- Research
- Open access
- Published:
Choice of refractive surgery types for myopia assisted by machine learning based on doctors’ surgical selection data
BMC Medical Informatics and Decision Making volume 24, Article number: 41 (2024)
Abstract
In recent years, corneal refractive surgery has been widely used in clinics as an effective means to restore vision and improve the quality of life. When choosing myopia-refractive surgery, it is necessary to comprehensively consider the differences in equipment and technology as well as the specificity of individual patients, which heavily depend on the experience of ophthalmologists. In our study, we took advantage of machine learning to learn about the experience of ophthalmologists in decision-making and assist them in the choice of corneal refractive surgery in a new case. Our study was based on the clinical data of 7,081 patients who underwent corneal refractive surgery between 2000 and 2017 at the Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences. Due to the long data period, there were data losses and errors in this dataset. First, we cleaned the data and deleted the samples of key data loss. Then, patients were divided into three groups according to the type of surgery, after which we used SMOTE technology to eliminate imbalance between groups. Six statistical machine learning models, including NBM, RF, AdaBoost, XGBoost, BP neural network, and DBN were selected, and a ten-fold cross-validation and grid search were used to determine the optimal hyperparameters for better performance. When tested on the dataset, the multi-class RF model showed the best performance, with agreement with ophthalmologist decisions as high as 0.8775 and Macro F1 as high as 0.8019. Furthermore, the results of the feature importance analysis based on the SHAP technique were consistent with an ophthalmologist’s practical experience. Our research will assist ophthalmologists in choosing appropriate types of refractive surgery and will have beneficial clinical effects.
Introduction
Myopia is characterised by high prevalence, low age, and rapid progression, making it a global public health problem. In recent years, corneal refractive surgery has been widely used in clinics as an effective means to restore vision and improve the quality of life. Many clinical and basic experimental studies confirmed its safety [1], effectiveness, stability, and predictability [2].
Currently, frame lenses, contact lenses, corneal refractive surgery, and intraocular lens implant surgery are the main methods to correct refractive errors. The principle is to correct the light entering the human eye by diverging it and focusing it on the retina. For teenagers whose eyeballs are not fully developed and whose refractive power is unstable, or for patients who cannot undergo surgery, refractive correction is mainly done by wearing glasses, contact lenses, phakic IOL implantation [3], or vision rehabilitation training. For adults who meet the criteria for laser vision correction surgery, correction can be achieved through corneal refractive surgery or intraocular lens surgery. At present, the corneal refractive surgeries clinically used in my country include laser in situ keratectomy (LASIK), laser photo keratectomy (PRK), and SMall Incision Lenticule Extraction (SMILE). The diversification of surgical methods has brought new surgical techniques, outcomes, and options to patients and operators, as well as improved surgical outcomes, safer surgical procedures, and fewer surgical complications.
Since the first reported case of corneal dilatation after refractive surgery [4], the safety of refractive surgery has attracted the attention of physicians. Because the operation changes the normal anatomical structure of the cornea, there may be complications such as epithelial or corneal stroma opaque bubbles, difficulty in opening the corneal flap, postoperative transient photosensitivity syndrome, and incomplete lens removal during femtosecond laser surgery [5]. Corneal flap abnormality, displacement, folds, postoperative epithelial implantation, and other special circumstances may occur during and after surgery [6]. Complications of postoperative myopia itself, such as fundus hemorrhage, retinal degeneration, retinal detachment, and glaucoma, may still occur [7]; Postoperative complications may also occur, such as refractory dry eye, decreased scotopic vision, phantom vision, ghosting, glare [8]. It is also possible that reoperation is required because of deviations in the surgical type or parameters. Therefore, ophthalmologists must be cautious in screening patients reasonably, scientifically, and rationally before surgery and choose the most suitable surgical method for patients to achieve ideal surgical results and reduce surgical risks.
Some studies have used artificial intelligence to assist decision-making in myopia corneal refractive surgery [9,10,11,12,13]. Among them, Balidis M et al. [12] utilized neural networks to predict the need for retreatment after refractive surgery for myopia, achieving statistically significant predictions with good sensitivity (0.8756) and specificity (0.9286). Melles RB et al. [13] proved that artificial intelligence is more helpful in the calculation of the refractive IOL degree and the quantification of the position in intraocular refractive surgery. The datasets of these researches typically have a short time span and only contain a limited set of surgical types. In our study, we used machine learning to learn about the experience of ophthalmologists in decision-making and assist them in the choice of corneal refractive surgery in a new case. Our research was based on the data of 7,081 patients who underwent surgery at the Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences between 2000 and 2017. The patients were divided into three groups according to the type of surgery performed: LASIK, PRK, and SMILE. Our research explored how to perform data preprocessing, feature selection, and machine learning model training to achieve the best prediction performance. The contributions of this study are as follows:
-
1.
Aiming at the preprocessing of ophthalmology data, we provided data cleaning, feature selection, as well as a small number of oversampling techniques (SMOTE) to deal with the data imbalance problem in the experimental data.
-
2.
We selected and trained six statistical machine learning models, including the Naive Bayesian Model (NBM), Random Forest (RF), Adaptive Boosting (AdaBoost), eXtreme Gradient Boosting (XGBoost), Back Propagation Neural Network (BP Neural Network), and Deep Belief Network (DBN), and used ten-fold cross-validation and grid search to find the optimal hyperparameters to improve the accuracy of the classification model. When tested on the dataset, the multi-class RF model showed the best performance, with agreement with ophthalmologist decisions as high as 0.8775 and Macro F1 as high as 0.8019. The model results showed that the model had good clinical application value.
-
3.
To verify the rationality of feature selection, we used SHAP [14] to quantify the importance of features. The results were highly consistent with the practical experience of ophthalmologists. Ultimately, the developed model is able to provide confidence to doctors and patients by recommending surgery based on data when deciding on a surgical method.
