Abstract
Verification of candidate biomarkers relies upon specific, quantitative assays optimized for selective detection of target proteins, and is increasingly viewed as a critical step in the discovery pipeline that bridges unbiased biomarker discovery to preclinical validation. Although individual laboratories have demonstrated that multiple reaction monitoring (MRM) coupled with isotope dilution mass spectrometry can quantify candidate protein biomarkers in plasma, reproducibility and transferability of these assays between laboratories have not been demonstrated. We describe a multilaboratory study to assess reproducibility, recovery, linear dynamic range and limits of detection and quantification of multiplexed, MRM-based assays, conducted by NCI-CPTAC. Using common materials and standardized protocols, we demonstrate that these assays can be highly reproducible within and across laboratories and instrument platforms, and are sensitive to low μg/ml protein concentrations in unfractionated plasma. We provide data and benchmarks against which individual laboratories can compare their performance and evaluate new technologies for biomarker verification in plasma.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 print issues and online access
$209.00 per year
only $17.42 per issue
Buy this article
- Purchase on SpringerLink
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
Change history
09 September 2009
In the version of this article initially published, the following acknowledgment was inadvertently left out: “The UCSF CPTAC team gratefully acknowledges the support of the Canary Foundation for providing funds to purchase a 4000 QTRAP mass spectrometer.” The acknowlegment has been added to the HTML and PDF versions of the article.
References
Rifai, N., Gillette, M.A. & Carr, S.A. Protein biomarker discovery and validation: the long and uncertain path to clinical utility. Nat. Biotechnol. 24, 971–983 (2006).
Paulovich, A.G., Whiteaker, J.R., Hoofnagle, A.N. & Wang, P. The interface between biomarker discovery and clinical validation: The tar pit of the protein biomarker pipeline. Proteomics Clin. Appl. 2, 1386–1402 (2008).
Barr, J.R. et al. Isotope-dilution mass spectrometric quantification of specific proteins: model application with apolipoprotein A-1. Clin. Chem. 42, 1676–1682 (1996).
Barnidge, D.R. et al. Absolute quantification of the G protein-coupled receptor rhodopsin by LC/MS/MS using proteolysis product peptides and synthetic peptide standards. Anal. Chem. 75, 445–451 (2003).
Gerber, S.A., Rush, J., Stemman, O., Kirschner, M.W. & Gygi, S.P. Absolute quantification of proteins and phosphoproteins from cell lysates by tandem mass spectrometry. Proc. Natl. Acad. Sci. USA 100, 6940–6945 (2003).
Barnidge, D.R., Goodmanson, M.K., Klee, G.G. & Muddiman, D.C. Absolute quantification of the model biomarker prostate-specific antigen in serum by LC-MS/MS using protein cleavage and isotope dilution MS. J. Proteome Res. 3, 644–652 (2004).
Kuhn, E. et al. Quantification of C-reactive protein in the serum of patients with rheumatoid arthritis using multiple reaction monitoring mass spectrometry and 13C-labeled peptide standards. Proteomics 4, 1175–1186 (2004).
Anderson, L. & Hunter, C.L. Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins. Mol. Cell. Proteomics 5, 573–588 (2006).
Keshishian, H., Addona, T., Burgess, M., Kuhn, E. & Carr, S.A. Quantitative, multiplexed assays for low abundance proteins in plasma by targeted mass spectrometry and stable isotope dilution. Mol. Cell. Proteomics 6, 2212–2229 (2007).
Aguiar, M., Masse, R. & Gibbs, B.F. Mass spectrometric quantitation of C-reactive protein using labeled tryptic peptides. Anal. Biochem. 354, 175–181 (2006).
Wilcken, B. Wiley, V., Hammond, J. & Carpenter, K. Screening newborns for inborn errors of metabolism by tandem mass spectrometry. N. Engl. J. Med. 348, 2304–2312 (2003).
Whiteaker, J.R. et al. Integrated pipeline for mass spectrometry-based discovery and confirmation of biomarkers demonstrated in a mouse model of breast cancer. J. Proteome Res. 6, 3875–3876 (2007).
Anderson, N.L. et al. The human plasma proteome: a non-redundant list developed by combination of four separate sources. Mol. Cell. Proteomics 3, 311–326 (2004).
