Abstract
An important aspect of positron emission tomography (PET) imaging in a clinical application is the localization and detection of tumors and lesions by administering a predetermined amount of radiotracer. This allows detailed 3D imaging of a wide range of molecular processes in the human body. The quality of the PET image is dependent on the amount of radiotracer administrated and the patient’s body parameters. As the amount of injected radiotracer increases, an overall improvement in the quality of the reconstructed PET images and lesion detectability is expected, but it is accepted that any radiotracer doses are associated with the risk of radiation and it could be harmful to the patient if essential PET imaging is not performed because of the fear of radiation risk. To ensure the highest-quality diagnosis and the smallest radiation risk, the patient should receive the smallest amount of radiotracer that provides an image of sufficient quality. Our study proposed a PET simulation tool to predict the smallest amount of radiotracer that allows for a reliable diagnosis based on patients’ significant body parameters (weight, age) within a fixed total scan time to improve diagnostic processes for detecting and localizing tumors. We built a model of a particular PET scanner and patient, based on real MRI images and a digital anthropomorphic phantom of the brain. We performed Monte Carlo simulations of PET data acquisitions. A dataset of 60 patients was used, and 11 independent dose prediction simulations were performed for each patient. We concluded that our simulator estimated injected radiotracer doses 28% smaller than the standard clinical doses that yielded PET images of clinically acceptable quality. We also found that the total injected radiotracer dose for adult patients was affected by considering the patient’s weight rather than age.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.References
Accorsi R, Karp JS, Surti S (2010) Improved dose regimen in pediatric PET. J Nucl Med 51(2):293–300
Alsanea E (2016) Prediction of radioactive injection dosage for PET image. King Abdul Aziz university
Augusto RS, Mohammadi A, Tashima H, Yoshida E, Yamaya T, Ferrari A, Parodi K (2018) Experimental validation of the FLUKA Monte Carlo code for dose and β2 -emitter predictions of radioactive ion beams. Phys Med Biol 63(21):215014
Boellaard R, O’Doherty MJ, Weber WA, Mottaghy FM, Lonsdale MN, Stroobants SG, Oyen WJ, Kotzerke J, Hoekstra OS, Pruim J (2010) FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0. Eur J Nucl Med Mol Imaging 37(1):181–200
Boldyš J, Dvořák J, Skopalová M, Bělohlávek O (2013) Monte Carlo simulation of PET images for injection dose optimization. Int J Numer Methods Biomed Eng 29(9):988–999
Cherry SR (2009) Multimodality imaging: beyond pet/ct and spect/ct. Semin Nucl Med 39:348–353
de SEOB Silva (2010) Small animal PET imaging using GATE Monte Carlo simulations: implementation of physiological and metabolic information
Dvořák J, Boldyš J, Skopalová M, Bělohlávek O (2013) Application of the random field theory in PET imaging-injection dose optimization. Kybernetika 49(2):280–300
Gillam JE, Rafecas M (2016) Monte-Carlo simulations and image reconstruction for novel imaging scenarios in emission tomography. Nucl Instrum Methods Phys Res Sect Accel Spectrometers Detect Assoc Equip 809:76–88
Kang J, Gao Y, Shi F, Lalush DS, Lin W, Shen D (2015) Prediction of standard-dose brain PET image by using MRI and low-dose brain [18F]FDG PET images. Med Phys 42:5301–5309
Karakatsanis NA, Loudos G, Rahmim A, Nikita KS (2014) Monte-Carlo based characterization of the counting rate (NECR) response for personalized optimization of the administered activity in clinical PET imaging. Front Biomed Technol 1(1):14–34
Ljungberg M (2004) Simulation techniques and phantoms. In: Emission tomography, the fundamentals of PET and SPECT, Elsevier Inc., pp 551–563
Mawlawi O (2009) DW Townsend (2009) Multimodality imaging: an update on PET/CT technology. Eur J Nucl Med Mol Imaging 36(1):15–29
Peter J, Tornia M, Jaszczek R (2000) Analytical versus voxelized phantom representation for Monte Carlo simulation in radiological imaging. Med Imaging IEEE Trans 19(5):556–564
Piepsz A, Hahn K, Roca I, Ciofetta G, Toth G, Gordon I, Kolinska J, Gwidlet J (1990) A radiopharmaceuticals schedule for imaging in paediatrics. Eur J Nucl Med 17(3–4):127–129
Saha GB (2010) Basics of PET imaging: physics, chemistry, and regulations. Springer, Berlin
Treves ST, Baker A, Fahey FH, Cao X, Davis RT, Drubach LA, Grant FD, Zukotynski K (2011) Nuclear medicine in the first year of life. J Nucl Med 52(6):905–925
Turco A (2012) Monte Carlo simulations of a small-animal PET scanner. Analysis of performances and comparison between camera designs
Waterstram-Rich KM, Christian PE (2013) Nuclear medicine and PET/CT: technology and techniques. Elsevier, Amsterdam
Xu J, Gong E, Pauly P, Zaharchuk G (2017) 200x low-dose PET reconstruction using deep learning
Yu S (2010) Simulation of PET brain images using Monte Carlo method. Master Thesis in Medical Imaging, School of Technology and Health Royal Institute of Technology, Stockholm, Sweden
Zaidi H (1999) Relevance of accurate Monte Carlo modeling in nuclear medical imaging. Med Phys 26(4):574–608
Zaidi H, Koral K (2006) Scatter correction strategies in emission tomography. In: Quantitative analysis in nuclear medicine imaging, Springer, pp 205–235
Acknowledgements
The project was funded by the Deanship of Scientific Research (DSR), King Abdulaziz University, Jeddah, under Grant No. (DF-578-611-1441). The authors, therefore, gratefully acknowledge DSR technical and financial support.
Funding
There was no fund for this study.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Alsanea, E., Alhalabi, W. Prediction of radioactive injection dosage for PET imaging. Soft Comput 25, 5847–5854 (2021). https://doi.org/10.1007/s00500-021-05577-9
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00500-021-05577-9