Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

CERN Document Server 找到 2,048 笔记录  1 - 10下一个最後  跳到记录: 检索需时 2.17 秒. 
1.
Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade / Abbas, Syed Mohsin (IPM, Tehran) ; Abbrescia, Marcello (INFN, Bari ; Bari U.) ; Abdalla, Hassan Fathy (Cairo, Acad. Sci. Res. Tech.) ; Abdelalim, Ahmed Ali (Cairo, Acad. Sci. Res. Tech.) ; Abuzeid Hassan, Shimaa Abdelwahed (INFN, Pavia) ; Agapitos, Antonis (Peking U.) ; Ahmad, Ashfaq (Quaid-i-Azam U.) ; Ahmed, Asar (Delhi U.) ; Ahmed, Waqar (Quaid-i-Azam U.) ; Aimè, Chiara (INFN, Pavia ; Pavia U.) et al.
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. [...]
CMS-NOTE-2022-004; CERN-CMS-NOTE-2022-004.- Geneva : CERN, 2022 - 47 p. Fulltext: PDF;
2.
Production and validation of industrially produced large-sized GEM foils for the Phase-2 upgrade of the CMS muon spectrometer / Abbas, Syed Mohsin (IPM, Tehran) ; Abbrescia, Marcello (INFN, Bari ; Bari U.) ; Abdalla, Hassan Fathy (Cairo, Acad. Sci. Res. Tech.) ; Abdelalim, Ahmed Ali (Cairo, Acad. Sci. Res. Tech.) ; Abuzeid Hassan, Shimaa Abdelwahed (INFN, Pavia) ; Aebi, Devin Michael (Texas A-M) ; Agapitos, Antonis (Peking U.) ; Ahmad, Ashfaq (Quaid-i-Azam U.) ; Ahmed, Asar (Delhi U.) ; Ahmed, Waqar (Quaid-i-Azam U.) et al.
The upgrade of the CMS detector for the high luminosity LHC (HL-LHC) will include gas electron multiplier (GEM) detectors in the end-cap muon spectrometer. Due to the limited supply of large area GEM detectors, the Korean CMS (KCMS) collaboration had formed a consortium with Mecaro Co., Ltd. to serve as a supplier of GEM foils with area of approximately 0.6 m$^{2}$. The consortium has developed a double-mask etching technique for production of these large-sized GEM foils. This article describes the production, quality control, and quality assessment (QA/QC) procedures and the mass production status for the GEM foils. [...]
CMS-NOTE-2023-006; CERN-CMS-NOTE-2023-006.- Geneva : CERN, 2023 - 18 p. Fulltext: PDF;
3.
A novel application of Fiber Bragg Grating (FBG) sensors in MPGD / CMS Collaboration
We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. [...]
arXiv:1512.08529; INFN-15-10-LNF; CMS-CR-2015-363.- 2018 - 4 p. - Published in : EPJ Web Conf. 174 (2018) 03002 Fulltext: epjconf_mpgd2018_03002 - PDF; CR2015_363 - PDF; arXiv:1512.08529 - PDF; External link: Preprint
In : 4th International Conference on Micro Pattern Gaseous Detectors - MPGD2015, Trieste, Italy, 12 - 15 Oct 2015, pp.03002
4.
Quality control and beam test of GEM detectors for future upgrades of the CMS muon high rate region at the LHC / Abbaneo, D (CERN) ; Abbas, M (CERN) ; Abbrescia, M (Bari Polytechnic ; Bari U. ; INFN, Bari) ; Abdelalim, A A (British U. in Egypt) ; Akl, M Abi (Texas A&M; U. Qatar, Doha) ; Ahmed, W (British U. in Egypt) ; Ahmed, W (Quaid-i-Azam U.) ; Altieri, P (Bari Polytechnic ; Bari U. ; INFN, Bari) ; Aly, R (British U. in Egypt) ; Armaingaud, C (Aachen, Tech. Hochsch.) et al.
Gas Electron Multipliers (GEM) are a proven position sensitive gas detector technology which nowadays is becoming more widely used in High Energy Physics. GEMs offer an excellent spatial resolution and a high particle rate capability, with a close to 100% detection efficiency. [...]
2015 - 12 p. - Published in : JINST 10 (2015) C03039 Fulltext: PDF;
In : 10th International Conference on Position Sensitive Detectors, Surrey, UK, 7 - 12 Sep 2014, pp.C03039
5.
Upgrade of the CMS muon system with triple-GEM detectors / Abbaneo, D (CERN) ; Abbas, M (CERN) ; Abbrescia, M (Bari Polytechnic ; Bari U. ; INFN, Bari) ; Abdelalim, A A (British U. in Egypt) ; Akl, M Abi (Texas A&M; U. Qatar, Doha) ; Ahmed, W (British U. in Egypt) ; Ahmed, W (Quaid-i-Azam U.) ; Altieri, P (Bari Polytechnic ; Bari U. ; INFN, Bari) ; Aly, R (British U. in Egypt) ; Ashfaq, A (Quaid-i-Azam U.) et al.
The CMS collaboration considers upgrading the muon forward region which is particularly affected by the high-luminosity conditions at the LHC. The proposal involves Gas Electron Multiplier (GEM) chambers, which are able to handle the extreme particle rates expected in this region along with a high spatial resolution. [...]
