Machin et al., 2011 - Google Patents

Estimation of the degree of equivalence of the ITS-90 above the silver point between NPL, NIM and CEM using high temperature fixed points

Machin et al., 2011

View PDF
Document ID
6062571598886445473
Author
Machin G
Dong W
Martín M
Lowe D
Yuan Z
Wang T
Lu X
Publication year
Publication venue
Metrologia

External Links

Snippet

Formal pair-wise temperature differences, a comparison reference value (CRV) and degree of equivalence, between the UK (NPL), Chinese (NIM) and Spanish (CEM) national measurement institutes (NMIs), are calculated from the results of a prototype key comparison …
Continue reading at www.researchgate.net (PDF) (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01KMEASURING TEMPERATURE; MEASURING QUANTITY OF HEAT; THERMALLY-SENSITIVE ELEMENTS NOT OTHERWISE PROVIDED FOR
    • G01K17/00Measuring quantity of heat
    • G01K17/06Measuring quantity of heat conveyed by flowing mediums, e.g. in heating systems e.g. the quantity of heat in a transporting medium, delivered to or consumed in an expenditure device
    • G01K17/08Measuring quantity of heat conveyed by flowing mediums, e.g. in heating systems e.g. the quantity of heat in a transporting medium, delivered to or consumed in an expenditure device based upon measurement of temperature difference or of a temperature
    • G01K17/20Measuring quantity of heat conveyed by flowing mediums, e.g. in heating systems e.g. the quantity of heat in a transporting medium, delivered to or consumed in an expenditure device based upon measurement of temperature difference or of a temperature across a radiating surface, combined with ascertainment of the heat transmission coefficient
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01JMEASUREMENT OF INTENSITY, VELOCITY, SPECTRAL CONTENT, POLARISATION, PHASE OR PULSE CHARACTERISTICS OF INFRA-RED, VISIBLE OR ULTRA-VIOLET LIGHT; COLORIMETRY; RADIATION PYROMETRY
    • G01J5/00Radiation pyrometry
    • G01J2005/0048Calibrating; Correcting
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01JMEASUREMENT OF INTENSITY, VELOCITY, SPECTRAL CONTENT, POLARISATION, PHASE OR PULSE CHARACTERISTICS OF INFRA-RED, VISIBLE OR ULTRA-VIOLET LIGHT; COLORIMETRY; RADIATION PYROMETRY
    • G01J5/00Radiation pyrometry
    • G01J5/02Details
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01JMEASUREMENT OF INTENSITY, VELOCITY, SPECTRAL CONTENT, POLARISATION, PHASE OR PULSE CHARACTERISTICS OF INFRA-RED, VISIBLE OR ULTRA-VIOLET LIGHT; COLORIMETRY; RADIATION PYROMETRY
    • G01J5/00Radiation pyrometry
    • G01J5/10Radiation pyrometry using electric radiation detectors
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01KMEASURING TEMPERATURE; MEASURING QUANTITY OF HEAT; THERMALLY-SENSITIVE ELEMENTS NOT OTHERWISE PROVIDED FOR
    • G01K7/00Measuring temperature based on the use of electric or magnetic elements directly sensitive to heat ; Power supply, e.g. by thermoelectric elements
    • G01K7/16Measuring temperature based on the use of electric or magnetic elements directly sensitive to heat ; Power supply, e.g. by thermoelectric elements using resistive elements
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01JMEASUREMENT OF INTENSITY, VELOCITY, SPECTRAL CONTENT, POLARISATION, PHASE OR PULSE CHARACTERISTICS OF INFRA-RED, VISIBLE OR ULTRA-VIOLET LIGHT; COLORIMETRY; RADIATION PYROMETRY
    • G01J5/00Radiation pyrometry
    • G01J5/0003Radiation pyrometry for sensing the radiant heat transfer of samples, e.g. emittance meter

Similar Documents

Publication Publication Date Title
Cagran et al. Temperature-resolved infrared spectral emissivity of SiC and Pt–10Rh for temperatures up to 900° C
Ishii et al. Uncertainty estimation for emissivity measurements near room temperature with a Fourier transform spectrometer
Wang et al. Transport properties of bulk thermoelectrics—An international round-robin study, Part I: Seebeck coefficient and electrical resistivity
Machin Twelve years of high temperature fixed point research: a review
Monte et al. The determination of the uncertainties of spectral emissivity measurements in air at the PTB
Machin et al. Estimation of the degree of equivalence of the ITS-90 above the silver point between NPL, NIM and CEM using high temperature fixed points
Fischer et al. Uncertainty budgets for realization of ITS‐90 by radiation thermometry
Machin et al. Practical implementation of the mise en pratique for the definition of the kelvin above the silver point
Zhang et al. Design, fabrication and characterization of high temperature thin film heat flux sensors
Todd et al. On the uncertainties in the realization of the kelvin based on thermodynamic temperatures of high-temperature fixed-point cells
Lowhorn et al. Development of a seebeck coefficient standard reference material
Akoshima et al. International comparison on thermal-diffusivity measurements for iron and isotropic graphite using the laser flash method in CCT-WG9
McCluskey et al. Nano-thermal transport array: An instrument for combinatorial measurements of heat transfer in nanoscale films
Hanssen et al. Use of a high-temperature integrating sphere reflectometer for surface-temperature measurements
Sasajima et al. Performance of WC–C peritectic and Ru–C eutectic fixed points
Yust et al. Transparent thin film thermocouple
Machin et al. A comparison of the ITS-90 among NPL, NIM, and CEM, above the silver point using high-temperature fixed points
Hao et al. A comparison of the In, Sn, Zn and Al fixed points by radiation thermometry between NIM and NPL and verification of the NPL blackbody reference sources from 156° C to 1000° C
Boguhn et al. Typical R (T 90) characteristics of platinum thin-film resistance thermometers in the temperature range from− 50 C to+ 660 C
Pearce et al. Melting temperature of high-temperature fixed points for thermocouple calibrations
Jahan et al. Annealing state dependence of the calibration of type R and type S thermocouples
Yoo et al. Realization of a radiation temperature scale from 0 C to 232 C by a thermal infrared thermometer based on a multiple-fixed-point technique
Machin et al. Bilateral comparison between NPL and INMETRO using a high-temperature fixed point of unknown temperature
Zhang et al. Calibration of a W/Re thermocouple using Pd-C, Pt-C and Ru-C eutectic cells at NIM
Astrua et al. Facility for the calibration of Pt/Pd thermocouples in the temperature range from 960 C to 1500 C