D140 4 Voja Kasedo
"`html
Specifoj
- Produkto: Direct Expansion Indoor Unit for VRF
4-way Cassette - Modelo: Q4DN-3-XY D28 – D140
- Refrigerante: R-410A
Produktaj Uzado-Instrukcioj
Ĝeneralaj Teknikaj Datumoj
The indoor unit is available in various models with different
cooling and heating capacities, power supplies, and technical
specifications. Below are the general technical data for each
modelo:
Modelo | Malvarmiga Kapacito (kW) | Hejtado Kapacito (kW) | Elektroprovizo | Ventila Motora Tipo | Air Flow Rate (m3/h) | Sonprema Nivelo (dB) |
---|---|---|---|---|---|---|
Q4DN-3-XY D28 | 2.8 | 3.2 | 1-faza, 220-240V, 50Hz | Dc motoro | 790 | 30 |
Instalaj Instrukcioj
1. Ensure the power supply matches the unit requirements.
2. Connect the liquid and gas pipes according to the specified
grandecoj.
3. Install the drain pipe properly to avoid leakage.
Prizorgado kaj Purigado
1. Regularly clean the indoor coil and fan motor to maintain
optimuma rendimento.
2. Check for any refrigerant leaks and consult a professional if
bezonata.
Oftaj Demandoj
Q: Kion mi faru se la unuo ne malvarmiĝas/hejtas
ĝuste?
A: Check if the filters are clean and ensure proper airflow. If
the issue persists, contact a certified technician for
inspektado.
Q: Can I use a different refrigerant than R-410A?
A: It is recommended to use the specified refrigerant to
maintain product efficiency and performance.
“`
Direct expansion indoor unit for VRF
4-voja kasedo
Q4DN-3-XY D28 – D140
TBEOCLHLNEITCTIALNOBUTLELCENITTCION
VEE
R-410A
SIZE COOLING CAPACITY kW HEATING CAPACITY kW
D28 D36 D45 D56 D71 D80 D90 D100 D112 D140 D160 D180 2,8 3,6 4,5 5,6 7,1 8,0 9,0 10,0 11,2 14,0 16,0 18,0 3,2 4,0 5,0 6,3 8,0 9,0 10,0 11,2 12,5 16,0 18,0 20,0
Ĝeneralaj teknikaj datumoj
Modelo Elektroprovizo
Malvarmigo1
Kapacito Potenco enigo
Heating2 Fan motor type Indoor coil
Fluo de aero3
Kapacito
Potenco enigo
Number of rows Tube pitch × row pitch Fin spacing and type Tube OD and type Dimensions (L×H×W) Number of circuits
kW kBtu/h
W kW kBtu/h W
mm mm mm mm
m3/h
Nivelo de sonpremo 4
dB(A)
Nivelo de sonpotenco
dB(A)
Retaj dimensioj6 (L×H×D)
mm
Ĉefa korpo
Packed dimensions (W×H×D) mm
Neta / Malneta pezo
kg
Retaj dimensioj (L×H×D)
mm
Panelo
Packed dimensions (W×H×D) mm
Neta / Malneta pezo
kg
Fridiga tipo
Dezajna premo (H/L)
MPa
Likva/Gastubo
mm
Pipaj konektoj
Drentubo
mm
Q4DN-3-XY D28
Q4DN-3-XY D36
Q4DN-3-XY D45
Q4DN-3-XY D56
1-faza, 220-240V, 50Hz
2,8
3,6
4,5
5,6
9,6
12,3
15,4
19,1
17
17
23
23
3,2
4,0
5,0
6,3
10,9
13,7
17,1
21,5
17
17
23
23
Dc motoro
1
1
2
2
18×10,72
1,2 Hidrofila aluminio
5 Interna-kanelo
2165×144×10,72
4
4
8
8
790/740/691/641/591/542/492
840/787/733/680/6 26/573/519
840/791/741/692/6 42/593/543
30/29/28/27,5/27/26/25 30/29/28/27,5/27/26/25 33/32/31/30/29/28/27
33/32/31/30/29/28/27
43/42/41/41/40/39/39
44/43/42/42/41/40/39
49/48/47/46/45/44/43
49/48/48/47/46/45/44
840×204×840
940×250×940
18/20,5
19,5/22
950×53×950
1020×90×1020
5,6/7,3
R410A/R32
4,4/2,6
6,35/12,7
OD 25
Notes: 1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. 2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. 3. Air flow rate are from the highest speed to the lowest speed, total 7 rates for each model. 4. Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured 1.5m below the unit in a semi-anechoic chamber. 5. The dimension is only the body size, excluding the size of the installation lug, connecting copper pipe, etc. For detailed dimensions, please refer to the installation manual. 6. Exposed height of the panel after being installed on the ceiling.
