The magnetic quadrupole pick-ups in the CERN PS / Jansson, A
The idea of using non-linearities of beam position monitors to measure the second moment sx2 - sy2 of the transverse beam distribution is almost as old as the synchrotron. However, although a few successful experiments have been reported, the method has not become widely accepted. [...]
CERN-PS-2002-050-OP.- Geneva : CERN, 2002 - 17 p. - Published in : AIP Conf. Proc. 648 (2002) 3-18 Access to fulltext document: PDF;
In : 10th Beam Instrumentation Workshop, Upton, NY, USA, 6 - 9 May 2002, pp.3-18 - Please contact the library if you need to access this document.
2.
Non-Invasive Measurement of Emittance and Optical Parameters for High-Brightness Hadron Beams in a Synchrotron / Jansson, A
For hadron colliders, such as the Large Hadron Collider at CERN, emittance preservation is of prime importance to achieve a high luminosity [...]
CERN-THESIS-2001-032 CERN-PS-2001-014-OP. - Geneva : CERN, 2001. - 122 p.

3.
Design of a Magnetic Quadrupole Pick-up for the CERN PS / Jansson, A ; Søby, L ; Williams, D J
A quadrupole pick-up is sensitive to the quantity $\sigma_x^2 - \sigma_y^2$ where $\sigma_x$ and /sigma_y$ are the horizontal and vertical r.m.s. beam sizes. [...]
CERN-PS-2001-048-BD.- Geneva : CERN, 2001 - 4 p. Access to fulltext document: PDF; External link: Published version from JACoW
In : 5th European Workshop on Diagnostics and Beam Instrumentation, Grenoble, France, 13 - 15 May 2001, pp.108 - Please contact the library if you need to access this document.
4.
A magnetic quadrupole pick-up for the CERN PS / Chapman-Hatchett, A ; Jansson, A ; Williams, D J
In the LHC era, there will be a need to monitor and correct betatron mismatch between machines in a non-destructive way. For this purpose, a quadrupole pick-up has been designed for the CERN PS. [...]
CERN-PS-99-030-OP.- Geneva : CERN, 1999 - 7 p. Fulltext: PDF; IEEE Published version, local copy: PDF;
In : 18th Biennial Particle Accelerator Conference, New York, NY, USA, 29 Mar - 2 Apr 1999, pp.2223-2225 - Please contact the library if you need to access this document.
5.
A New Optimised Quadrupole Pick-up Design Using Magnetic Coupling / Jansson, A ; Williams, D J
The idea of quadrupole pick-ups, sensitive to beam size, dates back several decades. Such pick-ups measure the quantity $\sigma^2_x-\sigma^2_y$, where $\sigma_x$ and $\sigma_y$ are the horizontal and vertical r.m.s. [...]
CERN-PS-2000-073-OP rev.- Geneva : CERN, 2002 - 26 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 479 (2002) 233-42 Access to fulltext document: PDF; - Please contact the library if you need to access this document.
6.
A Non-Invasive Single-Bunch Matching and Emittance Monitor for the CERN PS Based on Quadrupole Pick-Ups / Jansson, A ; Søby, L
On-line monitoring of beam quality for high brightness beams is only possible using non-invasive instruments. For matching measurements, very few such instruments are available. [...]
CERN-PS-2001-026-OP.- Geneva : CERN, 2001 - 4 p. Fulltext: PDF; IEEE Published version, local copy: PDF;
In : 19th IEEE Particle Accelerator Conference, Chicago, IL, USA, 18 - 22 Jun 2001, pp.e-proc. 528 - Please contact the library if you need to access this document.
7.
Non-invasive single-bunch matching and emittance monitor / Jansson, A (CERN)
On-line monitoring of beam quality for high brightness beams is only possible using non-invasive instruments. For matching measurements, very few such instruments are available. [...]
physics/0202057; CERN-PS-2002-049-OP.- Geneva : CERN, 2002 - 11 p. APS Published version, local copy: PDF; Access to fulltext document: PDF; - Please contact the library if you need to access this document.
8.
The high frequency longitudinal and transverse pick-ups used in the SPS / Linnecar, Trevor Paul R
Part I of this report describes the various wideband longitudinal and transverse pick-ups which are used in the SPS for beam observation [...]
CERN-SPS-ARF-78-17. - Geneva, 1978. - 99 p.

9.
A non-invasive single-bunch matching and emittance monitor for the CERN PS based on quadrupole pick-ups / Jansson, A ; Søby, L
CERN-PS-2001-026-OP.- Geneva : CERN, 2001 - 4 p. Fulltext: PDF;
10.
The measurement of higher order moments of beam transverse distribution using a magnetic pick-up / Jansson, A
CERN-PS-OP-Note-98-27.- Geneva : CERN, 1998 - 11 p. Fulltext: PDF;

ვერ იპოვნეთ რასაც ეძებდით? სცადეთ თქვენი ძებნა სხვა სერვერებზე:
recid:572118 ში Amazon
recid:572118 ში CERN EDMS
recid:572118 ში CERN Intranet
recid:572118 ში CiteSeer
recid:572118 ში Google Books
recid:572118 ში Google Scholar
recid:572118 ში Google Web
recid:572118 ში IEC
recid:572118 ში IHS
recid:572118 ში INSPIRE
recid:572118 ში ISO
recid:572118 ში KISS Books/Journals
recid:572118 ში KISS Preprints
recid:572118 ში NEBIS
recid:572118 ში SLAC Library Catalog