Transcatheter aortic valve implantation, patient selection process and procedure: two centres' experience of the intervention without general anaesthesia

Hellenic journal of cardiology : HJC = Hellēnikē kardiologikē epitheōrēsē

transcatheter aortic valve implantation (TAVI) is an emerging technique for the treatment of aortic stenosis. With the advent of percutaneous suture devices for the access point and prosthesis delivery systems of smaller diameter, TAVI has become a truly percutaneous procedure: percutaneous aortic valve replacement (PAVR). Thus, PAVR may be conducted without general anaesthesia (GA). We report two centres' experience from PAVR without GA. CoreValve aortic bioprostheses were utilised. The patient selection process and PAVR procedure are described in detail. a total of 30 patients (pts) were treated with PAVR. In 4 pts correction of the initial malposition of the prosthesis required a special technique (2 pts: "snare"; 2 pts: "removing and reinserting"). At 1-month follow up, haemodynamic and clinical improvements were observed: left ventricular ejection fraction increased from 50.8 ± 9.3% to 54.3 ± 8.3% (p=0.02); peak aortic valve gradient decreased from 90.3 ...

Hellenic J Cardiol 2010; 51: 492-500 Original Research Transcatheter Aortic Valve Implantation, Patient Selection Process and Procedure: Two Centres’ Experience of the Intervention Without General Anaesthesia Manolis VaVuranakis1, Vasileios Voudris2, diMitrios a. Vrachatis1, sofia thoMopoulou2, konstantinos toutouzas1, GeorGe karaVolias2, ioannis tolios3, eftihia sbarouni2, GeorGe lazaros1, christina chrysohoou1, Mazen khoury2, stella brili1, Marina balanika2, carMen MoldoVan1, christodoulos stefanadis1 1 First Department of Cardiology, Hippokration Hospital, National & Kapodistrian University of Athens, 2Second Department of Cardiology, Onassis Cardiac Surgery Centre, Athens, 3Department of Anaesthesiology, Hippokration Hospital, Athens, Greece Key words: TAVI, TAVR, PAVI, PAVR, CoreValve, aortic stenosis, valvular heart disease. Manuscript received: April 28, 2010; Accepted: September 15, 2010. Address: Manolis Vavuranakis 13 Astypaleas St. 145 69 Anoixi Attiki, Greece e-mail: vavouran@otenet.gr Introduction: Transcatheter aortic valve implantation (TAVI) is an emerging technique for the treatment of aortic stenosis. With the advent of percutaneous suture devices for the access point and prosthesis delivery systems of smaller diameter, TAVI has become a truly percutaneous procedure: percutaneous aortic valve replacement (PAVR). Thus, PAVR may be conducted without general anaesthesia (GA). Methods: We report two centres’ experience from PAVR without GA. CoreValve aortic bioprostheses were utilised. The patient selection process and PAVR procedure are described in detail. Results: A total of 30 patients (pts) were treated with PAVR. In 4 pts correction of the initial malposition of the prosthesis required a special technique (2 pts: “snare”; 2 pts: “removing and reinserting”). At 1-month follow up, haemodynamic and clinical improvements were observed: left ventricular ejection fraction increased from 50.8 ± 9.3% to 54.3 ± 8.3% (p=0.02); peak aortic valve gradient decreased from 90.3 ± 26.4 mmHg to 14.8 ± 9.7 mmHg, (p<0.001); NYHA functional class decreased from 3.53 ± 0.93 to 1.45 ± 0.94 (p<0.001). Overall 1-month mortality was 3.3% (1 patient died). Conclusion: PAVR without general anaesthesia is a feasible technique, however the role of anaesthesiologists is still important. A ortic stenosis is the most common valvular abnormality in the western world.1 Although surgical aortic valve replacement (AVR) remains the gold standard for the treatment of severe symptomatic aortic stenosis,2 transcatheter aortic valve implantation (TAVI) is an emerging technique that offers an alternative to patients suffering from severe symptomatic aortic stenosis who are rejected for surgery because of increased age and left ventricular dysfunction or coexisting comorbidities.3,4 During the last 492 • HJC (Hellenic Journal of Cardiology) few years, increasing numbers of successful TAVI procedures have been reported worldwide, with encouraging short- and mid-term results.5-7 Currently, there are two CE marked prosthetic