2
Ĝeneralaj teknikaj datumoj
Modelo Elektroprovizo
Malvarmigo1
Kapacito Potenco enigo
Hejtado 2
Kapacito
Potenco enigo
Fanmotora tipo
Nombro de vicoj
Tuba peno × vico
Endoma bobeno
Fin spacing and type Tube OD and type
Grandecoj (L × H × W)
Nombro de cirkvitoj
Fluo de aero3
Nivelo de sonpremo 4
Nivelo de sonpotenco
Retaj dimensioj6 (L×H×D)
Ĉefa korpo
Plenplenaj dimensioj (L×H×D)
Neta / Malneta pezo
Retaj dimensioj (L×H×D)
Panelo
Plenplenaj dimensioj (L×H×D)
Neta / Malneta pezo
Fridiga tipo
Dezajna premo (H/L)
Liquid/Gas pipe Pipe connections
Drentubo
kW kBtu/h
W kW kBtu/h W
mm mm mm mm
m3/h dB(A) dB(A) mm mm
kg mm mm kg
MPa mm mm
Q4DN-3-XY D71
7.1 24.2 31 8.0 27.3 31
2
11 1000/943/886/829/772/715/658
37/36/34/33/32/30/29 51/50/49/48/47/46/46
Q4DN-3-XY D80 1-phase, 220-240V, 50Hz
8.0 27.3 41 9.0 30.7 41 DC 2 18×10.72 1.2 Hydrophilic aluminum 5 Inner-groove 2165×198×21.44 11 1330/1239/1148/1057/965/874/783 38/37/35/34/32/31/29 53/52/51/50/49/48/47 840×246×840 940×295×940 22/24.5 950×53×950 1020×90×1020 5.6/7.3 R410A/R32 4.4/2.6 9.52/15.9 OD 25
Q4DN-3-XY D90
9.0 30.7 43 10.0 34.1 43
2
11 1330/1239/1148/1057/965/874/783
38/37/35/34/32/31/29 54/53/52/51/50/49/48
Notes: 1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. 2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. 3. Air flow rate are from the highest speed to the lowest speed, total 7 rates for each model. 4. Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured 1.5m below the unit in a semi-anechoic chamber. 5. The dimension is only the body size, excluding the size of the installation lug, connecting copper pipe, etc. For detailed dimensions, please refer to the installation manual. 6. Exposed height of the panel after being installed on the ceiling.
