Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

CERN Document Server 找到 2,036 笔记录  1 - 10下一个最後  跳到记录: 检索需时 0.64 秒. 
1.
Large-Scale Production of Monitored Drift Tube Chambers for the ATLAS Muon Spectrometer / Bauer, F. (Munich, Max Planck Inst.) ; Horvat, S ; Kortner, O ; Kroha, H ; Manz, A ; Mohrdieck, S ; Richter, R ; Zhuravlov, V
Precision drift tube chambers with a sense wire positioning accuracy of better than 20 microns are under construction for the ATLAS muon spectrometer. 70% of the 88 large chambers for the outermost layer of the central part of the spectrometer have been assembled. [...]
arXiv:1604.00240; MPI-PHE-2003-04; MPP-2003-151; MPP-2003-151.- 2016 - 4 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 518 (2004) 69-72 Fulltext: PDF; External link: Preprint
In : 9th Pisa Meeting on Advanced Detectors, La Biodola, Italy, 25 - 31 May 2003, pp.69
2.
Upgrades of the ATLAS Muon Spectrometer with sMDT Chambers / Ferretti, Claudio (University of Michigan, Department of Physics) ; Kroha, Hubert (Max-Planck-Institut fuer Physik)
With half the drift-tube diameter of the Monitored Drift Tube (MDT) chambers of the ATLAS muon spectrometer and otherwise unchanged operating parameters, small-diameter Muon Drift Tube (sMDT) chambers provide an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit. [...]
ATL-MUON-PROC-2015-006.
- 2015. - 2 p.
Original Communication (restricted to ATLAS) - Full text - Full text
3.
Construction of monitored drift tube chambers for ATLAS end-cap muon spectrometer at IHEP (Protvino) / Bensinger, J ; Bozhko, N ; Borisov, A ; Fakhrutdinov, R M ; Goryatchev, S ; Goryachev, V N ; Gushchin, V ; Hashemi, K S ; Kojine, A ; Kononov, A I et al.
Trapezoidal-shaped Monitored Drift Tube (MDT) chambers will be used in end-caps of ATLAS muon spectrometer. Design and construction technology of such chambers in IHEP (Protvino) is presented. [...]
2002 - Published in : Nucl. Instrum. Methods Phys. Res., A 494 (2002) 480-486
4.
Construction and test of high precision drift-tube (sMDT) chambers for the ATLAS muon spectrometer / Nowak, Sebastian (Munich, Max Planck Inst.) ; Kortner, Oliver (Munich, Max Planck Inst.) ; Kroha, Hubert (Munich, Max Planck Inst.) ; Schwegler, Philipp (Munich, Max Planck Inst.) ; Sforza, Federico (Munich, Max Planck Inst.)
For the upgrade of the ATLAS muon spectrometer in March 2014 new muon tracking chambers (sMDT) with drift-tubes of 15 mm diameter, half of the value of the standard ATLAS Monitored Drift-Tubes (MDT) chambers, and 10~$\mu$m positioning accuracy of the sense wires have been constructed. The new chambers are designed to be fully compatible with the present ATLAS services but, with respect to the previously installed ATLAS MDT chambers, they are assembled in a more compact geometry and they deploy two additional tube layers that provide redundant rack information. [...]
arXiv:1407.0285.- 2014 - 4 p. - Published in : PoS TIPP2014 (2014) 302 Fulltext: PDF; External link: PoS server
In : International Conference on Technology and Instrumentation in Particle Physics 2014, Amsterdam, Netherlands, 2 - 6 Jun 2014, pp.302
5.
Upgrades Of The ATLAS Muon Spectrometer With sMDT Chambers / Ferretti, Claudio (University of Michigan, Department of Physics)
The Monitored Drift Tube (MDT) chambers of the ATLAS muon spectrometer demonstrated that they provide very precise and robust tracking over large areas. Goals of ATLAS muon detector upgrades are to increase the acceptance for precision muon momentum measurement and triggering and to improve the rate capability of the muon chambers in the high-background regions when the LHC luminosity increases. [...]
ATL-MUON-SLIDE-2015-306.- Geneva : CERN, 2015 - 1 p. Fulltext: PDF; External link: Original Communication (restricted to ATLAS)
6.

