1.
|
Construction and Test of MDT Chambers for the ATLAS Muon Spectrometer
/ Bauer, F. (Munich, Max Planck Inst.) ; Bratzler, U. (Munich, Max Planck Inst.) ; Dietl, H. (Munich, Max Planck Inst.) ; Kroha, H. (Munich, Max Planck Inst.) ; Lagouri, Th. (Munich, Max Planck Inst.) ; Manz, A. (Munich, Max Planck Inst.) ; Ostapchuk, A. (Munich, Max Planck Inst.) ; Richter, Robert (Munich, Max Planck Inst.) ; Schael, S. (Munich, Max Planck Inst.) ; Chouridou, S. (Munich U.) et al.
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the AT- LAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical monitoring system to correct for deformations. The full-scale prototype of a large MDT chamber has been constructed with methods suitable for large-scale production. [...]
MPP-2016-071; arXiv:1604.02000; MPI-PHE-2000-11; MPP-2016-071; MPI-PHE-2000-11.-
2001 - 5 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 461 (2001) 17-20
Preprint: PDF; External link: Preprint
In : 8th Pisa Meeting on Advanced Detectors : Frontier Detectors for Frontier Physics, La Biodola, Italy, 21 - 27 May 2000, pp.17-20
|
|
2.
|
Large-Scale Production of Monitored Drift Tube Chambers for the ATLAS Muon Spectrometer
/ Bauer, F. (Munich, Max Planck Inst.) ; Horvat, S ; Kortner, O ; Kroha, H ; Manz, A ; Mohrdieck, S ; Richter, R ; Zhuravlov, V
Precision drift tube chambers with a sense wire positioning accuracy of better than 20 microns are under construction for the ATLAS muon spectrometer. 70% of the 88 large chambers for the outermost layer of the central part of the spectrometer have been assembled. [...]
arXiv:1604.00240; MPI-PHE-2003-04; MPP-2003-151; MPP-2003-151.-
2016 - 4 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 518 (2004) 69-72
Fulltext: PDF; External link: Preprint
In : 9th Pisa Meeting on Advanced Detectors, La Biodola, Italy, 25 - 31 May 2003, pp.69
|
|
3.
|
Performance of the ATLAS Precision Muon Chambers under LHC Operating Conditions
/ Deile, M. (Munich, Max Planck Inst.) ; Dietl, H (Munich, Max Planck Inst.) ; Dubbert, J (Munich U.) ; Horvat, S (Munich, Max Planck Inst.) ; Kortner, O (Munich, Max Planck Inst.) ; Kroha, H (Munich, Max Planck Inst.) ; Manz, A (Munich, Max Planck Inst.) ; Mohrdieck, S (Munich, Max Planck Inst.) ; Rauscher, F (Munich U.) ; Richter, Robert (Munich, Max Planck Inst.) et al.
For the muon spectrometer of the ATLAS detector at the large hadron collider (LHC), large drift chambers consisting of 6 to 8 layers of pressurized drift tubes are used for precision tracking covering an active area of 5000 m2 in the toroidal ?eld of superconducting air core magnets. The chambers have to provide a spatial resolution of 41 microns with Ar:CO2 (93:7) gas mixture at an absolute pressure of 3 bar and gas gain of 2?104. [...]
MPI-PHE-2003-03; arXiv:1604.00236; MPI-PHE-2003-03.-
2004 - 4 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 518 (2004) 65-68
Preprint: PDF; External link: Preprint
In : 9th Pisa Meeting on Advanced Detectors, La Biodola, Italy, 25 - 31 May 2003, pp.65
|
|
4.
|
Resolution and Efficiency of the ATLAS Muon Drift-Tube Chambers at High Background Rates
/ Deile, M. (CERN ; Munich U. ; Munich, Max Planck Inst.) ; Dubbert, J. (CERN ; Munich U. ; Munich, Max Planck Inst.) ; Horvat, S. (CERN ; Munich U. ; Munich, Max Planck Inst.) ; Kortner, O. (CERN ; Munich U. ; Munich, Max Planck Inst.) ; Kroha, H. (CERN ; Munich U. ; Munich, Max Planck Inst.) ; Manz, A. (CERN ; Munich U. ; Munich, Max Planck Inst.) ; Mohrdieck-Mock, S. (CERN ; Munich U. ; Munich, Max Planck Inst.) ; Rauscher, F. (CERN ; Munich U. ; Munich, Max Planck Inst.) ; Richter, Robert (CERN ; Munich U. ; Munich, Max Planck Inst.) ; Staude, A. (CERN ; Munich U. ; Munich, Max Planck Inst.) et al.
The resolution and efficiency of a precision drift-tube chamber for the ATLAS muon spectrometer with final read-out electronics was tested at the Gamma Irradiation Facility at CERN in a 100 GeV muon beam and at photon irradiation rates of up to 990 Hz/square cm which corresponds to twice the highest background rate expected in ATLAS. A silicon strip detector telescope was used as external reference in the beam. [...]
MPP-2004-042; arXiv:1603.09572; MPP-2004-042.-
2016 - 4 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 535 (2004) 212
Preprint: PDF; External link: Preprint
In : 10th International Vienna Conference on Instrumentation, Vienna, Austria, 16 - 21 Feb 2004, pp.212-215
|
|
5.
|
|
6.
|
|
7.
|
|
8.
|
|
9.
|
|
10.
|
|