Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

CERN Document Server Намерени са 2,032 записа  1 - 10следващкрай  отиване на запис: Търсенето отне 0.58 секунди. 
1.
Quality control of ATLAS muon chambers / Fabich, Adrian
ATLAS is a general-purpose experiment for the future Large Hadron Collider (LHC) at CERN [...]
CERN-THESIS-99-078 - 54 p.

Fulltext
2.
The Freiburg MDT leak test setup / Landgraf, U ; Mohr, W ; Zimmermann, S
This note descibes the setup at the university of Freiburg for verifying the gas tightness of the Atlas MDTs after their production, as required by the Atlas muon community QA/QC procedure. [...]
ATL-MUON-2000-022.
- 2000. - 12 p.
Access to fulltext document - Access to fulltext document
3.
ATLAS Monitored Drift Tube assembly and test / Qi Chun Xu ; Bing Zhou
The Monitored Drift Tube (MDT) is the basic element of the ATLAS muon detector at the Large Hadron Collider (LHC). More than 400 long MDTs have been constructed and tested at the University of Michigan for Module 0 of the ATLAS end-cap muon chambers. [...]
2000
In : 47th IEEE Nuclear Science Symposium and Medical Imaging Conference, Lyons, France, 15 - 20 Oct 2000, pp.5/96-100 (v.1)
4.
Construction and Test of Muon Drift Tube Chambers for High Counting Rates / Schwegler, Philipp
Since the start of operation of the Large Hadron Collider (LHC) at CERN on 20 November 2009, the instantaneous luminosity is steadily increasing [...]
CERN-THESIS-2010-188 MPP-2010-184. - München : Munich, Max Planck Inst., 2010. - 89 p.

Fulltext
5.
A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes / Alexopoulos, T (Natl. Tech. U., Athens) ; Avramidou, R ; Dris, M ; Filippas-Tassos, A ; Gazis, E N ; Katsoufis, E C ; Maltezos, S ; Savva, Panagiota S ; Stavropoulos, G D ; Tsipolitis, G
A low-cost, reliable and precise system developed for the gas leak rate measurement of the BIS-Monitored Drift Tubes (MDTs) for the ATLAS Muon Spectrometer is presented. In order to meet the BIS-MDT mass production rate, a total number of 100 tubes are tested simultaneously in this setup. [...]
SN-ATLAS-2002-016; ATL-COM-MUON-2001-024.- Geneva : CERN, 2004 - 18 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 521 (2004) 332-342 Access to fulltext document: sn-atlas-2002-016 - PDF; sn-atlas-2002-016_final_decision - TXT;
6.
Drift properties of Monitored Drift Tubes chambers of the ATLAS Muon Spectrometer / Cirilli, M
The ATLAS Muon Spectrometer relies on Monitored Drift Tube (MDT) chambers for precision tracking of muons. Variations in the properties of the gas mixture have important effects on the detector performance. [...]
2004 - Published in : Nucl. Instrum. Methods Phys. Res., A 518 (2004) 62-64
7.
ATLAS monitored drift tube assembly and test / Xu Qi Chun ; Zhou Bing
The Monitored Drift Tube (MDT) is the basic element of the ATLAS muon detector at the Large Hadron Collider (LHC). More than 400 long MDTs have been constructed and tested at the University of Michigan for Module 0 of the ATLAS end-cap muon chambers. [...]
2000
In : 47th IEEE Nuclear Science Symposium and Medical Imaging Conference, Lyons, France, 15 - 20 Oct 2000, pp.5/96-5/100 (v.1)
8.

CERN-EX-0208006
© 2002-2024 CERN
Monitored Drift Tube (MDT) chambers for precise measurement of muon trajectories in the ATLAS muon spectrometer.
The basic detection component of the chamber is th [...]
07 Aug 2002
9.
High-precision spectroscopy with the ATLAS muon system / Aleksa, Martin ; Fabjan, Christian Wolfgang ; Riegler, W
The ATLAS muon spectrometer will measure muon tracks along a spectrometer arm of up to 15 m length, embedded in a magnetic field of ~0.5 T. The precision tracking devices in the muon system will be high-pressure drift tubes (MDTs). [...]
Geneva : CERN, 2001 - Published in : Nucl. Instrum. Methods Phys. Res., A 461 (2001) 55-6
10.
Drift velocity and pressure monitoring of the CMS muon drift chambers / Sonnenschein, Lars (Aachen, Tech. Hochsch.)
The drift velocity in drift tubes of the CMS muon chambers is a key parameter for the muon track reconstruction and trigger. [...]
arXiv:1107.0358.
- 2011. - 3 p.
Preprint - Full text

Не намерихте, каквото търсите? Опитайте търсене в други сървъри:
recid:1463542 в Amazon
recid:1463542 в CERN EDMS
recid:1463542 в CERN Intranet
recid:1463542 в CiteSeer
recid:1463542 в Google Books
recid:1463542 в Google Scholar
recid:1463542 в Google Web
recid:1463542 в IEC
recid:1463542 в IHS
recid:1463542 в INSPIRE
recid:1463542 в ISO
recid:1463542 в KISS Books/Journals
recid:1463542 в KISS Preprints
recid:1463542 в NEBIS
recid:1463542 в SLAC Library Catalog