Abstract
Pneumatics is one of the few actuation principles that can be used in an MR environment, since it can produce high forces without affecting imaging quality. However, pneumatic control is challenging, due to the air high compliance and cylinders non-linearities. Furthermore, the system’s properties may change for each subject. Here, we present novel control strategies that adapt to the subject’s individual anatomy and needs while performing accurate periodic gait-like movements with an MRI compatible pneumatically driven robot. In subject-passive mode, an iterative learning controller (ILC) was implemented to reduce the system’s periodic disturbances. To allow the subjects to intend the task by themselves, a zero-force controller minimized the interaction forces between subject and robot. To assist patients who may be too weak, an assist-as-needed controller that adapts the assistance based on online measurement of the subject’s performance was designed. The controllers were experimentally tested. The ILC successfully learned to reduce the variability and tracking errors. The zero-force controller allowed subjects to step in a transparent environment. The assist-as-needed controller adapted the assistance based on individual needs, while still challenged the subjects to perform the task. The presented controllers can provide accurate pneumatic control in MR environments to allow assessments of brain activation.
Similar content being viewed by others
References
Bakker M, Verstappen CCP, Bloem BR, Toni I (2007) Recent advances in functional neuroimaging of gait. J Neural Transm 114(10):1323–1331
Bristow DA, Tharayil M, Alleyne AG (2006) A survey of iterative learning control. Control Syst IEEE 26(3):96–114
Chapuis D, Gassert R, Ganesh G, Burdet E, Bleuler H (2006) Investigation of a cable transmission for the actuation of MR compatible haptic interfaces. In: Proceedings 1st International Conference on Biomedical Robotics and Biomechatronics, IEEE/RAS- EMBS, Italy, pp 426–431
Chinzei K, Hata N, Jolesz FA, Kikinis R (2000) Surgical assist robot for the active navigation in the intraoperative MRI: hardware design issues. In: Proceedings International Conference on Intelligent Robots and Systems, IEEE/RSJ, Japan, pp 727–732
Dan S, Alexandru P, Doru P, Dumitru M, Louis K (2007) A new type of motor: pneumatic step motor. IEEE/ASME Trans Mechatron 12(1):98–106
Dietz V, Gollhofer A, Kleiber M, Trippel M (1992) Regulation of bipedal stance: dependency on “load” receptors. Exp Brain Res 89(1):229–231
Dietz V, Duysens J (2000) Significance of load receptor input during locomotion: a review. Gait Posture 11(2):102–110
Dietz V, Muller R, Colombo G (2002) Locomotor activity in spinal man: significance of afferent input from joint and load receptors. Brain 125(12):2626–2634
DiMaio SP, Pieper S, Chinzei K, Hata N, Haker SJ, Kacher DF, Fichtinger G, Tempany CM, Kikinis R (2007) Robot-assisted needle placement in open MRI: system architecture, integration and validation. Comput Aided Surg 12(1):15–24
Emken JL, Benitez R, Reinkensmeyer DJ (2007) Human-robot cooperative movement training: learning a novel sensory motor transformation during walking with robotic assistance-as-needed. J Neuroeng Rehabil 4:8
Emken JL, Harkema SJ, Beres-Jones J, Ferreira CK, Reinkensmeyer DJ (2008) Feasibility of manual teach-and-replay and continuous impedance shaping for robotic locomotor training following spinal cord injury. IEEE Trans Biomed Eng 55:322–334
Fennessy FM, Tuncali K, Morrison PR, Tempany CM (2010) MR imaging-guided interventions in the genitourinary tract: an evolving concept. Magn Reson Imaging Clin N Am 18(1):11–28
Fischer GS, Iordachita I, Csoma C, Tokuda J, DiMaio SP, Tempany CM, Hata N, Fichtinger G (2008) MRI-compatible pneumatic robot for transperineal prostate needle placement. IEEE/ASME Trans Mechatron 13(3):295–305
Flueckiger M, Bullo M, Chapuis D, Gassert R, Perriard Y (2005) fMRI compatible haptic interface actuated with traveling wave ultrasonic motor. In: Proceedings Industry Applications Conference, IEE/IAS, Hong Kong, pp 2075–2082
Ganesh G, Gassert R, Burdet E, Bleuler H (2004) Dynamics and control of an MRI compatible master-slave system with hydrostatic transmission. In: Proceedings International Conference on Robotics and Automation, IEEE, New Orleans, pp 1288–1294
Gassert R, Moser R, Burdet E, Bleuler H (2006) MRI/fMRI-compatible robotic system with force feedback for interaction with human motion. IEEE/ASME Trans Mechatron 11(2):216–224