Related work
Since 1970, artificial intelligence (AI) research has made certain breakthroughs in the medical field, and a series of clinical decision support models have been used in the diagnosis of ophthalmic diseases and the choice of treatment options, which can involve retinal images, optical coherence tomography (OCT), slit lamp images and other data that can be automatically analysed and applied to glaucoma [15, 16], age-related macular degeneration [17], cataract [18], Keratoconus [19], dry eye disease [20] screening for eye diseases, diabetic retinopathy [21], diabetic peripheral neuropathy [22] and auxiliary diagnosis of ocular manifestations such as systemic diseases [23]. In refractive surgery, the advantages of AI mainly focus on keratoconus screening, selection of refractive surgery options, design of surgical parameters (nomogram), postoperative efficacy prediction, and implantable intraocular lens implantation in phakic eyes. Collamer lens (ICL) postoperative arch height prediction and other aspects have also been explored [24,25,26,27,28].
In the clinical practice of refractive surgery, Yoo TK et al. [29] established a machine learning architecture that combines a large number of different instrument data from patients and the clinical decisions of experienced experts to analyse the possible impact on surgical results, to identify surgical candidates and avoid surgical complications that may happen. In addition, Achiron A et al. [30] extracted 38 clinical parameters from the case data of 17,592 patients who underwent LASIK or PRK surgery in an ophthalmology department for 12 consecutive years and used the statistical classifier algorithm to train and test the machine learning classifier. The study found that surgical effectiveness decreased with age, central corneal thickness, average corneal curvature, and preoperative CDVA, but increased with pupil size. Cui T et al. [31] used 1,146 eye sample data and the MLPNN algorithm to construct a Nomogram prediction model for SMILE surgery based on machine learning algorithms and compared the ML model with clinical experts. There were no significant differences; however, the ML group was superior to the clinical expert group in terms of efficacy and predictability. The postoperative spherical equivalent dioptres of the ML group and the clinical expert group are -0.09 ± 0.024 and -0.23 ± 0.021, respectively.
Yoo TK et al. [32] developed an interpretable multi-category XGBoost model for the expert-level choice of refractive surgery, classifying patients into four types: laser epithelial keratopathy, laser in situ keratopathy, small-incision lens extraction, and contraindications. The analysis included 18,480 subjects and 142 variables, and the model achieved accuracies of 81.0% and 78.9% when tested on the internal and external validation datasets, respectively. Our study verified the results of the paper conducted by Yoo TK et al. [32], but this study has the following differences and improvements: (1) Aiming at the preprocessing of ophthalmology data, we provided data cleaning, feature selection, as well as a small number of oversampling techniques (SMOTE) to deal with the data imbalance problem in the experimental data. (2) For the selection of machine learning models, we investigated 15 mainstream machine learning models in the early stage. We finally selected and trained six statistical machine learning models, including the NBM, RF, AdaBoost, XGBoost, BP Neural Network, and DBN, and used ten-fold cross-validation and grid search to find the optimal hyperparameters to improve the accuracy of the classification model. (3) Our data set Clinical data was collected from patients who underwent corneal refractive surgery at the Peking Union Medical College Hospital of the Chinese Academy of Medical Sciences from January 2000 to October 2017. The time span is very long, more than 18 years. Combined with the previous examination methods, which were very limited, the well-preserved data and conducting research is of great cross-epochal significance. (4)In our experiments, it was discovered and verified that the feature of “sphere-column conversion” had a certain degree of influence on the predicted results of the surgical method, which has new clinical application value.
The theory and technology of corneal refractive surgery are becoming increasingly perfect; however, there are still problems such as preoperative screening difficulties and postoperative complications in clinical practice, and the safety and accuracy of surgery still need to be further improved. In addition, due to the lack of data transparency, it is impossible to critically evaluate the quality of the model [33]. There are various sources of clinical data for building AI models, and there is no unified standard, which also limits the development of AI [34]. When the diagnosis and treatment opinions of the disease are inconsistent, the accuracy of AI prediction is affected. Due to the black-box nature of the algorithm, the previous AI model cannot make a reasonable explanation for the decision-making like human experts [35]. However, this study uses visualization technology to explain the results of the multi-classification RF algorithm. The developed model can recommend surgeries based on data when deciding on surgical methods. The consistency with the clinical decision-making of ophthalmologists is as high as 87.75%, providing confidence to doctors and patients.
Data preparation
The dataset for this study was obtained from the clinical data of patients who underwent corneal refractive surgery at the Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, from January 2000 to October 2017, and all data have been desensitized. This study was approved by the Ethics Review Committee of Peking Union Medical College Hospital, Chinese Academy of Medical Sciences. All methods were carried out in accordance with relevant guidelines and regulations in the Declaration of Helsinki. All participants signed an informed consent. At this ophthalmic centre, corneal refractive surgery is considered the main method of refractive error correction.
Previous studies have shown that Reinstein DZ et al. [36] found that the postoperative TTS is considerably higher after SMILE than both PRK and LASIK, because the strongest anterior lamellae remains intact. Consequently, SMILE should be able to correct higher levels of myopia. Xin Y et al. [37] found that the corneal biomechanical response to the three surgical procedures varied significantly. With similar corneal thickness loss, the reductions in overall corneal stiffness were the highest in FS-LASIK and the lowest in tPRK. The effective remaining corneal volume of different corneal refractive surgeries (such as LASIK, PRK, SMILE) is different and their biomechanical properties are different. Based on previous research and combined with the surgical experience of senior experts from Union Medical College, we added the criteria for whether laser vision correction surgery is feasible into the model training by hand-crafted rules. First, patients who could not undergo refractive surgery were excluded. The exclusion criteria included corneal diseases, such as keratoconus and corneal dilation disease; autoimmune diseases; systemic model diseases or partial metabolic diseases, such as severe hyperthyroidism or hyperthyroid exophthalmos; and active eye lesions, such as intraocular and corneal infections; poor fundus function, or severe cataract, glaucoma and other eye diseases; diabetes mellitus; cicatricial constitution; data loss >10%; refusing surgery during or after the examination.