Omenn, G.S. et al. Overview of the HUPO plasma proteome project: results from the pilot phase with 35 collaborating laboratories and multiple analytical groups, generating a core dataset of 3020 proteins and a publicly-available database. Proteomics 5, 3226–3245 (2005).
Kuzyk, M.A. et al. MRM-based, multiplexed, absolute quantitation of 45 proteins in human plasma. Mol. Cell. Proteomics published online, doi:10.1074/mcp.M800540-MCP200 (1 May 2009).
Anderson, N.L. & Anderson, N.G. The human plasma proteome: History, character, and diagnostic prospects. Mol. Cell. Proteomics 1, 845–867 (2002).
Whiteaker, J.R. et al. Integrated pipeline for mass spectrometry-based discovery and confirmation of biomarkers demonstrated in a mouse model of breast cancer. J. Proteome Res. 6, 3962–3975 (2007).
Berna, M. et al. Quantification of NTproBNP in rat serum using immunoprecipitation and LC/MS/MS: a biomarker of drug-induced cardiac hypertrophy. Anal. Chem. 80, 561–566 (2008).
Berna, M.J., Zhen, Y., Watson, D.E., Hale, J.E. & Ackermann, B.L. Strategic use of immunoprecipitation and LC/MS/MS for trace-level protein quantification: Myosin light chain 1, a biomarker of cardiac necrosis. Anal. Chem. 79, 4199–4205 (2007).
Labugger, R. et al. Strategy for analysis of cardiac troponins in biological samples with a combination of affinity chromatography and mass spectrometry. Clin. Chem. 49, 873–879 (2003).
Nicol, G.R. et al. Use of an immunoaffinity-mass spectrometry-based approach for the quantification of protein biomarkers from serum samples of lung cancer patients. Mol. Cell. Proteomics 7, 1974–1982 (2008).
Anderson, N.L. et al. Mass spectrometric quantitation of peptides and proteins using stable isotope standards and capture by anti-peptide antibodies (SISCAPA). J. Prot. Res. 3, 235–244 (2004).
Hoofnagle, A.N., Becker, J.O., Wener, M.H. & Heinecke, J.W. Quantification of thyroglobulin, a low-abundance serum protein, by immunoaffinity peptide enrichment and tandem mass spectrometry. Clin. Chem. 54, 1796–1804 (2008).
Kuhn, E. et al. Developing multiplexed assays for troponin I and interleukin-33 in plasma by peptide immunoaffinity enrichment and targeted mass spectrometry. Clin. Chem. published online, doi:10.1373/clinchem.2009.123935 (16 April 2009).
Biopharmaceutics Coordinating Committee, Center for Drug Evaluation and Research, Center for Veterinary Medicine, US Food and Drug Administration (FDA). Guidance for Industry: Bioanalytical Method Validation (FDA, Rockville, MD; May 2001) 〈http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/ucm070107.pdf〉.
Slev, P.R., Rawlins, M.L. & Roberts, W.L. Performance characteristics of seven automated CA 15–3 assays. Am. J. Clin. Pathol. 125, 752–757 (2006).
Sapin, R. Insulin immunoassays: fast approaching 50 years of existence and still calling for standardization. Clin. Chem. 53, 810–812 (2007).
Burkitt, W. et al. Toward Système International d'Unité-traceable protein quantification: from amino acids to proteins. Anal. Biochem. 376, 242–251 (2008).
R Development Core Team. R: A language and environment for statistical computing (R Foundation for Statistical Computing, Vienna, Austria, 2008).
Lavagnini, I. & Magno, F. A statistical overview on univariate calibration, inverse regression, and detection limits: Application to gas chromatography/mass spectrometry technique. Mass Spectrom. Rev. 26, 1–18 (2007).
Xu, X., Keefer, L.K., Ziegler, R.G. & Veenstra, T.D. A liquid chromatography-mass spectrometry method for the quantitative analysis of urinary endogenous estrogen metabolites. Nat. Protocols 2, 1350–1355 (2007).
Marazzi, A. Algorithms, Routines and S Functions for Robust Statistics (CRC Press, Boca Raton, Florida, USA, 1993).
Venables, W.N. & Ripley, B.D. Modern Applied Statistics with S edn. 4 (Springer, New York, 2002).
Currie, L.A. Limits for qualitative detection and quantitative determination. Anal. Chem. 40, 586–593 (1968).