valves for TAVI: the CoreValve (Medtronic, Inc.) and the SAPIEN (Edwards Life Sciences, Inc.) both of which can be introduced transfemorally. Furthermore, the former may potentially be introduced through a subclavian artery,8-10 while the latter can be introduced transapically.5 Transcatheter Aortic Valve Implantation In the early experience with both prosthetic valves, a large diameter arterial sheath was required. Thus, surgical cut-down of the artery was compulsory in order to acquire vascular access. However, the advent of the 18 F diameter delivery sheath for the CoreValve bioprosthesis allowed interventionalists to conduct TAVI truly percutaneously. Such an intervention is feasible only when vascular access is acquired through a femoral artery, and it may be performed under either general or local anaesthesia. A more precise term for this procedure is percutaneous aortic valve replacement (PAVR), rather than TAVI. In this study we report the initial experience from two collaborating centres, of TAVI conducted truly percutaneously (PAVR), without general anaesthesia, using the CoreValve bioprosthesis. The patient selection process, pre-procedural evaluation and implantation procedure are described in detail. Methods Patient selection After evaluation by a team consisting of at least a cardiologist and two cardiac surgeons, patients diagnosed with severe aortic stenosis requiring AVR were considered as TAVI candidates if the risk for surgical AVR was “high” or if they were considered “inoperable”.11 All patients underwent implantation of a CoreValve bioprosthetic aortic valve in a procedure that did not use general anaesthesia. Each patient-candidate for TAVI underwent a process of screening and selection according to the “CoreValve Registry Criteria”. The PAVR procedure itself was performed in a separate session. All subjects provided informed consent prior to the intervention. The logistic EuroSCORE is calculated using a special algorithm.12 The parameters taken into account to compute the logistic EuroSCORE are divided into three categories: • Patient-related factors: patient’s age, sex, presence of pulmonary disease, presence of extracardiac arteriopathy, presence of neurological dysfunction, history of previous cardiac surgery, presence of active endocarditis, presence of critical preoperative state. • Cardiac-related factors, which include presence of unstable angina, assessment of left ventricular function (poor, moderate, good), history of recent myocardial infarction, presence of pulmonary hypertension. • Four operation-related factors: the patient being in an emergency state (for patients who need operation before the beginning of the next working day), operation other than isolated coronary artery bypass grafting (always applies for AVR), surgery on the thoracic aorta, and post-infarct septal rupture. Patients were defined as “high-risk” for surgical aortic valve replacement if the Logistic EuroSCORE was ≥20%. Inoperable patients Inoperable patients were defined as patients ≥65 years old who suffered from at least one of the following conditions: liver cirrhosis (Child A or B), pulmonary insufficiency (forced expiratory volume <1L), previous cardiac surgery, pulmonary hypertension (pulmonary arterial pressure >60 mmHg), recurrent pulmonary embolisms, right ventricular failure, hostile thorax (radiation, burns, etc.), severe connective tissue disease, cachexia. Surgical risk assessment Screening process: “CoreValve Registry Criteria” High risk patients Surgical risk is largely evaluated by two risk-assessment systems: the logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE)12 and the Society of Thoracic Surgeons (STS) score.13 Lately, the accuracy of the EuroSCORE has been under dispute, with reports suggesting that it overestimates the surgical risk.14 Nevertheless, logistic EuroSCORE is widely used to assess surgical risk in the patient selection according to the “CoreValve Registry Criteria”. All patients underwent comprehensive screening prior to the procedure. A synopsis of the screening process is presented in Figure 1. Pre-interventional screening with echocardiography consisted of assessment of heart anatomy and functionality. The presence of atrial or