All patients who pass the above screening are required to undergo strict eye examination before surgery. The preoperative examination and main instruments include: automatic computer refraction (Topcon, RM-800, Japan); Subjective refractor (Topcon, CV-5000, Japan) measured distance uncorrected visual acuity and distance corrected visual acuity; non-contact intraocular pressure measurement (Canon, TX-20, Japan); A fully automatic non-contact tonometer (TXF, Canon Company, Japan) was used to measure intraocular pressure, and a slit lamp microscope (BQ900, HAAG-STREIT Company, Switzerland) was used for examination; Corneal topography (Oculus, Pentacam, Germany) examination; ocular wavefront aberrometer (Visx4, United States), all the above examinations were completed by the same experienced optometrist. Doctors conduct a preliminary screening of surgical methods according to simple criteria. General criteria for considering surgery include the following parameters: age 18 years or older; preoperative diopter: spherical diopter (SD) \(\le\) -9.00 diopters (D), astigmatism (CD) \(\le\) -3.00D, and the diopter is in a stable state within 2 years; intraocular pressure (IOP): 10-21mmHg; spherical equivalent < +6.0D; central corneal thickness (CCT) measured by pachymetry is required, >500\(\mu\)m for LASIK, >480\(\mu\)m for SMILE and >460\(\mu\)m for PRK; and surgery posterior residual corneal thickness >280\(\mu\)m.
Subsequently, this study used the following expert knowledge and added them to the training of the model in the form of hand-crafted rule: for patients with thin corneas and high refractive power, PRK is preferred [38]; SMILE is not recommended for patients with high astigmatism [39]; SMILE is not recommended for patients with irregular corneas; Myopic patients with a history of high intraocular pressure or glaucoma should avoid superficial surgery; patients with severe dry eye should avoid LASIK surgery. The type of surgery is determined based on the surgical experience and actual situation of senior experts from the Chinese Academy of Medical Sciences and Peking Union Medical College. And using machine learning methods to learn and combine various judgment factors to ultimately determine the type of refractive corneal surgery that is most suitable for each eye. It should be noted that those who could not be corrected all at once because of high myopia and insufficient corneal thickness needed to maintain a certain degree of vision, and were required to wear glasses after surgery to achieve the best vision.
At least we got the dataset with the clinical data of 7,081 patients. In the dataset, there are three situations: the same operation is performed on both eyes simultaneously, different operations are performed on both eyes simultaneously, and the operation is performed on one eye. In the end, we obtained a total of 13,723 pieces of data in the data set, including 6,872 left-eye data and 6,851 right-eye data. The model predicted the left eye and right eye respectively.
As shown in Table 1, three types of laser corneal refractive surgeries are currently mainstream for correcting refractive errors, all of which have good predictability and safety. Among them, LASIK, PRK, and SMILE can perform individualised ablation guided by wavefront aberration, Q value, and corneal topography, which are beneficial for improving the visual quality of patients [40]. The most commonly used surgical methods are LASIK and SMILE. This is because LASIK technology is very mature, has been practiced for many years, has a very good reputation, and doctors have a wealth of experience. Furthermore, SMILE represents the latest development in the field of corneal refractive surgery and is the most popular surgery in recent years. The clinical implementation time is relatively short; however, it has completely realised the leap of minimally invasive and flapless refractive surgery [41], avoiding potential risks such as corneal flap folds, displacement and loss, and bringing corneal refractive surgery into the era of femtoseconds [42].
Table 2 shows twenty attributes for patients which were extracted from demographic characteristics, physical examination report, corneal biomechanical properties, ophthalmological measurements and interview questionnaire, etc, namely fBestEye (Vision with glasses), fNudeEye (Vision without glasses), Central Corneal Thickness, Intraocular Pressure, DS Spherical Power, DC Cylinder Power, fDS3 (Cylinder Axis), Re-examination Optometry, fDC2 (Recheck Cylinder), fDC3 (Recheck Axis), Pupil, Dilated Pupil, Sphere-column Conversion, Corneal Curvature K1, Axis K1, Corneal Curvature K1, Axis K2, fSRI (Surface Regularity Index), fSAI (Corneal Asymmetry Index), and fCSI (Corneal Spherical Aberration). Among them, Sphere-column Conversion = spherical equivalent refraction * astigmatism / 2. These attributes help us determine which type of refractive surgery is selected as the best one for an eye. Due to the fact that the data in this paper is divided into three categories, the comparison was conducted using the Kruskal-Wallis test, with P<0.05 indicating a statistically significant difference.
Experiments and discussion
In this section, we present our experimental methods and conclusions, including the data preprocessing, predictive model selection and training, and feature importance analyses.
Data preprocessing
Owing to the features of irregularity, high dimensionality, redundancy, and data loss in our dataset, a series of preprocessing steps were performed on the original data before data mining, including 1) data cleaning to identify outliers and duplicates and 2) deleting cases lacking key values.
The experimental data used in our study had multiple features, each with different dimensions and dimension units. Differences in the magnitude of the feature data can affect the performance of the model. For example, features at different scales may lead the model to pay more attention to features with larger values, thus ignoring other important features and leading to a decrease in its predictive performance. Therefore, we further standardized and normalized the data to increase the solution speed of the gradient descent and eliminate the influence of the magnitude and dimension, thereby improving the convergence speed and accuracy of the prediction model. Standardization refers to Z-core normalization, which enables the values of all features to be converted into a normal distribution with a mean of zero and a standard deviation of one. Normalization refers to min-max scaling, which converts each feature value into a [0,1] interval. For each feature, the minimum and maximum values were converted to 0 and 1, respectively. Deviation standardization can transform data into different proportions, eliminate the dominance of special features, and does not require assumptions regarding the distribution of data. However, normalization cannot handle outliers. In contrast, standardization can better handle outliers and accelerate the convergence of algorithms, such as gradient descent. This study selected the optimal data preprocessing method by comparing the classification effects of standardization and normalization.