3
Ĝeneralaj teknikaj datumoj
Modelo Elektroprovizo
Malvarmigo1
Kapacito Potenco enigo
Hejtado 2
Kapacito
Potenco enigo
Fanmotora tipo
Nombro de vicoj
Tuba peno × vico
Endoma bobeno
Fin spacing and type Tube OD and type
Grandecoj (L × H × W)
Nombro de cirkvitoj
Fluo de aero3
Nivelo de sonpremo 4
Nivelo de sonpotenco
Retaj dimensioj6 (L×H×D)
Ĉefa korpo
Plenplenaj dimensioj (L×H×D)
Neta / Malneta pezo
Retaj dimensioj (L×H×D)
Panelo
Plenplenaj dimensioj (L×H×D)
Neta / Malneta pezo
Fridiga tipo
Dezajna premo (H/L)
Liquid/Gas pipe Pipe connections
Drentubo
kW kBtu/h
W kW kBtu/h W
mm mm mm mm
m3/h dB(A) dB(A) mm mm
kg mm mm kg
MPa mm mm
Q4DN-3-XY D100
Q4DN-3-XY D112
Q4DN-3-XY D140
1-faza, 220-240V, 50Hz
10,0
11,2
14,0
34,1
38,2
47,8
54
61
89
11,2
12,5
16,0
38,2
42,7
54,6
54
61
89
DC
2
2
3
18×10,72
1.2 Hidrofila aluminio
5 Interna-kanelo
2165×252×21.44
2165×252×32.6
14
14
14
1445/1363/1282/1200/1118/1037/955 1600/1497/1393/1290/1186/1083/979 1730/1624/1518/1412/1306/1200/1094
39/38/37/36/35/34/33
41/40/38/37/36/34/33
43/42/40/39/37/36/34
54/53/52/51/50/50/49
57/56/55/54/53/52/51
58/57/56/55/54/53/52
840×288×840
940×335×940
24/26.5
26.5/29
950×53×950
1020×90×1020
5.6/7.3
R410A/R32
4.4/2.6
9.52/15.9
OD 25
Notes: 1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. 2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. 3. Air flow rate are from the highest speed to the lowest speed, total 7 rates for each model. 4. Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured 1.5m below the unit in a semi-anechoic chamber. 5. The dimension is only the body size, excluding the size of the installation lug, connecting copper pipe, etc. For detailed dimensions, please refer to the installation manual. 6. Exposed height of the panel after being installed on the ceiling.
4
Ĝeneralaj teknikaj datumoj
Modelo Elektroprovizo
Malvarmigo1
Kapacito Potenco enigo
Hejtado 2
Kapacito
Potenco enigo
Fanmotora tipo
Nombro de vicoj
Tuba peno × vico
Endoma bobeno
Fin spacing and type Tube OD and type
Grandecoj (L × H × W)
Nombro de cirkvitoj
Fluo de aero3
Nivelo de sonpremo 4
Nivelo de sonpotenco
Retaj dimensioj6 (L×H×D)
Ĉefa korpo
Plenplenaj dimensioj (L×H×D)
Neta / Malneta pezo
Retaj dimensioj (L×H×D)
Panelo
Plenplenaj dimensioj (L×H×D)
Neta / Malneta pezo
Fridiga tipo
Dezajna premo (H/L)
Liquid/Gas pipe Pipe connections
Drentubo
kW kBtu/h
W kW kBtu/h W
mm mm mm mm
m3/h dB(A) dB(A) mm mm
kg mm mm kg
MPa mm mm
Q4DN-3-XY D160
Q4DN-3-XY D180
1-faza, 220-240V, 50Hz
16,0
18,0
54.6
61.4
110.0
145.0
18.0
20.0
61.4
68.2
110.0
145.0
DC
3
3
18×10.72
1.2 Hidrofila aluminio
5 Interna-kanelo
2165×144×10.72
2165×144×10.72
14
14
2100/1900/1760/1630/1500/1380/1270
2300/2140/1960/1770/1600/1430/1270
48/46/44/43/41/39/37
52/49/47/45/42/39/38
56/53/51/49/47/46/45
59/56/54/51/49/46/45
950×300×950
950×300×950
1050×350×1050
1050×350×1050
32.6/37.2
32.7/37.3
1050×55×1050
1050×55×1050
1115×100×1115
1115×100×1115
7.4/9.7
7.4/9.7
R410A/R32
4.4/2.6
9.52/15.9
9.52/19.1
OD 25
Notes: 1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. 2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. 3. Air flow rate are from the highest speed to the lowest speed, total 7 rates for each model. 4. Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured 1.5m below the unit in a semi-anechoic chamber. 5. The dimension is only the body size, excluding the size of the installation lug, connecting copper pipe, etc. For detailed dimensions, please refer to the installation manual. 6. Exposed height of the panel after being installed on the ceiling.
