Abstract
A computational method was developed for the measurement of breast density using chest computed tomography (CT) images and the correlation between that and mammographic density. Sixty-nine asymptomatic Asian women (138 breasts) were studied. With the marked lung area and pectoralis muscle line in a template slice, demons algorithm was applied to the consecutive CT slices for automatically generating the defined breast area. The breast area was then analyzed using fuzzy c-mean clustering to separate fibroglandular tissue from fat tissues. The fibroglandular clusters obtained from all CT slices were summed then divided by the summation of the total breast area to calculate the percent density for CT. The results were compared with the density estimated from mammographic images. For CT breast density, the coefficient of variations of intraoperator and interoperator measurement were 3.00 % (0.59 %–8.52 %) and 3.09 % (0.20 %–6.98 %), respectively. Breast density measured from CT (22 ± 0.6 %) was lower than that of mammography (34 ± 1.9 %) with Pearson correlation coefficient of r = 0.88. The results suggested that breast density measured from chest CT images correlated well with that from mammography. Reproducible 3D information on breast density can be obtained with the proposed CT-based quantification methods.
Similar content being viewed by others
References
McCormack, V. A., and Silva, I. D. S., Breast density and parenchymal patterns as markers of breast cancer risk: A meta-analysis. Cancer Epidemiol. Biomarkers 15(6):1159–1169, 2006. doi:10.1158/1055-9965-Epi-06-0034.
Boyd, N. F., Guo, H., Martin, L. J., Sun, L. M., Stone, J., Fishell, E., Jong, R. A., Hislop, G., Chiarelli, A., Minkin, S., and Yaffe, M. J., Mammographic density and the risk and detection of breast cancer. N. Engl. J. Med. 356(3):227–236, 2007.
van Duijnhoven, F. J. B., Peeters, P. H. M., Warren, R. M. L., Bingham, S. A., van Noord, P. A. H., Monninkhof, E. M., Grobbee, D. E., and van Gils, C. H., Postmenopausal hormone therapy and changes in mammographic density. J. Clin. Oncol. 25(11):1323–1328, 2007. doi:10.1200/Jco.2005.04.7332.
Cuzick, J., Warwick, J., Pinney, E., Duffy, S. W., Cawthorn, S., Howell, A., Forbes, J. F., and Warren, R. M. L., Tamoxifen-induced reduction in mammographic density and breast cancer risk reduction: A nested case-control study. J. Natl. Cancer Inst. 103(9):744–752, 2011. doi:10.1093/Jnci/Djr079.
American College of Radiology, Breast Imaging Reporting and Data System, 4th edition. American College of Radiology, Reston, 2003.
Harvey, J. A., and Bovbjerg, V. E., Quantitative assessment of mammographic breast density: Relationship with breast cancer risk. Radiology 230(1):29–41, 2004. doi:10.1148/radiol.2301020870.
Heine, J. J., Cao, K., Rollison, D. E., Tiffenberg, G., and Thomas, J. A., A quantitative description of the percentage of breast density measurement using full-field digital mammography. Acad. Radiol. 18(5):556–564, 2011. doi:10.1016/j.acra.2010.12.015.
Nie, K., Chen, J.-H., Chan, S., Chau, M.-K. I., Hon, J. Y., Bahri, S., Tseng, T., Nalcioglu, O., and Su, M.-Y., Development of a quantitative method for analysis of breast density based on three-dimensional breast MRI. Med. Phys. 35:5253, 2008.
Boyd, N., Martin, L., Chavez, S., Gunasekara, A., Salleh, A., Melnichouk, O., Yaffe, M., Friedenreich, C., Minkin, S., and Bronskill, M., Breast-tissue composition and other risk factors for breast cancer in young women: A cross-sectional study. Lancet Oncol. 10(6):569–580, 2009. doi:10.1016/S1470-2045(09)70078-6.
Moon, W. K., Shen, Y. W., Huang, C. S., Luo, S. C., Kuzucan, A., Chen, J. H., and Chang, R. F., Comparative study of density analysis using automated whole breast ultrasound and MRI. Med. Phys. 38(1):382–389, 2011. doi:10.1118/1.3523617.
Nie, K., Chen, J. H., Chan, S., Chau, M. K. I., Yu, H. J., Bahri, S., Tseng, T., Nalcioglu, O., and Su, M. Y., Development of a quantitative method for analysis of breast density based on three-dimensional breast MRI. Med. Phys. 35(12):5253–5262, 2008. doi:10.1118/1.3002306.
Liu, Y., Bellomi, M., Gatti, G., and Ping, X., Accuracy of computed tomography perfusion in assessing metastatic involvement of enlarged axillary lymph nodes in patients with breast cancer. Breast Cancer Res. 9(4):R40, 2007. doi:10.1186/Bcr1738.
Isaacs, R. J., Ford, J. M., Allan, S. G., Forgenson, G. V., and Gallagher, S., Role of computed-tomography in the staging of primary breast-cancer. Br. J. Surg. 80(9):1137–1137, 1993.
Prionas, N. D., Lindfors, K. K., Ray, S., Huang, S. Y., Beckett, L. A., Monsky, W. L., and Boone, J. M., Contrast-enhanced dedicated breast CT: Initial clinical experience. Radiology 256(3):714–723, 2010. doi:10.1148/radiol.10092311.