Our experimental data showed an imbalance in the number of cases for the three surgical methods. Among them, LASIK had the largest number of cases (9,096), and PRK had the smallest number of cases (1,991). In this study, a synthetic minority oversampling technique (SMOTE) [14] was adopted to overcome the imbalance problem. The SMOTE method is an oversampling method that randomly generates new instances of minority classes to balance the number of classes and is the most popular and effective method for balancing the dataset during training. When generating binary variables (gender or yes/no questionnaire) using SMOTE, a rounding function was applied after the SMOTE process to restore the binary variable attributes. Subsequently, a fully balanced dataset was generated using the SMOTE technique, such that the surgical modalities in the experimental data had the same number of instances.
Model training
In our study, the choice of surgical type was regarded as a classification problem, and the aim was to develop an optimal classification model based on the dataset. Six statistical machine learning methods, namely NBM, RF, AdaBoost, XGBoost, BP neural network, and DBN were selected. The dataset was randomly divided into training (80%, n=10978) and testing (20%, n=2745). Ten-fold cross-validation and grid search are used to find the optimal hyperparameters, and then SMOTE is used for oversampling in each cross-validation cycle to ensure the accuracy of the validation results. In the experiment, feature selection refers to selecting the first 12 features with feature importance greater than 0.4 for model training. We conducted model training by conducting two sets of comparative experiments on the left and right eyes respectively through feature selection and max_depth parameter selection.
The six machine learning models are based on different design concepts and technical principles. The settings of the public parameters in the model are as follows, the random seed is set to 1, the number of iterations max_iter is set to 1000, and the activation function of the hidden layer is set to relu.
-
1.
The NBM [46] model, which classifies by calculating probability, is suitable for multi-classification tasks and incremental training. For large-scale data, the computational complexity is low, and the algorithm principle is relatively simple and easy to understand.
-
2.
The RF [47] model combines the classification results of several weak classifiers to form a strong classifier. It can evaluate the importance of each feature in the classification problem, can effectively run the input samples of high-dimensional features, does not require dimensionality reduction, has excellent accuracy, and can also obtain good results for missing value problems.
-
3.
The AdaBoost [48] model is an iterative algorithm. Its core idea is to train different classifiers (weak classifiers) for the same training set, and then combine these weak classifiers to form a stronger final classifier (strong classifier).
-
4.
XGBoost [49] is an improvement to the gradient boosting algorithm. Newton’s method is used to solve the extreme value of the loss function, and the loss function Taylor is expanded to the second order. In addition, a regularization term is added to the loss function.
-
5.
The BP neural network [50] model has arbitrarily complex pattern classification capabilities and excellent multi-dimensional function mapping capabilities, and solves XOR and some other problems that simple perceptrons cannot solve.
-
6.
The DBN [51] model is a hybrid model composed of a restricted Boltzmann machine (RBM) and a sigmoid belief network (SBN). Compared with the neural network of the traditional discriminant model, it establishes a joint distribution between observation data and labels, in which Both P (Observation | Label) and P (Label | Observation) are evaluated.
Experiment results
We use the currently recognized general indicator accuracy [52] and Macro-F1 as indicators for evaluating model performance. Accuracy is defined as the percentage of samples correctly classified by the prediction model in all samples, reflecting the ability of the prediction model to identify if various samples and the formula is shown in (1), where TP(True Positives) represents the number of correct predictions for positive samples, TN(True Negatives) represents the number of correct predictions for negative samples, and N represents the total number of samples.
The Macro-F1 reflects the model’s performance in multi-category classification tasks, especially when dealing with imbalanced category distributions. It measures the model’s ability to recognize each category and calculates the weighted average of its precision and recall across all categories, as shown in formulas (2) and (3):
The Macro-F1 is calculated using formula (4):
Data preprocessing and experimental results
As mentioned earlier, the data processing stage includes data cleaning, SMOTE technology, and feature selection. Among them, the SMOTE [53] method is used to deal with the data imbalance problem by randomly generating new instances of a minority class. Feature selection is performed by selecting the top 12 features with importance greater than 1.4%. In this section, we conduct multiple comparative experiments to verify the effectiveness of the hyperparameter max_depth and feature processing on classification performance. Tables 3 and 4 show the performance of the machine learning model predictions for the left and right eyes, respectively, ACC and Macro-F1.
From Tables 3 and 4, it can be seen that:
-
(1)
According to the results of the two sets of comparative experiments, the best method is to select the first 12 features with feature importance greater than 1.4% and the RF model trained when max_depth=10. The accuracies of the left eye and right eye are 0.8775 and 0.8229 respectively, and the Macro-F1 is 0.8019 and 0.8080 respectively. The model’s performance demonstrates its significant clinical usability. The prediction performance of the DBN model without feature selection is relatively the lowest. The accuracy of the left eye and right eye are 0.6946 and 0.7487 respectively, and the Macro-F1 is 0.5643 and 0.4657 respectively. Investigate its reason, RF is an ensemble learning method that improves generalization by combining multiple decision trees. It can handle high-dimensional data and feature interactions, reducing overfitting. Additionally, it possesses strong anti-overfitting capabilities by randomly selecting features and constructing decision trees through random sampling. Furthermore, it effectively deals with imbalanced datasets by focusing on minority class samples and provides interpretability and feature importance measurements, achieving outstanding performance in multi-class machine learning.
-
(2)
Max_depth is a key hyperparameter in the decision tree model. It can be seen that the selection of the hyperparameter max_depth has a certain impact on model training. This paper uses methods such as ten-fold cross-validation to try different max_depth values, and then select the model with the best performance on the data set. This is a common parameter adjustment method that can help us find optimal hyperparameter values. But for NBM, DBN, and BP Neural Network, the design of these models does not involve parameters such as “max_depth”, because their structure and training methods are different from other models that need to set depth or layer limit, so their training results Not affected by max_depth. It can be seen that when max_depth is 10, the effect of the machine learning model is usually better than when max_depth is 9 or 11. For the RF model, when max_depth is 10, the model accuracy of the left eye and right eye is 0.8775 and 0.8229 respectively, and the Macro F1 is 0.8019 and 0.8080 respectively. When max_depth is 9 and 11, the model accuracy of the left and right eyes is reduced by 1% and 1% on average, and Macro F1 is reduced by 4% and 3% on average. This suggests that at a maximum depth of 10, the model is better able to capture complex relationships in the training data, while a depth of 9 or 11 may be too simple or too complex, resulting in degraded performance. Choosing an appropriate max_depth is crucial for models such as random forests, which directly affects the complexity and generalization ability of the model.
