Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

CERN Document Server 2,050 записей найдено  1 - 10следующийконец  перейти к записи: Поиск длился 0.53 секунд. 
1.
Different versions of Cryogenic Current Comparators with magnetic core for beam current measurements / Golm, Jessica (Jena U. ; Helmholtz Inst., Jena) ; De Gersem, Herbert (Darmstadt, Tech. U.) ; Fernandes, Miguel (CERN ; Cockcroft Inst. Accel. Sci. Tech. ; Liverpool U.) ; Haider, David (Darmstadt, GSI) ; Kurian, Febin (Darmstadt, GSI) ; Marsic, Nicolas (Darmstadt, Tech. U.) ; Müller, Wolfgang (Darmstadt, Tech. U.) ; Neubert, Ralf (Jena U. ; TLS, Tautenburg) ; Schmelz, Matthias (Inst. Photonic Tech., Jena) ; Schmidl, Frank (Jena U.) et al.
For more than 20 years Cryogenic Current Comparators (CCC) are used to measure the current of charged particle beams with low intensity (nA-range). The device was first established at GSI in Darmstadt and was improved over the past two decades by the cooperation of institutes in Jena, GSI and CERN. [...]
CERN-ACC-2019-230.- 2019 - 4 p. - Published in : 10.18429/JACoW-IPAC2019-THYYPLS2 Fulltext from publisher: PDF;
In : 10th International Particle Accelerator Conference, Melbourne, Australia, 19 - 24 May 2019, pp.THYYPLS2
2.
Beam Intensity Monitoring with nA Resolution - the Cryogenic Current Comparator (CCC) / Haider, David (Darmstadt, GSI) ; De Gersem, Herbert (Darmstadt, Tech. Hochsch.) ; Fernandes, Miguel (CERN) ; Forck, Peter (Darmstadt, GSI) ; Golm, Jessica (Unlisted, DE) ; Kurian, Febin (Darmstadt, GSI) ; Marsic, Nicolas (Darmstadt, Tech. Hochsch.) ; Schmelz, Matthias (Inst. Photonic Tech., Jena) ; Schmidl, Frank (Unlisted, DE) ; Schwickert, Marcus (Darmstadt, GSI) et al.
The storage of low current beams as well as the long extraction times from the synchrotrons at FAIR require non-destructive beam intensity monitoring with a current resolution of nanoampere. To fulfill this requirement, the concept of the Cryogenic Current Comparator (CCC), based on the low temperature SQUID, is used to obtain an extremely sensitive beam current transformer. [...]
JACoW, 2019 - 4 p. - Published in : 10.18429/JACoW-IBIC2018-MOPC08 Published fulltext: PDF;
In : 7th International Beam Instrumentation Conference, Shanghai, China, 9 - 13 Sep, 2018, pp.MOPC08
3.
Cryogenic Current Comparators as Low Intensity Diagnostics for Ion Beams / Sieber, Thomas (Darmstadt, GSI) ; Crescimbeni, Lorenzo (U. Jena (main) ; Darmstadt, GSI) ; Haider, David (Darmstadt, GSI) ; Marsic, Nicolas (Denmark, Tech. U.) ; Schmelz, Matthias ; Schmidl, Frank (U. Jena (main)) ; Schwickert, Marcus ; Stöhlker, Thomas (Helmholtz Inst., Jena ; Darmstadt, GSI) ; Stolz, Ronny (Ilmenau Tech. U.) ; Tan, Jocelyn (CERN) et al.
The Cryogenic Current Comparator (CCC) is a SQUID based superconducting device for intensity measurement, firstly proposed as a beam diagnostics instrument in the 90s at GSI. After prove of principle the CCC was introduced into other facilities, attesting great potential for high resolution measurements but at the same time considerable mechanical and cryogenics challenges and costs. [...]
2023 - 5 p. - Published in : JACoW IBIC 2023 (2023) TUP036 Fulltext: PDF;
In : 12th International Beam Instrumentation Conference (IBIC 2023), Saskatoon, Canada, 10 - 14 Sep 2023, pp.TUP036
4.
Optimization of the Cryogenic Current Comparator (CCC) for Beam Intensity Measurement / Sieber, Thomas (Darmstadt, GSI) ; De Gersem, Herbert (Darmstadt, Tech. Hochsch.) ; Fernandes, Miguel (CERN ; Liverpool U.) ; Golm, Jessica (Unlisted, DE) ; Jones, Robert (CERN) ; Kowina, Piotr (Darmstadt, GSI) ; Kurian, Febin (Darmstadt, GSI) ; Marsic, Nicolas (Darmstadt, Tech. Hochsch.) ; Neubert, Ralf (Unlisted, DE) ; Reeg, Hansjörg (Darmstadt, GSI) et al.
