one you saw on the Web site. 4.4.2 Adding to an Existing Software License 1. Go to http://www.iconics.com/supportworx and launch the Web Licensing Utility by clicking on License Your Product. Once you have logged into the Web site and accessed the Software License main page, click on the Add to License link on the top navigation bar.
2.
4-16
ICONICS
Enter your Existing Site Key, Product Registration Numbers and Customer Keys, then click Next.
4.
In the next screen, you will see a summary of the current license and a list of products that are available for you to add to the existing license. Check all the products that you would like to license. Copy the Site Code from the License Utility of the destination machine and paste it into the Site Code text box of the current Web page, then click Next.
5.
Review the license information before proceeding. Select Generate Key as shown in the following image.
ICONICS
4-17
6.
The next screen will display the new site key and the link to your license file. Follow steps 13 to 18 from 4.4.1.1 Issuing a New Software License to complete the licensing process.
4.4.3
Upgrading a Software License Key There are four basic steps when it comes to upgrading a license via the Web Licensing Utility: Step 1: Kill the older version license and credit it on our Web site Step 2: Upgrade the license on our Web site Step 3: Uninstall the older version of software and install the newer version Step 4: License the newer version The order in which you do Step 2 and Step 3 does not matter.
4-18
ICONICS
Killing a License via the ICONICS Web Licensing Utility See Section 4.2.4 Killing a Software Key License for the initial steps on how to kill a license within the Licensing Utility (Software License Activation for .NET) provided on the GENESIS64 DVD. Be sure to take note of the Site Key and Kill Confirmation Code. This information is necessary to put the license back on the ICONICS Web site. NOTE: This information is also in the KillCode*.TXT file. [* = Site Key that was killed.] Once you have the Kill Code, follow these additional steps: 1. Go to http://www.iconics.com/supportworx and launch the Web Licensing Utility Site by clicking on the License Your Product button.
2.
The main page of the Web Licensing Utility will load. Click on the Software button to access the Software License Options.
ICONICS
4-19
3.
You will be required to log in to access the Software License Options. Enter your email address and password and click on the LOGIN button. If you do not yet have an account, you can create one by clicking on the Create New Account link near the bottom of the page.
4.
Click on the Kill License link on the top navigation bar. ICONICS
4-20
Copy the Site Key from the License Utility on your source machine into the Site Key field on the Web page, then copy the Kill Confirmation Code into the Kill Code field on the Web page. Next, click on the Remove Key button on the Web page.
6.
You will get a message confirming that the Site Key has been successfully deleted as shown in the image below. The products associated with the deleted Site Key will now be available to be relicensed.
ICONICS
4-21
Upgrading the License on ICONICS Web Site See Section 4.2.4 Killing a Software Key License for the initial steps on how to kill a license within the Licensing Utility (Software License Activation for .NET) provided on the GENESIS64 DVD. Be sure to take note of the Site Key and Kill Confirmation Code. This information is necessary to put the license back on the ICONICS Web site. NOTE: This information is also in the KillCode*.TXT file. [* = Site Key that was killed.] 1. After you have copied your Site Key and Kill Confirmation Code in the previous step (either physically or electronically), you can now visit http://www.iconics.com/supportworx.asp.
2.
Next, click on the License Your Product button. This opens a new Web page, as shown below.
4-22
ICONICS
Click on the Software button to proceed. You will then be required to enter your email address and password for the site, as shown below. If you do not already have a login for this page, click on the Create New Account link near the bottom of the page.
4. 5.
Once you have logged in, click on the Kill License link near the top of the page. Next, fill in your Site Key and Kill Code information that you copied while killing your previous license (see 4.2.4 Killing a Software Key License).
ICONICS
4-23
Once you kill the license on ICONICS Web site, you will receive an email containing the following information: Site Key Kill Code Product for which you have killed the license The Web page itself should now look similar to the figure below.
7.
At this point, you have completed killing the license. Notice that in the final Kill License page, as shown above, it states that if the license is eligible, it can be upgraded to the latest version and it provides a link for availability.