5
Grandezze D28 ÷ D140 – (unit: mm)
Dimensioj
Four-way Cassette dimensions
Four-way Cassette piping connections
MODELO
A
B
C
D
F
E
D28 ÷ D56
204
141
63
41.5
12.7
6.35
D71 ÷ D90
246
163
103
41.5
15.9
9.52
D100 ÷ D140
288
190
103
56.5
15.9
9.52
6
Dimensioj
Grandezze D160 ÷ D180 (unit: mm)
MODELO
A
D160
300
D180
300
B
C
D
200
9.52
15.9
200
9.52
19.1
7
Unua lokado
Placement Considerations Unit placement should take account of the following considerations: · Units should not be installed in the following locations:
· A place filled with mineral oil, fumes or mist, like a kitchen. · A place where there are corrosive gases, such as acid or alkaline gases. · A place exposed to combustible gases and using volatile combustible gases such as diluent or gasoline. · A place where there is equipment emitting electromagnetic radiation. · A place where there is a high salt content in the air like a coast. · Do not use the air conditioner in an environment where an explosion may occur. · Places like in vehicles or cabin rooms. · Factories with major voltage fluctuations in the power supplies. · Other special environmental conditions. · Units should be installed in positions where: · Ensure that the airflow in and out of the IDU is reasonably organized to form an air circulation in the room. · Ensure IDU maintenance space. · The nearer the drainage pipe and copper pipe are to the ODU, the lower the pipe cost is. · Prevent the air conditioner from blowing directly to the human body. · The closer the wiring to the power cabinet, the lower the wiring cost is. · Keep the air-conditioning return air away from the setting sun of the room. · Be careful not to interfere with the light tank, fire pipe, gas pipe and other facilities. · The IDU should not be lifted in the places like load-bearing beam and columns that affect the structural safety of the house. · The wired controller and the IDU should be in the same installation space; otherwise, the sampling point setting of the wired con-
troller need to be changed.
Spacaj Postuloj
1. The centerline of the maintenance hole should be in the same position as the centerline of the indoor unit. 2. The dimensions of A are shown in Table 2,1
8
Fajba Diagramo
LEGENDO 1 2 3 4
T1
Enirejo Aera Temp. Sensilo
T2A
Likva Pipo Temp. Sensilo
T2
Meza Pipo Temp. Sensilo
T2B
Gas Pipo Temp. Sensilo
9
Dragramo
10
Notoj por instalistoj kaj servaj inĝenieroj
Caution · All installation , servicing and maintenance must be carried out by competent and suitably qualified, certified and accredited profes-
sionals and in accordance with all applicable legislation. · Units should be grounded in accordance with all applicable legislation . Metal and other conductive components should be insula-
ted in accordance with all applicable legislation. · Power supply wiring should be securely fastened at the power supply terminals – loose power supply wiring would represent a fire
risk. · After installation, servicing or maintenance, the electric control box cover should be closed. Failing to close the electric control box
cover risks fire or electric shock. · The dotted lines indicate the field wiring or optional function · D1D2 communication ports are used for group control communication. When connecting the group controller, the D1D2 port of the
indoor units that are to be group controlled must be connected in daisy chain, and the group controller must be connected to the X1X2 port of one of the indoor units in the group control, and set to group control mode. In addition, D1D2 communication ports can also be connected to the central controller.
11
Tabelo pri Malvarmiga Kapacito
Kapacitaj Tabeloj
MODELO
Q4DN-3-XY D28 Q4DN-3-XY D36 Q4DN-3-XY D45 Q4DN-3-XY D56 Q4DN-3-XY D71 Q4DN-3-XY D80 Q4DN-3-XY D90 Q4DN-3-XY D100 Q4DN-3-XY D112 Q4DN-3-XY D140 Q4DN-3-XY D160 Q4DN-3-XY D180
14/20
TC
SC
2.5
2.4
3.2
3.1
4.0
3.6
5.0
4.5
6.3
5.7
7.1
6.6
8.0
7.2
8.9
8.1
9.9
9.1
12.4
11.0
14.2 12.6
15.9
14.1
Abbreviations: TC: Total capacity (kW) SC: Sensible capacity(kW)
Notes: 1.Shaded cells indicate rating condition.
