Abstract
Temperature is the most frequently measured physical quantity, second only to time. Infrared (IR) technology has been utilized successfully in astronomy (for a summary, see Hermans-Killam, 2002b) and in industrial and research settings (Gruner, 2002; Madding, 1982, 1989; Wolfe & Zissis, 1993) for decades. However, fairly recent innovations have reduced costs, increased reliability, and resulted in noncontact IR sensors offering mobile, smaller units of measurement (EOI, 2002; Flir, 2000, 2001, 2002). The advantages of using IR imaging are (1) rapidity in the millisecond range, facilitating measurement of moving targets, (2) noncontact procedures, allowing measurements of hazardous or physically inaccessible objects, (3) no interference and no energy lost from the target, (4) no risk of contamination, and (5) no mechanical effect on the surface of the object. All these factors have led to IR technology’s becoming an area of interest for new kinds of applications and users. In both manufacturing and quality control, temperature plays an important role as an indicator of the condition of a product or a piece of machinery (EOI, 2002; Flir, 2000, 2001, 2002; Raytek, 2002). In medical and veterinary applications, IR thermometry is increasingly used in organ diagnostics, in the evaluation of sports injuries and the progression of therapy, in disease evaluation (e.g., breast cancer, arthritis, and SARS; Flir, 2003), and in injury and inflammation examinations in horses, livestock (Tivey & Banhazi, 2002), and zoo animals (Hermans-Killam, 2002a; Thiesbrummel, 2002). Lastly, physiological expressions of life processes in animals (Kastberger, Winder, & Steindl, 2001; Stabentheiner, Kovac, & Hagmüller, 1995; Stabentheiner, Kovac, & Schmaranzer, 2002; Stabentheiner & Schmaranzer, 1987) and plants (Bermadinger-Stabentheiner & Stabentheiner, 1995) can be monitored. The most recent field in which IR technology has been applied is animal behavior. This article focuses on the practical options for noncontact IR thermometry— in particular, in biological applications.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Bermadinger-Stabentheiner, E., &Stabentheiner, A. (1995). Dynamics of thermogenesis and structure of epidermal tissues in inflorescences ofArum maculatum.New Phytologists,131, 41–50.
Boldstar (2002).Boldstar infrared services helps zoo staff with ailing elephant. Retrieved November 20, 2002 from http://www.bold starinfrared.com/elephants.html.
Butler, C. G. (1962).The world of the honeybee. London: Collins.
Dauncey, M. J., &Ingram, D. L. (1983). Evaluation of the effects of environmental temperature and nutrition on growth and development.Journal of Agricultural Sciences,101, 351–358.
DeWitt, N. (1988).Theory and practice of radiation thermometry. New York: Wiley.
EOI (2002). [Electro Optical Industries, Inc. homepage]. Retrieved November 20, 2002 from http://www.electro-optical.com.
Flir (2000).Detector technology: Infrared everywhere 2000. Retrieved November 20, 2002 from http://www.flirthermography.com/english/ Default.asp.
Flir (2001).Parameters to consider when buying a research camera. Retrieved November 20, 2002 from http://www.flirthermography. com/english/Default.asp.
Flir (2002).FLIR Systems launches two revolutionary new product lines;new low cost infrared cameras will open new markets. Retrieved November 20, 2002 from http://www.corporate-ir.net/ireye/irsite. zhtml?ticker = FLIR&script = 410&layout = -6&item_id = 273820.
Flir (2003).Detecting SARS with infrared cameras. Retrieved May 2, 2003 from http://www.flirthermography.com/sarsinfraredinfo/ default.asp.
Fuchs, J. (2002).Thermography used in diagnosis of horses’ locomotor injuries [Flir publication]. Retrieved November 20, 2002 from http://www.infraredtraining.com.
Gruner, K. (2002).Principles of non-contact temperature measurement [Raytek publication]. Retrieved November 20, 2002 from http://www.raytek.com.
Hermans-Killam, L. (2002a).Infrared zoo. Pasadena, CA: California Institute of Technology, Infrared Processing and Analysis Center. Retrieved November 20, 2002 from http://sirtf.caltech.edu/EPO/Zoo/ zoo.html.
Hermans-Killam, L. (2002b).What is infrared? Pasadena, CA: California Instituteof Technology, Infrared Processing and Analysis Center. Retrieved November 20, 2002 from http://www.ipac.caltech.edu/ Outreach/Edu/infrared.html.
Janos (2002).AMTIR-1. Retrieved November 20, 2002 from http://www. janostech.com/techinfo/amtir.html.
Kastberger, G., &Biswas, S. (1998). Mechanisms in the cascadic alarming response of a giant honeybee colony.Zoology,101, 48.
Kastberger, G., &Sharma, D. K. (2000). The predator-prey interaction between blue-bearded bee eaters (Nyctyornis athertoni) and giant honeybees (Apis dorsata).Apidologie,31, 727–736.
