Abstract
Full text links
Read article at publisher's site: 3.0.co;2-m">https://doi.org/10.1002/(sici)1097-0290(19990620)63:6<705::aid-bit8>3.0.co;2-m
References
Articles referenced by this article (26)
Title not supplied
J Biotechnol 1995
Death mechanisms of animal cells in conditions of intensive agitation.
Biotechnol Bioeng, (6):463-472 1995
MED: 18623245
editors. 1996. Flow cytometry applications in cell culture. New York: Marcel Dekker Inc. 331 p.
1996. Escherichia coli high cell density fed batch cultures: Kinetic and physiological aspects. PhD thesis. Stockholm, Sweden. Royal Institute of Technology.
Cell segregation and lysis have profound effects on the growth of Escherichia coli in high cell density fed batch cultures.
Biotechnol Prog, (2):190-195 1996
MED: 8857187
Flow cytometry and cell sorting of heterogeneous microbial populations: the importance of single-cell analyses.
Microbiol Rev, (4):641-696 1996
MED: 8987359
Title not supplied
J Appl Chem 1968
Title not supplied
Appl Microbiol Biotechnol 1987
Detection and discrimination of individual viruses by flow cytometry.
J Histochem Cytochem, (1):350-352 1979
MED: 374599
Show 10 more references (10 of 26)
Citations & impact
Impact metrics
Citations of article over time
Article citations
Monitoring microbial communities' dynamics during the start-up of microbial fuel cells by high-throughput screening techniques.
Biotechnol Rep (Amst), 21:e00310, 26 Jan 2019
Cited by: 5 articles | PMID: 30805299 | PMCID: PMC6374581
Proteomic study uncovers molecular principles of single-cell-level phenotypic heterogeneity in lipid storage of Nannochloropsis oceanica.
Biotechnol Biofuels, 12:21, 04 Feb 2019
Cited by: 4 articles | PMID: 30740142 | PMCID: PMC6360718
Population heterogeneity in microbial bioprocesses: origin, analysis, mechanisms, and future perspectives.
Bioprocess Biosyst Eng, 41(7):889-916, 14 Mar 2018
Cited by: 23 articles | PMID: 29541890
Review
A pipeline for developing and testing staining protocols for flow cytometry, demonstrated with SYBR Green I and propidium iodide viability staining.
J Microbiol Methods, 131:172-180, 31 Oct 2016
Cited by: 23 articles | PMID: 27810378
Reevaluating multicolor flow cytometry to assess microbial viability.
Appl Microbiol Biotechnol, 100(21):9037-9051, 29 Sep 2016
Cited by: 26 articles | PMID: 27687990
Review
Go to all (41) article citations
Similar Articles
To arrive at the top five similar articles we use a word-weighted algorithm to compare words from the Title and Abstract of each citation.
Studies related to the scale-up of high-cell-density E. coli fed-batch fermentations using multiparameter flow cytometry: effect of a changing microenvironment with respect to glucose and dissolved oxygen concentration.
Biotechnol Bioeng, 70(4):381-390, 01 Nov 2000
Cited by: 62 articles | PMID: 11005920
The use of multi-parameter flow cytometry to compare the physiological response of Escherichia coli W3110 to glucose limitation during batch, fed-batch and continuous culture cultivations.
J Biotechnol, 75(2-3):251-264, 01 Oct 1999
Cited by: 56 articles | PMID: 10553662
The use of flow cytometry to study the impact of fluid mechanical stress on Escherichia coli W3110 during continuous cultivation in an agitated bioreactor.
Biotechnol Bioeng, 59(5):612-620, 01 Sep 1998
Cited by: 24 articles | PMID: 10099379