16/23
TC
SC
2.7
2.5
3.4
3.1
4.3
3.8
5.3
4.6
6.7
5.8
7.6
6.7
8.5
7.4
9.5
8.4
10.6
9.3
13.2
11.4
15.1
13.0
17.0
14.7
Endoma aera temperaturo (°C WB/DB)
18/26
19/27
20/28
TC
SC
TC
SC
TC
SC
2.8
2.5
2.8
2.4
2.9
2.3
3.6
3.2
3.6
3.0
3.7
3.0
4.5
3.8
4.5
3.7
4.6
3.6
5.6
4.7
5.6
4.6
5.7
4.5
7.0
5.9
7.1
5.8
7.2
5.6
7.9
6.8
8.0
6.6
8.1
6.4
8.9
7.5
9.0
7.3
9.1
7.1
9.9
8.4
10.0
8.2
10.1
7.9
11.1
9.4
11.2
9.2
11.3
8.9
13.8
11.5
14.0
11.3
14.2
11.0
15.8 13.2 16.0 12.9 16.2 12.5
17.8
14.8
18.0
14.5
18.2
14.1
22/30
TC
SC
2.9
2.2
3.8
2.8
4.7
3.4
5.8
4.2
7.4
5.4
8.3
6.1
9.4
6.8
10.4
7.6
11.6
8.4
14.5 10.5
16.6 12.0
18.7 13.5
24/32
TC
SC
3.0
2.1
3.9
2.7
4.8
3.3
6.0
4.1
7.6
5.2
8.5
5.8
9.6
6.5
10.6
7.2
11.9
8.1
14.9
10.1
17.0
11.5
19.1
12.9
Tablo de Kapacito de Hejtado
Indoor air temperature (°C DB)
MODELO
16
18
20
21
22
24
TC
TC
TC
TC
TC
TC
Q4DN-3-XY D28
3.4
3.4
3.2
3.1
3.0
2.8
Q4DN-3-XY D36
4.2
4.2
4.0
3.8
3.8
3.5
Q4DN-3-XY D45
5.3
5.3
5.0
4.8
4.7
4.4
Q4DN-3-XY D56
6.7
6.6
6.3
6.1
5.9
5.5
Q4DN-3-XY D71
8.5
8.4
8.0
7.8
7.5
7.0
Q4DN-3-XY D80
9.5
9.5
9.0
8.7
8.5
7.8
Q4DN-3-XY D90
10.6
10.5
10.0
9.7
9.4
8.8
Q4DN-3-XY D100
11.9
11.8
11.2
10.9
10.5
9.8
Q4DN-3-XY D112
13.3
13.1
12.5
12.1
11.8
10.9
Q4DN-3-XY D140
17.0
16.8
16.0
15.5
15.0
13.9
Q4DN-3-XY D160
19.1
19.1
18.0
17.4
16.9
15.8
Q4DN-3-XY D180
21.3
21.3
20.0
19.4
18.8
17.5
Abbreviations: TC: Total capacity (kW)
Notes: 1.Shaded cells indicate rating condition.
12
Elektraj karakterizaĵoj
MODEL Hz
Q4DN-3-XY D28
50
Q4DN-3-XY D36
50
Q4DN-3-XY D45
50
Q4DN-3-XY D56
50
Q4DN-3-XY D71
50
Q4DN-3-XY D80
50
Q4DN-3-XY D90
50
Q4DN-3-XY D100
50
Q4DN-3-XY D112
50
Q4DN-3-XY D140
50
Q4DN-3-XY D160
50
Q4DN-3-XY D180
50
Voltojn
220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240
Elektroprovizo
Min. volts Max. volts
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
MCA
0.51 0.51 0.59 0.59 0.94 1.05 1.09 0.95 1.18 1.41 2.30 2.73
MFA
15 15 15 15 15 15 15 15 15 15 15 15
Endomaj ventolilaj motoroj
Taksita motorproduktado (kW)
F.L.A.
