Abstract
Loop-mediated amplification (LAMP) has been widely used to amplify and hence detect nucleic acid target sequences from various pathogens, viruses and genetic modifications. Two distinct types of primer are required for LAMP; hairpin-forming LAMP and displacement. High specificity arises from this use of multiple primers, but without optimal conditions for LAMP, sensitivity can be poor. We confirm here the importance of LAMP primer design, concentrations and ratios for efficient LAMP amplification. We further show that displacement primers are non-essential to the LAMP reaction at certain concentrations providing accelerating loop primers are present. We investigate various methods to quantify DNA extracts from GM maize certified reference materials to calculate the target copy numbers of template presented to the LAMP reaction, and show that LAMP can amplify transgenic promoter/terminator sequences in DNA extracted from various maize GM events using primers designed to target the 35S promoter (35Sp) or NOS terminator (NOSt) sequences, detection with both bioluminescence in real-time (BART) and fluorescent methods. With prior denaturation and HPLC grade LAMP primers single copy detection was achieved, showing that optimised LAMP conditions can be combined with BART for single copy targets, with simple and cost efficient light detection electronics over fluorescent alternatives.
Similar content being viewed by others
Introduction
Quantitative molecular diagnostics are required to assess the concentration of genetically modified material in food sources. Within the European Community, regulation 1830/2003 requires the appropriate labelling of food products where the percentage concentration of genetically modified material exceeds 0.9 percent. In California in 2012 the vote went against ‘Proposition 37’ which would have required mandatory labelling for all GMO contamination1. Low target number sensitivity is therefore needed, which in turn requires optimisation of the detection technique. Numerous techniques have been employed for GM detection2 with the majority centred on specific nucleic acid sequence determination. Novel techniques such as capillary electrophoresis with laser-induced fluorescence3 and biosensing with oligonucleotide conjugated gold nanoparticles4 can detect the cauliflower mosaic virus 35S promoter (CaMV 35Sp) at 0.1 percent GMO to wild type, but have not been widely adopted. Real time quantitative polymerase chain reaction (qPCR) has become the benchmark technique due to sensitivity and specificity, but there are challenges and costs to overcome for accurate GM quantitation5.
Isothermal amplification methods have also been used for GM detection6,7 with the potential benefit of lower cost instrumentation, since isothermal amplification of nucleic acid template operates at a single temperature without the requirement for thermocycling equipment. There are numerous described methods8,9,10 with redesigned or modified oligonucleotides, using either enzymatic strand displacement or RNA production to amplify the nucleic acid template. The various DNA based methods require strand invasion to generate accessible template before and during polymerisation to achieve exponential amplification.
Loop-mediated isothermal amplification (LAMP) is a method that uses a strand displacing DNA polymerase and hairpin-forming oligonucleotide primers11. LAMP is simple, rapid and target specific, with greater robustness to inhibitory substances than PCR6,12. Two distinct types of primer are required for LAMP; hairpin-forming LAMP primers that are integral to the amplification, and displacement primers which are required during amplification initiation to generate the initial dumbbell structure that creates the basic amplicon. These primers are designed to target at least six template annealing positions, resulting in a high degree of specificity (Fig. 1a). Further primers can be used to accelerate the LAMP reaction; these are Loop primers binding within the dumbbell loops13 and STEM primers14 which anneal to the region between the hairpin loops.
The complex LAMP amplification mechanism is initiated by the hairpin-forming LAMP primers (forward and backward inner primers; FIP and BIP) by strand invasion of the double stranded DNA template. DNA polymerisation is initiated from these primers and the newly synthesised strands are displaced by primers designated F3 and B3. The absolute requirement for these displacement primers is generally assumed, but remains unclear and is addressed in the present work. The displaced ‘dumbbell’ structure with hairpin loops at each end is the structure required for cycling and elongation stages using the FIP and BIP primers. Typically LAMP amplification is conducted at 60 to 65 degrees with the length of assay time dependent on the reaction kinetics and concentration of the template. Amplification will proceed without the need for target denaturation, but there is evidence that pre-denaturation increases assay sensitivity15, supported further by results in this paper. By denaturing the double stranded DNA, the potentially limiting step of strand invasion by LAMP primers into the ‘breathing’ DNA is removed and the sensitivity thereby increased.
Nucleic acid amplification using LAMP can be detected in a number of ways. The first method exploited the production of inorganic pyrophosphate (PPi), a by-product of amplification, using the turbidity of magnesium pyrophosphate16 or in real-time17. Various fluorescence methods have been employed with calcein18 and nucleic acid intercalating dyes such as SYBR green, ethidium bromide and PicoGreen for end point detection of LAMP amplification after completion of reactions. Also colorimetric determinations have been shown19. Real-time detection of fluorescence has been described with SYBR green20, probe based methods such as DARQ21 and QUASR22 and here we demonstrate the effective use of SYTO923,24,25. The bioluminescent assay in real time (BART)26 exploits the light emission produced by recombinant thermostable luciferase utilising the substrates luciferin and ATP. The ATP is produced from pyrophosphate in an ELIDA reaction (enzymatic luminometric inorganic pyrophosphate assay)27 whereby ATP-sulphurylase catalyses the reaction. The development of thermostable luciferase functional at 60 to 65 degrees makes BART possible [Gandelman et al.26].
BART detects nucleic acid amplification in a closed tube format, which reduces the risk of amplicon contamination. The light produced from each sample partition is recorded continuously and analysed by a simple CCD camera or photodiode detection system linked to a computer. A heat block is required at a single temperature. The BART profile for a positive sample is characterised by a peak of light at a particular time point at which the concentration of pyrophosphate inhibits the luciferase through the depletion of the substrate adenosine 5′phosphosulphate (APS). The time from the start of the assay to time-to-peak or Tmax is inversely proportional to the concentration of the original sample DNA template. LAMP amplification has been used successfully with BART due to the high concentrations of inorganic pyrophosphate produced enabling low nucleic acid copy number detection.
The sensitivity of LAMP based GM assays has been reported in several papers, including the detection of 10 copies of a marker in transgenic soya28, 10 copies of maize event markers29 and 10 copies for the detection of three GM rice events30. The possible sensitivity of LAMP to amplify single copies has seen some developments towards absolute quantification using digital LAMP31,32,33 using microfluidic devices.
However, poor sensitivity results for LAMP have also been reported recently7 with the detection of only 2 of 5 replicates for a 5 percent mass fraction of the transgene of maize event MON810 in wild type maize, corresponding to 770 copies per reaction based on the assumption of one transgene copy per genome equivalent. This work was in contrast to earlier work on the same target which reported a sensitivity of 50 copies (Kiddle et al.), and led to a discussion and response in the literature34,35. The poor sensitivity reported highlights the requirement for further analysis to establish the reasons underlying apparent differences in LAMP sensitivity at low target concentrations.
