The ALICE CPV Detector

Published date: Apr 09 2018

Journal Title: KnE Energy

Issue title: The 3rd International Conference on Particle Physics and Astrophysics (ICPPA)

Pages: 260–267

DOI: 10.18502/ken.v3i1.1752

Authors:
Abstract:

The Charged-Particle Veto (CPV) detector of ALICE at the LHC is presented. Physics motivation for the detector, its construction and operation in physics runs are shortly discussed. Readout electronics and data taking conditions are described. Special attention is focused on CPV automation via the detector control system. Different states of the detector and protection algorithms implemented into the control system are described.

References:

[1] G. Dellacasa et al. [ALICE Collaboration], “ALICE technical design report of the photon spectrometer (PHOS),” CERN-LHCC-99-04.


[2] K. Aamodt et al. [ALICE Collaboration], “The ALICE experiment at the CERN LHC,” JINST 3 (2008) S08002. doi:10.1088/1748-0221/3/08/S08002


[3] B. Alessandro et al. [ALICE Collaboration], “ALICE: Physics performance report, volume II,” J. Phys. G 32 (2006) 1295. doi:10.1088/0954-3899/32/10/001


[4] A. M. Blick et al., “A charged-particle detector based on proportional tubes with a segmented cathode and cathode readout,” Instrum. Exp. Tech. 44 (2001) 339 [Prib. Tekh. Eksp. 2001 (2001) no.3, 63]. doi:10.1023/A:1017524523571


[5] M. Y. Bogolyubsky et al. [ALICE Collaboration], “Charged Particle Veto Detector with Open Geometry for the PHOS Spectrometer,” ALICE-INT-2000-21, CERN-ALICE-INT- 2000-21.


[6] M. Y. Bogolyubsky et al. [ALICE Collaboration], “Charged Particle Veto Detector for the PHOS Spectrometer,” ALICE-INT-1999-08, CERN-ALICE-INT-1999-08.


[7] J. C. Santiard et al. [ALICE Collaboration], “The GASSIPLEX0.7-2 integrated front-end analog processor for the HMPID and the dimuon spectrometer of ALICE,” CERNALICE- PUB-2001-49, CERN-ALI-2001-049.


[8] J. C. Santiard, “The ALICE HMPID on-detector front-end and readout electronics,” Nucl. Instrum. Meth. A 518 (2004) 498. doi:10.1016/j.nima.2003.11.068


[9] G. Aglieri Rinella et al. [ALICE Collaboration], “The level 0 pixel trigger system for the ALICE experiment,” JINST 2 (2007) P01007. doi:10.1088/1748-0221/2/01/P01007


[10] B. Hallgren, H. Boterenbrood, H. J. Burckhart and H. Kvedalen, “The embedded local monitor board (ELMB) in the LHC front-end I/O control system,”


[11] SCADA System Siemens WinCC http://w3.siemens.com/mcms/automation/


[12] JCOP Framework http://jcop.web.cern.ch/jcop-framework

Download