ventricular thrombus, mitral regurgitation >Grade 2, left ventricular ejection fraction <20%, severe left ventricular hypertrophy (≥1.7 cm) and presence of sub-aortic stenosis were all exclusion criteria. (Hellenic Journal of Cardiology) HJC • 493 M. Vavuranakis et al Aortic Stenosis requiring AVR Surgical Risk? Logistic EuroSCORE <15-20% Surgical AVR Logistic EuroSCORE ≥15-20% Patient Inoperable Assess Aortic Root Anatomy with TTE Rejected Accepted Assess Anatomy, Vascular Access and CAD with Angiogram Rejected Palliative Balloon Valvuloplasty PCI if required if further vascular evaluation is required: CT-Angiogram Accepted Femoral PAVR Subclavian TAVI Apical Figure 1. Patient screening process algorithm for transcatheter aortic valve implantation (TAVI) or percutaneous aortic valve replacement (PAVR). CAD – coronary artery disease; PCI – percutaneous coronary intervention; TTE – transthoracic echocardiography. Angiographic evaluation followed the ultrasound analysis. Initially, a coronary angiogram was performed. In patients who suffered from proximal coronary stenosis ≥70% revascularisation was conducted prior to valve implantation. Aortic annulus (Figure 2) width had to be 20-23 mm or 24-27 mm for the 26 mm and 29 mm devices, respectively. Patients with an annulus width <20 mm or >27 mm were not eligible for TAVI with the CoreValve Revalving System. The angle between the axis of the ascending aorta within its first 7 cm and a perpendicular line across the aortic valve (i.e. annulus-to-aorta angle) ideally should be <30o. However, an annulus-to-aorta angle from 30o up to 45o was not considered as a reason to reject the patient, whereas an angle >45o was unacceptable. In addition, the height of the sinuses of Valsalva was measured on angiography. A height ≥15 mm was preferred, while 10-14 mm was considered as borderline. A patient with a borderline height could be successfully treated only if the coronary sinus width was >27 mm. This provides adequate space for coronary ostium perfusion outside the neck of the valve. An as494 • HJC (Hellenic Journal of Cardiology) Figure 2. Aortic annulus measurement on the transthoracic echocardiogram. cending aortic arch diameter >43 mm, a low “takeoff” position of the coronary ostia (the distance between the coronary ostia and the aortic annulus), high angulation or sharp bend of the aortic arch, were also considered as exclusion criteria. In order to evaluate the approach for vascular access, all patients underwent a subclavian and an abdominal aorto-iliac angiogram. Transcatheter Aortic Valve Implantation A C B Figure 3. Pre-procedural angiograms with a 5 F metric pigtail catheter: A – left subclavian artery; B – aorto-iliac angiogram; C – femoral artery angiogram. All angiographic measurements were performed using a 5F metric pigtail (Figure 3). In cases where more imaging was required to clarify some of the previously mentioned parameters, patients were further screened with transoesophageal echocardiography or a CT angiogram. Femoral artery access: exclusion criteria PAVR through a femoral artery using a CoreValve prosthesis (Figure 4) is contraindicated, because of the increased risk of vascular complications, in the following situations: excessive angulation or calcifi- A B C D Figure 4. CoreValve bioprosthesis: A – side view; B – aortic outflow view; C – partially “compressed” prior to mounting on the delivery device; D – completely mounted on the delivery system. (Hellenic Journal of Cardiology) HJC • 495 M. Vavuranakis et al cation in the aorta, iliac or femoral arteries; diameter less than 6 mm in the iliac/femoral arteries; significant obstructive atherosclerotic disease; ulcerated plaques or dissections. Device description and procedure The CoreValve prosthesis consists of a tri-leaflet bioprosthetic porcine pericardial tissue valve, which is mounted and sutured in a self-expanding nitinol stent (Figure 4). The prosthetic frame (stent) is manufactured by laser cutting and has an overall length of 50 mm. Pre-procedurally all patients were pre-treated with acetylsalicylic acid (100 mg/day). They were also given a 300 mg loading dose of clopidogrel. During intervention, patients received weight-adjusted intravenous heparin with a target