Nothing Special   »   [go: up one dir, main page]

PoS - Proceedings of Science
Volume 449 - The European Physical Society Conference on High Energy Physics (EPS-HEP2023) - T12 Detector R&D and Data Handling
Performance and characterisation of the Phase-2 CMS Inner Tracker Endcap pixel detector
W. Jin*  on behalf of the CMS Tracker Group
Full text: pdf
Pre-published on: December 14, 2023
Published on: March 21, 2024
Abstract
The High Luminosity Large Hadron Collider (HL-LHC) at CERN is expected to collide protons at 14 TeV center-of-mass energy and to reach the unprecedented peak instantaneous luminosity of 7.5 $\times 10^{34}$ cm$^{-2} $s$^{-1}$ with 200 collisions in average per bunch crossing. This will allow the ATLAS and CMS experiments to collect integrated luminosity up to 4000 fb$^{-1}$ each during the project lifetime. To cope with this extreme scenario, the CMS detector will be substantially upgraded before the HL-LHC phase, a plan known as the CMS Phase-2 upgrade. The entire CMS Inner Tracker (IT) detector will be replaced, and the new detector will feature increased radiation hardness, higher granularity, capability to handle higher data rates and longer trigger latency. The upgraded IT will be composed of a barrel part, TBPX, and small and large forward disks, TFPX and TEPX. The novel scheme of serial powering will be deployed to power the pixel modules, and new technologies will be used for a high bandwidth readout system. The TEPX detector has four large disks on each end, extending the tracking coverage up to $|\eta| < 4.0$. Each disk employs a thin PCB which carries the data and power from/to the modules. In this contribution, the design of the new TEPX detector will be presented, focusing on the disk characterization. The performance of the CMS Read-OUT Chip (CROC) quad modules, either digital or with planar sensors, will be discussed, with a focus on the comparison between the behaviour standalone or in a TEPX disk serial power chain, in terms of noise and threshold uniformity. The final design of the TEPX disk PCB is evaluated by testing the modules connected to the disk, in terms of data transmission quality compared to the standalone case.
DOI: https://doi.org/10.22323/1.449.0578
How to cite

Metadata are provided both in "article" format (very similar to INSPIRE) as this helps creating very compact bibliographies which can be beneficial to authors and readers, and in "proceeding" format which is more detailed and complete.

Open Access
Creative Commons LicenseCopyright owned by the author(s) under the term of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.