Ultra high voltage transmission in China: developments, current status and future prospects

D Huang, Y Shu, J Ruan, Y Hu - Proceedings of the IEEE, 2009 - ieeexplore.ieee.org
The developments and current status of ultra high voltage (UHV) alternating current (AC)
and direct current (DC) transmission in China were reviewed in this paper. The UHV …

Calculation of temperature rise in air-cooled induction motors through 3-D coupled electromagnetic fluid-dynamical and thermal finite-element analysis

Y Zhang, J Ruan, T Huang, X Yang… - IEEE Transactions on …, 2012 - ieeexplore.ieee.org
This paper investigates a 3-D coupled-field finite-element method (FEM) used in simulation
of temperature distributions in air-cooled asynchronous induction motors. The temperature …

3-D coupled electromagnetic-fluid-thermal analysis of oil-immersed triangular wound core transformer

C Liao, J Ruan, C Liu, W Wen… - IEEE Transactions on …, 2014 - ieeexplore.ieee.org
This paper presents a 3-D coupled electromagnetic-fluid-thermal analysis method for
temperature rise prediction in oil-immersed triangular wound core transformer. The temperatures …

Finite-element analysis of unbalanced magnetic pull in a large hydro-generator under practical operations

L Wang, RW Cheung, Z Ma, J Ruan… - IEEE Transactions on …, 2008 - ieeexplore.ieee.org
The rotor eccentricity of a large hydro-generator could cause a huge radial magnetic force,
known as an unbalanced magnetic pull (UMP), exerting on the rotor. In this paper, Maxwell …

HST calculation of a 10 kV oil‐immersed transformer with 3D coupled‐field method

J Ruan, Y Deng, D Huang, C Duan… - IET electric power …, 2020 - Wiley Online Library
Transformer winding hot‐spot temperature (HST) is one of the important factors affecting
transformer oil–paper insulation deterioration. This study presents a three‐dimensional coupled …

[HTML][HTML] Real-time temperature estimation of three-core medium-voltage cable joint based on support vector regression

J Ruan, Q Zhan, L Tang, K Tang - Energies, 2018 - mdpi.com
The joint is the weakest link in three-core medium-voltage power cable systems and the
temperature is an essential indicator to its insulation condition. Therefore, a model to estimate …

Short-term failure warning for transmission tower under land subsidence condition

L Zhang, J Ruan, Z Du, W Zhou, G Li, Y Gan - IEEE Access, 2020 - ieeexplore.ieee.org
Crustal movement and land subsidence will cause tower foundation settlement, which seriously
affects the safety of transmission line operation. This paper proposed a short-term failure …

A method for hot spot temperature prediction of a 10 kV oil-immersed transformer

Y Deng, J Ruan, Y Quan, R Gong, D Huang… - IEEE …, 2019 - ieeexplore.ieee.org
This paper proposed a prediction method to predict a 10-kV oil-immersed transformer hot
spot temperature (HST). A set of feature temperature points on the transformer iron shell is …

Chaotic analysis and feature extraction of vibration signals from power circuit breakers

Q Yang, J Ruan, Z Zhuang… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Vibration signals generated during circuit breaker (CB) closing or opening operations contain
rich information of operating mechanism (OM), transmission mechanism, and interrupter(s)…

A prediction method for breakdown voltage of typical air gaps based on electric field features and support vector machine

Z Qiu, J Ruan, D Huang, Z Pu… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
Breakdown voltage of the air gap is of vital importance for the design of the external insulation
in high-voltage transmission and transformation projects. In this paper, a new prediction …