de Asuncao et al. - Google Patents

3 Data Storage Equipment

de Asuncao et al.

View PDF
Document ID
11273255845008543207
Author
de Asuncao M
Lefevre L
Publication venue
Energy efficient IT and infrastructure for data centres and server rooms

External Links

Snippet

HDDs have long been the preferred media for non-volatile data storage that offers fast write and retrieval times. Moving parts such as motors and actuator arms account for most of the power that HDDs consume (see Figure 3.1). To improve data throughput of HDDs …
Continue reading at www.researchgate.net (PDF) (other versions)

Classifications

    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F1/00Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
    • G06F1/26Power supply means, e.g. regulation thereof
    • G06F1/32Means for saving power
    • G06F1/3203Power Management, i.e. event-based initiation of power-saving mode
    • G06F1/3206Monitoring a parameter, a device or an event triggering a change in power modality
    • G06F1/3215Monitoring of peripheral devices
    • G06F1/3221Monitoring of peripheral devices of disk drive devices
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F1/00Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
    • G06F1/26Power supply means, e.g. regulation thereof
    • G06F1/32Means for saving power
    • G06F1/3203Power Management, i.e. event-based initiation of power-saving mode
    • G06F1/3234Action, measure or step performed to reduce power consumption
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F3/00Input arrangements for transferring data to be processed into a form capable of being handled by the computer; Output arrangements for transferring data from processing unit to output unit, e.g. interface arrangements
    • G06F3/06Digital input from or digital output to record carriers, e.g. RAID, emulated record carriers, networked record carriers
    • G06F3/0601Dedicated interfaces to storage systems
    • G06F3/0628Dedicated interfaces to storage systems making use of a particular technique
    • G06F3/0629Configuration or reconfiguration of storage systems
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F1/00Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
    • G06F1/16Constructional details or arrangements
    • G06F1/20Cooling means
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F3/00Input arrangements for transferring data to be processed into a form capable of being handled by the computer; Output arrangements for transferring data from processing unit to output unit, e.g. interface arrangements
    • G06F3/06Digital input from or digital output to record carriers, e.g. RAID, emulated record carriers, networked record carriers
    • G06F3/0601Dedicated interfaces to storage systems
    • G06F3/0602Dedicated interfaces to storage systems specifically adapted to achieve a particular effect
    • G06F3/0604Improving or facilitating administration, e.g. storage management
    • G06F3/0605Improving or facilitating administration, e.g. storage management by facilitating the interaction with a user or administrator
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F3/00Input arrangements for transferring data to be processed into a form capable of being handled by the computer; Output arrangements for transferring data from processing unit to output unit, e.g. interface arrangements
    • G06F3/06Digital input from or digital output to record carriers, e.g. RAID, emulated record carriers, networked record carriers
    • G06F3/0601Dedicated interfaces to storage systems
    • G06F3/0668Dedicated interfaces to storage systems adopting a particular infrastructure
    • YGENERAL TAGGING OF NEW TECHNOLOGICAL DEVELOPMENTS; GENERAL TAGGING OF CROSS-SECTIONAL TECHNOLOGIES SPANNING OVER SEVERAL SECTIONS OF THE IPC; TECHNICAL SUBJECTS COVERED BY FORMER USPC CROSS-REFERENCE ART COLLECTIONS [XRACs] AND DIGESTS
    • Y02TECHNOLOGIES OR APPLICATIONS FOR MITIGATION OR ADAPTATION AGAINST CLIMATE CHANGE
    • Y02BINDEXING SCHEME RELATING TO CLIMATE CHANGE MITIGATION TECHNOLOGIES RELATED TO BUILDINGS, e.g. INCLUDING HOUSING AND APPLIANCES OR RELATED END-USER APPLICATIONS
    • Y02B60/00Information and communication technologies [ICT] aiming at the reduction of own energy use
    • Y02B60/10Energy efficient computing
    • Y02B60/12Reducing energy-consumption at the single machine level, e.g. processors, personal computers, peripherals, power supply
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F11/00Error detection; Error correction; Monitoring
    • G06F11/07Error detection; Error correction; Monitoring responding to the occurence of a fault, e.g. fault tolerance
    • G06F11/16Error detection or correction of the data by redundancy in hardware
    • G06F11/20Error detection or correction of the data by redundancy in hardware using active fault-masking, e.g. by switching out faulty elements or by switching in spare elements
    • G06F11/2015Redundant power supplies

Similar Documents

Publication Publication Date Title
Barroso et al. The datacenter as a computer: An introduction to the design of warehouse-scale machines
Vasques et al. A review on energy efficiency and demand response with focus on small and medium data centers
JP5055192B2 (en) Management apparatus and storage apparatus control method
Tolia et al. Delivering energy proportionality with non energy-proportional systems-optimizing the ensemble.
AU2011305487B2 (en) Data center control
US7953574B2 (en) Methods and apparatuses for heat management in information systems
Orgerie et al. Demystifying energy consumption in grids and clouds
CN104603881B (en) Storage device and the storage control of the storage device
US20090327778A1 (en) Information processing system and power-save control method for use in the system
US20090300374A1 (en) Storage apparatus and start-up control method for the same
US7836349B2 (en) Storage control device and enclosure-unit power control method
Barroso et al. The datacenter as a computer
Yeo et al. ATAC: Ambient temperature-aware capping for power efficient datacenters
CN109976465A (en) Server
Kaushik et al. Lightning: self-adaptive, energy-conserving, multi-zoned, commodity green cloud storage system
Bodik et al. A case for adaptive datacenters to conserve energy and improve reliability
Khatib et al. {PCAP}: Performance-aware Power Capping for the Disk Drive in the Cloud
de Asuncao et al. 3 Data Storage Equipment
Lefurgy et al. Energy-efficient data centers and systems
Niles et al. Virtualization and cloud computing: Optimized power, cooling, and management maximizes benefits
Kodama et al. High efficiency cloud data center management system using live migration
Geng Design of Energy‐Efficient IT Equipment
Dai et al. Data center energy flow and efficiency
Marra et al. Green Computing and power saving in HPC data centers
Kerstens et al. Applying Green Computing to clusters and the data center