Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

CERN Document Server Намерени са 20 записа  1 - 10следващ  отиване на запис: Търсенето отне 0.80 секунди. 
1.
A New Luminosity Monitor for the LHC Run 3 / Mazzoni, Stefano (CERN) ; Andreazza, William (CERN) ; Balci, Elif (CERN) ; Belohrad, David (CERN) ; Bravin, Enrico (CERN) ; Chritin, Nicolas (CERN) ; Esteban Felipe, Jose (CERN) ; Lefèvre, Thibaut (CERN) ; Martin Nieto, Miguel (CERN) ; Palm, Marcus (CERN)
The Beam Rate of Neutrals (BRAN) is a monitor that provides a relative luminosity measurement for the four LHC experiments. BRANs are used during operations as a tool to find and optimise collision and to cross-check experiments luminosity monitors. [...]
2022 - 5 p. - Published in : JACoW IBIC 2022 (2022) 163-167 Fulltext: PDF;
In : 11th International Beam Instrumentation Conference (IBIC 2022), Cracow, Poland, 11 - 15 Sep 2022, pp.163-167
2.
Optical Transmission Characterization of Fused Silica Materials Irradiated at the CERN Large Hadron Collider / Yang, S. (Illinois U., Urbana) ; Tate, A. (Illinois U., Urbana) ; Longo, R. (Illinois U., Urbana) ; Gilarte, M. Sabate (CERN) ; Cerutti, F. (CERN) ; Mazzoni, S. (CERN) ; Grosse Perdekamp, M. (Illinois U., Urbana) ; Bravin, E. (CERN) ; Citron, Z. (Ben Gurion U. of Negev) ; Kühn, B. (Bitfabrik, Rodgau) et al.
The Target Absorbers for Neutrals (TANs) represent one of the most radioactive regions in the Large Hadron Collider (LHC). Seven 40 cm long fused silica rods with different dopant specifications, manufactured by Heraeus, were irradiated in one of the TANs located around the ATLAS experiment by the Beam RAte of Neutrals (BRAN) detector group. [...]
arXiv:2212.03392; FERMILAB-PUB-22-916-AD.- 2023-07-07 - 29 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 1055 (2023) 168523 Fulltext: 2212.03392 - PDF; FERMILAB-PUB-22-916-AD - PDF; External link: Fermilab Library Server
3.
$^{22}$Na activation level measurements of fused silica rods in the LHC target absorber for neutrals compared to simulations / Yang, S. (Illinois U., Urbana ; Illinois U., Urbana (main)) ; Gilarte, M. Sabate (CERN) ; Tate, A. (Illinois U., Urbana ; Illinois U., Urbana (main)) ; Santiago, N. (Illinois U., Urbana ; Illinois U., Urbana (main)) ; Longo, R. (Illinois U., Urbana) ; Mazzoni, S. (CERN) ; Cerutti, F. (CERN) ; Bravin, E. (CERN) ; Grosse Perdekamp, M. (Illinois U., Urbana) ; Lerner, G. (CERN) et al.
The Target Absorbers for Neutrals (TANs) are located in a high-intensity radiation environment inside the tunnel of the Large Hadron Collider (LHC). TANs are positioned about $140$ m downstream from the beam interaction points. [...]
arXiv:2204.01937.- 2022-09-01 - 11 p. - Published in : Phys. Rev. Accel. Beams 25 (2022) 091001 Fulltext: 2204.01937 - PDF; Publication - PDF;
4.
Optimal injection voltage in the LHC / Medina, L (CERN) ; Timko, H (CERN) ; Argyropoulos, T (CERN) ; Shaposhnikova, E (CERN) ; Salvachua, B (CERN) ; Wenninger, J (CERN) ; Karpov, I (CERN) ; Baudrenghien, P (CERN) ; Palm, M (CERN)
Finding the optimal rf injection voltage in the LHC is a trade-off between minimising capture and flat-bottom losses, which call for an increased voltage, and minimising rf power consumption as well as improving beam stability, both of which call for a reduced voltage. From the beam stability point of view, earlier particletracking simulations showed that the decrease of the injection voltage from 6 MV to 4 MV is beneficial. [...]
2022 - 8 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 1039 (2022) 166994 Fulltext: PDF;
5.
LHC Longitudinal Beam Dynamics during Run 2 / Timko, H (CERN) ; Argyropoulos, T (CERN) ; Baudrenghien, P (CERN) ; Calaga, R (CERN) ; Długosz, D (CERN) ; Müller, J F Esteban (CERN) ; Karpov, I (CERN) ; Medrano, L E Medina (CERN) ; Palm, M (CERN) ; Salvachua, B (CERN) et al.
During the LHC Run 2, many advances have been made on the beam dynamics in the longitudinal plane. The controlled longitudinal emittance blow-up used in the acceleration ramp was improved and bunch flattening was implemented for bunch length control during collisions. [...]
Geneva, Switzerland : , 2019 - 7 p. - Published in : , pp. 245-251 Fulltext: PDF;
In : 9th LHC Operations Evian Workshop, Evian Les Bains, France, 30 Jan - 1 Feb 2019, pp.245-251
6.
Performance requirements of the MedAustron beam delivery system / Palm, Marcus
The Austrian hadron therapy center MedAustron is currently under construction with patient treatment planned to commence in 2015 [...]
CERN-THESIS-2013-421 - 178 p.

