Nothing Special   »   [go: up one dir, main page]

McNulty et al., 2004 - Google Patents

Recruitment of single human low-threshold motor units with increasing loads at different muscle lengths

McNulty et al., 2004

Document ID
4393797839757437455
Author
McNulty P
Cresswell A
Publication year
Publication venue
Journal of Electromyography and Kinesiology

External Links

Snippet

We investigated the recruitment behaviour of low threshold motor units in flexor digitorum superficialis by altering two biomechanical constraints: the load against which the muscle worked and the initial muscle length. The load was increased using isotonic (low load) …
Continue reading at www.sciencedirect.com (other versions)

Classifications

    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/05Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves
    • A61B5/053Measuring electrical impedance or conductance of a portion of the body
    • A61B5/0531Measuring skin impedance
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/04Detecting, measuring or recording bioelectric signals of the body of parts thereof
    • A61B5/0488Electromyography
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/22Ergometry; Measuring muscular strength or the force of a muscular blow
    • A61B5/224Measuring muscular strength
    • A61B5/225Measuring muscular strength of the fingers, e.g. by monitoring hand-grip force
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/48Other medical applications
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/04Detecting, measuring or recording bioelectric signals of the body of parts thereof
    • A61B5/0476Electroencephalography
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/103Detecting, measuring or recording devices for testing the shape, pattern, colour, size or movement of the body or parts thereof, for diagnostic purposes
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/68Arrangements of detecting, measuring or recording means, e.g. sensors, in relation to patient
    • A61B5/6801Arrangements of detecting, measuring or recording means, e.g. sensors, in relation to patient specially adapted to be attached to or worn on the body surface
    • A61B5/6802Sensor mounted on worn items
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/68Arrangements of detecting, measuring or recording means, e.g. sensors, in relation to patient
    • A61B5/6801Arrangements of detecting, measuring or recording means, e.g. sensors, in relation to patient specially adapted to be attached to or worn on the body surface
    • A61B5/6813Specially adapted to be attached to a specific body part
    • A61B5/6825Hand
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61HPHYSICAL THERAPY APPARATUS, e.g. DEVICES FOR LOCATING OR STIMULATING REFLEX POINTS IN THE BODY; ARTIFICIAL RESPIRATION; MASSAGE; BATHING DEVICES FOR SPECIAL THERAPEUTIC OR HYGIENIC PURPOSES OR SPECIFIC PARTS OF THE BODY
    • A61H39/00Devices for locating or stimulating specific reflex points of the body for physical therapy, e.g. acupuncture
    • A61H39/04Devices for pressing such points, e.g. Shiatsu or Acupressure

Similar Documents

Publication Publication Date Title
Škarabot et al. Bilateral deficit in maximal force production
Lagerquist et al. Increased spinal reflex excitability is not associated with neural plasticity underlying the cross-education effect
Cordo et al. Treatment of severe hand impairment following stroke by combining assisted movement, muscle vibration, and biofeedback
Fallon et al. Evidence for strong synaptic coupling between single tactile afferents from the sole of the foot and motoneurons supplying leg muscles
Taylor et al. Multiple features of motor-unit activity influence force fluctuations during isometric contractions
Kouzaki et al. Alternate muscle activity observed between knee extensor synergists during low-level sustained contractions
Klass et al. Spinal mechanisms contribute to differences in the time to failure of submaximal fatiguing contractions performed with different loads
Christakos et al. Parallel neuronal mechanisms underlying physiological force tremor in steady muscle contractions of humans
Christou et al. Fluctuations in acceleration during voluntary contractions lead to greater impairment of movement accuracy in old adults
Shinohara et al. Prolonged muscle vibration increases stretch reflex amplitude, motor unit discharge rate, and force fluctuations in a hand muscle
Annino et al. Acute changes in neuromuscular activity in vertical jump and flexibility after exposure to whole body vibration
Shinohara et al. Contralateral activity in a homologous hand muscle during voluntary contractions is greater in old adults
Lourenção et al. Effect of biofeedback accompanying occupational therapy and functional electrical stimulation in hemiplegic patients
Ohn et al. Measurement of synergy and spasticity during functional movement of the post-stoke hemiplegic upper limb
Barss et al. Effects of a compression garment on sensory feedback transmission in the human upper limb
Ribot-Ciscar et al. Facilitation of triceps brachii muscle contraction by tendon vibration after chronic cervical spinal cord injury
Hur et al. Investigating the role of vibrotactile noise in early response to perturbation
Morcelli et al. Neuromuscular performance in the hip joint of elderly fallers and non-fallers
Bulthaup et al. An electromyography study of wrist extension orthoses and upper-extremity function
Williams et al. Neuromuscular fatigue of elbow flexor muscles of dominant and non-dominant arms in healthy humans
Kasprisin et al. Joint angle-dependence of elbow flexor activation levels during isometric and isokinetic maximum voluntary contractions
Hwang et al. Effects of Walkbot gait training on kinematics, kinetics, and clinical gait function in paraplegia and quadriplegia
McNulty et al. Recruitment of single human low-threshold motor units with increasing loads at different muscle lengths
Holmes et al. Posture and hand load alter muscular response to sudden elbow perturbations
Laidlaw et al. Nonuniform activation of the agonist muscle does not covary with index finger acceleration in old adults