2014 - 10 p. - Published in : JINST 9 (2014) C10036
In : International Conference on Instrumentation for Colliding Beam Physics 2014, Novosibirsk, Russia, 24 Feb - 1 Mar 2014, pp.C10036
6.
Triple-GEM discharge probability studies at CHARM: simulations and experimental results / CMS Muon Group Collaboration
The CMS muon system in the region with 2.03<|η|<2.82 is characterized by a very harsh radiation environment which can generate hit rates up to 144 kHz/cm2 and an integrated charge of 8 C/cm2 over ten years of operation. In order to increase the detector performance and acceptance for physics events including muons, a new muon station (ME0) has been proposed for installation in that region. [...]
2020 - 23 p. - Published in : JINST 15 (2020) P10013 Fulltext: PDF;
7.
Performance of Resistive Plate Chambers installed during the first long shutdown of the CMS experiment / Shopova, M. (Budapest, RMKI) ; Aleksandrov, A. (Sofiya, Inst. Nucl. Res.) ; Hadjiiska, R. (Sofiya, Inst. Nucl. Res.) ; Iaydjiev, P. (Sofiya, Inst. Nucl. Res.) ; Sultanov, G. (Sofiya, Inst. Nucl. Res.) ; Rodozov, M. (Sofiya, Inst. Nucl. Res.) ; Stoykova, S. (Sofiya, Inst. Nucl. Res.) ; Assran, Y. (British U. in Egypt ; Cairo, Acad. Sci. Res. Tech. ; Suez Canal U.) ; Sayed, A. (Cairo, Acad. Sci. Res. Tech.) ; Radi, A. (Ain Shams U., Cairo ; British U. in Egypt ; Cairo, Acad. Sci. Res. Tech.) et al.
The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). [...]
arXiv:1605.06798 ; CMS-CR-2016-090 ; CMS-CR-2016-090.
- 2016. - 7 p.
Preprint - Full text
8.
Search for pair production of vector-like quarks in the bW$\overline{\mathrm{b}}$W channel from proton-proton collisions at $\sqrt{s} =$ 13 TeV / CMS Collaboration
A search is presented for the production of vector-like quark pairs, T$\overline{\mathrm{T}}$ or Y$\overline{\mathrm{Y}}$, with electric charge of 2/3 (T) or -4/3 (Y), in proton-proton collisions at $\sqrt{s} =$ 13 TeV. The data were collected by the CMS experiment at the LHC in 2016 and correspond to an integrated luminosity of 35.8 fb$^{-1}$. [...]
arXiv:1710.01539; CMS-B2G-17-003; CERN-EP-2017-224.- Geneva : CERN, 2018-04-10 - 25 p. - Published in : Phys. Lett. B 779 (2018) 82-106 Article from SCOAP3: PDF; Fulltext: PDF; External links: Additional information for the analysis; CMS AuthorList
9.
Detector Control System for the GE1/1 slice test / Abbas, M (KIT, Karlsruhe) ; Abbrescia, M (Bari Polytechnic ; Bari U. ; INFN, Bari) ; Abdalla, H (Cairo, Acad. Sci. Res. Tech.) ; Zeid, S Abu (Cairo, Acad. Sci. Res. Tech.) ; Agapitos, A (Peking U.) ; Ahmad, A (NCP, Islamabad) ; Ahmed, A (Cairo, Acad. Sci. Res. Tech.) ; Ahmed, A (Delhi U.) ; Ahmed, W (NCP, Islamabad) ; Amarjeet, S (Panjab U.) et al.
Gas Electron Multiplier (GEM) technology, in particular triple-GEM, was selected for the upgrade of the CMS endcap muon system following several years of intense effort on R&D.; The triple-GEM chambers (GE1/1) are being installed at station 1 during the second long shutdown with the goal of reducing the Level-1 muon trigger rate and improving the tracking performance in the harsh radiation environment foreseen in the future LHC operation [1]. A first installation of a demonstrator system started at the beginning of 2017: 10 triple-GEM detectors were installed in the CMS muon system with the aim of gaining operational experience and demonstrating the integration of the GE1/1 system into the trigger. [...]
2020 - 19 p. - Published in : JINST 15 (2020) P05023 Fulltext: PDF;
10.
Quality control for the first large areas of triple-GEM chambers for the CMS endcaps / CMS Collaboration
The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D; and moving to production. [...]
CMS-CR-2015-347.- Geneva : CERN, 2015 - 5 p. - Published in : EPJ Web Conf. 174 (2018) 03003 Fulltext: PDF; External link: EDP Sciences Server
In : 4th International Conference on Micro Pattern Gaseous Detectors - MPGD2015, Trieste, Italy, 12 - 15 Oct 2015, pp.03003

没有寻找到什么? 尝试在以下的服务器查寻:
recid:2806226 在 Amazon
recid:2806226 在 CERN EDMS
recid:2806226 在 CERN Intranet
recid:2806226 在 CiteSeer
recid:2806226 在 Google Books
recid:2806226 在 Google Scholar
recid:2806226 在 Google Web
recid:2806226 在 IEC
recid:2806226 在 IHS
recid:2806226 在 INSPIRE
recid:2806226 在 ISO
recid:2806226 在 KISS Books/Journals
recid:2806226 在 KISS Preprints
recid:2806226 在 NEBIS
recid:2806226 在 SLAC Library Catalog