Europe PMC
Nothing Special   »   [go: up one dir, main page]

Europe PMC requires Javascript to function effectively.

Either your web browser doesn't support Javascript or it is currently turned off. In the latter case, please turn on Javascript support in your web browser and reload this page.

This website requires cookies, and the limited processing of your personal data in order to function. By using the site you are agreeing to this as outlined in our privacy notice and cookie policy.

Abstract 


Purpose

To evaluate intra-patient and interobserver agreement in patients who underwent liver MRI with gadoxetic acid using two different multi-arterial phase (AP) techniques.

Methods

A total of 154 prospectively enrolled patients underwent clinical gadoxetic acid-enhanced liver MRI twice within 12 months, using two different multi-arterial algorithms: CAIPIRINHA-VIBE and TWIST-VIBE. For every patient, breath-holding time, body mass index, sex, age were recorded. The phase without contrast media and the APs were independently evaluated by two radiologists who quantified Gibbs artefacts, noise, respiratory motion artefacts, and general image quality. Presence or absence of Gibbs artefacts and noise was compared by the McNemar's test. Respiratory motion artefacts and image quality scores were compared using Wilcoxon signed rank test. Interobserver agreement was assessed by Cohen kappa statistics.

Results

Compared with TWIST-VIBE, CAIPIRINHA-VIBE images had better scores for every parameter except higher noise score. Triple APs were always acquired with TWIST-VIBE but failed in 37% using CAIPIRINHA-VIBE: 11% have only one AP, 26% have two. Breath-holding time was the only parameter that influenced the success of multi-arterial techniques. TWIST-VIBE images had worst score for Gibbs and respiratory motion artefacts but lower noise score.

Conclusion

CAIPIRINHA-VIBE images were always diagnostic, but with a failure of triple-AP in 37%. TWIST-VIBE was successful in obtaining three APs in all patients. Breath-holding time is the only parameter which can influence the preliminary choice between CAIPIRINHA-VIBE and TWIST-VIBE algorithm.

Advances in knowledge

If the patient is expected to perform good breath-holds, TWIST-VIBE is preferable; otherwise, CAIPIRINHA-VIBE is more appropriate.

References 


Articles referenced by this article (29)


Show 10 more references (10 of 29)

Citations & impact 


Impact metrics

Jump to Citations

Alternative metrics

Altmetric item for https://www.altmetric.com/details/162650379
Altmetric
Discover the attention surrounding your research
https://www.altmetric.com/details/162650379

Article citations

Similar Articles 


To arrive at the top five similar articles we use a word-weighted algorithm to compare words from the Title and Abstract of each citation.