4.4.3.3
Checking License Upgrade Availability The easiest way to check if your license is available for an upgrade is by clicking the link on the page immediately after you kill the license. Clicking the link brings you to the Upgrade License Page. You can also get to this page by clicking on the Upgrade License link in the tree control (third item).
4-24
ICONICS
Follow these steps to upgrade your license. 1. On the Upgrade License page, fill in your Product Registration Number and Customer Key. This is the same information you received in the Web page and in your email after you have killed the license on our Web site. Click on Next when you have filled in the necessary information. If the license is available for an upgrade, you will see the available license on the page.
2. 3.
4.
5.
6.
Notice that the Product Description here shows a different product with an earlier version license (Version 8). Yours should reflect the license you have for your product. Check the available product that you would like to upgrade and click on Next. The next page is a confirmation page. Check that the information shown is correct and click on the Upgrade button to proceed. On the new page that loads next, you can see a list of upgraded products. Notice that the Product Description shows a license for a later version product (Version 9.2) instead of the earlier one (Version 8).
ICONICS
4-25
You should also receive an email with the license upgrade information.
4.4.4
Upgrading a Hardware License Key Upgrading a hardware key license is similar to upgrading the software key license. You would follow the exact same procedure as upgrading a software license. In the case of a Hardware key License though, you will need the USB dongle in order to kill the license from it and put the new one onto the key.
4.4.5
Licensing the New Version Now that you have upgraded the license, you can follow the regular procedure to license your machine with the new version. When it asks you for the Product Registration Number and the Customer Key, you can provide the same one. This information was sent to you in the last step of upgrading your license via email. If you need more information on how to license the machine with the upgraded license, please consult our application notes titled Licensing Using the ICONICS Web License Utility for Software Key Licenses and Licensing Using the ICONICS Web License Utility for Hardware Key Licenses, as it pertains to your individual situation. These Application Notes and more can be found via the Info Center on the GENESIS64 DVD.
4-26
ICONICS
Running GENESIS64 longer than the 12-hour limit generates a message stating that the demo time has been exceeded. You must then exit GENESIS64 and reboot the PC. On restarting GENESIS64, you will get another 12-hour block of time in which to run. If there are more than 64tags on a particular screen, gray keys (or whatever is configured as the Point Failure character) will appear in place of the actual I/O data. If you intend to run in Demo Mode, go to Chapter 5 to read about GenDemo.
ICONICS
4-27
4-28
ICONICS
5 GENDEMO
5.1 Introduction
You can get a sense of the rich applications that can be created by using GenDemo. GenDemo is a set of GraphWorX64 (.gdfx) display files installed with your system to help you explore and learn about GENESIS64 and its products and features. This chapter provides a brief overview of GenDemo; you are strongly encouraged to explore all files available in GenDemo. To launch the GenDemo, from the Windows Start menu, select Programs > ICONICS > GENESIS64 > GenDemo. This opens the GenDemo home page, shown below.
ICONICS
5-1
GenDemo
The left-most buttons on the toolbar are the play controls. From left to right, they let you skip to the beginning, go back one, choose from a list called the carousel, go ahead one, and skip to the end. The forward-pointing button, highlighted here on the left, is the Play button. Clicking the Play button advances you to the next tutorial in the Learning Center or the next slide in a presentation. The other toolbar buttons are explained on the pages that follow.
There are several interactive tutorials available in the Learning Center. Click the Play button to go to the next 5-2 ICONICS
GenDemo
tutorial, or click the Carousel button (shown here on the left) to open the carousel to choose a tutorial from the playlist. The names of files in the playlist give you some indication of the content of each interactive tutorial. For example, some tutorials focus on 2-dimensional graphics tools and other on 3-dimensional ones; the file names contain the cues 2D and 3D so you can distinguish between them.
ICONICS
5-3
GenDemo
Merged playlist of all presentations. Note that when you first launch GenDemo, all of the presentations are merged into one playlist, and you can view the merged playlist simply by clicking the Play button. (To view the merged playlist, click the Carousel button.) However, once you select an individual presentation, the playlist is limited to slides for just that one presentation. To return to the merged playlist of all presentations, click the ICONICS icon in the top left corner of GenDemo (shown here on the right), then select Home from the menu that pops up. (Note that from the ICONICS logo you can also launch the ICONICS web site and a page that tells you more about ICONICS, Inc.)
