Description

In the resonant cavity experiment, it is vital maximize signal power at detector with the minimized reflection from source. Return loss is minimized when the impedance of source and cavity are matched to each other and this is called impedance matching. Establishing tunable antenna on source is required to get a impedance matching. Geometry and position of antenna is varied depending on the electromagnetic eld of cavity. This research is dedicated to simulation to nd such a proper design of coupling antenna, especially for axion dark matter detecting experiment. HFSS solver was used for the simulation.

Other

Abbreviations: HFSS = high frequency structural simulator

Other

This paper is dedicated for CAST-CAPP collaboration for axion detecting with dipole magnet. If you want to know more, please contact yeobk1202@kaist.ac.kr