Nothing Special   »   [go: up one dir, main page]

Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.5599/jese.630

A sensitive electrochemical sensor based on polypyrrole/electrochemically reduced graphene oxide for the determination of imidacloprid

Chenglong Chen ; School of Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
Zhen Han ; School of Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
Wu Lei ; School of Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
Yong Ding ; School of Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
Jingjing Lv ; School of Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
Mingzhu Xia ; School of Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
Fengyun Wang ; School of Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
Qingli Hao ; School of Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China


Puni tekst: engleski pdf 1.095 Kb

str. 143-152

preuzimanja: 490

citiraj


Sažetak

The glassy carbon electrode (GCE) was modified by electrochemically reduced graphene oxide (ERGO) and polypyrrole (PPy) prepared by simple cyclic voltammetry (CV) electropoly­merization. The PPy/ERGO modified electrode (PPy/ERGO/GCE) was used as a platform of electrochemical sensor to detect imidacloprid (IMI) insecticide. CV and differential pulse voltammetry (DPV) were chosen as the methods to investigate of the electrochemical behavior of IMI on PPy/ERGO/GCE surface. Scanning electron microscopy (SEM) and Raman spectra were utilized to describe the morphology and structure of the modified electrode. Experimental parameters were optimized, such as the number of polymerization cycles, scan rate and the pH value of electrolyte. Under the optimized conditions, when the concentration of IMI was in the range of 1-10 μM and 10-60 μM, the increase of reduction peak current was linear with the concentration of IMI, and the low detection limit was found to be 0.18 μM (S/N = 3). Results showed that PPy/ERGO/GCE demonstrated satisfactory reproducibility and stability, and has great potential in actual sample testing.

Ključne riječi

Electropolymerization; modified electrode; imidacloprid insecticide; electrochemical behavior; actual samples

Hrčak ID:

219922

URI

https://hrcak.srce.hr/219922

Datum izdavanja:

6.5.2019.

Posjeta: 1.304 *