5-4
ICONICS
GenDemo
The Industry Case Studies screen, shown below, is loaded with interactive case studies for the multiple industries that utilize ICONICS products, including utilities, food and drug, oil and gas, transportation, and the public sector.
ICONICS
5-5
GenDemo
Clicking on an individual case study opens the animated model in its own window (see the example below).
Because the case study models are interactive, you can click on them and manipulate them. You can explore them thoroughly to see how they work. In addition to the models on the Case Studies page, there are icons denoting that PDF files are available with the model. If Adobe Reader is installed, you can click the PDF icon to open a brief that explains the model and helps you understand the case study.
5-6
ICONICS
Note: For complete information about any GENESIS64 product, please refer to the GENESIS64 Help, which you can launch from any GENESIS64 product.
6.2 GraphWorX64
GraphWorX64 is the GENESIS64 product you use to create graphical human-machine interfaces (HMIs). GraphWorX64 has dozens of tools with hundreds of parameters and combinations to create powerful, dynamic, and interactive images in two or three dimensions. Use the interactive tutorials in the GenDemo Learning Center (see the description on page 5-2) to explore the tools that are available to you in GraphWorX64. To launch GraphWorX64 from the Windows Start menu, select Programs > ICONICS > GENESIS64 > GraphWorX64 > GraphWorX64. GraphWorX64 has a number of examples available to you. To use them, while in GraphWorX64, select Open from the File menu and browse to the following directory: \Program Files\ICONICS\GENESIS64\GenDemo\. In this folder you will find subfolders with a name prefix of GWX_. Explore the folders and open example files to see what they offer.
ICONICS
6-1
6.3 AlarmWorX64
AlarmWorX64 is the alarm monitoring, logging, and reporting module in GENESIS64. AlarmWorX64 consists of: AlarmWorX64 Viewer Which you use to configure real-time alarms and attach them to alarm sources; display alarm notifications; make it easier to notice, respond, and acknowledge alarm conditions; and view historical alarms. AlarmWorX64 Server Receives data from OPCcompliant Data Access servers and performs alarm detection and reporting. AlarmWorX64 Logger Stores alarm data to a SQL database, which you can use for later replay.
To launch AlarmWorX64 from the Windows Start menu, select Programs > ICONICS > GENESIS64 > AlarmWorX64 > AlarmWorX64. AlarmWorX64 opens inside the Workbench. A presentation in GenDemo (see the description on page 5-3) provides an overview of AlarmWorX64. For a complete understanding of AlarmWorX64, access GENESIS64 online Help while in AlarmWorX64.
6.4 TrendWorX64
Use TrendWorX64 to plot real-time and historical OPC data into charts and graphs of all kinds, which you can then use as multifunctional HMI graphic displays. TrendWorX64 has a number of tools you can use to satisfy a wide range of applications. To launch TrendWorX64 from the Windows Start menu, select Programs > ICONICS > GENESIS64 > 6-2 ICONICS
TrendWorX64 > TrendWorX64. TrendWorX64 opens inside the Workbench. A presentation in GenDemo (see the description on page 5-3) provides an overview of TrendWorX64. For a complete understanding of TrendWorX64, access GENESIS64 online Help while in TrendWorX64.
6.5 EarthWorX
Use EarthWorX to incorporate drill-down technology to quickly view alarm conditions for any location around the world, using maps available with Microsoft Bing. EarthWorX helps you to visualize geographically-dispersed assets (such as factories, facilities, or job sites) and track movable objects using GPS coordinates. A presentation in GenDemo (see the description on page 5-3) provides an overview of EarthWorX. Instructions for using EarthWorX are available in GENESIS64 online Help.
6.6 Workbench
The Workbench is the centralized Web-based interface in which you open GENESIS64 products and configure GENESIS64 components, runtime, and security. Every GENESIS64 component can be loaded, worked with, and run inside the Workbench. Projects can be packaged and deployed from inside the Workbench, too. When you select the Workbench command from the Windows Start menu the Workbench loads with all of the applications showing in the Project Explorer. It swaps in functions with each GENESIS64 product that you load in it.