Here we analyse in detail the differences in the literature, and in resolving these clearly demonstrate how appropriately optimised LAMP reactions can readily amplify and hence detect the presence of a single transgene copy present in a reaction of DNA extracted from various maize GM events using primers designed against both 35S promoter (35Sp) and NOS terminator (NOSt) sequences. We show that the use of HPLC purified primers and the denaturation of genomic template is important in the reliable amplification of very low copy numbers. Furthermore we show that LAMP amplification can be detected with both bioluminescent and fluorescent real-time strategies with comparable results at single copy sensitivity.
Results
Optimisation of LAMP for high sensitivity
We investigated the reported absence of DNA sequence in the 35S promoter homologous to one of the Kiddle et al.6 and Lee et al.28 primers by aligning published sequences with our newly obtained sequence results for Mon810 and Bt11. Sequences for the 35S promoter in the plasmid vector pRR21 (GenBank EU760495.1) and in Mon810 (GenBank JX139718.1 and KJ608135) were compared to our sequence results for Mon810 (Fig. 1). The position of the LAMP primers used by Kiddle et al. are highlighted and labeled according to type, the primers designed by Zahradnik et al. are indicated by dashed lines. Sequence alignment for the displacement primer B3 shows that JX139718.1 is a partial sequence and the required sequence is present. The alignment for Bt11 (Fig. S1) also clearly demonstrates the presence of all sequences for primer binding.
The conclusion of Zahradnik et al.7 that the absence of a displacement primer sequence would necessarily have caused LAMP to fail was further investigated using both the primer sets used by Zahradnik (Z primers) and those used by Kiddle (K primers) to amplify 35S sequences of genomic DNA extracted from ground seeds from variety Mon810. The DNA quantity was calculated to contain 208 copies of the 35S target, assuming that the material was hemizygous and 1 ng of transgenic DNA is equivalent to 160 target copies (see Methods). BART reporting of amplification was used. Light peaks indicating amplification occurred within 10–20 minutes, with a delay of a few minutes when the F3 displacement primer was omitted (Fig. 2). The variation in amplification timing between replicates also increased when one displacement primer was omitted, and the peak of amplification signal was lower (Fig. 2d). Nevertheless, for all primer combinations, the amplification frequency was 100 percent whether or not primer F3 was present at a calculated presence of 208 copies of target per reaction. We conclude that LAMP amplification can proceed effectively on a genomic template in the absence of the F3 displacement primer using either 35S promoter LAMP primer set, but that the rate and reproducibility of the LAMP reaction were compromised by the removal of a displacement primer, suggesting this might affect sensitivity at extremely low copy number. Nevertheless, omission of one displacement primer does not prevent effective LAMP amplification on genomic samples at down to 200 copies per reaction.
To ascertain whether the reporter system used for LAMP amplification alters the observed sensitivity in marginal conditions when primers are omitted, whether both displacement primers can be omitted, and whether template type affects these results, the primer combination assay was conducted using SYTO 9 for fluorescent reporting of amplification. The results previously obtained with BART were replicated (Fig. 3) in that either displacement primer could be omitted using either genomic or linearised plasmid template without loss of LAMP amplification. Moreover, we found that LAMP amplification could proceed without any displacement primers albeit with reduced amplification efficiency, providing loop primers are present. For linearised plasmid this slowed down average Tmax from 12.52 to 15.49 and 11.84 to 15.17 minutes for Z-primers and K-primers respectively. Larger differences were observed with genomic template. Melt curve analysis showed LAMP amplicon formation with a melt temperature of 85 degrees for all positive results and no values for the no template control (NTC) and LAMP primer only reactions. These data confirm that displacement primers are not required for LAMP amplification at the copy numbers investigated, provided accelerating loop primers are present, and that results are independent of detection method.
Having investigated the primer requirements for 35S promoter detection, we analysed the effect of LAMP primer ratios on assay kinetics and sensitivity. Zahradnik et al.7 used the ratio of primers LAMP: Loop: displacement of 4:1:2 at concentrations of 0.8, 0.2 and 0.4 micromolar respectively. In contrast, Kiddle et al. used the ratio of 4:2:1 of LAMP: Loop: displacement at concentrations of 1.6, 0.8 and 0.4 micromolar. Since we did not observe amplification differences when halving these concentrations, we reduced the concentration of the K primers to 0.8:0.4:0.2 to allow direct comparison with Zahradnik et al. at the same LAMP primer concentration. Using the Zahradnik ratios with the Z LAMP 35S primer sets at two concentrations of native DNA from maize event Mon810, the assay was slow for both concentrations of template (Fig. 4). LAMP-BART reactions were confirmed by endpoint agarose gel analysis showing amplification was successful for all reactions containing 208 copies per reaction, and for 60 percent of reactions containing 21 copies (Fig. 4). We conclude that LAMP-BART has comparable sensitivity to the end-point method. However the K-primers showed no amplification of template at either concentration using the Zahradnik ratios. This failure replicates the observation of Zahradnik et al.7 that they could not achieve LAMP amplification with K LAMP primers for the detection of maize event Mon810 (prepared from commercial seed).
However, altering the ratio of LAMP primers to 4:2:1 of LAMP: Loop: displacement as used by Kiddle et al. at the same concentrations of 8, 4 and 2 micromolar dramatically improved all results. Faster reaction times were seen with the Z primers (Fig. 4e,) than previously observed (Fig. 4) and amplification with K primers was also seen, indicating that this primer ratio is more favourable. The sensitivity of the LAMP-BART and the LAMP-endpoint assays was improved with a 100 percent amplification frequency for both 208 and 21 copies with the Z-primers and 100 percent at the higher concentration with K-primers and c. 65 percent at the lower concentration.
However, these results explain the data previously reported (Zahradnik et al.7), and demonstrate the impact of and requirement for optimised LAMP primer concentrations and ratios. These results also indicate that the Z-primer set appears to have superior performance giving faster and more reliable amplification at lower target concentrations, but the optimised primer ratio of Kiddle et al. works better with both primer sets.
Single Copy Detection
We next sought to make use of optimised assays to determine whether single target detection could reliably be achieved. The calculation of the dilution required to achieve an average of one target DNA copy per reaction partition necessitates the accurate determination of DNA concentration from genomic DNA samples prepared from standard Certified Reference Material (CRM) maize meal. This must then be converted to DNA target copies using a calculation based on the zygosity of the CRM which is normally of hybrid origin, contribution of different tissues to the seed and any duplication of sequences within the transgenes present36,37. Our previous results suggested that spectrophotometric measurement (Nanodrop) can over-estimate the concentration of maize genomic DNA purified using standard kits when compared to agarose gel quantification (Kiddle et al.34). To extend this analysis, we compared Qubit fluorimetry with NanoDrop spectrophotometry and agarose gel band intensity methods for quantifying DNA purified from maize events Mon810, Bt11 and NK603 (Fig. 5), and found wide variation between spectrophotometric and other methods dependent on sample.