CERN-EX-0208006
© 2002-2024 CERN
Monitored Drift Tube (MDT) chambers for precise measurement of muon trajectories in the ATLAS muon spectrometer.
The basic detection component of the chamber is th [...]
07 Aug 2002
7.
Construction and test of the precision drift chambers for the ATLAS muon spectrometer / Bauer, F. (Munich, Max Planck Inst.) ; Blum, W. (Munich, Max Planck Inst.) ; Bratzler, U. (Munich, Max Planck Inst.) ; Dietl, H. (Munich, Max Planck Inst.) ; Kotov, S. (Munich, Max Planck Inst.) ; Kroha, H. (Munich, Max Planck Inst.) ; Lagouri, T. (Munich, Max Planck Inst.) ; Manz, A. (Munich, Max Planck Inst.) ; Ostapchuk, A. (Munich, Max Planck Inst.) ; Richter, Robert (Munich, Max Planck Inst.) et al.
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical deformation monitoring system. The chambers have to provide a track position resolution of 40 mum with a single-tube resolution of at least 80 mum und a sense wire positioning accuracy of 20 mum (rms). [...]
arXiv:1604.02259; MPI-PHE-2000-029; MPP-2016-073; MPI-PHE-2000-029; MPP-2016-073.- 2001 - 7 p. - Published in : IEEE Trans. Nucl. Sci. 48 (2001) 302 Fulltext: PDF; External link: Preprint
In : 47th IEEE Nuclear Science Symposium and Medical Imaging Conference, Lyons, France, 15 - 20 Oct 2000, pp.5/11-5/15 (v.1)
8.
ATLAS monitored drift tube assembly and test at IHEP (Protvino) / Borisov, A ; Fakhrutdinov, R M ; Kojine, A ; Larionov, A ; Pilaev, A ; Rybatchenko, V ; Salomatin, Yu I
The Monitored Drift Tube is the basic element of the muon spectrometer of ATLAS detector at LHC. More than 14000 such tubes have been assembled and tested at IHEP (Protvino) in framework of construction of end-cap drift chambers for the spectrometer. [...]
2002 - Published in : Nucl. Instrum. Methods Phys. Res., A 494 (2002) 214-217
9.
Upgrades of the ATLAS Muon Spectrometer with sMDT Chambers / Ferretti, C. (Michigan U.) ; Kroha, H. (Munich, Max Planck Inst.) /for the ATLAS Muon Collaboration
With half the drift-tube diameter of the Monitored Drift Tube (MDT) chambers of the ATLAS muon spectrometer and otherwise unchanged operating parameters, small-diameter Muon Drift Tube (sMDT) chambers provide an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit. The chamber assembly time has been reduced by a factor of seven to one working day and the sense wire positioning accuracy improved by a factor of two to better than ten microns. [...]
arXiv:1603.09544.- 2016-07-11 - 3 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 824 (2016) 538-540 Fulltext: PDF; External link: Preprint
In : Frontier Detectors for Frontier Physics: 13th Pisa Meeting on Advanced Detectors, La Biodola, Isola D'elba, Italy, 24 - 30 May 2015, pp.538-540
10.
Performance and some characteristics of MDT chambers constructed in IHEP (Protvino) for ATLAS / Bozhko, N ; Borisov, A ; Fakhroutdinov, R ; Goryatchev, S ; Goryachev, V N ; Gushchin, V ; Kozhin, A ; Larionov, A ; Paramoshkina, E ; Pilaev, A et al.
IHEP (Protvino) is responsible for construction of 60000 drift tubes and their assembling into 192 Monitored Drift Tube (MDT) chambers for two outer stations of the ATLAS Muon Spectrometer end-cap. More than 45000 tubes and 114 chambers have been assembled and tested up to now. [...]
2004
In : 50th IEEE 2003 Nuclear Science Symposium, Medical Imaging Conference, 13th International Workshop on Room Temperature Semiconductor Detectors and Symposium on Nuclear Power Systems, Portland, OR, USA, 19 - 25 Oct 2003, pp.444-8 (Vol.1)

没有寻找到什么? 尝试在以下的服务器查寻:
recid:2143418 在 Amazon
recid:2143418 在 CERN EDMS
recid:2143418 在 CERN Intranet
recid:2143418 在 CiteSeer
recid:2143418 在 Google Books
recid:2143418 在 Google Scholar
recid:2143418 在 Google Web
recid:2143418 在 IEC
recid:2143418 在 IHS
recid:2143418 在 INSPIRE
recid:2143418 在 ISO
recid:2143418 在 KISS Books/Journals
recid:2143418 在 KISS Preprints
recid:2143418 在 NEBIS
recid:2143418 在 SLAC Library Catalog