Abstract
It is generally believed that digital mammography is the most promising technique for early detection of breast-cancer[1]. However, there are many technological challenges associated with digital mammography. With the high resolution and low noise needed for detection of micro-calcifications and low contrast tumors, a tremendous amount of data has to be acquired and read out in a few seconds. This puts difficult constraints on electronics and the data-acquisiton system.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Shtern F (1992) Digital technology and related technology: a perspective from the National Cancer Institute. Radiology 183, 629–630.
Beuville E, Cederström B, Danielsson M, Luo L, Nygren D, Oltman E, Vestlund J (1998) An application specific integrated circuit and data acquisition system for digital x-ray imaging. Nucl. Instr. and Meth. A, in press.
Beuville E, Cahn R, Cederström B, Danielsson M, Hall A, Lundqvist M, Luo L, Nygren D, Oltman E (1998) High resolution scanned-slit x-ray imaging using a refractive lens for x-ray focusing. Proc. SPIE, Physics of Medical Imaging 3336.
YafTe M (1993) Digital Mammography. RSNA Categorical Course in Phys., 271–82.
Lundqvist M (1998) Measurments of thresholds and noise in electronics and silicon detector computer simulations for a digital x-ray imaging system. Master’s Thesis, Royal Institute of Technology, Stockholm, Sweden.
Campbell M, Heijne E et al (1997) Readout for a 64 × 64 pixel matrix with 15-bit single photon counting. Proc. IEEE Nucl. Sci. Symp. and Med. Imaging Conf.
Birch R, Marshall M and Ardran G (1979) Catalogue of spectral data for diagnostic x-rays. The Hospital Physicists’ Association, London, UK.
Snigirev A, Kohn V et al (1996) A compound refractive lens for focusing high-energy X-rays. Nature Vol. 384, pp. 49–51.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1998 Springer Science+Business Media Dordrecht
About this chapter
Cite this chapter
Beuville, E. et al. (1998). High Resolution Mammography Using a Scanned Slit Silicon Strip Detector. In: Karssemeijer, N., Thijssen, M., Hendriks, J., van Erning, L. (eds) Digital Mammography. Computational Imaging and Vision, vol 13. Springer, Dordrecht. https://doi.org/10.1007/978-94-011-5318-8_4
Download citation
DOI: https://doi.org/10.1007/978-94-011-5318-8_4
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-010-6234-3
Online ISBN: 978-94-011-5318-8
eBook Packages: Springer Book Archive