1.
|
|
2.
|
Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC
/ Aimard, B. (Annecy, LAPP) ; Aizawa, L. (Iwate U.) ; Alt, C. (Zurich, ETH) ; Asaadi, J. (Texas U., Arlington) ; Auger, M. (U. Bern, AEC) ; Aushev, V. (Taras Shevchenko U.) ; Autiero, D. (IP2I, Lyon) ; Balaceanu, A. (Bucharest, IFIN-HH) ; Balik, G. (Annecy, LAPP) ; Balleyguier, L. (IP2I, Lyon) et al.
The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. [...]
arXiv:2010.08370; FERMILAB-PUB-20-572-ND.-
2021-03-03 - 31 p.
- Published in : JINST 16 (2021) P03007
Fulltext: 2010.08370 - PDF; fermilab-pub-20-572-nd - PDF; Fulltext from Publisher: PDF; Fulltext from publisher: PDF; External link: Fermilab Library Server (fulltext available)
|
|
3.
|
A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers
/ Aimard, B. (Annecy, LAPP) ; Alt, Ch. (Zurich, ETH) ; Asaadi, J. (Texas U., Arlington) ; Auger, M. (U. Bern, AEC) ; Aushev, V. (Taras Shevchenko U.) ; Autiero, D. (Lyon, IPN) ; Badoi, M.M. (Bucharest, IFIN-HH) ; Balaceanu, A. (Bucharest, IFIN-HH) ; Balik, G. (Annecy, LAPP) ; Balleyguier, L. (Lyon, IPN) et al.
A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and oers several advantages compared to the traditional single-phase liquid argon TPCs. [...]
arXiv:1806.03317; FERMILAB-PUB-18-257-ND.-
2018-11-06 - 61 p.
- Published in : JINST 13 (2018) P11003
Fulltext: fermilab-pub-18-257-nd - PDF; fulltext1677274 - PDF; 1806.03317 - PDF; Fulltext from Publisher: PDF; External link: Fermilab Accepted Manuscript
|
|
4.
|
Development of Beam Loss Monitor for the SPring-8 Storage Ring
/ Shimosaki, Y (Japan Synch. Radiation Res. Inst.) ; Kobayashi, K (Japan Synch. Radiation Res. Inst.) ; Oishi, M (Japan Synch. Radiation Res. Inst.) ; Shoji, M (Japan Synch. Radiation Res. Inst.) ; Soutome, K (Japan Synch. Radiation Res. Inst.) ; Taniuchi, Y (Japan Synch. Radiation Res. Inst.)
2008 - 3 p.
External link: Published version from JACoW
In : 11th European Particle Accelerator Conference, Genoa, Italy, 23 - 27 Jun 2008, pp.TUPC096
|
|
5.
|
Remote Tilt-control System of Injection Bump Magnet in the SPring-8 Storage Ring
/ Fukami, K (Japan Synch. Radiation Res. Inst.) ; Hasegawa, M ; Mitsuda, C (Japan Synch. Radiation Res. Inst.) ; Nakanishi, T ; Ohshima, Takayoshi (JAERI-RIKEN, Hyogo) ; Oishi, M (Japan Synch. Radiation Res. Inst.) ; Shoji, M (Japan Synch. Radiation Res. Inst.) ; Soutome, K (Japan Synch. Radiation Res. Inst.) ; Yonehara, H (Japan Synch. Radiation Res. Inst.) ; Zhang, C (Japan Synch. Radiation Res. Inst.)
2008 - 3 p.
