Europe PMC
Nothing Special   »   [go: up one dir, main page]

Europe PMC requires Javascript to function effectively.

Either your web browser doesn't support Javascript or it is currently turned off. In the latter case, please turn on Javascript support in your web browser and reload this page.

This website requires cookies, and the limited processing of your personal data in order to function. By using the site you are agreeing to this as outlined in our privacy notice and cookie policy.

Abstract 


In endothelial cells, different types of Ca2+ conductances have been described, but none of them has been clearly identified as ICRAC, the Ca2+ release-activated Ca2+ current originally described in mast and lymphoma cells. Here we show that in bovine pulmonary artery endothelial cells (CPAE) depletion of intracellular Ca2+ stores by inositol 1,4,5-trisphosphate (InsP3), Ca2+ ionophores and Ca2+ pump inhibitors activates a Ca2+-selective conductance in the presence of the Ca2+ chelator 1,2-bis(2-aminophenoxy)ethane-N,N,N', N'-tetraacetic acid (BAPTA). The current shows inward rectification, a highly positive reversal potential and is blocked by micromolar concentrations of La3+. The conditions used in studies of endothelial cells were also employed in those of HEK-293, an embryonic kidney cell line commonly used to express putative store-operated channels, and Jurkat cells, the reference cell model. Similar to CPAE, HEK cells also have an ICRAC-like current. At 0 mV holding potential the estimated current density is -0.1 and -0.2 pA/pF in CPAE and HEK cells respectively, i.e. 15 and 30% of that measured in Jurkat cells. As shown in studies of Jurkat cells, larger Na+ currents are detectable in CPAE and HEK cells following store depletion in Ca2+- and Mg2+-free medium. The current carried by Na+ ions is similarly blocked by micromolar La3+, is inwardly rectifying and has a positive reversal potential.

Citations & impact 


Impact metrics

Jump to Citations

Citations of article over time

Alternative metrics

Altmetric item for https://www.altmetric.com/details/43260154
Altmetric
Discover the attention surrounding your research
https://www.altmetric.com/details/43260154

Smart citations by scite.ai
Smart citations by scite.ai include citation statements extracted from the full text of the citing article. The number of the statements may be higher than the number of citations provided by EuropePMC if one paper cites another multiple times or lower if scite has not yet processed some of the citing articles.
Explore citation contexts and check if this article has been supported or disputed.
https://scite.ai/reports/10.1007/s004240050605

Supporting
Mentioning
Contrasting
4
62
2

Article citations


Go to all (55) article citations