Triggered by the need for current measurement in the nA range for slow extracted beams and for the beams in the storage rings at FAIR and CERN, the idea of the CCC as a current transformer has been revitalized during the last ten years. Compared to the first prototype, developed at GSI in the 90s, the second generation of CCCs is based on the possibility of detailed simulation of superconducting magnetic shielding properties, new nano-crystalline materials for the magnetic ring-cores, and on superior commercially available SQUID systems. [...]
2018 - 4 p. - Published in : 10.18429/JACoW-IBIC2017-TH2AB3 Fulltext: PDF;
In : 6th International Beam Instrumentation Conference, Grand Rapids, MI, USA, 20 -24 Aug 2017, pp.TH2AB3
5.
Comparative Measurement and Characterisation of Three Cryogenic Current Comparators Based on Low-Temperature Superconductors / Tympel, Volker (Helmholtz Inst., Jena) ; De Gersem, Herbert (Darmstadt, Tech. Hochsch.) ; Fernandes, Miguel (Cockcroft Inst. Accel. Sci. Tech. ; CERN ; U. Liverpool (main)) ; Golm, Jessica (U. Jena (main)) ; Haider, David (Darmstadt, GSI) ; Kurian, Febin (Darmstadt, GSI) ; Marsic, Nicolas (Darmstadt, Tech. Hochsch.) ; Müller, Wolfgang (Darmstadt, Tech. Hochsch.) ; Neubert, Ralf (U. Jena (main) ; TLS, Tautenburg) ; Schmelz, Matthias (Inst. Photonic Tech., Jena) et al.
A Cryogenic Current Comparator (CCC) is a non-destructive, metrological-traceable charged particle beam intensity measurement system for the nano-ampere range. Using superconducting shielding and coils, low temperature Superconducting Quantum Interference Devices (SQUIDs) and highly permeable flux-concentrators, the CCC can operate in the frequency range from DC to several kHz or hundreds of kHz depending on the requirement of the application. [...]
JACoW, 2019 - 4 p. - Published in : 10.18429/JACoW-IBIC2018-MOPC06 Published fulltext: PDF;
In : 7th International Beam Instrumentation Conference, Shanghai, China, 9 - 13 Sep, 2018, pp.MOPC06
6.
First Measurements of a New Type of Coreless Cryogenic Current Comparators (4C) for Non-Destructive Intensity Diagnostics of Charged Particles / Tympel, Volker (Helmholtz Inst., Jena) ; Anders, Solveig (Inst. Photonic Tech., Jena) ; De Gersem, Herbert (Darmstadt, Tech. U.) ; Golm, Jessica (Jena U.) ; Haider, David (Darmstadt, GSI) ; Kunert, Juergen (Inst. Photonic Tech., Jena) ; Marsic, Nicolas (Darmstadt, Tech. U.) ; Müller, Wolfgang (Darmstadt, Tech. U.) ; Schmelz, Matthias (Inst. Photonic Tech., Jena) ; Schmidl, Frank (Darmstadt, GSI) et al.
The non-destructive and highly sensitive measurement of a charged particle beam is of utmost importance for modern particle accelerator facilities. A Cryogenic Current Comparator (CCC) can be used to measure beam currents in the nA-range. [...]
2019 - 3 p. - Published in : 10.18429/JACoW-IBIC2019-MOPP008 Fulltext: PDF;
In : 8th International Beam Instrumentation Conference (IBIC 2019), Malmo, Sweden, 8 - 12 Sep 2019, pp.MOPP008
7.
Next generation Cryogenic Current Comparator (CCC) for nA intensity measurement / Sieber, Thomas (Darmstadt, GSI) ; De Gersem, Herbert (Darmstadt, Tech. U.) ; Golm, Jessica (U. Jena (main)) ; Haider, David (Darmstadt, GSI) ; Marsic, Nicolas (Darmstadt, Tech. U.) ; Müller, Wolfgang (Darmstadt, Tech. U.) ; Reeg, Hansjörg (Darmstadt, GSI) ; Schmelz, Matthias (Inst. Photonic Tech., Jena) ; Schmidl, Frank (U. Jena (main)) ; Schwickert, Marcus (Darmstadt, GSI) et al.
A Cryogenic Current Comparator (CCC) is an extremely sensitive DC-Beam Transformer based on superconducting SQUID technology. Recently, a CCC without a toroidal core and with an axially oriented magnetic shielding has been developed at the Institute of Photonic Technologies (IPHT) Jena/Germany. [...]
