Nothing Special   »   [go: up one dir, main page]

Skip to main content
Log in

Conduction block of whole nerve without onset firing using combined high frequency and direct current

  • Original Article
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

This study investigates a novel technique for blocking a nerve using a combination of direct and high frequency alternating currents (HFAC). HFAC can produce a fast acting and reversible conduction block, but cause intense firing at the onset of current delivery. We hypothesized that a direct current (DC) block could be used for a very brief period in combination with HFAC to block the onset firing, and thus establish a nerve conduction block which does not transmit onset response firing to an end organ. Experiments were performed in rats to evaluate (1) nerve response to anodic and cathodic DC of various amplitudes, (2) degree of nerve activation to ramped DC, (3) a method of blocking onset firing generated by high frequency block with DC, and (4) prolonged non-electrical conduction failure caused by DC delivery. The results showed that cathodic currents produced complete block of the sciatic nerve with a mean block threshold amplitude of 1.73 mA. Ramped DC waveforms allowed for conduction block without nerve activation; however, down ramps were more reliable than up ramps. The degree of nerve activity was found to have a non-monotonic relationship with up ramp time. Block of the onset response resulting from 40 kHz current using DC was achieved in each of the six animals in which it was attempted; however, DC was found to produce a prolonged conduction failure that likely resulted from nerve damage.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Ackermann D, Foldes E, Bhadra N, Kilgore K (2009) Effect of bipolar cuff electrode design on block thresholds in high frequency electrical neural conduction block. IEEE Trans Neural Syst Rehabil Eng 17:469–477

    Article  PubMed  Google Scholar 

  2. Ackermann D, Foldes E, Bhadra N, Kilgore K (2009) Electrode design for high frequency block: effect of bipolar separation on block thresholds and onset activity. In: Conference proceedings: annual international conference of the IEEE Engineering in Medicine and Biology Society

  3. Ackermann D, Foldes E, Bhadra N, Kilgore K (2010) Conduction block of peripheral nerve using high frequency alternating currents delivered through an intrafascicular electrode. Muscle Nerve 41(1):117–119

    Article  PubMed  Google Scholar 

  4. Ackermann D, Bhadra N, Foldes E, Kilgore K (2010) Effect of nerve cuff electrode geometry on onset response firing in conduction block of whole nerve using high frequency alternating currents. IEEE Trans Neural Syst Rehabil Eng (in press)

  5. Beebe X, Rose TL (1988) Charge injection limits of activated iridium oxide electrodes with 0.2 ms pulses in bicarbonate buffered saline (neurological stimulation application). IEEE Trans Biomed Eng 35:494–495

    Article  CAS  PubMed  Google Scholar 

  6. Bergamini CM (2004) Oxygen, reactive oxygen species and tissue damage. Curr Pharm Des 10:1611

    Article  CAS  PubMed  Google Scholar 

  7. Bhadra N, Kilgore KL (2004) Direct current electrical conduction block of peripheral nerve. IEEE Trans Neural Syst Rehabil Eng 12:313

    Article  PubMed  Google Scholar 

  8. Bhadra N, Kilgore KL (2005) High-frequency electrical conduction block of mammalian peripheral motor nerve. Muscle Nerve 32:782

    Article  PubMed  Google Scholar 

  9. Bhadra N, Bhadra N, Kilgore K, Gustafson KJ (2006) High frequency electrical conduction block of the pudendal nerve. J Neural Eng 3:180

    Article  PubMed  Google Scholar 

  10. Boger A, Bhadra N, Gustafson KJ (2008) Bladder voiding by combined high frequency electrical pudendal nerve block and sacral root stimulation. Neurourol Urodyn 27:435

    Article  PubMed  Google Scholar 

  11. Bowman B, McNeal D (1986) Response of single alpha motorneurons to high-frequency pulse trains. Appl Neurophysiol 49:121–138

    CAS  PubMed  Google Scholar 

  12. Brindley GS (1980) A technique for anodally blocking large nerve fibres through chronically implanted electrodes. J Neurol Neurosurg 43:1083

    Article  CAS  Google Scholar 

  13. Casey KL, Blick M (1969) Observations on anodal polarization of cutaneous nerve. Brain Res 13:155

    Article  CAS  PubMed  Google Scholar 

  14. ElBasiouny SM, Mushahwar VK (2007) Modulation of motoneuronal firing behavior after spinal cord injury using intraspinal microstimulation current pulses: a modeling study. J Appl Physiol 103:276–286

    Article  PubMed  Google Scholar 

  15. Foldes E, Ackermann D, Bhadra N, Kilgore K (2009) Counted cycles method to quantify the onset activity in high-frequency peripheral nerve block. In: Conference proceedings: annual international conference of the IEEE Engineering in Medicine and Biology Society, pp 614–617

  16. Gaunt R, Prochazka A (2009) Transcutaneously coupled, high-frequency electrical stimulation of the pudendal nerve blocks external urethral sphincter contractions. Neurorehabil Neural Repair 23:615

    Article  PubMed  Google Scholar 

  17. Goldman L, Albus J (1968) Computation of impulse conduction in myelinated fibers: theoretical basis of the velocity-diameter relation. Biophys J 8:596–607

    Article  CAS  PubMed  Google Scholar 

  18. Guyton DL (1974) Theory and design of capacitor electrodes for chronic stimulation. Medical 12:613

    CAS  Google Scholar 

  19. Guz A (1971) The role of non-myelinated vagal afferent fibres from the lungs in the genesis of tachypnoea in the rabbit. J Physiol (Paris) 213:345