-
(3)
Feature selection generally improves the performance of classification models, but there are exceptions. E.g, through the analysis of experimental results, it can be seen that NBM models are usually used to process high-dimensional data, and feature selection will reduce the number of features, thereby reducing the ability of NBM to capture complex relationships in the data. On high-dimensional data, selecting the right subset of features may become more difficult, reducing model performance.
-
(4)
Based on the results of the above comparative experiments, it can be observed that the prediction performance of the left-eye model in the proposed model was generally better than that of the right eye. We considered the order of surgical eye treatment and individual patient variability in physiological factors, such as axial length, corneal curvature, pupil size, occupation, and eye habits. Therefore, the dioptres corrected for each eyeball and the depth of the corneal cut will also vary, which will have some impact on the predictive effect of the type of surgery.
Figure 1 is a comparison chart of the ROC curves of the five classification algorithms that predict each surgical method in the data set. The ROC curve shown in Fig. 1A shows the relationship between the specificity and sensitivity of the classifier when predicting whether a patient will undergo lasik surgery, and is a comprehensive representation of the diagnostic accuracy of the classifier. For different classifiers, the larger the area under the ROC curve (AUC), the better the diagnostic performance. As can be seen from the figure, the ROC area of the RF model is the largest, and the probability of being consistent with the doctor is the highest, proving that the model has good comprehensive performance.
Feature importance and visualization
In this section, we investigate the importance of each feature for classification. In Fig. 2 the SHAP feature importance matrix graph shows the features with high importance and quantifies the impact of multiple clinical features, such as Central Corneal Thickness (0.1556), Sphere-column Conversion (0.0725), Re-examination Optometry (0.0704), DS Spherical Power (0.0643), Corneal Curvature K2 (0.0577), and Corneal Curvature K1 (0.0561). All of which play important roles in the selection of corneal refractive surgery methods. It was verified that the explanation of feature importance using SHAP techniques is consistent with the clinical diagnosis of oculists. As shown in Fig. 3, these three box plots respectively show the center position and scatter range of the data distribution of the top-3 variables in SHAP importance in each surgical method. The figure clearly and intuitively shows that there are obvious differences in the distribution of the three variables in different surgical methods.
Analysis shows the data span is more than eighteen years, and surgical techniques have innovated rapidly over time. The central corneal thickness is an important indicator in corneal refractive surgery, which to a certain extent determines the range of degrees that can be corrected by surgery, and has an important impact on the feasibility, safety, correction effect, and postoperative stability of surgery. In addition, a patient’s best vision while wearing glasses provides a baseline for physicians in assessing surgical feasibility and predicting surgical outcomes, helping them assess the potential degree of visual improvement after surgery. To a certain extent, it may have an impact on the goal setting, surgical effect prediction, and surgical type selection of corneal refractive surgery.
The interpretation of the feature importance using the SHAP technique in this study was consistent with the ophthalmologist’s practical Experience. In addition, our study also find that the new clinical indicator of sphere-column conversion (sphere-column conversion = spherical equivalent refraction * astigmatism / 2) has a certain degree of impact on the predicted results of the surgical method, which will provide ophthalmologists with a new clinical tip.
Figure 4 shows the summary plot graphs of 3 random forest classifiers, each of which gives the global interpretability of why the corresponding surgical type was chosen. In each summary plot graph, the vertical axis sorts the features based on the sum of the SHAP values of all samples, while the horizontal axis represents the SHAP value, which is the distribution of the impact of the features on the model output. Each point represents a sample. From the origin to the right, the SHAP value is positive, indicating that the contribution of the feature to the prediction result is positive. The more lines to the right, the greater the contribution, and vice versa to the left.The thicker the line, the larger the sample size, and vice versa. The color from blue to red represents the representative value from small to large. As shown in Fig. 4, for all surgical types, Central Corneal Thickness, Dilated Pupil, DS Spherical Power, and Re-examination Optometry are the most important features.
Figure 5 illustrates a single-sample prediction explanation with a force plot. In the force plot, the SHAP value of each feature is visualized as a force that increases or decreases the prediction accuracy. The red force indicates a positive contribution to the predicted result, and the blue force indicates a negative contribution to the predicted result, while the quantity of contribution is expressed as a numerical value on the x-axis. E.g Fig. 4B indicates that the positive contribution of the feature of DS Spherical Power = -4 is the largest, followed by Central Corneal Thickness = 531, Re-examination Optometry = -4, Sphere-column Conversion = -4.5, and Dilated Pupil = 5.5, but the negative contribution of fSRI(Surface Regularity Index) = 0.01. This means that, under the comprehensive influence of all features, the probability that the model predicts that PRK should be used for this case is 98%. The fSRI in the patients with PRK surgery in the data set is mainly concentrated between [0.03, 0.20], but in this case, the Corneal Curvature K2 is 0.01, which has a negative impact on the classification model.
Conclusion
In this paper, we proposed a machine learning-based prediction model for selecting corneal refractive surgery techniques. Firstly, we cleaned the data set, removed samples with missing key data, selected the top 12 features with feature importance greater than 1.4%, and solved the problem of data imbalance through SMOTE technology. Next, we selected six machine learning models and used 10-fold cross-validation and grid search to train the models and determine the optimal hyperparameters to improve model performance. The best method is to select the first 12 features with feature importance greater than 1.4% in the left eye, set max_depth to 10, and train the RF model through SMOTE, with an accuracy of 0.8775 and a Macro-F1 of 0.8019. Further, the SHAP technique is used to interpret feature importance consistent with the practical experience of ophthalmic surgeons. In our experiments, it was discovered and verified that the feature of “sphere-column conversion” had a certain degree of influence on the predicted results of the surgical method, which has new clinical application value.