We further investigated quantification using a DNA extract from maize event Bt11 to compare DNA measurement by fluorimetry with Agilent TapeStation using a genomic tape, and direct copy number determinations by qPCR, digital PCR (dPCR) using a TaqMan probe in a Quant Studio 3D assay. Quantitative PCR quantification was calibrated against a defined dilution of linearised plasmid carrying the 35S promoter in the range 5 to 500000 copies per 5 microlitres (Fig. 6). The dilutions of the Bt11 genomic sample were quantified against these curves. For the native genomic DNA, the background fluorescence of the undiluted and the 1:2 diluted samples were high; the calculated DNA concentration of the undiluted Bt11 sample taken from a 1: 5 dilution was 12.2 nanograms per microlitre. Replicate qPCR results are shown in Fig. S3.
Results are presented in Fig. 6 for samples of DNA extracted from 0.1 percent Bt11 sample and 5.0 percent NK603 CRM, and summarised in Table 1 compared to data derived from known dilutions of plasmid pART7 carrying the same target sequence. We conclude that the NanoDrop overestimated the concentration of our sample when compared to other quantification techniques. There was however excellent agreement between DNA measurements by the Qubit fluorimeter and Agilent Tapestation. Copy numbers of 35S sequences for the Bt11 sample were converted to calculate DNA equivalents and values of 7.04 nanograms per microlitre for qPCR and 18.62 nanograms per microlitre for digital PCR were obtained. We note that the upper figure of 18.62 nanograms per microlitre for digital PCR may be subject to reduced reliability due to the low number of positive partitions on the QuantStudio 3D digital PCR chip, although the overestimate of DNA concentration was also apparent with the 5 percent NK603 extract. Both the qPCR and dPCR methods quantify based on copies of the 35S promoter sequence. The conversion of these values to nanograms of DNA are corrected for hemizygosity of the GM material, the contribution of tissues of different ploidy and parental origin to the sample, and the two copies of the 35S target sequence present in Bt11. The Qubit fluorimeter measurement was a convenient method to calculate single target copy number for our LAMP sensitivity investigations, based on the closest value to the average of the four techniques (Table 1).
Qubit fluorimeter quantifications were used to calculate the dilutions of 0.1 percent Bt11 maize DNA extract to give the equivalent of single copy or less of target sequence per reaction. Here we also took into account the effect on target copy number of denaturing the template before addition to the reactants, since an originally double stranded template yields two amplifiable molecules on denaturation, and these are then assumed to distribute independently. We also assumed that any duplicated sequences, such as the two 35S promoter sequences in Bt11, distribute independently.
To maximise amplification, and since we had observed that amplification of the K primers was less effective than Z primers, we sought to optimise further the K primer set. Changes were made to the length, GC content and melt temperature of the displacement primers and the FIP primer. Comparison of the optimised K+ primers showed improved performance to the K primers in sensitivity, reproducibility and reaction kinetics (Fig. 7a). We further observed that primer quality affects amplification performance and the use of HPLC purified primers gave further performance enhancement with reduced replicate variation (Fig. 7b) when compared to desalted primers. The concentration of K+-primers in LAMP-BART assays was compared using the concentration described by Kiddle et al. (Fig. 7g,h) and halved concentrations (Fig. 7c,d). The amplification frequency for these two 96 partition single copy assays was 44 percent and 47 percent with average Tmax values of 33.65 and 33.57 minutes respectively. We concluded that the reduced primer concentration does not impact on LAMP-BART sensitivity and assay kinetics.
To understand the effect of template denaturation on linear plasmid and genomic DNA templates, samples calculated to contain 4 double stranded copies per partition of maize Mon810 genomic DNA were amplified with K+ primers (Fig. 7e,f for native and i,j for denatured). This resulted in an increase in positive partitions of 14.6 percent to 37.5 percent in response to DNA denaturation. We note that part of this improvement may be due to increasing the number of independently distributing molecules, although the improvement to amplification frequency was not observed with linearised plasmid template (Fig. 7k), as 100 percent amplification was seen at 10 copies per partition and above, and 62.5 percent and 50 percent for native and denatured respectively at single copy level; the difference between which is likely not significant. The genomic DNA denaturation may increase the amount of cryptic priming sites and therefore the amount of non-specific displacement priming. Moreover the denatured linear plasmid DNA is more likely to re-anneal than genomic DNA.
Having established optimised conditions, the sensitivity of LAMP-BART for near-single copy detection of DNA from maize event Bt11 was assessed using 35S promoter and NOS terminator primers for the same GM event.
Three replicate sets of assays were carried out with 64 test partitions each with a calculated mean 0.8 copies of denatured target sequence of 0.1 percent Bt11, plus 8 NTC partitions. Targeting the 35S promoter with K+ primers provided an overall mean value of 13.3 percent of partitions showing amplification (SD 3.3percent; Supplementary Fig. S4; representative example showing 7 positive partitions from 64 [10.9 percent] in Fig. 8). Using Z primers also targeted to the 35S promoter a mean of 4.7 percent, (2.3 percent SD; example in Fig. 8 shows 6.3 percent positive samples). Targeting the NOSt sequence, which is part of the same GM event in Bt11, showed a frequency of mean 30.5 percent, (3.3 percent SD; example shown Fig. 8 with 28.1 percent). We noted that the NOSt targeting assay produced a faster average Tmax and lower variation between replicates than the two 35Sp assays. We conclude that LAMP-BART assays can detect single copies of denatured genomic DNA target.
The same maize DNA extract dilution reaction was amplified, but with the detection provided by SYTO9 dye on a qPCR platform.
Replicate fluorescent LAMP assays targeting the 35S promoter with Z primers showed a frequency mean of 11.0 percent, 6.6 percent SD (Fig. 9; example assay set shown with 6.3 percent, Supplementary Fig. S5 shows 15.6 percent), broadly similar to the equivalent LAMP BART assay shown in Fig. 8(b). Timing of amplification was variable as previously observed using LAMP-BART on these low copy number assays, indicating this is a feature of LAMP, rather than the detection method used. Similar results were observed with the other two assays; the amplification frequency for the K+ primers for this assay had a mean of 12.5 percent, 5.7 percent SD (Fig. 9b, 18.8 percent in this set), and using NOSt primers had a mean of 28.6 percent; 7.2 percent SD (Fig. 9c; 20.3 percent, Supplementary Fig. S6; 32.8 percent and 32.8 percent), again producing a higher amplification frequency from the 0.1 percent Bt11 maize target than the 35S primers.
We can conclude that single copy detection can be achieved with LAMP using optimal conditions and that BART and fluorescent reporting of the amplification of single copies of denatured genomic DNA are similar in sensitivity.
Discussion
Whilst controversy exists on the sensitivity of LAMP to amplify low copy number targets in the literature (Kiddle et al. and Zahradnik et al.)6,7, here we demonstrate clearly that LAMP amplification of genomic DNA targets is effective, and show that the design, ratios and concentrations of LAMP primers are key factors in determining LAMP sensitivity. Specifically Zahradnik et al.35 state that the sensitivity of LAMP targeting the cauliflower mosaic virus (CaMV) 35S promoter [Kiddle et al.; Zahradnik et al.]34,35 previously reported by Kiddle et al.6 was unattainable. To seek to resolve these discrepancies, we analysed all aspects of the reaction.
