Abstract
Ectopic beats are abnormal cardiac beats originating from a location different than the sino-atrial node and therefore not being controlled by the autonomous nervous system. Thus, correct heart rate variability analysis inevitably requires accurate ectopic beat detection. Furthermore, an accurate ectopic beat detection is crucial to differentiate irregular cardiac rhythm due to different types of pathological arrhythmias from those caused by isolated ectopic beats. In this paper, we present an algorithm for ectopic beat detection based on wrist plethysmographic (PPG) signals. The proposed algorithm relies on analyzing the inter-beat patterns while considering the heart-rhythm condition; whether sinus rhythm (SR) or atrial fibrillation (AF). We monitor 29 patients recovering from surgery in the post-anesthesia care unit. During the recordings, 15 patients had SR and 14 patients had AF. The proposed ectopic beat detection algorithm achieves a sensitivity of \(93.08 \pm 3.83\%\) and a specificity of \(97.80 \pm 2.12\%\).
J. Parak—Affiliation at the time of the research.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Harju, J., Tarniceriu, A., Parak, J., Vehkaoja, A., Yli-Hankala, A., Korhonen, I.: Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation. In: Physiological Measurement, IOP Publishing, vol. 39, no. 6, pp. 65007–65019, June (2018)
Tarniceriu, A., Harju, J., Yousefi, Z. R., Vehkaoja, A., Parak, J., Yli-Hankala, A., Korhonen, I.: The accuracy of atrial fibrillation detection from wrist photoplethysmography. A study on post-Operative patients. In: 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, pp. 1–4 (2018)
Mateo, J., Laguna P.: Analysis of heart rate variability in the presence of ectopic beats using the heart timing signal. In: IEEE Transactions on Biomedical Engineering, vol. 50, no. 3, pp. 334–343, March 2003
Hekler, A., Kikillus, N., Bolz, A.: Detection of ectopic beats in single channel electrocardiograms. In: Vander Sloten, J., Verdonck, P., Nyssen, M., Haueisen, J. (eds.) 4th European Conference of the International Federation for Medical and Biological Engineering (IFMBE) Proceedings, vol. 22. Springer, Heidelberg (2009)
Dib, N., Bereksi, R.: Ectopic beats detection and correction methods: a review. In: Biomedical Signal Processing Control, vol. 18, pp. 228–244, April 2015
Lemay, M., Bertschi, M., Sola, J., Renevey, P., Parak, J., Korhonen, I.: Application of optical heart rate monitoring. In: Sazonov E., Neuman, M. R. (eds.) Wearable Sensors: Fundamentals, Implementation and Applications, Elsevier, Imprint: Academic Press, pp. 105–129 (2014)
Parak, J., Korhonen, I.: Evaluation of wearable consumer heart rate monitors based on photopletysmography. In: 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Chicago, pp. 3670–3673 (2014)
Delgado-Gonzalo, R., Parak, J., Tarniceriu, A., Renevey, P., Bertschi, M., Korhonen, I.: Evaluation of accuracy and reliability of PulseOn optical heart rate monitoring device. In: 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, pp. 430–433 (2015)
Renevey, P., Sola, J., Theurillat, P., Bertschi, M., Krauss, J., Andries, D., Sartori, C.: Validation of a wrist monitor for accurate estimation of RR intervals during sleep. In: 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Osaka, pp. 5493–5496 (2013)
Parak, J., Tarniceriu, A., Renevey, P., Bertschi, M., Delgado-Gonzalo, R., Korhonen, I.: Evaluation of the beat-to-beat detection accuracy of PulseOn wearable optical heart rate monitor. In: 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, pp. 8099–8102 (2013)
Schäfer, A., Vagedes, J.: How accurate is pulse rate variability as an estimate of heart rate variability? A review on studies comparing photoplethysmographic technology with an electrocardiogram. Int. J. Cardiol. 166(1), 15–29 (2013)
Tarniceriu, A., Harju, J., Vehkaoja, A., Parak, J., Delgado-Gonzalo, R., Renevey, P., Yli-Hankala, A., Korhonen, I.: Detection of beat-to-beat intervals from wrist photoplethysmography in patients with sinus rhythm and atrial fibrillation after surgery. In: IEEE EMBS International Conference on Biomedical & Health Informatics (BHI), Las Vegas, pp. 133–136 (2018)
Moody, G. B., Mark, R. G.: A new method for detecting atrial fibrillation using R-R intervals. In: Computers in Cardiology, pp. 227—230 (1983)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Haddad, S. et al. (2020). Ectopic Beat Detection from Wrist Optical Signals for Sinus Rhythm and Atrial Fibrillation Subjects. In: Henriques, J., Neves, N., de Carvalho, P. (eds) XV Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019. MEDICON 2019. IFMBE Proceedings, vol 76. Springer, Cham. https://doi.org/10.1007/978-3-030-31635-8_18
Download citation
DOI: https://doi.org/10.1007/978-3-030-31635-8_18
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-31634-1
Online ISBN: 978-3-030-31635-8
eBook Packages: EngineeringEngineering (R0)