In this research, 20 features including demographic characteristics, physical examination report, corneal biomechanical properties, ophthalmological measurements, and interview questionnaire were used, and 6 machine learning models were used for classifications. In further work, we will build multi-modal models to process various information including graphical data and text. At the same time, our analysis solely utilizes data from a single ophthalmic hospital, and the performance of the machine learning model may differ when applied to larger datasets with different patient features and institutions with different distributions. However, due to the limited amount of case data and the principle of confidentiality, we are unable to obtain external data. Ultimately, the developed model is able to provide confidence to doctors and patients by recommending surgery based on data when deciding on a surgical method.
The hospital’s ophthalmology department from which the data set in this study comes has high medical standards and high surgical quality, with an annual outpatient volume of more than 120,000 and an annual operation volume of more than 8,000. More than 98% of patients come to our center for review of uncorrected vision, corrected vision, subjective and objective refraction, and intraocular pressure, 1 day after surgery, 1 week after surgery, 1 month after surgery, 3 months after surgery, and 6 months after surgery. A slit lamp and other examinations were performed, and subjective refraction and dominant eye examination were performed in the 6th month after surgery. Because the time span of this study is very long, a small amount of postoperative examination data was missing, but the hospital conducted postoperative follow-up visits for all patients, and the results showed that the expected surgical results were achieved and there were no postoperative complications. This data set only records the surgical data of some doctors. These doctors have rich surgical experience and superb surgical skills, and there are no postoperative complications in this part. Data that could lead to postoperative complications were not recorded in this data set. Therefore, the failure to reflect surgical results such as postoperative complications, visual acuity, or refraction is a clear limitation of the study.
The data used in this study span a very long time span, more than 18 years. Combined with the very limited previous inspection methods, it is of great epochal significance to preserve well-preserved data and conduct research. Our next step is to obtain an external validation dataset, in order to prevent overfitting and better explore the effectiveness of the machine learning model across different institutions and surgeons.
Availability of data and materials
The datasets generated and/or analyzed during the current study are not publicly available but are available from the corresponding author upon reasonable request.
References
Ivarsen A, Asp S, Hjortdal J. Safety and Complications of More Than 1500 Small-Incision Lenticule Extraction Procedures. Ophthalmology. 2014;121(4):822–8. https://doi.org/10.1016/j.ophtha.2013.11.006.
Chansue E, Tanehsakdi M, Swasdibutra S, McAlinden C. Efficacy, predictability and safety of small incision lenticule extraction (SMILE). Eye Vis. 2015;2:1–6. https://doi.org/10.1186/1471-2415-14-117.
Choi H, Ryu IH, Lee IS, Kim JK, Yoo TK. Comparison of implantation of posterior chamber phakic IOL implantation and laser vision correction in terms of corneal endothelial cells: 3-year observational paired-eye study. J Cataract Refract Surg. 2023;49(9):936–41. https://doi.org/10.1097/j.jcrs.0000000000001246.
Seiler T, Quurke AW. Iatrogenic keratectasia after LASIK in a case of forme fruste keratoconus. J Cataract Refract Surg. 1998;24(7):1007–9. https://doi.org/10.1016/S0886-3350(98)80057-6.
Zhang J, Ren Y, Yin Y, Qi H. A Parametric Investigation of Corneal Laser Surgery Based on the Multilayer Dynamic Photothermal Model. J Biomech Eng. 2021;143(4):041003. https://doi.org/10.1115/1.4049156.
Parminder A, Jacobs DS. Advances in scleral lenses for refractive surgery complications. Curr Opin Ophthalmol. 2015;26(4):243–8. https://doi.org/10.1097/icu.0000000000000173.
Netto MV, Mohan RR, Ambrósio R, Hutcheon AEK, Zieske JD, Wilson SE. Wound healing in the cornea: a review of refractive surgery complications and new prospects for therapy. Cornea. 2005;24(5):509–22. https://doi.org/10.1097/01.ico.0000151544.23360.17.
Zafar S, Wang P, Woreta FA, Aziz K, Makary M, Ghous Z, et al. Postoperative Complications in Medicare Beneficiaries Following Endothelial Keratoplasty Surgery. Am J Ophthalmol. 2020;219:1–11. https://doi.org/10.1016/j.ajo.2020.05.033.
Carr M. Cataract, intraocular lens, and refractive surgery in 1987 with a forecast to 1995. J Cataract Refract Surg. 1988;14(6):664–7. https://doi.org/10.1016/s0886-3350(88)80037-3.
Wang Q, Fan L, Zhou Q. The best choice for low and moderate myopia patients incapable for corneal refractive surgery: implantation of a posterior chamber phakic intraocular lens. Int Ophthalmol. 2023;43(2):575–81. https://doi.org/10.1007/s10792-022-02459-3.
Gupta N, Naroo SA. Factors influencing patient choice of refractive surgery or contact lenses and choice of centre. Contact Lens Anterior Eye J Br Contact Lens Assoc. 2006;29(1):17–23. https://doi.org/10.1016/j.clae.2005.10.006.
Balidis M, Papadopoulou I, Malandris D, Zachariadis Z, Sakellaris D, Vakalis T, et al. Using neural networks to predict the outcome of refractive surgery for myopia. 4open. 2019;2:29. https://doi.org/10.1051/fopen/2019024.
Melles RB, Holladay JT, Chang WJ. Accuracy of Intraocular Lens Calculation Formulas. Ophthalmology. 2018;125(2):169–78. https://doi.org/10.1016/j.ophtha.2017.08.027.
Lundberg S, Lee SI. A Unified Approach to Interpreting Model Predictions. 2017. https://doi.org/10.48550/arXiv.1705.07874.
Li Z, He Y, Keel S, Meng W, Chang RT, He M. Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs. Ophthalmology. 2018;125(8):1199–206. https://doi.org/10.1016/j.ophtha.2018.01.023.