0.045
0.41
0.045
0.41
0.045
0.47
0.045
0.47
0.125
0.75
0.125
0.84
0.125
0.87
0.125
0.76
0.125
0.94
0.125
1.13
0.125
1.83
0.125
2.10
Mallongigoj: MCA: Minimuma Cirkvito Amps MFA: Maksimuma Fuzeo Amps FLA: Plena Ŝarĝo Amps
Notes: Voltage gamo: Unuoj taŭgas por uzo sur elektraj sistemoj kie voltage liverita al unuoterminaloj ne estas sub aŭ super listigitaj intervallimoj. Maksimuma alleblas voltage variation between phases is 2%. Selection wire size based on the value of MCA. MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth circuit breaker).
13
Sonnivelo
Entute
MODELO
Sonpremniveloj dB
SSH SH H
M
L
SL SSL
Q4DN-3-XY D28 30 29 28 27 26.5 26 25
Q4DN-3-XY D36 30 29 28 27 26.5 26 25
Q4DN-3-XY D45 33 32 31 30 29 28 27
Q4DN-3-XY D56 33 32 31 30 29 28 27
Q4DN-3-XY D71 37 36 34 33 32 30 29
Q4DN-3-XY D80 38 37 35 34 32 31 29
Q4DN-3-XY D90 38 37 35 34 32 31 29
Q4DN-3-XY D100 39 38 37 36 35 34 33
Q4DN-3-XY D112 41 40 38 37 36 34 33
Q4DN-3-XY D140 43 42 40 39 37 36 34
Q4DN-3-XY D160 48 46 44 43 41 39 37
Q4DN-3-XY D180 52 49 47 45 42 39 38
Notes: 1. Sound pressure levels are measured 1.5m below the unit in a semi-anechoic chamber at 0 Pa. During in-situ operation, sound pressure levels may be higher as a result of ambient noise.
Octave Band Niveloj
Q4DN-3-XY D28
Q4DN-3-XY D36
Q4DN-3-XY D45
Q4DN-3-XY D56
14
Sonnivelo
Q4DN-3-XY D71
Q4DN-3-XY D90
Q4DN-3-XY D112
Q4DN-3-XY D160
Q4DN-3-XY D80 Q4DN-3-XY D100
Q4DN-3-XY D140 Q4DN-3-XY D180
15
Distribuado de Temperaturo kaj Aerfluo
Simuli kondiĉon
MODEL NAME Room size (m)
Q4DN-3-XY D28 Q4DN-3-XY D36 Q4DN-3-XY D45 Q4DN-3-XY D56 Q4DN-3-XY D71 Q4DN-3-XY D80 Q4DN-3-XY D90 Q4DN-3-XY D100 Q4DN-3-XY D112 Q4DN-3-XY D140 Q4DN-3-XY D160 Q4DN-3-XY D180
6×6 6×6 6×6 8×8 8×8 8×8 10×10 10×10 10×10 10×10 10×10 10×10
Plafona alteco (m)
2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7
Flow angle (Cooling/Hea-
ting) 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65°
Lokado
Center Center Center Center Center Center Center Center Center Center Center Center
Note: 1. These figures and videos are based on software simulation. They show typical temperature and airflow distributions in the conditions above. In the actual installation, they may differ from these figures and videos under the influence of air temperature conditions, ceiling height, cooling/heating load, obstacles, etc.