Lindfors, K. K., Boone, J. M., Newell, M. S., and D’Orsi, C. J., Dedicated breast computed tomography: The optimal cross-sectional imaging solution? Radiol. Clin. N. Am. 48(5):1043, 2010. doi:10.1016/j.rcl.2010.06.001.
Aberle, D. R., Adams, A. M., Berg, C. D., Black, W. C., Clapp, J. D., Fagerstrom, R. M., Gareen, I. F., Gatsonis, C., Marcus, P. M., Sicks, J. D., and Team NLSTR, Reduced lung-cancer mortality with low-dose computed tomographic screening. N. Engl. J. Med. 365(5):395–409, 2011. doi:10.1056/Nejmoa1102873.
Megumi Kuchiki, T. H., and Fukao, A., Assessment of breast cancer risk based on mammary gland volume measured with CT. Breast Cancer Basic Clin. Res. 4:57–64, 2010.
Juneja, P., Harris, E. J., Kirby, A. M., and Evans, P. M., Adaptive breast radiation therapy using modeling of tissue mechanics: A breast tissue segmentation study. Int. J. Radiat. Oncol. Biol. Phys. 84:e419–e425, 2012.
Yang, X. F., Wu, S. Y., Sechopoulos, I., and Fei, B. W., Cupping artifact correction and automated classification for high-resolution dedicated breast CT images Xiaofeng Yang and Shengyong Wu. Med. Phys. 39(10):6397–6406, 2012. doi:10.1118/1.4754654.
Hou, J. D., Guerrero, M., Chen, W. J., and D’Souza, W. D., Deformable planning CT to cone-beam CT image registration in head-and-neck cancer. Med. Phys. 38(4):2088–2094, 2011. doi:10.1118/1.3554647.
Thirion, J. P., Image matching as a diffusion process: An analogy with Maxwell’s demons. Med. Image Anal. 2(3):243–260, 1998.
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., and Hawkes, D. J., Nonrigid registration using free-form deformations: Application to breast MR images. IEEE Trans. Med. Imaging 18(8):712–721, 1999.
Lin, M. Q., Chen, J. H., Mehta, R. S., Bahri, S., Chan, S. W., Nalcioglu, O., and Su, M. Y., Spatial shrinkage/expansion patterns between breast density measured in two MRI scans evaluated by non-rigid registration. Phys. Med. Biol. 56(18):5865–5875, 2011. doi:10.1088/0031-9155/56/18/006.
Wang, H., Dong, L., O’Daniel, J., Mohan, R., Garden, A. S., Ang, K. K., Kuban, D. A., Bonnen, M., Chang, J. Y., and Cheung, R., Validation of an accelerated ‘demons’ algorithm for deformable image registration in radiation therapy. Phys. Med. Biol. 50(12):2887–2905, 2005. doi:10.1088/0031-9155/50/12/011.
Van den Bulcke, J., Boone, M., Van Acker, J., and Van Hoorebeke, L., Three-dimensional X-ray imaging and analysis of fungi on and in wood. Microsc. Microanal. 15(5):395–402, 2009. doi:10.1017/S1431927609990419.
Keator, D. B., Fallon, J. H., Lakatos, A., Fowlkes, C. C., Potkin, S. G., and Ihler, A., Feed-forward hierarchical model of the ventral visual stream applied to functional brain image classification. Hum. Brain Mapp. 2012. doi:10.1002/hbm.22149.
Liao, C. C., Xiao, F. R., Wong, J. M., and Chiang, I. J., Automatic recognition of midline shift on brain CT images. Comput. Biol. Med. 40(3):331–339, 2010. doi:10.1016/j.compbiomed.2010.01.004.
Field, A. P., Discovering Statistics Using SPSS, 3rd edition. SAGE Publications, Los Angeles, 2009.
Joachim, N., Rochtchina, E., Tan, A. G., Hong, T., Mitchell, P., and Wang, J. J., Right and left correlation of retinal vessel caliber measurements in anisometropic children: Effect of refractive error. Invest. Ophthalmol. Vis. Sci. 53(9):5227–5230, 2012. doi:10.1167/Iovs.12-9422.
Uyamker, B., Rajapakshe, R., Gordon, P., and Silver, S., Quest for a “gold standard” for breast density evaluation. Med. Phys. 36(9):4305–4305, 2009.
Highnam, R., Brady, M., Yaffe, M., Karssemeijer, N., and Harvey, J., Robust Breast Composition Measures – Volpara. Paper presented at the International Workshop on Digital Mammography: Girona, Spain, 2010.
Acknowledgments
The authors thank the National Science Council (NSC 99-2221-E-002-136-MY3), Ministry of Economic Affairs (100-EC-17-A-19-S1-164) of the Republic of China and National Taiwan University (101R890863) for the funding support. This work was supported by the Industrial Strategic Technology Development Program (10042581) funded by the Ministry of Knowledge Economy (MKE, Korea) and the National Research Foundation of Korea (NRF) grant funded by the Korea government (MEST) (No. 2012-01010846).
Conflict of Interest
The authors declare that they have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Moon, W.K., Lo, CM., Goo, J.M. et al. Quantitative Analysis for Breast Density Estimation in Low Dose Chest CT Scans. J Med Syst 38, 21 (2014). https://doi.org/10.1007/s10916-014-0021-5
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s10916-014-0021-5