Lee J, Kim JS, Lee HJ, Kim SJ, Kim YK, Park KH, et al. Discriminating glaucomatous and compressive optic neuropathy on spectral-domain optical coherence tomography with deep learning classifier. Br J Ophthalmol. 2020;104(12):1717–23. https://doi.org/10.1136/bjophthalmol-2019-314330.
Liu S, Hu W, Xu F, Chen W, Liu J, Yu X, et al. Prediction of OCT images of short-term response to anti-VEGF treatment for diabetic macular edema using different generative adversarial networks. Photodiagnosis Photodynamic Ther. 2023;41:103272. https://doi.org/10.1016/j.pdpdt.2023.103272.
Liu X, Jiang J, Zhang K, Long E, Cui J, Zhu M, et al. Localization and diagnosis framework for pediatric cataracts based on slit-lamp images using deep features of a convolutional neural network. PLoS ONE. 2017;12(3):e0168606. https://doi.org/10.1371/journal.pone.0168606.
Lin SR, Ladas JG, Bahadur GG, Al-Hashimi S, Pineda R. A review of machine learning techniques for keratoconus detection and refractive surgery screening. In: Seminars in ophthalmology. Taylor & Francis; 2019. p. 317–26. https://doi.org/10.1080/08820538.2019.1620812.
Noguchi K, Saito I, Namiki T, Yoshimura Y, Nakaguchi T. Reliability of non-contact tongue diagnosis for Sjögren’s syndrome using machine learning method. Sci Rep. 2023;13(1):1334. https://doi.org/10.1038/s41598-023-27764-4.
Vujosevic S, Aldington SJ, Silva P, Hernández C, Scanlon P, Peto T, et al. Screening for diabetic retinopathy: new perspectives and challenges. Lancet Diabetes Endocrinol. 2020;8(4):337–47. https://doi.org/10.1016/s2213-8587(19)30411-5.
Salahouddin T, Petropoulos IN, Ferdousi M, Ponirakis G, Asghar O, Alam U, et al. Artificial Intelligence-Based Classification of Diabetic Peripheral Neuropathy From Corneal Confocal Microscopy Images. Diabetes Care. 2021;44(7):e151–3. https://doi.org/10.2337/dc20-2012.
Ting DSW, Pasquale LR, Peng L, Campbell JP, Lee AY, Raman R, et al. Artificial intelligence and deep learning in ophthalmology. Brit J Ophthalmol. 2019;103(2):167–75. https://doi.org/10.1016/j.aopr.2022.100078.
Siddiqui AA, Ladas JG, Lee JK. Artificial intelligence in cornea, refractive, and cataract surgery. Curr Opin Ophthalmol. 2020;31(4):253–60. https://doi.org/10.1097/icu.0000000000000673.
Lyra D, Ribeiro G, Torquetti L, Ferrara P, Machado A, Lyra JM. Computational Models for Optimization of the Intrastromal Corneal Ring Choice in Patients With Keratoconus Using Corneal Tomography Data. J Refract Surg (Thorofare, NJ : 1995). 2018;34(8):547–50. https://doi.org/10.3928/1081597x-20180615-01.
Fariselli C, Vega-Estrada A, Arnalich-Montiel F, Alio JL. Artificial neural network to guide intracorneal ring segments implantation for keratoconus treatment: a pilot study. Eye Vis (Lond Engl). 2020;7:20. https://doi.org/10.1186/s40662-020-00184-5.
Kusmakar S, Karmakar C, Zhu Y, Shelyag S, Drummond S, Ellis J, et al. A machine learning model for multi-night actigraphic detection of chronic insomnia: development and validation of a pre-screening tool. R Soc Open Sci. 2021;8(6):202264. https://doi.org/10.1098/rsos.202264.
Shen Y, Wang L, Jian W, Shang J, Wang X, Ju L, et al. Big-data and artificial-intelligence-assisted vault prediction and EVO-ICL size selection for myopia correction. Brit J Ophthalmol. 2023;107(2):201–6. https://doi.org/10.1136/bjophthalmol-2021-319618.
Yoo TK, Ryu IH, Lee G, Kim Y, Kim JK, Lee IS, et al. Adopting machine learning to automatically identify candidate patients for corneal refractive surgery. NPJ Digit Med. 2019;2:59. https://doi.org/10.1038/s41746-019-0135-8.
Achiron A, Gur Z, Aviv U, Hilely A, Mimouni M, Karmona L, et al. Predicting Refractive Surgery Outcome: Machine Learning Approach With Big Data. J Refract Surg (Thorofare, NJ : 1995). 2017;33(6):592–7. https://doi.org/10.3928/1081597x-20170616-03.
Cui T, Wang Y, Ji S, Li Y, Hao W, Zou H, et al. Applying Machine Learning Techniques in Nomogram Prediction and Analysis for SMILE Treatment. Am J Ophthalmol. 2020;210:71–7. https://doi.org/10.1016/j.ajo.2019.10.015.
Yoo TK, Ryu IH, Choi H, Kim JK, Lee IS, Kim JS, et al. Explainable Machine Learning Approach as a Tool to Understand Factors Used to Select the Refractive Surgery Technique on the Expert Level. Transl Vis Scie Technol. 2020;9(2):8. https://doi.org/10.1167/tvst.9.2.8.
Albahli S, Ahmad Hassan Yar GN. AI-driven deep convolutional neural networks for chest X-ray pathology identification. J X-Ray Sci Technol. 2022;30(2):365–76. https://doi.org/10.3233/xst-211082.
Wang Y, Chen Y, Liu R. Aircraft Image Recognition Network Based on Hybrid Attention Mechanism. Comput Intell Neurosci. 2022;2022:4189500. https://doi.org/10.1155/2022/4189500.
Bredesen-Aa BA, Rehmsmeier M. Gnocis: An integrated system for interactive and reproducible analysis and modelling of cis-regulatory elements in Python 3. PLoS ONE. 2022;17(9):e0274338. https://doi.org/10.1371/journal.pone.0274338.
