Novel gradient coils designed using a boundary element method
… Fast imaging modalities, such as echo-planar imaging (EPI) (3), demand increased
performance from the gradient coils. The current in the gradient coils must be switched rapidly and …
performance from the gradient coils. The current in the gradient coils must be switched rapidly and …
Minimum energy MRI gradient coils of general geometry
S Pissanetzky - Measurement Science and Technology, 1992 - iopscience.iop.org
The author presents a new method for the design of gradient coil systems for magnetic
resonance imaging (MRI) with minimum energy. The new method eliminates previous restrictions …
resonance imaging (MRI) with minimum energy. The new method eliminates previous restrictions …
Equivalent magnetization current method applied to the design of gradient coils for magnetic resonance imaging
… This concept is applied to the design of gradient coils of arbitrary … This method can be used
for gradient coils wound on … We apply this concept to the design of gradient coils for MRI. …
for gradient coils wound on … We apply this concept to the design of gradient coils for MRI. …
Optimization of torque‐balanced asymmetric head gradient coils
DC Alsop, TJ Connick - Magnetic resonance in medicine, 1996 - Wiley Online Library
… is the use of local gradient coils. Because smaller local gradient coils generally store and …
The design of smaller gradient coils is frequently hampered by the asymmetric geometry of …
The design of smaller gradient coils is frequently hampered by the asymmetric geometry of …
Theory of gradient coil design methods for magnetic resonance imaging
SS Hidalgo‐Tobon - Concepts in Magnetic Resonance Part A, 2010 - Wiley Online Library
… In modern MRI, gradient coils able to generate high gradient … of gradient coils that generate
magnetic fields, which vary linearly with position over the imaging volume. Gradient coils for …
magnetic fields, which vary linearly with position over the imaging volume. Gradient coils for …
Insertable biplanar gradient coils for magnetic resonance imaging
MA Martens, LS Petropoulos, RW Brown… - Review of scientific …, 1991 - pubs.aip.org
Insertable planar gradient coils offer the potential for significant performance increases in
magnetic resonance imaging through higher gradient strength and shorter rise times. Using …
magnetic resonance imaging through higher gradient strength and shorter rise times. Using …
Performance evaluation of matrix gradient coils
Objective In this paper, we present a new performance measure of a matrix coil (also known
as multi-coil) from the perspective of efficient, local, non-linear encoding without explicitly …
as multi-coil) from the perspective of efficient, local, non-linear encoding without explicitly …
Local head gradient coils: window (s) of opportunity
EC Wong - Neuroimage, 2012 - Elsevier
… ; daughter boards on the gradient amplifiers swapped to custom boards with RC values
adjusted to provide stable feedback under a low inductance load; whole body gradient coils …
adjusted to provide stable feedback under a low inductance load; whole body gradient coils …
Overview of methods for noise and heat reduction in MRI gradient coils
E Motovilova, SA Winkler - Frontiers in physics, 2022 - frontiersin.org
… Accurate numerical modeling of gradient coils is essential for producing realistic predictions
of SPLs. We numerically study and analyze gradient coils using a comprehensive numerical …
of SPLs. We numerically study and analyze gradient coils using a comprehensive numerical …
Design and evaluation of shielded gradient coils
JW Carlson, KA Derby, KC Hawryszko… - Magnetic resonance …, 1992 - Wiley Online Library
… The methods presented in this paper can be used to generate gradient coils of arbitrarily
high homogeneity at maximum efficiency. It is difficult to compare the efficiency achieved in …
high homogeneity at maximum efficiency. It is difficult to compare the efficiency achieved in …