External link: Published version from JACoW
In : 11th European Particle Accelerator Conference, Genoa, Italy, 23 - 27 Jun 2008, pp.WEPC076
|
|
6.
|
Symmetry Restoration of the SPring-8 Storage Ring by Counter-sextupole Magnets
/ Soutome, K (Japan Synch. Radiation Res. Inst.) ; Daté, S (Japan Synch. Radiation Res. Inst.) ; Fujita, T (Japan Synch. Radiation Res. Inst.) ; Fukami, K (Japan Synch. Radiation Res. Inst.) ; Matsui, S (JAERI-RIKEN, Hyogo) ; Mitsuda, C (Japan Synch. Radiation Res. Inst.) ; Mochihashi, A (Japan Synch. Radiation Res. Inst.) ; Ohkuma, H (Japan Synch. Radiation Res. Inst.) ; Oishi, M (Japan Synch. Radiation Res. Inst.) ; Sasaki, S (Japan Synch. Radiation Res. Inst.) et al.
2008 - 3 p.
External link: Published version from JACoW
In : 11th European Particle Accelerator Conference, Genoa, Italy, 23 - 27 Jun 2008, pp.THPC070
|
|
7.
|
Filling of High Current Singlet and Train of Low Bunch Current in SPring-8 Storage Ring
/ Nakamura, T (Japan Synch. Radiation Res. Inst.) ; Fujita, T (Japan Synch. Radiation Res. Inst.) ; Fukami, K (Japan Synch. Radiation Res. Inst.) ; Kobayashi, K (Japan Synch. Radiation Res. Inst.) ; Mitsuda, C (Japan Synch. Radiation Res. Inst.) ; Ohshima, Takayoshi (JAERI-RIKEN, Hyogo) ; Oishi, M (Japan Synch. Radiation Res. Inst.) ; Sasaki, S (Japan Synch. Radiation Res. Inst.) ; Shoji, M (Japan Synch. Radiation Res. Inst.) ; Soutome, K (Japan Synch. Radiation Res. Inst.) et al.
2008 - 3 p.
External link: Published version from JACoW
In : 11th European Particle Accelerator Conference, Genoa, Italy, 23 - 27 Jun 2008, pp.THPC127
|
|
8.
|
Upgrade of Signal Processing of the BPM System at the SPring-8 Storage Ring
/ Fujita, Takahiro (JASRI/SPring-8, Hyogo-ken) ; Sasaki, Shigeki (JASRI/SPring-8, Hyogo-ken) ; Shoji, Masazumi (JASRI/SPring-8, Hyogo-ken) ; Takashima, Takeo (JASRI/SPring-8, Hyogo-ken)
2006 - 3 p.
External link: Published version from JACoW
In : 10th European Particle Accelerator Conference, Edinburgh, UK, 26 - 30 Jun 2006, pp.1130
|
|
9.
|
Production of MeV Photons by the Laser Compton Scattering Using a Far Infrared Laser at SPring-8
/ Ohkuma, Haruo (JASRI/SPring-8, Hyogo-ken) ; Arimoto, Yasushi (Osaka University, Osaka) ; Fujiwara, Mamoru (RCNP, Osaka) ; Kawase, Keigo (RCNP, Osaka) ; Nakayama, Kazuya (Chubu University, Kasugai, Aichi) ; Okajima, Shigeki (Chubu University, Kasugai, Aichi) ; Shoji, Masazumi (JASRI/SPring-8, Hyogo-ken) ; Suzuki, Shinsuke (JASRI/SPring-8, Hyogo-ken) ; Tamura, Kazuhiro (JASRI/SPring-8, Hyogo-ken) ; Yorita, Tetsuhiko (JASRI/SPring-8, Hyogo-ken)
2006 - 3 p.
External link: Published version from JACoW
In : 10th European Particle Accelerator Conference, Edinburgh, UK, 26 - 30 Jun 2006, pp.961
|
|
10.
|
A Problem in RF Switches of Multiplexing BPM System
/ Fujita, T ; Sasaki, S ; Shoji, M ; Takashima, T
At SPring-8, we have been developing a new detection circuit for beam position measurement with a resolution of submicron and a sampling time of a few milliseconds with high stability. In the circuit, a multiplexing method using RF switches is employed in order for a drift of the circuit to cancel out. [...]
2005
External link: Published version from JACoW
In : 7th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators, Lyons, France, 6 - 8 Jun 2005, pp.215
|
|