of an activated clotting time of 250-300 s for the duration of the procedure. Post-procedurally, a 75 mg/day maintenance dose of clopidogrel for at least 6 months and lifelong 100 mg/ day acetylsalicylic acid were prescribed. The procedure was conducted in the catheterisation laboratory with operating-room–like sterile precautions.5 Vascular access was obtained with standard percutaneous access techniques through the femoral artery and percutaneous closure was performed using a preloaded Prostar XL suture device (Abbott Vascular, Abbott Park, IL) (Figure 5).15 All patients received only local anaesthesia (1% lidocaine was applied subcutaneously at the vascular access sites) and mild sedation (propofol, midazolame; doses adjusted by the anaesthesiologist). In addition, an oxygen face-mask (FiO2 50%) was applied during the intervention, while oxygen blood saturation was monitored with pulse oximetry. Prior to prosthesis implantation, aortic angiography was conducted. Subsequently, balloon valvuloplasty was performed with a 22-25 mm diameter balloon under rapid ventricular pacing. Then, the deployment procedure was initiated. The CoreValve prosthesis was advanced retrogradely over a stiff guidewire and deployed within the aortic annulus. Deployment of the prosthetic valve consisted of three stages.16 During the first stage, the operator had full control of the valve expansion, without being forced to rapidly deploy the valve, since the valve was deployed under the patient’s native rhythm. During the second stage, the partially deployed prosthesis obstructed the aortic valve flow, blood pressure was compromised and the operator performed deployment in an uninterrupted mode until blood pressure returned to baseline. The third step was then completed, without any need for hurry, since sufficient blood flow was maintained through the deployed valve. Haemodynamic outcomes, proper prosthesis placement and potential aortic valve regurgitation were assessed serially by aortograms. After PAVR, patients were transferred to the intensive care unit. Post-procedurally, patients were evaluated clinically and with transthoracic two-dimensional echocardiography immediately after implantation, at hospital discharge (~5 days), and at 1 month. Statistical analysis Continuous variables are presented as mean ± standard deviation unless stated otherwise. The non-parametric Kolmogorov-Smirnov test and histograms were used to assess, statistically and graphically, the normality of distribution of continuous variables. Differences between groups were evaluated by twotailed, independent samples Student t-test (or Wilcoxon non-parametric test when appropriate) for continuous variables. A 2-sided p-value <0.05 was considered to represent statistical significance. Statistical analysis was performed using SPSS 15 for Windows (SPSS Inc, Chicago, Illinois, USA). Results Patient population During 2008 and 2009, 30 patients had a successful PAVR. A total of 16 patients were enrolled for the 26 Figure 5. Prostar XL suture device after removal from the puncture site. 496 • HJC (Hellenic Journal of Cardiology) Transcatheter Aortic Valve Implantation mm and 14 patients for the 29 mm prosthesis. Baseline patient characteristics are shown in Table 1. All patients had severe symptomatic aortic stenosis. The mean calculated logistic EuroSCORE of the population was 27.1 ± 14.4%, while 14 and 16 patients were assigned to New York Heart Association functional classes III and IV, respectively. Mean aortic valve pressure gradient was 57.4 ± 17.3 mmHg and peak aortic valve pressure gradient was 90.3 ± 26.4 mmHg. Pre-procedural mean aortic valve area was 0.63 ± 0.15 cm2 and mean systolic left ventricular ejection fraction was 50.8 ± 9.3%. tamponade, stroke) or major bleeding (requiring surgery and/or blood transfusion) were not observed in any patient within the first 48 h after PAVR. One-month follow up and clinical evaluation Overall 30-day mortality was 3.3%; 1 patient died on day 26 post-PAVR due to severe pulmonary fibrosis and multiple organ failure. Overall, the patients’ New York Heart Association functional classification improved compared to their initial state (to 1.45 ± 0.1 from 3.53 ± 0.1, p<0.001) (Figure 6A). Moreover, left