ICONICS
6-3
6-4
ICONICS
GENESIS64 Getting Started GENESIS64 providers can be opened from within the Project Explorer in the Workbench. To launch the Workbench from the Windows Start menu, select Programs > ICONICS > Workbench. A presentation in GenDemo (described on page 5-3) provides an overview of the Workbench. For a complete understanding of the Workbench, access GENESIS64 online Help while in the Workbench.
ICONICS
6-5
Use Global Aliasing to set up aliases for use across GENESIS64 products. Click Start > Programs > ICONICS GENESIS64 > Tools > Global Aliasing. Use Security to restrict operator and workstation runtime access. Privileges can be granted by a number of means, including application action, points, alarms, files, stations, and custom strings. To work with security, click Start > Programs > ICONICS GENESIS64 > Tools > Security. TraceWorX provides online diagnostics and tuning of applications running in GENESIS64. TraceWorX is intended for use by systems integrators, OEMs and customers who want to have tools for doing their own troubleshooting and diagnostics. To work with TraceWorX, click Start > Programs > ICONICS GENESIS64 > Tools > TraceWorX. Save implementation and development time by using the Unified Data Manager (UDM) to create libraries of reusable expressions, value sets, tag groups, alarm subscriptions, alarm filters, recipes, and event triggers across ICONICS products. To work with the UDM, click Start > Programs > ICONICS GENESIS64 > Tools > Unified Data Manager. Use the SNMP Connector to create, monitor, and manage your own Network Management Systems through GENESIS64, giving Network Managers access to information from nearly every device connected to the network, all from one application. To work with the SNMP Connector, click its button or icon in the Project Explorer in the Workbench. Use the ICONICS BACnet Connector to integrate BACnet communications into the GENESIS64 and GENESIS32/Workbench32 product families. To work with the BACnet Connector, click its button or icon in the Project Explorer in the Workbench.
6-6
ICONICS
icon in the Workbench. This opens Click the Help the help file for that application. To search for a topic in the help file, click the Index tab or the Search tab. Type or select the term you want to find, and then click the topic you want to read. Press the F1 key to display context-sensitive help. Click the Help button in any dialog box to display context-sensitive help for that dialog box. Move the mouse pointer over an icon and pause for a moment to display pop-up ToolTips for quick help.
ICONICS
7-1
7-2
ICONICS
7.4.3
Online Support ICONICS maintains a comprehensive Web site at http://www.iconics.com. This is the best place to go for the latest events, support information, product downloads, licensing, documentation, services, and product news. Note. Software obtained from ICONICS.com is subject to the ICONICS License Agreement.
7.4.4
Telephone Support ICONICS support centers are open Monday through Friday, year round, except for local holidays and ICONICS holidays. Support handles calls on a first-come, first-served basis. Calls are answered immediately during the business hours below. Americas (United States): 508-543-8600 Europe (Czech Republic): 420-377-183-447 Asia Pacific (Australia): 61-297-273-411 8:00 AM 6:00 PM Eastern Standard Time 9:00 AM 6:00 PM European Central Time 9:00 AM 6:00 PM Australian Eastern Time
Please have the following available when you call: Your SupportWorX Plan Number Your GENESIS64 Registration or Serial Number A PC available for tests and diagnostics A clear understanding about the issue. The version of your OS and the ICONICS product(s) OPC server or relevant third-party software info
ICONICS
7-3
The ICONICS support center e-mail addresses are: North America: Support@ICONICS.com Europe: EuropeSupport@ICONICS.com Pacific Rim: PacificRimSupport@ICONICS.com
Please include your SupportWorX Plan Number and Product Registration Number or Serial Number when sending your message. E-mail requests will be answered on a first-come, first-served basis, typically on the same day (up to three
7-4
ICONICS
NOTES
ICONICS
7-5
ICONICS, Inc.
100 Foxborough Blvd., Foxborough, MA 02035 508.543.8600 FAX 508.543.1503 www.iconics.com E-mail info@iconics.com 2011 ICONICS, Inc. All rights reserved. Specifications subject to change without notice
ICONICS