    CAS  Google Scholar 

  20. Hennings K (2005) Orderly activation of human motor neurons using electrical ramp prepulses. Clin Neurophysiol 116:597

    Article  PubMed  Google Scholar 

  21. Joseph L, Haeffele BD, Butera RJ (2007) Conduction block induced by high frequency AC stimulation in unmyelinated nerves. In: Conference proceedings: annual international conference of the IEEE Engineering in Medicine and Biology Society, vol 2007, pp 1719

  22. Karu ZZ, Durfee WK, Barzilai AM (1995) Reducing muscle fatigue in FES applications by stimulating with N-let pulse trains. IEEE Trans Biomed Eng 42:809

    Article  CAS  PubMed  Google Scholar 

  23. Kilgore K, Bhadra N (2004) Nerve conduction block utilizing high-frequency alternating current. Med Biol Eng Comput 42:394–406

    Article  CAS  PubMed  Google Scholar 

  24. Kilgore K, Foldes E, Ackermann D, Bhadra N (2009) Combined direct current and high frequency nerve block for elimination of the onset response. Presented at Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE

  25. Kuffler SW (1947) The small-nerve motor system to skeletal muscle. J Neurophysiol 10:383

    CAS  PubMed  Google Scholar 

  26. Kuffler SW (1953) Small-nerve junctional potentials. The distribution of small motor nerves to frog skeletal muscle, and the membrane characteristics of the fibres they innervate. J Physiol (Paris) 121:289

    CAS  Google Scholar 

  27. Manfredi M (1970) Differential block of conduction of larger fibers in peripheral nerve by direct current. Arch Ital Biol 108:52

    CAS  PubMed  Google Scholar 

  28. McCloskey DI (1972) Reflex cardiovascular and respiratory responses originating in exercising muscle. J Physiol (Paris) 224:173

    CAS  Google Scholar 

  29. Merrill D (2005) Electrical stimulation of excitable tissue: design of efficacious and safe protocols. J Neurosci Methods 141:171

    Article  PubMed  Google Scholar 

  30. Miles JD, Kilgore K, Bhadra N, Lahowetz E (2007) Effects of ramped amplitude waveforms on the onset response of high-frequency mammalian nerve block. J Neural Eng 4:390

    Article  CAS  PubMed  Google Scholar 

  31. Petruska JC, Hubscher CH, Johnson RD (1998) Anodally focused polarization of peripheral nerve allows discrimination of myelinated and unmyelinated fiber input to brainstem nuclei. Exp Brain Res Experimentelle Hirnforschung Experimentation Cerebrale 121:379

    CAS  Google Scholar 

  32. Pflüger E (1858) Untersuchungen Uber die Physiologie des Electrotonus. Hirschwald, Berlin

    Google Scholar 

  33. Rosenblueth A, Reboul J (1939) The blocking and deblocking effects of alternating currents on nerve. Am J Physiol 125:251–264

    Google Scholar 

  34. Sassen M, Zimmermann M (1973) Differential blocking of myelinated nerve fibres by transient depolarization. Pflugers Arch 341:179

    Article  CAS  PubMed  Google Scholar 

  35. Scheiner A, Mortimer J, Roessmann U (1990) Imbalanced biphasic electrical stimulation: muscle tissue damage. Ann Biomed Eng 18:407–425

    Article  CAS  PubMed  Google Scholar 

  36. Schmalbruch H (1986) Fiber composition of the rat sciatic nerve. Anat Rec 215:71

    Article  CAS  PubMed  Google Scholar 

  37. Sweeney JD, Mortimer JT (1986) An asymmetric two electrode cuf for generation of unidirectionally propagated action potentials. IEEE Trans Biomed Eng BME-33:541–549

    Article  Google Scholar 

  38. Tai C, Roppolo JR, de Groat WC (2004) Block of external urethral sphincter contraction by high frequency electrical stimulation of pudendal nerve. J Urol 172:2069–2072

    Article  PubMed  Google Scholar 

  39. Van Den Honert C, Mortimer JT (1981) A technique for collision block of peripheral nerve: single stimulus analysis. IEEE Trans Biomed Eng BME-28:373

    Article  Google Scholar 

  40. Whitwam JG, Kidd C (1975) The use of direct current to cause selective block of large fibres in peripheral nerves. Br J Anaesth 47:1123

    Article  CAS  PubMed  Google Scholar 

  41. Williamson RP, Andrews BJ (2005) Localized electrical nerve blocking. IEEE Trans Biomed Eng 52:362

    Article  PubMed  Google Scholar 

  42. Woo MY, Campbell B (1964) Asynchronous firing and block of peripheral nerve conduction by 20 kC alternating current. Bull Los Angel Neurol Soc 29:87

    CAS  Google Scholar 

  43. Zimmermann M (1968) Selective activation of C-fibers. Pflugers Arch 301:329

    Article  CAS  Google Scholar 

Download references

Acknowledgment

This study was funded by NIBIB Grant R01-EB002091.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to D. Michael Ackermann Jr..

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ackermann, D.M., Bhadra, N., Foldes, E.L. et al. Conduction block of whole nerve without onset firing using combined high frequency and direct current. Med Biol Eng Comput 49, 241–251 (2011). https://doi.org/10.1007/s11517-010-0679-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-010-0679-x

Keywords

Navigation