Reinstein DZ, Archer TJ, Randleman JB. Mathematical model to compare the relative tensile strength of the cornea after PRK, LASIK, and small incision lenticule extraction. J Refract Surg. 2013;29(7):454–60. https://doi.org/10.3928/1081597X-20130617-03.
Xin Y, Lopes BT, Wang J, Wu J, Zhu M, Jiang M, et al. Biomechanical Effects of tPRK, FS-LASIK, and SMILE on the Cornea. Front Bioeng Biotechnol. 2022;10. https://doi.org/10.3389/fbioe.2022.834270.
Giri P, Azar DT. Risk profiles of ectasia after keratorefractive surgery. Curr Opin Ophthalmol. 2017;28:337–42. https://doi.org/10.1097/ICU.0000000000000383.
Chow SSW, Chow LLW, Lee C, Chan TCY. Astigmatism Correction Using SMILE. Asia-Pac J Ophthalmol (Philadelphia, Pa). 2019;8:391–6. https://doi.org/10.1097/01.APO.0000580140.74826.f5.
Ambrósio R, Wilson S. LASIK vs LASEK vs PRK: advantages and indications. Semin Ophthalmol. 2003;18(1):2–10. https://doi.org/10.1076/soph.18.1.2.14074.
Wu D, Wang Y, Zhang L, Wei S, Tang X. Corneal biomechanical effects: small-incision lenticule extraction versus femtosecond laser-assisted laser in situ keratomileusis. J Cataract refract Surg. 2014;40(6):954–62. https://doi.org/10.1016/j.jcrs.2013.07.056.
Amouroux C, Vincent M, Blanchet P, Puechberty J, Schneider A, Chaze AM, et al. Duplication 8q12: confirmation of a novel recognizable phenotype with duane retraction syndrome and developmental delay. Eur J Hum Genet EJHG. 2012;20(5):580–3. https://doi.org/10.1038/ejhg.2011.243.
Kahuam-LĂłpez N, Navas A, Castillo-Salgado C, Graue-Hernandez EO, Jimenez-Corona A, Ibarra A. Laser-assisted in-situ keratomileusis (LASIK) with a mechanical microkeratome compared to LASIK with a femtosecond laser for LASIK in adults with myopia or myopic astigmatism. Cochrane Database Syst Rev. 2020;4:CD012946. https://doi.org/10.1002/14651858.cd012946.pub2.
Alexander LJ. PRK: The Past, Present, and Future of Surface Ablation, Lucio Buratto, Stephen Slade, eds. LWW; 2013. https://doi.org/10.1111/j.1444-0938.2012.00792.x.
Omar D, Duarte C. The application of parameters for comprehensive smile esthetics by digital smile design programs: A review of literature. Saudi Dent J. 2018;30(1):7–12. https://doi.org/10.1016/j.sdentj.2017.09.001.
Sakr S, Elshawi R, Ahmed A, Qureshi WT, Brawner C, Keteyian S, et al. Using machine learning on cardiorespiratory fitness data for predicting hypertension: The Henry Ford ExercIse Testing (FIT) Project. PLoS ONE. 2018;13(4):e0195344. https://doi.org/10.1371/journal.pone.0195344.
Breiman L. Random forests. Mach Learn. 2001;45:5–32. https://doi.org/10.1023/A:1010933404324.
Freund Y, Schapire RE. A decision-theoretic generalization of on-line learning and an application to boosting. J Comput Syst Sci. 1997;55(1):119–39. https://doi.org/10.1006/jcss.1997.1504.
Chen T, Guestrin C. Xgboost: A scalable tree boosting system. In: Proceedings of the 22nd acm sigkdd international conference on knowledge discovery and data mining. 2016. p. 785–94. https://doi.org/10.1145/2939672.2939785.
Rumelhart DE, Hinton GE, Williams RJ. Learning representations by back-propagating errors. Nature. 1986;323(6088):533–6. https://doi.org/10.5555/65669.104451.
Hinton GE, Osindero S, Teh YW. A fast learning algorithm for deep belief nets. Neural Comput. 2006;18(7):1527–54. https://doi.org/10.1162/neco.2006.18.7.1527.
Perotte A, Pivovarov R, Natarajan K, Weiskopf N, Wood F, Elhadad N. Diagnosis code assignment: models and evaluation metrics. J Am Med Inform Assoc. 2014;21(2):231–7. https://doi.org/10.1136/amiajnl-2013-002159.
Han H, Wang WY, Mao BH. Borderline-SMOTE: a new over-sampling method in imbalanced data sets learning. 2005;878–87. https://doi.org/10.1007/11538059_91.
Acknowledgements
Not applicable.
Funding
This research is funded by the "Beijing Union Medical College Hospital's Sedimentary Research Fund Integration Entrusted Project" (ZC201904168) from the Myopia Diagnosis and Treatment Research Center of Peking Union Medical College Hospital. Funding agencies provided some support for the collection of study data and had no role in study design, conduct, analysis and interpretation of data, and writing of the manuscript.
Author information
Authors and Affiliations
Contributions
Jiajing Li, Yuanyuan Dai, Zhicheng Mu, Zhonghai Wang, Juan Meng, Tao Meng, and Jimin Wang conceived and designed the study. Jiajing Li, Yuanyuan Dai, and Zhicheng Mu undertook the analysis of the data. Jiajing Li and Yuanyuan Dai drafted the article. All authors provided support for the analysis and interpretation of results, critically revised the article, and approved the final article.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
This study was approved by the Ethics Review Committee of Peking Union Medical College Hospital, Chinese Academy of Medical Sciences. All methods were carried out in accordance with relevant guidelines and regulations in the Declaration of Helsinki. All subjects and/or their legal guardians signed an informed consent.
Consent for publication
Not applicable.
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Li, J., Dai, Y., Mu, Z. et al. Choice of refractive surgery types for myopia assisted by machine learning based on doctors’ surgical selection data. BMC Med Inform Decis Mak 24, 41 (2024). https://doi.org/10.1186/s12911-024-02451-0
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s12911-024-02451-0