Abstract
The purpose of contrast-enhanced digital mammography (CEDM) is to facilitate detection and characterization of the lesions in the breast using intravenous injection of an iodinated contrast agent. CEDM produces iodine images with gray levels proportional to iodine concentration at each pixel, which can be considered as quantification of iodine. While dual-energy CEDM requires an accurate knowledge of the thickness of compressed breast for the quantification, it is known that the accuracy of the built-in thickness measurement is not satisfactory. Triple-energy CEDM, which can provide a third image, can alleviate the limitation of dual-energy CEDM. If triple exposure technique is applied, it can lead to increased risk of motion artifact. An energy-resolving photon-counting detector (PCD) that can acquire multispectral X-ray images can reduce the risk of motion artifact. In this research, an easily implementable method for iodine quantification in breast imaging was suggested, and it was applied to the images of breast phantom with various iodine concentrations. The iodine concentrations in breast phantom simulate lesions filled with different iodine concentrations in the breast. The result shows that the proposed method can quantify the iodine concentrations in breast phantom accurately.
Similar content being viewed by others
References
Thomas R. Nelson, Laura I. Cerviño, John M. Boone, and Karen K. Lindfors: Classification of breast computed tomography data. Medical Physics, 2008
Clarisse Dromain, Corinne Balleyguier, Ghazal Adler, Jean Remi Garbay, Suzette Delaloge: Contrast-enhanced digital mammography. European Journal of Radiology, 2009
John M. Lewin, Pamela K. Isaacs, Virginia Vance, Fred J. Larke: Dual-Energy Contrast enhanced Digital Subtraction Mammography: Feasibility. Radiology, October 2003
Clarisse Dromain, Fabienne Thibault, Felix Diekmann, Eva M. Fallenberg, Roberta A. Jong, Marcia Koomen, R. Edward Hendrick, Anne Tardivon and Alicia Toledano: Dual-energy contrast-enhanced digital mammography: initial clinical results of a multireader, multicase study. Breast Cancer Research, 2012
Maxine Jochelson: Contrast-Enhanced Digital Mammography. Radiologic Clinics of North America, 2014
Yu Zou and Michael D. Silver: Analysis of Fast kV-switching in Dual Energy CT using a Prereconstruction Decomposition Technique. Proceeding of SPIE, March 2008
Serghei Malkov, Jeff Wang, Karla Kerlikowske, Steven R. Cummings, and John A. Shepherd: Single x-ray absorptiometry method for the quantitative mammographic measure of fibroglandular tissue volume. Medical Physics, 2009
Albert H. Tyson, Gordon E. Mawdsley, and Martin J. Yaffe: Measurement of compressed breast thickness by optical stereoscopic photogrammetry. Medical Physics, 2009
A. Burch and J. Law: A method for estimating compressed breast thickness during mammography. British Journal of Radiology, 1995
P.V. Granton, S.I. Pollmann, N.L. Ford, M. Drangova, and D.W. Holdsworth: Implementation of dual- and triple-energy cone-beam micro-CT for postreconstruction material decomposition. Medical Physics, 2008
J. P. Schlomka, E. Roessl, R. Dorscheid, S. Dill, G. Martens, T. Istel, C. Bäumer, C. Herrmann, R. Steadman, G. Zeitler, A. Livne and R. Proksa: Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography. Physics in Medicine and Biology, 2008
Markus Firsching, Patrick Takoukam Talla, Thilo Michel, Gisela Anton: Material resolving X-ray imaging using spectrum reconstruction with Medipix2. Nuclear Instruments and Methods in Physics Research Section A, 2008