Firstly we used the Promega Wizard genomic DNA purification kit for our DNA extractions. In contrast Zahradnik et al. extracted maize DNA using an optimized cetyltrimethylammonium bromide (CTAB) protocol. Kiddle et al. showed improved sensitivity and reproducibility with the Promega Wizard kit compared to a CTAB protocol for maize extraction for LAMP amplification and detection with BART6.
The two papers make use of different primer sets (Figs S2 and 1b) and different primer ratios. However, in Zahradnik et al., a ‘theoretical and experimental’ problem was attributed to the 35S promoter LAMP assay of Kiddle et al.6 and Lee et al.28 due to the reported absence of sequence in the 35S promoter homologous to one of Kiddle’s primers, based on sequence from Spalinskas et al.38 (GenBank accession number JX139718.1). If correct, this would remove the binding site for the B3 displacement primer. Other published sequences for the 35S promoter in the plasmid vector pRR21 (GenBank EU760495.1) and two published sequences for Mon810 (GenBank JX139718.1 and KJ608135) were therefore compared to our newly obtained sequence results for Mon810, clearly demonstrating the presence of all primer sequences in both the standard 35S promoter and Mon810 T-DNA (Fig. 1). We concluded that absence of cognate sequence does not explain the differences between primer sets reported by Zahradnik et al.7. Additional newly obtained sequence results for Bt11 are shown in Fig. S1.
The combination of primers required for LAMP, including the LAMP primers themselves, displacement and loop primers makes for complex primer design, and two designed primer sets for the CaMV 35S promoter sequence may differ in efficiency and propensity for non-specific primer interaction. Accurate sequence data is of course required to confirm alignment with primers as a partial sequence can lead to inaccurate conclusions and attention should be brought to the presence of single nucleotide polymorphisms in the 35S promoter sequence39,40, when considering LAMP primer design. False negative results can result from poorly chosen primers and sub-optimal assay conditions leading to negative reports about the efficacy of LAMP for nucleic acid detection at low copy number. This was shown with the two sets of 35Sp LAMP primers with suboptimal primer ratios. We show that primer ratios, primer concentrations and reagent composition and concentrations markedly improved the amplification frequency with endpoint detection of the LAMP assays when using the reaction conditions specified in Kiddle et al.6. The concentrations of FIP and BIP primers were identical for the two ratios, however twice the concentration of displacement primers and half the concentration of Loop primers was used in the Zahradnik et al.7 ratio. There may be a dual impact of this on amplification kinetics; a sub-optimal concentration of Loop primers may reduce the rate of priming from Loops with concomitant reduction of pyrophosphate/DNA production, and the excess of displacement primers may occlude the potential of LAMP primers to invade and initiate amplification.
We further showed that LAMP amplification can proceed without either or both displacement primers, although the resulting amplification is sub-optimal leading to slower reaction times. It is unclear whether assay sensitivity at very low copy numbers would be compromised and this would require further investigation. Since LAMP amplification can proceed without displacement primers, this might suggest that the initiation of amplification can use an alternative mechanism to displace the hairpin-forming LAMP primers perhaps linked to the energetics of loop formation. This observation could be useful in the design and optimisation of LAMP primers in screening for non-specific primer interactions from the hairpin-forming primers independently of displacement primers.
A number of routinely used quantification techniques were compared to determine DNA concentration and target copy number either directly or by calculation. Measurement derived from the NanoDrop spectrophotometer were higher than the other methods for these samples, presumably due to residual RNA contaminants and other UV absorbing compounds interfering with measurement accuracy. The other quantification techniques provided results within a two fold range, and in particular Very similar results were obtained for fluorescence and Agilent TapeStation determinations of DNA concentration. The highest value in the range was derived from copy number determination by digital PCR with 35S promoter TaqMan primers. As this result is from absolute quantification this might be considered to represent a benchmark value (assuming 100 percent amplification efficiency). However the accuracy of this technique for quantification may have been compromised by the low number of positive results (36 and 41) from over 17000 used partitions. We took the value from the fluorimeter as the nearest to the average of the four techniques (digital PCR, Agilent TapeStation, fluorimetry and qPCR) which was the value from the fluorimeter. A similar approach was used by Holden et al. (2010) with PicoGreen binding.
Denaturing genomic DNA before LAMP amplification enhanced the detection of low copy numbers of the transgene 35S promoter. Without denaturation, LAMP amplification is initiated by primers invading the double stranded DNA and relies on the DNA ‘breathing’ to allow primers access. Denatured DNA has the benefit of being single stranded allowing primers to bind more readily. The increase in amplification frequency suggests that the initiation of LAMP amplification becomes less of a limiting step. The size and complexity of genomic DNA may be factors in the improvement from denaturation seen with genomic DNA when compared to linear plasmid DNA. However, we also note that prior denaturation presumably doubles the number of independently distributing molecules since both DNA strands are capable of initiating amplification, and our calculations take this into consideration. We propose that the normal practice of considering the number of double stranded DNA molecules needs to be revised when considering pre-denatured samples then analysed by digital or single copy techniques.
In the calculation of copy number for the CRM Bt11 and NK603 and for DNA prepared from our own seed stock of Mon810, we used the simulations of GM content from Trifa and Zhang36. Their calculations showed that the hybrid seed used for CRM material will carry a hemizygous GM locus derived from the transgenic male parent (as in the case of both these maize events). However, due to the seed being composed of diploid embryo and triploid endosperm (comprising two maternal and one paternal genome) will have a GM content of 160.4 copies per nanogram using the commonly accepted haploid maize genome size of 2.6 picograms. Homozygous transgenic maize contains 385 copies per nanogram of DNA. Our calculations of copy number reflect this reduction. There is further uncertainty with the CRM materials, which are composed of mixtures of ground seeds from GM and non-GM sources, since environmental factors during growth such as moisture content and temperature can affect DNA contents of the different ground material41,42. The certified value for the CRM based on grams per kilogram of GMO material of our sample European Reference Material supplied by the Joint Research Centre was reported to be 9.8 grams per kilograms with an Uncertainty of 0.9 grams per kilogram. As an example, an uncertainty of 2.1 grams per kilogram was assigned to a 5 percent Bt11 CRM with a certified value of 48.9 grams per kilogram at a 95 percent confidence level. Trapmann43 presents analysis to show that when calculating DNA content based on copy number determination, the relative expanded uncertainty associated with the measurement increased two-fold.
Both BART and fluorescence methods provided similar amplification frequencies in single copy detection with all three LAMP primer sets and both target sequences of the Bt11 sample. The highest amplification frequencies were for the K+ 35S primers and NOS terminator assays with both detection methods. Importantly for the LAMP detection strategies, similar amplification frequencies were observed with both LAMP-BART and fluorescent LAMP, which tracked the amplification in real time enabling a shorter assay time in comparison to visual end-point detection, also without the risk of contamination from opening tubes post-amplification.