Fulltext
7.
Beam-induced and cosmic-ray backgrounds observed in the ATLAS detector during the LHC 2012 proton-proton running period / ATLAS Collaboration
This paper discusses various observations on beam-induced and cosmic-ray backgrounds in the ATLAS detector during the LHC 2012 proton-proton run. Building on published results based on 2011 data, the correlations between background and residual pressure of the beam vacuum are revisited. [...]
arXiv:1603.09202; CERN-EP-2016-029; CERN-EP-2016-029.- Geneva : CERN, 2016-05-20 - 82 p. - Published in : JINST 11 (2016) P05013 Fulltext: 10.1088_1748-0221_11_05_P05013 - PDF; arXiv:1603.09202 - PDF; IOP Open Access article: PDF; External links: Previous draft version; Preprint
8.
Near-Saturation Single-Photon Avalanche Diode Afterpulse and Sensitivity Correction Scheme for the LHC Longitudinal density Monitor / Bravin, E ; Mazzoni, S ; Palm, M
Single-Photon Avalanche Diodes (SPADs) monitor the longitudinal density of the LHC beams by measuring the temporal distribution of synchrotron radiation. [...]
CERN-BE-2014-005.
- 2014. - 5 p.
Full text
9.
Transfer line scattering model of therapeutic hadron beams and applications to nozzle and gantry optimization / Palm, M (CERN) ; Benedikt, M (CERN) ; Dorda, U (CERN)
2013 - 10 p. - Published in : Phys. Rev. Spec. Top. Accel. Beams 16 (2013) 014702
- Published in : Phys. Rev. Spec. Top. Accel. Beams 16 (2013) 039901 APS Published version, local copy: PhysRevSTAB.16.014702 - PDF; PhysRevSTAB.16.039901 - PDF;
10.
LHC Luminosity calibration using the Longitudinal Density Monitor / Boccardi, A (CERN) ; Bravin, E (CERN) ; Ferro-Luzzi, M (CERN) ; Mazzoni, S (CERN) ; Palm, M (CERN)
The present note describes how data measured with the LHC Longitudinal Density Monitor (LDM) can contribute to the 2012-2013 LHC luminosity calibration experiments. [...]
CERN-ATS-Note-2013-034 TECH.
- 2013.
Full text - Full text

CERN Document Server : Намерени са 20 записа   1 - 10следващ  отиване на запис:
Виж също: автори с подобни имена
3 Palm, M.
4 Palm, Marcus
1 Palm, Margriet M
Интересувате ли се от уведомяване за нови резултати по тази заявка?
Set up a personal email alert or subscribe to the RSS feed.
Не намерихте, каквото търсите? Опитайте търсене в други сървъри:
Palm, M в Amazon
Palm, M в CERN EDMS
Palm, M в CERN Intranet
Palm, M в CiteSeer
Palm, M в Google Books
Palm, M в Google Scholar
Palm, M в Google Web
Palm, M в IEC
Palm, M в IHS
Palm, M в INSPIRE
Palm, M в ISO
Palm, M в KISS Books/Journals
Palm, M в KISS Preprints
Palm, M в NEBIS
Palm, M в SLAC Library Catalog
Palm, M в Scirus