CERN-ACC-2019-193.- 2019 - 4 p. - Published in : 10.18429/JACoW-IPAC2019-WEPGW020 Fulltext from publisher: PDF;
In : 10th International Particle Accelerator Conference, Melbourne, Australia, 19 - 24 May 2019, pp.WEPGW020
8.
Versatile Beamline Cryostat for the Cryogenic Current Comparator (CCC) for FAIR / Haider, David (Darmstadt, GSI) ; De Gersem, Herbert (Darmstadt, Tech. U.) ; Golm, Jessica (Jena U. ; CERN) ; Koettig, Torsten (CERN) ; Kurian, Febin (Darmstadt, GSI) ; Marsic, Nicolas (Darmstadt, Tech. U.) ; Müller, Wolfgang (Darmstadt, Tech. U.) ; Schmelz, Matthias ; Schwickert, Marcus (Darmstadt, GSI) ; Sieber, Thomas (Darmstadt, GSI) et al.
The Cryogenic Current Comparator (CCC) extends the measurement range of traditional non-destructive current monitors used in accelerator beamlines down to a few nano-amperes of direct beam current. This is achieved by a cryogenic environment of liquid helium around the beamline, in which the beam’s magnetic field is measured with a Superconducting Quantum Interference Device (SQUID), which is itself enclosed in a superconducting shielding structure. [...]
2019 - 4 p. - Published in : 10.18429/JACoW-IBIC2019-MOPP007 Fulltext: PDF;
In : 8th International Beam Instrumentation Conference (IBIC 2019), Malmo, Sweden, 8 - 12 Sep 2019, pp.MOPP007
9.
Cryogenic Current Comparator for Storage Rings and Accelerators / Geithner, Rene (Helmholtz Inst., Jena ; Jena U.) ; Fernandes, Miguel (CERN ; Cockcroft Inst. Accel. Sci. Tech. ; Liverpool U.) ; Kurian, Febin (Darmstadt, GSI) ; Neubert, Ralf (Jena U.) ; Reeg, Hansjörg (Darmstadt, GSI) ; Schwickert, Marcus (Darmstadt, GSI) ; Seidel, Paul (Jena U.) ; Sieber, Thomas (Darmstadt, GSI) ; Stöhlker, Thomas (Darmstadt, GSI ; Helmholtz Inst., Jena ; Jena U.)
A Cryogenic Current Comparator (CCC) was developed for a non-destructive, highly sensitive monitoring of nA beams at the planned FAIR accelerator facility at GSI. The sensor part of the CCC was optimized for lowest possible noise-limited current resolution in combination with a high system bandwidth of about 200 kHz. [...]
2016 - 5 p. - Published in : 10.18429/JACoW-IBIC2015-MOPB013 Fulltext: PDF;
In : International Beam Instrumentation Conference , Melbourne, Australia, 13 - 17 Sep 2015, pp.MOPB013
10.
Superconducting beam charge monitors for antiproton storage rings / Tympel, Volker (Jena U.) ; Neubert, Ralf (Jena U.) ; Seidel, Paul (Jena U.) ; Geithner, René (Jena U. ; Helmholtz Inst., Jena) ; Golm, Jessica (Jena U. ; Helmholtz Inst., Jena) ; Stöhlker, Thomas (Jena U. ; Helmholtz Inst., Jena ; Darmstadt, GSI) ; Kurian, Febian (Jena U. ; Helmholtz Inst., Jena ; Darmstadt, GSI) ; Sieber, Thomas (Darmstadt, GSI) ; Schwickert, Marcus (Darmstadt, GSI) ; Fernandes, Miguel (Cockcroft Inst. Accel. Sci. Tech. ; Liverpool U. ; CERN)
A Cryogenic Current Comparator (CCC) is a new type of instruments for monitoring charged beams like ions or antiprotons. Using superconducting effects is it possible to create a nondestructive, contactless and easy to calibrate beam measurement system with a high current resolution in amplitude and time. [...]
2017 - 6 p. - Published in : JPS Conf. Proc. 18 (2017) 011042 Fulltext: PDF;
In : 12th International Conference on Low Energy Antiproton Physics, Kanazawa, Japan, 6 - 11 Mar 2016, pp.011042

не нашли то, что искали? Попробуйте поискать на других серверах
recid:2693140 в Amazon
recid:2693140 в CERN EDMS
recid:2693140 в CERN Intranet
recid:2693140 в CiteSeer
recid:2693140 в Google Books
recid:2693140 в Google Scholar
recid:2693140 в Google Web
recid:2693140 в IEC
recid:2693140 в IHS
recid:2693140 в INSPIRE
recid:2693140 в ISO
recid:2693140 в KISS Books/Journals
recid:2693140 в KISS Preprints
recid:2693140 в NEBIS
recid:2693140 в SLAC Library Catalog