ventricular ejection fraction showed a significant increase, while peak and mean aortic valve pressure gradient, as assessed from the transthoracic echocardiogram, decreased significantly (Table 3). Additionally, the peak aortic valve pressure gradient of each and every individual remained decreased at one month (Figure 6B). Acute post-procedural evaluation Immediate post-procedural evaluation showed stable prosthesis placement and adequate function in 26 patients. However, in 4 patients the initial positioning of the prosthesis was not optimal and the prosthesis was successfully repositioned by performing the “removing and reinserting technique” (2 patients) or the “snare technique” (2 patients).16 Direct haemodynamic improvement was observed in all patients. Intubation and general anaesthesia were not required in any patient; thus, all interventions were successfully completed with the patient under local anaesthesia. Neither coronary flow impairment nor aortic dissection was observed in any patient. Major cardiovascular and cerebral events (death from any cause, myocardial infarction, cardiac Discussion This study’s main finding is that TAVI without the use of general anaesthesia is a feasible technique. We reproduced similar results to those reported for the implantation of CoreValve prosthesis under general anaesthesia. The need for aortic valve replacement is expected to escalate as mean life expectancy increases.11 Over time, the patient selection criteria for TAVI/PAVR will be expanded and we will see further device enhancement and improvement in the opera- Table 1. Baseline population characteristics. Variable Patients (n) Female sex Age (years) Hypertension Hyperlipidaemia Diabetes mellitus Smoking NYHA functional class: Class III Class IV Logistic EuroSCORE (%) Aortic valve area (cm2) LVEF (%) Peak AV gradient (mmHg) Mean AV gradient (mmHg) Centre 1 20 12 (60) 77.1 ± 7.0 (61-85) 12 (60) 6 (30) 7 (35) 4 (20) 10 10 24.1 ± 13.9 0.59 ± 0.16 51.25 ± 8.54 96.8 ± 25.0 59.3 ± 15.7 (50) (50) (6.0-57) (0.30-0.90) (30-65) (67-156) (39-96) Centre 2 10 4 (40) 77.2 ± 7.5 (67-90) 10 (100) 7 (70) 4 (40) 7 (70) 4 6 33.0 ± 14.1 0.70 ± 0.13 49.8 ± 11.1 77.4 ± 25.3 53.6 ± 20.5 (40) (60) (11.4-59.3) (0.57-0.90) (30-60) (55-141) (31-100) Values are expressed as number (%) or mean ± SD (range). NYHA – New York Heart Association; LVEF – left ventricular ejection fraction; AV – aortic valve. Centre 1: 1st Department of Cardiology, Hippokration Hospital, National & Kapodistrian University of Athens, Greece. Centre 2: 2nd Department of Cardiology, Onassis Cardiac Surgery Centre, Athens, Greece. (Hellenic Journal of Cardiology) HJC • 497 M. Vavuranakis et al A B 4 160 NYHA Functional Class 3 Aortic Valve Peak Gradient, mmHg 140 p<0.001 2 1 0 120 100 80 60 40 20 0 Pre-PAVR 1m - Post - PAVR Pre-PAVR 1m-Post-PAVR Figure 6. A. New York Heart Association functional class before and 1 month after percutaneous aortic valve replacement (PAVR), displayed as mean ± standard error (3.53 ± 0.093 and 1.45 ± 0.094, respectively; p<0.001). B. Aortic valve peak gradient before and 1 month after PAVR for each individual patient. tors’ experience. Therefore, simplification of the procedure is important for its widespread use. The choice between general and local anaesthesia is a point of dispute. Currently, there are no guidelines regarding which patients should receive one or the other. Thus, the final decision depends upon the consensus of the heart-valve team. It is important to note that local anaesthesia may be used only when a femoral artery is the site of access. In fact, femoral access is preferred for the majority of the patients. Yet, when any absolute or relative contraindications17 apply, subclavian or transapical access (with CoreValve or SAPIEN prosthesis, respectively) should be reassessed. In a procedure performed under general anaesthesia, the patient is completely immobile, which facilitates the interventionalist’s manipulations. This is not always the case under local anaesthesia; the patient has to remain in the same position the throughout the whole procedure, which may be stressful. On Table 2. One-month clinical follow up. Variable Patients (n) NYHA functional class (n): Class I Class II LVEF (%) Peak AV gradient (mmHg) Mean AV gradient (mmHg) Centre 1 Centre 2 20 9 11 9 54.6 ± 7.2 (35-65) 15.7 ± 10.9 (5.5-45.0) 8.4 ± 6.5 (3.0-28.0) 5 4 53.6 ± 10.7 (35-60) 12.7 ± 6.2 (7.0-23.0) 6.9 ± 2.9 (4.0-13.0) Abbreviations and notes as in Table 1. Table 3. Total population before (Pre-PAVR) and 1 month after (1m-Post-PAVR) percutaneous aortic valve replacement. Variable LVEF (%) Peak AV gradient (mmHg) Mean AV gradient (mmHg) Other abbreviations as in Table 1. 