In our assays with a calculated mean copy number of 0.8 per reaction, and assuming that the every DNA target molecule can initiate and is amplified with 100 percent efficiency, the calculated amplification frequency of multiple replicate assays should be 55 percent44,45. This frequency was not achieved using any primer set, and actual results varied between 6–30 percent for different primer sets; equivalent to an average copy number per partition of 0.1–0.5 (based on projections in Fig. 7(l)). There is variation in amplification frequency between the two assays targeting the 35S promoter as well as with the assay for the NOS terminator sequence in the same template, which indicates the importance of LAMP primer design to optimise the frequency of amplification. However, our assumption of the independent distribution of the two 35S promoter sequences present in the Bt11 transgene which are in fact contained on a single DNA fragment of 3–4 kb is likely to be true only in a subset of cases where the DNA is fragmented between these sites. Since our genomic DNA size is significantly larger than this (Fig. 6d), this is probably not correct, which would lead to an overestimate of effective copy number by a factor of up to 2. Together with measurement uncertainties explored in the previous paragraph, it is plausible that the best primer sets (K+ for 35S and the NOS terminator set) are achieving close to 100 percent target amplification.
Here we have demonstrated efficient and effective single copy detection of nucleic acid target sequences within a complex genome using optimised conditions and efficient primers. This work offers the potential for the development of digital LAMP for quantification without the requirement for standard curves to determine nucleic acid concentration.
Methods
Plant materials
Certified reference materials (CRM) for maize events Bt11 and NK603 from the Institute for Reference Materials (Geel, Belgium) purchased from Fluka GmbH (Buchs, Switzerland) were supplied with a defined mass fraction of 0.1 percent (Bt11) and 5.0 percent (NK603) w/w with wild type maize (0.1 percent Bt11: certified value 0.99 grams per kilogram with uncertainty of 0.13 grams per kilograms, 5 percent NK603: certified value 49.1 with uncertainty of 1.3). The maize event Bt11 developed by Syngenta Seeds S.A.S (Nerac, France) contains the transgenes cry1Ab (resistance to the European corn borer from Bacillus thuringiensis subspecies kurstaki) and pat (phosphinothricin N-acetyltransferase encoding gene from Streptomyces viridochromogenes, conferring tolerance to glufosinate herbicide). The expression of both transgenes is under the 35S promoter from the cauliflower mosaic virus (35Sp) and the nopaline synthase terminator from Agrobacterium tumefaciens (NOSt). Hence Bt11 contains two copies of both 35Sp and NOSt46. The maize event NK603, developed by Monsanto (St. Louis, United States) contains two copies of the transgene cp4epsps (5-enolpiruvilshikimate- 3-phosphate synthase from Agrobacterium sp. strain CP4 conferring glyphosate tolerance). The expression of one copy is promoted by 35Sp and both are terminated by NOSt. Seed stocks of commercial Mon810 were also used for DNA extraction after cleaning with molecular grade water to remove the anti-fungal coating and grinding to a fine powder with a mortar and pestle with liquid nitrogen. The maize event Mon810 produced by Monsanto contains the cry1Ab gene under the regulation of the 35S promoter and NOS terminator, although subsequent studies showed that the NOSt sequence has been lost from the Mon810 event47,48.
Plant genomic DNA extraction
The Promega Wizard genomic DNA purification kit (Madison, United States) was used for the extraction of 40 mg of maize seed powder from the events Bt11, NK603 and Mon810 according to the manufacturer’s instructions for plant tissue. Extracts were rehydrated with 50 microlitres of the Tris:EDTA buffer from the kit and stored at 4 degrees C overnight.
Plasmid DNA standard preparation
The pART7 plasmid49 containing the 35S promoter sequence was linearised by cutting with Eco RI. Initial quantification using the NanoDrop 1000 spectrophotometer and the Agilent 2100 Bioanalyzer preceded dilution with molecular grade water, salmon sperm DNA and gel loading buffer to give a final concentration of 4 × 10(6) copies per microlitre. Frozen 100 microlitre homogenised replicates were dried down in a centrifugal evaporator without heating and were re-suspended with 400 microlitre of molecular grade water to 10(6) copies per microlitre before use. Sequence data indicated a number of mismatches in this linearised plasmid to standard 35S promoter data and as a consequence the B3 displacement primer denoted K+ was redesigned and designated with (P).
Purity and quantification of template DNA
The purity of the genomic DNA extracts from the maize events was analysed on 0.8 percent agarose gels prepared in TAE buffer, containing either SafeView (NBS Biologicals Ltd, UK) or GelRed (Biotium Inc., US) intercalating nucleic acid stains for visualisation using UV fluorescence in a Syngene U:Genius Gel Documentation system. The extracts were also assessed for purity using the NanoDrop 1000 spectrophotometer (Fisher Scientific, UK) using the wavelength ratios 260:280 nm and 260:230 nm. Values between 1.7 and 1.9 for the ratio 260:280 were deemed acceptable; as were those between 2.0 and 2.2 for the ratio 260:230.
Initial quantification of the template DNA was by NanoDrop® spectrophotometer to the manufacturer’s guidelines for double stranded DNA. Concordant quantification results were achieved between Qubit (Life Technologies, UK) fluorometric and agarose gel electrophoretic quantification. The Qubit dsDNA BR assay kit was used in accordance with the instructions with the Qubit 2.0 fluorometer. Agarose gel quantification used the method from Eurogentec using SmartLadder 10 kb and 0.8 percent agarose gels prepared in TAE buffer. The intensity of the gel bands of the ladder and samples were analysed using ImageJ (National Institutes of Health, USA) software version 1.51 u.
Template denaturation
Where indicated, genomic and linear plasmid DNA templates were heat denatured at 95 degrees for five minutes before rapid cooling on ice for five minutes.
Copy number calculations
The initial quantification values from NanoDrop, Qubit, agarose gel and Agilent Tapestation quantification methods were converted from nanogram per microlitre to copies per microlitre using the following formula in Fig. 10:
The maize genome was assumed to be 2.4 × 10(9) base pairs in length.
The online calculator was used at http://cels.uri.edu/gsc/cndna.html.
The CRM materials for maize events Bt11 and NK603, and the seed stock of Mon810 are hemizygous. Coupled with this the endosperm is triploid, one third of which is paternal and the embryo is diploid. Trifa and Zhang36 simulated the GM content for homozygous GM locus (385 copies per nanogram) and hemizygous with GM locus from male transgenic parent (160 copies per nanogram). In our calculations the transgenic copy numbers are adjusted by 160/385). Furthermore Bt11 has two copies of both the 35S promoter and the NOS terminator, doubling the available target sequences and the calculations of copy number reflect this. The calculations of copy number using the CRM material assume that the DNA content from both GM and non-GM samples combined will be the same. Environmental factors such as temperature and water content are also assumed to be the same.
