Nothing Special   »   [go: up one dir, main page]

single-rb.php

JRM Vol.31 No.6 pp. 863-870
doi: 10.20965/jrm.2019.p0863
(2019)

Development Report:

Visualization of Voids Between Tile and Concrete by Multi-Layered Scanning Method with Electromagnetic Waves

Takumi Honda*1, Takayuki Tanaka*2, Satoru Doi*3, Shigeru Uchida*3, and Maria Q. Feng*4

*1National Institute of Technology, Kushiro College
2-32-1 Otanoshike-nishi, Kushiro-shi, Hokkaido 084-0916, Japan

*2Hokkaido University
Kita 14, Nishi 9, Kita-ku, Sapporo, Hokkaido 060-0814, Japan

*3Obayashi Corporation
4-640 Shimokiyoto, Kiyose-shi, Tokyo 204-8558, Japan

*4Columbia University
500 West 120th Street, New York, NY 10027, USA

Received:
June 7, 2019
Accepted:
September 18, 2019
Published:
December 20, 2019
Keywords:
computational intelligence, multi-layered scanning, evolutionary computing
Abstract

The tiles that are used to protect the exterior of a building may separate from the concrete substrate and fall off as they age. To prevent accidents, a tiled wall can be inspected using various methods. In this study, nondestructive inspection (NDI) with microwave electromagnetic waves (EMWs) is used for detecting tile separation, and the chance of detecting the separation by this method is discussed in this paper. Here, the inspection apparatus is used to detect voids in concrete, including voids that simulate tile separation. An antenna attached to the apparatus transmits and receives microwaves to obtain a reflected intensity from the concrete. In addition, the distribution of reflected intensity is obtained using a proposed scanning method, multi-layered scanning. This involves several scans along the concrete surface at different antenna-to-surface distances. Typically, EMWs have to be analyzed with an expensive network analyzer in the time or frequency domain. However, we demonstrate that voids are detected from the obtained distribution of the reflected intensity of EMWs measured by a simple device without a network analyzer. The proposed method of NDI with EMWs is cheaper and simpler than conventional inspection methods.

Inspection apparatus

Inspection apparatus

Cite this article as:
T. Honda, T. Tanaka, S. Doi, S. Uchida, and M. Feng, “Visualization of Voids Between Tile and Concrete by Multi-Layered Scanning Method with Electromagnetic Waves,” J. Robot. Mechatron., Vol.31 No.6, pp. 863-870, 2019.
Data files:
References
  1. [1] F. Inoue, S. Doi, and Y. Ohta, “Development of automated inspection robot and diagnosis method for tile wall separation by wavelet analysis,” Proc. of 2009 26th Int. Symp. on Automation and Robotics in Construction (ISARC), pp. 379-388, 2009.
  2. [2] M. M. Islam, H. Yamamoto, and S. Tanaka, “Non-Destructive Inspection of Multiple Concrete Cracks Using Ultrasonic Sensor,” Proc. of 2006 SICE-ICASE Int. Joint Conf., pp. 5797-5802, 2006.
  3. [3] Y. Takada, Y. Tokura, Y. Matsumura, T. Tanaka, and T. Kanada, “Wall Inspection Robot with Maneuvering Assist Control System Against Crosswind,” J. Robot. Mechatron., Vol.30, No.3, pp. 416-425, 2018.
  4. [4] X. Xu, T. Xia, A. Venkatachalam, and D. Huston, “Development of high-speed ultrawideband ground-penetrating radar for rebar detection,” J. of Engineering Mechanics, Vol.139, No.3, pp. 272-285, 2012.
  5. [5] Y. J. Kim, L. Jofre, F. De Flaviis, and M. Q. Feng, “Microwave reflection tomographic array for damage detection of civil structures,” IEEE Trans. on Antennas and Propagation, Vol.51, No.11, pp. 3022-3032, 2003.
  6. [6] K. Arunachalam, V. R. Melapudi, L. Udpa, and S. S. Udpa, “Microwave NDT of cement-based materials using far-field reflection coefficients,” NDT and E Int., Vol.39, No.7, pp. 585-593, 2006.
  7. [7] R. Zoughi and S. Bakhtiari, “Microwave nondestructive detection and evaluation of voids in layered dielectric slabs,” Research in Nondestructive Evaluation, Vol.2, No.4, pp. 195-205, 1990.
  8. [8] M. Q. Feng, Y. J. Kim, and K. Park, “Real-Time and Hand-Held Microwave NDE Technology for Inspection of FRP-Wrapped Concrete Structures,” FRP Int.-The Official Newsletter of the Int. Institute for FRP in Construction, Vol.3, No.2, pp. 2-5, 2006.
  9. [9] J. Li and C. Liu, “Noncontact detection of air voids under glass epoxy jackets using a microwave system,” Subsurface Sensing Technologies and Applications, Vol.2, No.4, pp. 411-423, 2001.
  10. [10] M. Q. Feng, F. De Flaviis, and Y. J. Kim, “Use of microwaves for damage detection of fiber reinforced polymer-wrapped concrete structures,” J. of Engineering Mechanics, Vol.128, No.2, pp. 172-183, 2002.
  11. [11] S. Kawataki, T. Tanaka, S. Doi, S. Uchida, and M. Q. Feng, “Nondestructive In-spection of Voids in Concrete by Multi-layered Scanning Method with Electro-magnetic Waves,” Proc. of the IEEE Int. Conf. on MECHA-TRONICS (IEEE-ICM2017), pp. 336-341, 2017.

*This site is desgined based on HTML5 and CSS3 for modern browsers, e.g. Chrome, Firefox, Safari, Edge, Opera.