Papers by Kamyar Soleimani
International Journal of Building Pathology and Adaptation
PurposeUniversity students spend a considerable amount of time in dorm rooms, where their environ... more PurposeUniversity students spend a considerable amount of time in dorm rooms, where their environmental condition affects residents' health, well-being, sleep quality and the associated performance. Accordingly, this study aims to run an initial assessment of the environmental quality of two dormitory buildings in Tehran, using field studies and computational simulation, and then provide feasible optimized improvement strategies. The possible correlation between architectural elements and the environmental quality and the impact of proposed solutions on the annual energy use of these spaces are also discussed.Design/methodology/approachField studies and computational simulation.FindingsResults indicate that applied strategies, including shadings, reflectors, thermal and acoustic insulations, inlet vents and ceiling fans, can boost different aspects of the thermal condition, ventilation, acoustics and visual comfort by 21.77, 55.96, 20.69 and 50.37%, respectively. Accordingly, an...
Bookmarks Related papers MentionsView impact
Journal of Daylighting, 2021
Refurbished heritage buildings usually lack in meeting the required standards defined for the new... more Refurbished heritage buildings usually lack in meeting the required standards defined for the new function especially when reused as educational buildings. Therefore, they are usually equipped with different post-occupancy retrofit strategies to achieve an acceptable level of environmental quality and energy demand. Daylight quality and the distribution of natural light is a critical issue in educational spaces, given that the low level of illuminance in classrooms can decrease students' performance and disrupt visual tasks. In this study, daylight performance of below-grade south-facing classrooms in a heritage building in Tehran, Iran is investigated by implementing 57 different daylighting retrofit strategies using climate-based daylight simulations, in relation to the metric Useful Daylight Illuminance 300-3000lux (UDI-Autonomous). The research proposes the use of reflectors on the interior ceiling and exterior side of the windows (on the ground) to achieve the highest resul...
Bookmarks Related papers MentionsView impact
Journal of Architectural Engineering
Bookmarks Related papers MentionsView impact
Journal of Daylighting, 2021
Refurbished heritage buildings usually lack in meeting the required standards defined for the new... more Refurbished heritage buildings usually lack in meeting the required standards defined for the new function especially when reused as educational buildings. Therefore, they are usually equipped with different post-occupancy retrofit strategies to achieve an acceptable level of environmental quality and energy demand. Daylight quality and the distribution of natural light is a critical issue in educational spaces, given that the low level of illuminance in classrooms can decrease students' performance and disrupt visual tasks. In this study, daylight performance of below-grade south-facing classrooms in a heritage building in Tehran, Iran is investigated by implementing 57 different daylighting retrofit strategies using climate-based daylight simulations, in relation to the metric Useful Daylight Illuminance 300-3000lux (UDI-Autonomous). The research proposes the use of reflectors on the interior ceiling and exterior side of the windows (on the ground) to achieve the highest resul...
Bookmarks Related papers MentionsView impact
Uploads
Papers by Kamyar Soleimani