Primer design and synthesis
All oligonucleotide primers for LAMP and PCR DNA amplification were synthesized and supplied by Sigma (Poole, UK) to a standard level of purity (except where stated as HPLC purified). All primers were hydrated with molecular grade water to 100 micromolar and stored at −20 degrees. Primers used for qPCR and TaqMan digital PCR are displayed in Table 2 and LAMP primers are shown in Table 3.
LAMP amplifications
The optimised chemistry for LAMP amplification was as described in Kiddle et al.6. Salmon sperm carrier DNA at 100 nanograms per partition was added to all LAMP reactions. The concentration of the primers for LAMP was 0.8 micromolar for each LAMP primer, 0.4 micromolar each Loop primer and 0.2 micromolar each displacement primer with a ratio of 4:2:1 respectively. Published concentrations of primers by Zahradnik et al.7 for the detection of the CaMV 35S promoter in GM crops, were 0.8 micromolar for each LAMP primer, 0.2 micromolar each Loop primer and 0.4 micromolar for each displacement primer with a ratio of 4:1:2 respectively. These differing concentrations and ratios were compared for LAMP assay target sensitivity. The LAMP assays were conducted on a programmable TRobot thermal cycler (Biometra, Göttingen, Germany) at a constant 60 degrees C for 100 minutes.
Real-time and end-point detection
The LAMP-BART chemistry was previously described by Kiddle et al.6 and Gandelman et al.26. The final reaction volume for LAMP-BART assays was 20 microlitres inclusive of 5 microlitres of DNA template or negative template control. Assays were loaded to white 96 well microtitre plates, layered with mineral oil and sealed with a clear adhesive cover. The bioluminescent signal was recorded in a ‘LUCY’ developed by Lumora Ltd (Ely, UK), and analysed using React IVD software developed by Synoptics (Cambridge, UK) at 60 degrees C for 100 minutes. The BART detection system allowed the LAMP amplification of target DNA to be visualised in real time (Fig. 11).
End-point visualisation of LAMP was by resolution by electrophoresis on 2 percent agarose gels, prepared with TAE buffer, with GelRed intercalating nucleic acid stain and a UV transilluminator.
Quantitative PCR amplifications
Samples were amplified by real-time quantitative polymerase chain reaction using a Qiagen (Hilden, Germany) Rotor-Gene thermal cycler and SYBR Green JumpStart Taq ReadyMix (Sigma; Poole, UK) according to the manufacturer’s recommendations. The reaction volume of 20 microlitres consisted of 5 microlitres of extracted DNA template or non-template control with molecular grade water, 10 microlitres of JumpStart, 5 picomoles of each respective primer (Sigma HPLC purified targeting the CaMV 35S promoter and the NOS terminator sequences) made up to volume with molecular grade water. The parameters were set at 94 degrees C for 2 minutes for activation of the hot-start Taq polymerase, followed by 50 cycles of 94C degrees (30 seconds), 50 degrees C (30 seconds) and 72 degrees C (30 seconds). Following amplification, the melting temperature of the amplicons was recorded between 60 and 92 degrees C. The Rotor-Gene 6000 software v1.7 and Microsoft Excel were used to analyse the data.
Fluorescent LAMP amplifications
SYTO dyes have been successfully used in real-time PCR50 and real-time LAMP51 as an alternative to the more commonly used SYBR green dyes. Samples of a 4.9Kb linearised plasmid with the CaMV 35S promoter sequence were used to optimise a real time quantitative LAMP reaction (data not shown). The reaction volume of 20 microlitres contained 1x Isothermal Buffer (NEB), 300 micromolar each dNTP, 0.8 molar betaine, 0.5 micromolar SYTO 9 Green, 0.32 Units per microlitre Bst polymerase v2.0 WarmStart (NEB), 0.8 micromolar each LAMP primer, 0.4 micromolar each Loop primer and 0.2 micromolar each displacement primer, made up to the final volume with molecular grade water. The real-time fluorescent LAMP reaction was performed on the Corbett Rotor-Gene thermal cycler at 60 degrees C for 60 seconds for a total of 100 cycles acquiring fluorescence data during each cycle. The DNA amplification was followed by amplicon melt temperature recording between 60 and 92 degrees C. The Rotor-Gene 6000 software v1.7 and Microsoft Excel were used to analyse the data.
Agilent Tapestation quantification
Maize genomic DNA from the event Bt11 were quantified on genomic tapes in the Agilent Tapestation (Agilent; California, USA) following the protocol for genomic tapes. Briefly 1 microlitre of either genomic DNA or ladder was combined with 10 microlitres of genomic DNA sample buffer, vortexed and loaded into the instrument. The genomic tapes were robotically loaded and the resulting bands sized between 200 and greater than 60000 base pairs.
Digital PCR quantification
The 35S promoter sequence in maize event Bt11 was targeted with TaqMan PCR primers40 and a specific probe with 6-FAM fluorophore and OQA quencher at 5′ and 3′ ends respectively (Table 2). The QuantStudio 3D digital PCR system (Life Technologies; California, USA) was used according to the manufacturer’s instructions to load a reaction volume of 14.5 microlitres containing 7.25 microlitres QuantStudio 3D digital PCR mastermix, 0.4 micromolar each primer, 0.2 micromolar TaqMan probe, molecular grade water and template, to a chip for thermocycling. The fluorescent signal from each chip partition was acquired and the data was analysed with QuantStudio 3D Analysis Suite web software.
“Accession codes”
Data Availability Statement
The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.
References
Carter, C. A., Gruère, G. P., McLaughlin, P. & MacLachlan, M. N. V. California’s proposition 37: effects of mandatory labeling of GM food (2012).
Holst-Jensen, A. Testing for genetically modified organisms (GMOs): Past, present and future perspectives. Biotechnology Advances 27, 1071–1082, http://www.scopus.com/inward/record.url?eid=2-s2.0-70349991410partnerID=40 md5=41a197a69429d2745aecc02cbf4506e8 (2009).
Obeid, P. J., Christopoulos, T. K. & Ioannou, P. C. Rapid analysis of genetically modified organisms by in-house developed capillary electrophoresis chip and laser-induced fluorescence system. Electrophoresis 25, 922–930, http://www.ncbi.nlm.nih.gov/pubmed/15004856 (2004).
Kalogianni, D. P., Koraki, T., Christopoulos, T. K. & Ioannou, P. C. Nanoparticle-based DNA biosensor for visual detection of genetically modified organisms. Biosens Bioelectron 21, 1069–1076, http://www.ncbi.nlm.nih.gov/pubmed/15935636 (2006).
Barbati, C. et al. Real Time PCR based GMO quantification: limits and accuracy.
Kiddle, G. et al. GMO detection using a bioluminescent real time reporter (BART) of loop mediated isothermal amplification (LAMP) suitable for field use. BMC Biotechnology 12, 15, http://www.biomedcentral.com/1472-6750/12/15 (2012).
Zahradnik, C. et al. Detection of the 35S promoter in transgenic maize via various isothermal amplification techniques: a practical approach. Anal Bioanal Chem 406, 6835–6842, http://www.ncbi.nlm.nih.gov/pubmed/24880871 (2014).