498 • HJC (Hellenic Journal of Cardiology) Pre-PAVR 50.8 ± 9.3 (30-65) 90.3 ± 26.4 (55-156) 57.3 ± 17.3 (31.0-100.0) 1m-post-PAVR 54.3 ± 8.3 (35-65) 14.8 ± 9.7 (5.5-45) 7.9 ± 5.6 (3.0-28.0) p 0.002 <0.001 <0.001 Transcatheter Aortic Valve Implantation the other hand, the intervention itself does not induce any major surgical stimulation. However, mild sedation can make it more convenient for the patient and the operators. Another advantage of general anaesthesia is the option of transoesophageal echocardiography as a supplementary imaging modality. Nevertheless, general anaesthesia makes the intervention more complex. Its potential complications, predominantly respiratory, may not be well tolerated in the high-risk patients who undergo PAVR. Moreover, the metabolic capacity of such patients is a significant point to be taken into account. Despite the fact that general anaesthesia seems not to be a prerequisite for a PAVR procedure, the role of the anaesthesiologist is still important. The catheterisation laboratory should be properly equipped for an emergent conversion to general anaesthesia, while close monitoring of the patient during the operation is crucial. Thus, the anaesthesiologist is an integral part of the team performing a PAVR. The stepwise process for prosthesis delivery and implantation is not altered if the patient is under general anaesthesia or under mild sedation. However, it must be strongly stressed that, in the case of major complications, general anaesthesia provides a more controlled and safe environment. Still, operators should pay close attention to the manipulation of the sheaths (18 F diameter) used for valve introduction as they are currently the “Achilles’ heel” for vascular complications. Delivery sheaths of a smaller external diameter, which are to be developed by the biotechnology industry, should render PAVR a much safer intervention in the near future. Another critical point to confront is the accurate positioning of the prosthesis; this is not affected by the absence or presence of general anaesthesia. Nonetheless, initial malposition may be corrected with repositioning manipulations (“removing and reinserting technique”, “snare technique”).16,18,19 These techniques should be considered as “bail-out” techniques, while the degree of the operator’s familiarity (or unfamiliarity) with them should be kept in mind. Implantation of a second valve within the first (“valve-in-valve technique” or “Russian doll concept”) has been proposed as an alternative.20,21 We underline that these techniques can be successfully conducted without the need for crossover to general anaesthesia. If none of them is possible, urgent conversion to surgical aortic valve replacement should be considered. Finally, we must admit that a selection bias could occur during the decision to conduct a PAVR without general anaesthesia. Our study supports the view that this is a good alternative, but it does not suggest any selection criteria for deciding between PAVR with or without general anaesthesia. Conclusion Based on our initial experience, PAVR without general anaesthesia using a CoreValve prosthesis is a safe procedure, provided that the patients selected for the intervention are comprehensively screened in advance. However, it is still a technically demanding procedure, which requires a multidisciplinary team of interventionalists and anaesthesiologists. Indisputably, the choice of device to be implanted (CoreValve or SAPIEN) and the route of implantation (transfemoral PAVR, trans-subclavian or transapical TAVI) are critical and should be based on a patient-centred view, rather than the operator’s skills. Thorough investigation and understanding of the comorbidities prior to decision making are the key to success. Further studies are needed to evaluate the longterm durability of the prosthetic valve, so that the appropriate patient population for this procedure may be expanded. References 1. Iung B, Baron G, Butchart EG, et al. A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease. Eur Heart J. 2003; 24: 1231-1243. 