Hempel E, Fischer H, Gumb L, Höhn T, Krause H, Voges U, Breitwieser H, Gutmann B, Durke J, Bock M, Melzer A (2003) An MRI-compatible surgical robot for precise radiological interventions. Comput Aided Surg 8(4):180–191
Hollnagel C, Brügger M, Vallery H, Wolf P, Dietz V, Kollias S, Riener R (2011) Brain activity during stepping: a novel MRI-compatible device. J Neurosci Methods 201(1):124–130
Israel JF, Campbell DD, Kahn JH, Hornby TG (2006) Metabolic costs and muscle activity patterns during robotic- and therapist-assisted treadmill walking in individuals with incomplete spinal cord injury. Phys Ther 86(11):1466–1478
Khanicheh A, Muto A, Triantafyllou C, Weinberg B, Astrakas L, Tzika A, Mavroidis C (2006) fMRI-compatible rehabilitation hand device. J NeuroEng Rehabil 3(1):24
Khanicheh A, Mintzopoulos D, Weinberg B, Tzika AA, Mavroidis C (2008) MR_CHIROD v. 2: magnetic resonance compatible smart hand rehabilitation device for brain imaging. IEEE Trans Neural Syst Rehabil Eng 16(1):91–98
Lotze M, Braun C, Birbaumer N, Anders S, Cohen LG (2003) Motor learning elicited by voluntary drive. Brain 126(4):866–872
Marchal-Crespo L, Reinkensmeyer D (2009) Review of control strategies for robotic movement training after neurologic injury. J NeuroEng Rehabil 6(1):20
Marchal-Crespo L, McHughen SA, Cramer SC, Reinkensmeyer DJ (2010) The effect of aging and haptic guidance on motor learning of a steering task. Exp Brain Res 201(2):209–220
Perez MA, Lungholt BK, Nyborg K, Nielsen JB (2004) Motor skill training induces changes in the excitability of the leg cortical area in healthy humans. Exp Brain Res 159(2):197–205
Pondman KM, Fütterer JJ, ten Haken B, Schultze Kool LJ, Witjes JA, Hambrock T, Macura KJ, Barentsz JO (2008) MR-guided biopsy of the prostate: an overview of techniques and a systematic review. Eur Urol 54(3):517–527
Riener R, Lunenburger L, Jezernik S, Anderschitz JM, Colombo G, Dietz V (2005) Patient-cooperative strategies for robot-aided treadmill training: first experimental results. IEEE Trans Neural Syst Rehabil Eng 13(3):380–394
Riener R, Villgrattner T, Kleiser R, Nef T, Kollias S (2005) fMRI-compatible electromagnetic haptic interface. In: Proceedings 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS, Shanghai, pp 7024–7027
Timmermans AA, Seelen HAM, Willmann RD, Kingma H (2009) Technology-assisted training of arm-hand skills in stroke: concepts on reacquisition of motor control and therapist guidelines for rehabilitation technology design. J NeuroEng Rehabil 6:1
Tsekos NV, Khanicheh A, Christoforou E, Mavroidis C (2007) Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study. Annu Rev Biomed Eng 9(1):351–387
Xiang F, Wikander J (2004) Block-oriented approximate feedback linearization for control of pneumatic actuator system. Control Eng Pract 12(4):387–399
Yu NB, Riener R (2006) Review on MR-compatible robotic systems. Proceedings 1st International Conference on Biomedical Robotics and Biomechatronics, IEEE/RAS-EMBS, New York, pp 722–726
Yu N, Murr W, Blickenstorfer A, Kollias S, Riener R (2007) An fMRI compatible haptic interface with pneumatic actuation. In: Proceedings 10th International Conference on Rehabilitation Robotics, IEEE, Netherlands, pp 714–720
Yu N, Hollnagel C, Blickenstorfer A, Kollias S, Riener R (2008) fMRI-compatible robotic interfaces with fluidic actuation. In: Robotics: Science and Systems Conference, Zurich
Yu N, Hollnagel C, Blickenstorfer A, Kollias S, Riener R (2008) Comparison of MRI-compatible mechatronic systems with hydrodynamic and pneumatic actuation. IEEE/ASME Trans Mechatron 13(3):268–277
Acknowledgments
This work was supported in part by the EMDO foundation, Koster foundation, International foundation of paraplegia, and the Swiss National Science Foundation (SNF). Laura Marchal-Crespo holds a Marie Curie International income fellowship PIIF-GA-2010-272289. We thank Alessandro Rotta and Andreas Brunschweiler for their support in machining and assembling of MARCOS, Andrew Pennycott for proofreading, and Jasmin Schneider for her support with EMG recordings.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Hollnagel, C., Vallery, H., Schädler, R. et al. Non-linear adaptive controllers for an over-actuated pneumatic MR-compatible stepper. Med Biol Eng Comput 51, 799–809 (2013). https://doi.org/10.1007/s11517-013-1050-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-013-1050-9