Europe PMC
Nothing Special   »   [go: up one dir, main page]

Europe PMC requires Javascript to function effectively.

Either your web browser doesn't support Javascript or it is currently turned off. In the latter case, please turn on Javascript support in your web browser and reload this page.

This website requires cookies, and the limited processing of your personal data in order to function. By using the site you are agreeing to this as outlined in our privacy notice and cookie policy.

Abstract 


This prospective observational study aimed at evaluating efficacy and biocompatibility performances of the new heparin-coated Evodial dialyzers with/without systemic heparin reduction. After a 4-week wash-out period with reference polysulfone F70S dialyzers, 6 hemodialysis patients were sequentially dialyzed with Evodial, F70S, and Evodial dialyzers using 30% heparin reduction, each period of treatment was 4 weeks. Removal rates (RR) (urea, creatinine, and β2-microglobulin), dialysis dose, and instantaneous clearances (urea and creatinine) were measured as well as inflammatory (C-reactive protein, fibrinogen, interleukin 6, tumor necrosis factor α, and monocyte chemoattractant protein-1) and oxidative stress (OS) (superoxide anion, homocysteine, and isoprostanes) parameters at the end of each study period. Patients treated with Evodial or F70S dialyzers for 4 weeks presented comparable dialysis efficacy parameters including urea and creatinine RR, dialysis dose and instantaneous clearances. By contrast, a significantly lower but reasonably good β2-microglobulin RR was achieved with Evodial dialyzers. Regarding biocompatibility, no significant difference was observed with inflammation and OS except for postdialysis monocyte chemoattractant protein-1 which significantly decreased with Evodial dialyzers. Thirty percent heparinization reduction with Evodial dialyzers did not induce any change in inflammation but led to an improvement in OS as demonstrated by a decrease in postdialysis superoxide production and predialysis homocysteine and isoprostane. This bioactive dialyzer together with heparin dose reduction represents a good trade-off between efficacy and biocompatibility performance (improvement in OS with a weak decrease in efficacy) and its use is encouraging for hemodialysis patients not only in reducing OS but also in improving patient comorbid conditions due to lesser heparin side effects.

References 


Articles referenced by this article (22)


Show 10 more references (10 of 22)

Citations & impact 


Impact metrics

Jump to Citations

Citations of article over time

Smart citations by scite.ai
Smart citations by scite.ai include citation statements extracted from the full text of the citing article. The number of the statements may be higher than the number of citations provided by EuropePMC if one paper cites another multiple times or lower if scite has not yet processed some of the citing articles.
Explore citation contexts and check if this article has been supported or disputed.
https://scite.ai/reports/10.1111/j.1542-4758.2010.00494.x

Supporting
Mentioning
Contrasting
3
20
0

Article citations


Go to all (15) article citations

Similar Articles 


To arrive at the top five similar articles we use a word-weighted algorithm to compare words from the Title and Abstract of each citation.