P. S. Yeh, A. Macovski, and W. Brody: Noise analysis in isolation of iodine using three energies. Medical Physics, 1980
F. Kelcz. and C.A. Mistretta: Absorption-edge fluoroscopy using a three-spectrum technique. Medical Physics, 1976.
S. Puong, P. Milioni de Carvalho, and S. Muller: Triple-Energy Contrast Enhanced Digital Mammography. Proc. of SPIE, 2010
Seokmin Han, Dong-Goo Kang, Sunghoon Kang, Younghun Sung: Quantitative breast imaging using photon counting detector. Proc. SPIE. 8668, Medical Imaging, 2013
Seokmin Han, Dong-Goo Kang: Tissue cancellation in dual energy mammography using a calibration phantom customized for direct mapping. IEEE Transactions on Medical Imaging, 2014
D.R. Dance, C.L. Skinner, K.C. Young, J.R. Beckett, C.J. Kotre: Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol. Physics in Medicine and Biology, 2000
D.R. Dance: Monte Carlo calculation of conversion factors for the estimation of mean glandular breast dose. Physics in Medicine and Biology, 1990
William P. Argo, Kathleen Hintenlang, and David E. Hintenlang: A tissue-equivalent phantom series for mammography dosimetry. Journal of Applied Clinical Medical Physics, Vol 5, No 4, 2004
Grant E. van der Ploeg, Robert T. Withers, and Joe Laforgia: Percent body fat via DEXA: comparison with a four-compartment model. Journal of Applied Physiology, February 2003
Angelo Pietrobelli, Zimian Wang, Carmelo Formica, and Steven B. Heymsfield: Dual-energy X-ray absorptiometry: fat estimation errors due to variation in soft tissue hydration. Americal Journal of Physiology Endocrinology and Metabolism, May 1998
J.T.M. Jansen,W.J.H. Veldkamp, M.A.O. Thijssen, S. van Woudenberg, and J. Zoetelief: Method for determination of the mean fraction of glandular tissue in individual female breasts using mammography. Physics in Medicine and Biology, 2005
Christopher E Tromans, Mary R Cocker and Sir Michael Brady: Quantification and normalization of x-ray mammograms. Physics in Medicine and Biology, 2012
P. Baldelli,A. Bravin, C. Di Maggio, G. Gennaro, A. Sarnelli, A. Taibi, M. Gambaccini: Evaluation of the minimum iodine concentration for contrast-enhanced subtraction. Physics in Medicine and Biology, 2006
Robert A. Kruger: Estimation of the diameter of and iodine concentration within blood vessels using digital radiography devices. Med Phys, 1981
T. P. Fuerst, M. S. Van Lysel: Measurement of absolute blood iodine concentration during digital subtraction ventriculography. Med Phys, 1993
Felix Diekmann, Ulrich Bick: Tomosynthesis and contrast-enhanced digital mammography: recent advances in digital mammography. Eur Radiol, 2007
Masatoshi Saito: Dual-energy approach to contrast-enhanced mammography using the balanced filter method: spectral optimization and preliminary phantom measurement. Med Phys, 2007
Robert Leithner, Thomas Knogler and Peter Homolka: Development and production of a prototype iodine contrast phantom for CEDEM. Phys Med Biol, 2013
S. Eva Singletary, Craig Allred, Pandora Ashley, Lawrence W. Bassett, Donald Berry, Kirby I. Bland, Patrick I. Borgen, Gary Clark, Stephen B. Edge, Daniel F. Hayes, Lorie L. Hughes, Robert V.P. Hutter, Monica Morrow, David L. Page, Abram Recht, Richard L. Theriault, Ann Thor, Donald L. Weaver, H. Samuel Wieand and Frederick L. Greene: Revision of the American Joint Committee on Cancer Staging System for Breast Cancer. Journal of Clinical Oncology, July 2002
E. Fredenberg, M. Hemmendorff, B. Cederström, M. Åslund, and M. Danielsson: Contrast-enhanced spectral mammography with a photon-counting detector. Medical Physics, 2010
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Han, S. A Quantification Method for Breast Tissue Thickness and Iodine Concentration Using Photon-Counting Detector. J Digit Imaging 28, 594–603 (2015). https://doi.org/10.1007/s10278-015-9784-6
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10278-015-9784-6