Kastberger, G., Winder, O., Biswas, S., &Raspotnig, G. (1998). Evidence of Nasonov scenting in colony defence of the giant honeybee.Apis dorsata. Ethology,104, 27–37.
Kastberger, G., Winder, O., &Steindl, K. (2001). Defence strategies in the giant honeybeeApis dorsata [Scientific documentary film, 23 min. produced by epo-film Wien-Graz].Proceedings of the Deutsche Zoologische Gesellschaft,94, 7.
Kloft, W., &Schneider, P. (1969). Gruppenverteidigungsverhalten bei wildlebenden Bienen (Apis cerana Fabr) in Afghanistan.Naturwissenschaften,56, 219.
Kodak (2002).Infrared photography—Technical applications. Retrieved August 26, 2003 from http://www.kodak.com/global/en/ service/scienceFair/infraredTechnical.shtml.
Koeniger, N., &Fuchs, S. (1975). Zur Kolonieverteidigung der asiatischen Honigbienen.Zeitschrift für Tierpsychologie,37, 99–106.
Lindauer, M. (1956). Über die Verständigung bei Indischen Bienen.Zeitschrift für Vergleichende Physiologie,38, 521–557.
Madding, R. P. (1982). Science behind thermography: Thermal infrared sensing for diagnostics and control. In G. E. Courville (Ed.),Thermosense V (Proceedings of SPIE, Vol. 371, pp. 2–9). Bellingham, WA: SPIE Press.
Madding, R. P. (1989). Infrared thermography. In E. C. Guyer (Ed.),Handbook of applied thermal design: Pt. 12. Thermal sensors (pp. 12–57 to 12–70). New York: McGraw-Hill.
Madding, R. P. (2002).Emissivity measurement and temperature correction accuracy considerations. Retrieved November 20, 2002 from http://www.flir.com.
Morse, R. A., &Laigo, F. M. (1969).Apis dorsata in the Philippines. Laguna, The Philippines: Philippines Association of Entomologists.
Night Vision Goggles Dot Com (2002).About us. Dewitt, LA: Author. Available from http://www.mght-vision-goggles.com/about_us.html.
Qno, M., Igarashi, T., Qhno, E., &Sasaki, M. (1995). Unusual thermal defence by a honeybee against mass attack by hornets.Nature,377, 334–336.
Orlove, G. L. (2002).A primer on infrared thermography. Pasadena, CA: California Institute of Technology, Infrared Processing and Analysis Center. Retrieved November 20, 2002 from http://www.ipac. caltech.edu/Outreach/Edu/infrared.html.
Raytek (2002).Noncontact infrared temperature measurement. Retrieved November 20, 2002 from http://www.raytek.com.
Roepke, W. (1930). Beobachtungen an indischen Honigbienen insbesondere anApis dorsata.Mededelingen van de Landbouwhoogeschool Wageningen,34, 1–28.
Seeley, T. D., Seeley, R. H., &Akratanakul, P. (1982). Colony defence strategies of the honey bees in Thailand.Ecological Monographs,52, 43–63.
SPI (2002).Horses infrared veterinary medicine equine treatment. Retrieved November 20, 2002 from http://infra-red.hypermart.net/ equine_infrared_veterinary_imagi.htm.
Stabentheiner, A., Kovac, H., &Fiagmüller, K. (1995). Thermal behaviour of round and wagtail dancing honeybees.Journal of Comparative Physiology B,165, 433–444.
Stabentheiner, A., Kovac, H., &Schmaranzer, S. (2002). Honeybee nestmate recognition: The thermal behaviour of guards and their examinees.Journal of Experimental Biology,205, 2637–2642.
Stabentheiner, A., &Schmaranzer, S. (1987). Thermographic determination of body temperatures in honeybees and hornets: Calibration and applications.Thermology,2, 563–572.
Stahl, M. (1980). Grundlagen Infrarotteknik. Heidelberg: Hütthig Verlag.
Steketee, J. (1973). Spectral emissivity of skin and pericardium.Physiological & Medical Biology,18, 686–694.
Thiesbrummel, J. (2002).IR thermography with zoo animals: First experiences in the use of pregnant and inflammation diagnostics. Retrieved November 20, 2002 from http://www.infraredtraining.com.
Tivey, D., & Banhazi, T. (2002).The potential to assess environmental conditions within pig production systems. University of Adelaide, Roseworthy Campus, Livestock Systems Alliance.
Trinkel, M., & Kastberger, G. (2003).Interactions between spotted hyenas and lions in the Etosha National Park, Namibia. Manuscript submitted for publication.
Watmough, D. J., &Oliver, R. (1968). Emissivity of human skin in vivo between 2.0μ and 5.4μ measured at normal incidence.Nature,218, 885–886.
Wolfe, W. L., &Zissis, G. J. (Eds.) (1993).The infrared handbook. Washington, DC: Office of Naval Research.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kastberger, G., Stachl, R. Infrared imaging technology and biological applications. Behavior Research Methods, Instruments, & Computers 35, 429–439 (2003). https://doi.org/10.3758/BF03195520
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.3758/BF03195520