Zorn, M.E., Gibbons, R.D. & Sonzogni, W.C. Weighted least-squares approach to calculating limits of detection and quantification by modeling variability as a function of concentration. Anal. Chem. 69, 3069–3075 (1997).
Vial, J., Mapihan, K.L. & Jardy, A. What is the best means of estimating the detection and quantification limits of a chromatographic method? Chromatographia 57 Supplement, S303–S306 (2003).
Armbruster, D.A., Tillman, M.D. & Hubbs, L.M. Limit of detection (LOD)/limit of quantitation (LOQ): Comparison of the empirical and the statistical methods exemplified with GC-MS assays of abused Drugs. Clin. Chem. 40, 1233–1238 (1994).
Linnet, K. & Kondratovich, M. Partly nonparametric approach for determining the limit of detection. Clin. Chem. 50, 732–740 (2004).
Acknowledgements
This work was supported by grants from the National Cancer Institute (NCI) (U24 CA126476, U24 126477, U24 126480, U24 CA126485, and U24 126479), part of NCI Clinical Proteomic Technologies for Cancer initiative. A component of this initiative is the Clinical Proteomic Technology Assessment for Cancer (CPTAC) Network and teams, which include the Broad Institute of MIT and Harvard (with the Fred Hutchinson Cancer Research Center, Massachusetts General Hospital, the University of North Carolina at Chapel Hill, the University of Victoria and the Plasma Proteome Institute), Memorial Sloan-Kettering Cancer Center (with the Skirball Institute at New York University), Purdue University (with Monarch Life Sciences, Indiana University, Indiana University-Purdue University Indianapolis and the Hoosier Oncology Group), University of California, San Francisco (with the Buck Institute for Age Research, Lawrence Berkeley National Laboratory, the University of British Columbia and the University of Texas M.D. Anderson Cancer Center) and Vanderbilt University School of Medicine (with the University of Texas M.D. Anderson Cancer Center, the University of Washington and the University of Arizona). A full listing of the CPTAC Team Network can be found at http://proteomics.cancer.gov/programs/CPTAC/networkmembership. The UCSF CPTAC team gratefully acknowledges the support of the Canary Foundation for providing funds to purchase a 4000 QTRAP mass spectrometer.
Author information
Authors and Affiliations
Contributions
The CPTAC Network contributed collectively to this study. The following CPTAC Network investigators contributed significant intellectual contributions to work described in this paper.
S.E.A., T.A., N.L.A., D.M.B, S.C.H., A.-J.L.H., H.K., D.R., B.S., S.J.S., L.J.Z. and S.A.C. contributed to study design and SOP development. D.M.B and N.G.D. prepared and shipped samples. S.E.A., T.A., S.A., H.L.C., J.M.H., A.J., E.B.J., H.K., D.S., T.J.T., J.R.W., A.W., S.W., L.Z., and L.J.Z. contributed to generation of data. M.P.C., J.L., D.R.M., R.K.N., S.J.S., T.C.P., P.A.R., C.H.S., D.L.T., A.M.V., and L.J.V.-M. contributed to bioinformatics and statistical analysis. S.E.A, T.A., H.K., D.R.M., S.J.S. and L.J.Z. centrally reviewed data. S.E.A., T.A., N.L.A., S.A.C., S.J.F., S.C.H., A.-J.L.H., H.K., D.R.M, B.S., S.J.S., and L.J.Z. wrote and prepared the manuscript. R.K.B., C.B., C.H.B., S.A.C., S.J.F., B.W.G., T.H., C.R.K., D.C.L., M.M., T.A.N., A.G.P., H.R., F.E.R., P.T., and M.W. contributed to experimental design. S.C.H. chaired the CPTAC Experimental Design and Statistics Verification Studies Working Group that designed interlaboratory studies and generated data.
Corresponding author
Supplementary information
Supplementary Text and Figures
Supplementary Figures 1–6, Supplementary Tables 1–6 and Supplementary Methods and Supplementary Appendix (PDF 5784 kb)
Rights and permissions
About this article
Cite this article
Addona, T., Abbatiello, S., Schilling, B. et al. Multi-site assessment of the precision and reproducibility of multiple reaction monitoring–based measurements of proteins in plasma. Nat Biotechnol 27, 633–641 (2009). https://doi.org/10.1038/nbt.1546
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/nbt.1546