Aerfluodistribuoj - Malvarmigo (post 300s)
Q4DN-3-XY D28
Q4DN-3-XY D36
Q4DN-3-XY D45
Q4DN-3-XY D56
Q4DN-3-XY D71
Q4DN-3-XY D80
16
Distribuado de Temperaturo kaj Aerfluo
Q4DN-3-XY D90
Q4DN-3-XY D100
Q4DN-3-XY D112 Q4DN-3-XY D160
Q4DN-3-XY D140 Q4DN-3-XY D180
17
Distribuado de Temperaturo kaj Aerfluo
Aerfluodistribuoj - Hejtado (post 300s)
Q4DN-3-XY D28
Q4DN-3-XY D36
Q4DN-3-XY D45
Q4DN-3-XY D56
Q4DN-3-XY D71
Q4DN-3-XY D80
Q4DN-3-XY D90
Q4DN-3-XY D100
18
Distribuado de Temperaturo kaj Aerfluo
Q4DN-3-XY D112
Q4DN-3-XY D140
Q4DN-3-XY D160
Q4DN-3-XY D180
19
Temperaturdistribuoj - Malvarmigo (post 300s)
Q4DN-3-XY D28
Q4DN-3-XY D36
Q4DN-3-XY D45
Q4DN-3-XY D56
Q4DN-3-XY D71
Q4DN-3-XY D80
Q4DN-3-XY D90
Q4DN-3-XY D100
20
Q4DN-3-XY D112 Q4DN-3-XY D160
Q4DN-3-XY D140 Q4DN-3-XY D180
21
Temperaturaj distribuoj - Hejtado (post 300s)
Q4DN-3-XY D28
Q4DN-3-XY D36
Q4DN-3-XY D45
Q4DN-3-XY D56
Q4DN-3-XY D71
Q4DN-3-XY D80
Q4DN-3-XY D90
Q4DN-3-XY D100
22
Q4DN-3-XY D112 Q4DN-3-XY D160
Q4DN-3-XY D140 Q4DN-3-XY D180
23
DE 30 JAROJ NI OFFERTAS SOLVOJN POR Daŭrigebla komforto kaj bonfarto de la homoj kaj de la medio.
www.clivet.com
vendo kaj servo
SCRE 4W-Liwnaey4-ic -assWetDtAeN–iQK4DMNF-3-BXTY21ID02083-I–D01240 – BT23N009GB–00
.CLIVET S.p.A
Per Camp Lonc 25, Z.I. Villapaiera 32032 – Feltre (BL) – Italy Tel. +39 0439 3131 – info@clivet.it
CLIVET GMBH
Hummelsbütteler Steindamm 84, 22851 Norderstedt, Germanujo Tel. +49 40 325957-0 – info.de@clivet.com
Clivet Group UK LTD
Unuoj F5 & F6 Fervoja Triangulo, Portsmouth, Hampgrafejo PO6 1TG Tel. +44 02392 381235 Enquiries@Clivetgroup.co.uk
CLIVET LLC
Oficejo 508-511, Elektozavodskaya st. 24, Moskvo, Rusa Federacio, 107023 Tel. +7495 6462009 - info.ru@clivet.com
Clivet Sudorienta Eŭropo
Jaruscica 9b 10000, Zagreb, Croatia
Tel. +3851 222 8784 – info.see@clivet.com
CLIVET MIDEAST FZCO
Dubai Silicon Oasis (DSO) Ĉefsideja Konstruaĵo, Oficejo EG-05, PO Box-342009, Dubajo, UAE Tel. +9714 3208499 – info@clivet.ae
CLIVET Francio
10, rue du Fort de Saint Cyr - 78180 Montigny le Bretonneux, Francio
info.fr@clivet.com
Clivet Airconditioning Systems Pvt Ltd
Office No.501 & 502,5th Floor, Commercial I, Kohinoor City, Old Premier Compound, Off LBS
Marg, Kirol Road, Kurlokcidento, Mumbajo
Maharaŝtro 400070, Hindio
Tel. +91 22 30930200 – sales.india@clivet.com
Dokumentoj/Rimedoj
CLIveT D140 4 Way Cassette [pdf] Instrukcia Manlibro D140 4 Way Cassette, D140, 4 Way Cassette, Cassette |