Gill, P. & Ghaemi, A. Nucleic acid isothermal amplification technologies: a review. Nucleosides Nucleotides Nucleic Acids 27, 224–243, http://www.ncbi.nlm.nih.gov/pubmed/18260008 (2008).
Asiello, P. J. & Baeumner, A. J. Miniaturized isothermal nucleic acid amplification, a review. Lab Chip 11, 1420–1430, http://www.ncbi.nlm.nih.gov/pubmed/21387067 (2011).
Haleyur Giri Setty, M. K. & Hewlett, I. K. Point of care technologies for HIV (2014).
Notomi, T. et al. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res 28, E63, http://www.ncbi.nlm.nih.gov/pubmed/10871386 (2000).
Kaneko, H., Kawana, T., Fukushima, E. & Suzutani, T. Tolerance of loop-mediated isothermal amplification to a culture medium and biological substances. J Biochem Biophys Methods 70, 499–501, http://www.ncbi.nlm.nih.gov/pubmed/17011631 (2007).
Nagamine, K., Hase, T. & Notomi, T. Accelerated reaction by loop-mediated isothermal amplification using loop primers. Mol Cell Probes 16, 223–229, http://www.ncbi.nlm.nih.gov/pubmed/12144774 (2002).
Gandelman, O., Jackson, R., Kiddle, G. & Tisi, L. Loop-mediated amplification accelerated by stem primers. Int J Mol Sci 12, 9108–9124, http://www.ncbi.nlm.nih.gov/pubmed/22272122 (2011).
Aryan, E. et al. A novel and more sensitive loop-mediated isothermal amplification assay targeting IS6110 for detection of Mycobacterium tuberculosis complex. Microbiol Res 165, 211–220, http://www.ncbi.nlm.nih.gov/pubmed/19515543 (2010).
Mori, Y., Nagamine, K., Tomita, N. & Notomi, T. Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation. Biochem Biophys Res Commun 289, 150–154, http://www.ncbi.nlm.nih.gov/pubmed/11708792 (2001).
Mori, Y., Kitao, M., Tomita, N. & Notomi, T. Real-time turbidimetry of LAMP reaction for quantifying template DNA. J Biochem Biophys Methods 59, 145–157, http://www.ncbi.nlm.nih.gov/pubmed/15163526 (2004).
Tomita, N., Mori, Y., Kanda, H. & Notomi, T. Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products. Nat Protoc 3, 877–882, http://www.ncbi.nlm.nih.gov/pubmed/18451795 (2008).
Poole, C. B. et al. Colorimetric tests for diagnosis of filarial infection and vector surveillance using noninstrumented Nucleic acid loop-mediated isothermal amplification (NINA-LAMP). PLoS ONE 12 (2017).
Zhang, X. et al. Development of a Real-Time Fluorescence Loop-Mediated Isothermal Amplification Assay for Rapid and Quantitative Detection of Fusarium oxysporum f. sp. cubense Tropical Race 4 In Soil. PLoS One 8, e82841, http://www.ncbi.nlm.nih.gov/pubmed/24376590 (2013).
Tanner, N. A., Zhang, Y. & Evans, T. C. Simultaneous multiple target detection in real-time loop-mediated isothermal amplification. Biotechniques 53, 81–89, http://www.ncbi.nlm.nih.gov/pubmed/23030060 (2012).
Ball, C. S. et al. Quenching of Unincorporated Amplification Signal Reporters in Reverse-Transcription Loop-Mediated Isothermal Amplification Enabling Bright, Single-Step, Closed-Tube, and Multiplexed Detection of RNA Viruses. Anal Chem 88, 3562–3568, http://www.ncbi.nlm.nih.gov/pubmed/26980448 (2016).
Njiru, Z. K. et al. Loop-mediated isothermal amplification (LAMP) method for rapid detection of Trypanosoma brucei rhodesiense. PLoS Negl Trop Dis 2, e147 http://www.ncbi.nlm.nih.gov/pubmed/18253475 (2008).
Patel, J. C. et al. Real-time loop-mediated isothermal amplification (RealAmp) for the species-specific identification of Plasmodium vivax. PLoS One 8, e54986, http://www.ncbi.nlm.nih.gov/pubmed/23349994 (2013).
Watts, M. R. et al. A loop-mediated isothermal amplification (LAMP) assay for Strongyloides stercoralis in stool that uses a visual detection method with SYTO-82 fluorescent dye. Am J Trop Med Hyg 90, 306–311, http://www.ncbi.nlm.nih.gov/pubmed/24323513 (2014).
Gandelman, O. A. et al. Novel bioluminescent quantitative detection of nucleic acid amplification in real-time. PLoS ONE 5, http://www.scopus.com/inward/record.url?eid=2-s2.0-78649773171partnerID=40 md5=ff63f669c57fbd3e00d390bf91762ed4 (2010).
Nyrén, P., Edwin, V., Nyren, P. & Edwin, V. Inorganic pyrophosphatase-based detection systems. II. Detection and quantification of cell lysis and cell-lysing activity. Anal Biochem 220, 46–52, http://www.scopus.com/inward/record.url?eid=2-s2.0-0028304711partnerID=40 md5=47ec0a85656d6341854a529c754e3312, http://www.ncbi.nlm.nih.gov/pubmed/7978255 (1994).
Lee, D., La Mura, M., Allnutt, T. R. & Powell, W. Detection of genetically modified organisms (GMOs) using isothermal amplification of target DNA sequences. BMC Biotechnol 9, 7, http://www.ncbi.nlm.nih.gov/pubmed/19187544 (2009).
Randhawa, G. J., Singh, M., Morisset, D., Sood, P. & Zel, J. Loop-mediated isothermal amplification: rapid visual and real-time methods for detection of genetically modified crops. J Agric Food Chem 61, 11338–11346, http://www.ncbi.nlm.nih.gov/pubmed/24188249 (2013).
Chen, X. et al. Endpoint visual detection of three genetically modified rice events by loop-mediated isothermal amplification. Int J Mol Sci 13, 14421–14433, http://www.ncbi.nlm.nih.gov/pubmed/23203072 (2012).
Gansen, A., Herrick, A. M., Dimov, I. K., Lee, L. P. & Chiu, D. T. Digital LAMP in a sample self-digitization (SD) chip. Lab Chip 12, 2247–2254, http://www.ncbi.nlm.nih.gov/pubmed/22399016 (2012).
Sun, B. et al. Mechanistic evaluation of the pros and cons of digital RT-LAMP for HIV-1 viral load quantification on a microfluidic device and improved efficiency via a two-step digital protocol. Anal Chem 85, 1540–1546, http://www.ncbi.nlm.nih.gov/pubmed/23324061 (2013).
Zhu, Q. et al. Self-priming compartmentalization digital LAMP for point-of-care. Lab Chip 12, 4755–4763, http://www.ncbi.nlm.nih.gov/pubmed/22986619 (2012).
