Report number physics/0008117 ; SLAC-PUB-8949 ; CERN-PS-2000-056-AE ; CLIC-Note-458 ; LINAC2000-TH206 ; JLAB-ACT-00-14
Title Coherent synchrotron radiation measurements in the CLIC test facility (CTF II)
Related titleCompact linear collider
Collider Test Facility
Author(s) Braun, Hans-Heinrich (CERN) ; Corsini, R. (CERN) ; Groening, L. (CERN) ; Zhou, F. (CERN) ; Kabel, A. (SLAC) ; Raubenheimer, T. (SLAC) ; Li, R. (Jefferson Lab) ; Limberg, T. (DESY)
Affiliation (CERN)
Publication 2000
Imprint 11 Sep 2000
Number of pages 5
In: eConf C000821 (2000) pp.TH206
In: 20th International Linear Accelerator Conference, Monterey, CA, USA, 21 - 25 Aug 2000, pp.TH206
Subject category Accelerators and Storage Rings
Accelerator/Facility, Experiment CERN PS
CLIC ; CTF
Abstract Bunches of high charge (up to 10 nC) are compressed in length in the CTF II magnetic chicane to less than 0.2 mm rms. The short bunches radiate coherently in the chicane magnetic field, and the horizontal and longitudinal phase space density distributions are affected. This paper reports the results of beam emittance and momentum measurements. Horizontal and vertical emittances and momentum spectra were measured for different bunch compression factors and bunch charges. In particular, for 10 nC bunches, the mean beam momentum decreased by about 5% while the FWHM momentum spread increased from 5% to 19%. The experimental results are compared with simulations made with the code TraFiC4.
Copyright/License © CERN (License: CC-BY-4.0)

Corresponding record in: Inspire
Email contact: Nicole.Gaillard@cern.ch


 Record created 2022-09-20, last modified 2024-10-24


Fulltext:
arXiv:physics_0008117 - Download fulltextPDF
CERN-PS-2000-056-AE - Download fulltextPDF
SLACPUB:
Download fulltextPDF
External links:
Download fulltextFulltext
Download fulltextProceedings write-up on eConf
Download fulltextJLab Document Server
Download fulltextSLAC Document Server