2. Vahanian A, Baumgartner H, Bax J, et al. Guidelines on the management of valvular heart disease: The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology. Eur Heart J. 2007; 28: 230-268. 3. Iung B, Cachier A, Baron G, et al. Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery? Eur Heart J. 2005; 26: 2714-2720. 4. Vahanian A, Alfieri O, Al-Attar N, et al. Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European association of cardio-thoracic surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). EuroIntervention. 2008; 4: 193-199. 5. Spargias K, Manginas A, Pavlides G, et al. Transcatheter aortic valve implantation: first Greek experience. Hellenic J Cardiol. 2008; 49: 397-407. 6. Tamburino C, Capodanno D, Mule M, et al. Procedural success and 30-day clinical outcomes after percutaneous aortic valve replacement using current third-generation self-expanding CoreValve prosthesis. J Invasive Cardiol. 2009; 21: 93-98. (Hellenic Journal of Cardiology) HJC • 499 M. Vavuranakis et al 7. Spargias K. Percutaneous aortic valve implantation: present and future. Controlled clinical application before the results of randomised trials. Hellenic J Cardiol. 2009; 50: 237-244. 8. Vavuranakis M, Vrachatis DA, Toutouzas K, Economopoulos G, Kalogeras KI, Stefanadis C. Successful percutaneous aortic valve implantation via a stenotic left subclavian artery access. Heart Vessels. 2010; 25: 359-362. 9. Bojara W, Mumme A, Gerckens U, et al. Implantation of the CoreValve self-expanding valve prosthesis via a subclavian artery approach: a case report. Clin Res Cardiol. 2009; 98: 201-204. 10. Vavuranakis M, Vrachatis DA, Filis K, Stefanadis C. Trans-catheter aortic-valve implantation by the subclavian approach complicated with vessel dissection and transient left-arm paralysis. Eur J Cardiothorac Surg. 2010. doi:10.1016/j.ejcts.2010.06.003. 11. Chiam PTL, Ruiz CE. Percutaneous transcatheter aortic valve implantation: Evolution of the technology. Am Heart J. 2009; 157: 229-242. 12. Roques F, Michel P, Goldstone AR, Nashef SAM. The logistic EuroSCORE. Eur Heart J. 2003; 24: 881-882. 13. Edwards FH, Grover FL, Shroyer AL, Schwartz M, Bero J. The Society of Thoracic Surgeons National Cardiac Surgery Database: current risk assessment. Ann Thorac Surg. 1997; 63: 903-908. 14. Kalavrouziotis D, Li D, Buth KJ, Légaré J-F. The European System for Cardiac Operative Risk Evaluation (EuroSCORE) is not appropriate for withholding surgery in high- 500 • HJC (Hellenic Journal of Cardiology) 15. 16. 17. 18. 19. 20. 21. risk patients with aortic stenosis: a retrospective cohort study. J Cardiothorac Surg. 2009; 4: 32. de Jaegere P, van Dijk LC, Laborde J-C, et al. True percutaneous implantation of the CoreValve aortic valve prosthesis by the combined use of ultrasound guided vascular access, Prostar(R) XL and the TandemHeart(R). EuroIntervention. 2007; 2: 500-505. Vavouranakis M, Vrachatis DA, Toutouzas KP, Chrysohoou C, Stefanadis C. “Bail out” procedures for malpositioning of aortic valve prosthesis (CoreValve). Int J Cardiol. 2010; 145: 154-155. Zajarias A, Cribier AG. Outcomes and safety of percutaneous aortic valve replacement. J Am Coll Cardiol. 2009; 53: 1829-1836. Vavuranakis M, Vrachatis D, Stefanadis C. CoreValve aortic bioprosthesis: repositioning techniques. JACC Cardiovasc Interv. 2010; 3: 565; author reply 565-566. Latib A, Michev I, Laborde JC, Montorfano M, Colombo A. Post-implantation repositioning of the CoreValve percutaneous aortic valve. JACC Cardiovasc Interv. 2010; 3:119-121. Ussia GP, Mulè M, Tamburino C. The valve-in-valve technique: transcatheter treatment of aortic bioprothesis malposition. Catheter Cardiovasc Interv. 2009; 73: 713-716. Piazza N, Schultz C, de Jaegere PPT, Serruys PW. Implantation of two self-expanding aortic bioprosthetic valves during the same procedure-Insights into valve-in-valve implantation (“Russian doll concept”). Catheter Cardiovasc Interv. 2009; 73: 530-539.