Kiddle, G. Letter to the editor regarding “detection of the 35S promoter in transgenic maize via various isothermal amplification techniques: a practical approach”. Anal Bioanal Chem 406, 8059–8060, http://www.ncbi.nlm.nih.gov/pubmed/25384334 (2014).
Zahradnik, C. et al. Response to letter to the editor regarding “detection of the 35S promoter in transgenic maize via various isothermal amplification techniques: a practical approach”. Anal Bioanal Chem 406, 8061–8062, http://www.ncbi.nlm.nih.gov/pubmed/25354886 (2014).
Trifa, Y. & Zhang, D. DNA content in embryo and endosperm of maize kernel (Zea mays L.): impact on GMO quantification. Journal of Agricultural and Food Chemistry 52, 1044–8, http://www.ncbi.nlm.nih.gov/pubmed/14995095 (2004).
Corbisier, P. et al. Recommendation for the unit of measurement and the measuring system to report traceable and comparable results expressing GM content in accordance with EU legislation (2017).
Spalinskas, R., Van den Bulcke, M., Van den Eede, G. & Milcamps, A. LT-RADE: An Efficient User-Friendly Genome Walking Method Applied to the Molecular Characterization of the Insertion Site of Genetically Modified Maize MON810 and Rice LLRICE62. Food Analytical Methods 6, 705–713 (2013).
Morisset, D. et al. Detection of genetically modified organisms–closing the gaps. Nat Biotechnol 27, 700–701, http://www.ncbi.nlm.nih.gov/pubmed/19668172 (2009).
Wu, Y. et al. Development of a general method for detection and quantification of the P35S promoter based on assessment of existing methods. Sci Rep 4, 7358, http://www.ncbi.nlm.nih.gov/pubmed/25483893 (2014).
Artlip, T. S., Madison, J. T. & Setter, T. L. Water-Deficit in Developing Endosperm of Maize - Cell-Division and Nuclear-DNA Endoreduplication. Plant Cell and Environment 18, 1034–1040 (1995).
Engelen-Eigles, G., Jones, R. J. & Phillips, R. L. DNA endoreduplication in maize endosperm cells: The effect of exposure to short-term high temperature. Plant, Cell and Environment 23, 657–663 (2000).
Trapmann, S. Use of Certified Reference Materials for the quantification of GMO in food and feed. Tech. Rep., European Commission - Joint Research Centre Institute for Reference Materials and Measurements (IRMM), http://www.erm-crm.org/ERM_products/application_notes/application_note_4/Documents/application_note_4_english.pdf (2006).
Dube, S., Qin, J. & Ramakrishnan, R. Mathematical analysis of copy number variation in a DNA sample using digital PCR on a nanofluidic device. PLoS One 3, e2876, http://www.ncbi.nlm.nih.gov/pubmed/18682853 (2008).
Huggett, J. F. & Whale, A. Digital PCR as a novel technology and its potential implications for molecular diagnostics. Clin Chem 59, 1691–1693, http://www.ncbi.nlm.nih.gov/pubmed/24100808 (2013).
Holden, M. J., Levine, M., Scholdberg, T., Haynes, R. J. & Jenkins, G. R. The use of 35S and Tnos expression elements in the measurement of genetically engineered plant materials. Anal Bioanal Chem 396, 2175–2187, http://www.ncbi.nlm.nih.gov/pubmed/19856176 (2010).
Rosati, A., Bogani, P., Santarlasci, A. & Buiatti, M. Characterisation of 3′ transgene insertion site and derived mRNAs in MON810 YieldGard maize. Plant Mol Biol 67, 271–281, http://www.ncbi.nlm.nih.gov/pubmed/18306044 (2008).
Hernández, M., Rodríguez-Lázaro, D., Esteve, T., Prat, S. & Pla, M. Development of melting temperature-based SYBR Green I polymerase chain reaction methods for multiplex genetically modified organism detection. Anal Biochem 323, 164–170, http://www.ncbi.nlm.nih.gov/pubmed/14656521 (2003).
Gleave, A. P. A versatile binary vector system with a T-DNA organisational structure conducive to efficient integration of cloned DNA into the plant genome. Plant Mol Biol 20, 1203–1207, http://www.ncbi.nlm.nih.gov/pubmed/1463857 (1992).
Eischeid, A. C. SYTO dyes and EvaGreen outperform SYBR Green in real-time PCR. BMC Res Notes 4, 263, http://www.ncbi.nlm.nih.gov/pubmed/21798028 (2011).
Seyrig, G. et al. Selection of fluorescent DNA dyes for real-time LAMP with portable and simple optics. J Microbiol Methods 119, 223–227, http://www.ncbi.nlm.nih.gov/pubmed/26554941 (2015).
Fernandez, S. et al. Quantification of the 35S promoter in DNA extracts from genetically modified organisms using real-time polymerase chain reaction and specificity assessment on various genetically modified organisms, part I: operating procedure. J AOAC Int 88, 547–557, http://www.ncbi.nlm.nih.gov/pubmed/15859083 (2005).
Lipp, M. et al. Validation of a method based on polymerase chain reaction for the detection of genetically modified organisms in various processed foodstuffs. European Food Research and Technology 212, 497–504 (2001).
Acknowledgements
This work was supported by BBSRC Stand Alone LINK grant BB/L022346/1, a BBSRC Industrial CASE Award, and part funded by the European Regional Development Fund.
Author information
Authors and Affiliations
Contributions
P.H., G.K., L.T. and J.A.H.M. conceived the experiments, P.H. conducted the experiments, P.H. and J.A.H.M. analysed the results and wrote the manuscript. All authors reviewed the manuscript.
Corresponding author
Ethics declarations
Competing Interests
L.T. and G.K. are employees of ERBA MDX, who develop molecular assays using LAMP and the Bioluminescent Assay in Real Time (BART), and own patents WO2004/062338 and WO2006/010948 covering the use of BART and therefore declare competing financial interests. The authors are unaware of any non-financial competing interests.
Additional information
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Hardinge, P., Kiddle, G., Tisi, L. et al. Optimised LAMP allows single copy detection of 35Sp and NOSt in transgenic maize using Bioluminescent Assay in Real Time (BART). Sci Rep 8, 17590 (2018). https://doi.org/10.1038/s41598-018-36207-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-018-36207-4
Keywords
This article is cited by
-
Rapid Detection of Hepatitis A Virus in Foods Using a Bioluminescent Assay in Real-Time (BART) and Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Technology
Food and Environmental Virology (2023)
-
Bioluminescent detection of isothermal DNA amplification in microfluidic generated droplets and artificial cells
Scientific Reports (2020)
-
Full Dynamic Range Quantification using Loop-mediated Amplification (LAMP) by Combining Analysis of Amplification Timing and Variance between Replicates at Low Copy Number
Scientific Reports (2020)
-
Lack of specificity associated with using molecular beacons in loop mediated amplification assays
BMC Biotechnology (2019)
-
Reduced False Positives and Improved Reporting of Loop-Mediated Isothermal Amplification using Quenched Fluorescent Primers
Scientific Reports (2019)